-
Comparison of measurement systems for assessing number- and mass-based particle filtration efficiency
Authors:
Timothy A. Sipkens,
Joel C. Corbin,
Triantafillos Koukoulas,
Andrew Oldershaw,
Thierry Lavoie,
Jalal Norooz Oliaee,
Fengshan Liu,
Ian D. Leroux,
Gregory J. Smallwood,
Prem Lobo,
Richard G. Green
Abstract:
The particle filtration efficiency (PFE) of a respirator or face mask is one of its key properties. While the physics of particle filtration results in the PFE being size-dependent, measurement standards are specified using a single, integrated PFE, for simplicity. This integrated PFE is commonly defined with respect to either the number (NBFE) or mass (MBFE) distribution of particles as a functio…
▽ More
The particle filtration efficiency (PFE) of a respirator or face mask is one of its key properties. While the physics of particle filtration results in the PFE being size-dependent, measurement standards are specified using a single, integrated PFE, for simplicity. This integrated PFE is commonly defined with respect to either the number (NBFE) or mass (MBFE) distribution of particles as a function of size. This relationship is non-trivial; it is influenced by both the shape of the particle distribution and the fact that multiple practical definitions of particle size are used. This manuscript discusses the relationship between NBFE and MBFE in detail, providing a guide to practitioners. Our discussion begins with a theoretical discussion of the underlying principles. We then present experimental results for a database of size-resolved PFE (SPFE) measurements for over 900 candidate respirators and filter media, including filter media with systematically varied properties and commercial samples that span the 20%-99.8% MBFE. The observed relationships between NBFE and MBFE are discussed in terms of the most-penetrating particle size (MPPS) and charge state of the media. For the NaCl particles used here, we observed that MBFEs were greater than NBFEs for charged materials and vice versa for uncharged materials. This relationship is observed because a shift from NBFE to MBFE weights the distribution towards larger sizes, while charged materials shift the MPPS to smaller sizes. Results are validated by comparing the output of a pair of TSI 8130As, a common instrument used in gauging standards compliance, to that of MBFEs computed from a system capable of measuring SPFE.
△ Less
Submitted 28 January, 2022;
originally announced January 2022.
-
Towards a Transportable Aluminium Ion Quantum Logic Optical Clock
Authors:
S. Hannig,
L. Pelzer,
N. Scharnhorst,
J. Kramer,
M. Stepanova,
Z. T. Xu,
N. Spethmann,
I. D. Leroux,
T. E. Mehlstäubler,
P. O. Schmidt
Abstract:
With the advent of optical clocks featuring fractional frequency uncertainties on the order of $10^{-17}$ and below, new applications such as chronometric levelling with few-cm height resolution emerge. We are develo** a transportable optical clock based on a single trapped aluminium ion, which is interrogated via quantum logic spectroscopy. We employ singly-charged calcium as the logic ion for…
▽ More
With the advent of optical clocks featuring fractional frequency uncertainties on the order of $10^{-17}$ and below, new applications such as chronometric levelling with few-cm height resolution emerge. We are develo** a transportable optical clock based on a single trapped aluminium ion, which is interrogated via quantum logic spectroscopy. We employ singly-charged calcium as the logic ion for sympathetic cooling, state preparation and readout. Here we present a simple and compact physics and laser package for manipulation of $^{40}\mathrm{Ca}^+$. Important features are a segmented multi-layer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber $^{40}\mathrm{Ca}^+$ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on $^{27}\mathrm{Al}^+$, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for $^{27}\mathrm{Al}^+$ has been determined to be \sods and the black-body radiation shift is $δν_\mathrm{BBR}/ν=(-4.0\pm0.4)\times10^{-18}$. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of $ω_\mathrm{rad,Ca+} \approx2π\times2.5\,\mathrm{MHz}$ ($ω_\mathrm{ax,Ca+} \approx2π\times1.5\,\mathrm{MHz}$) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.
△ Less
Submitted 14 May, 2019; v1 submitted 8 January, 2019;
originally announced January 2019.
-
Robust optical clock transitions in trapped ions
Authors:
Nati Aharon,
Nicolas Spethmann,
Ian D. Leroux,
Piet O. Schmidt,
Alex Retzker
Abstract:
We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of continuous driving fields to form a pair of dressed states essentially free of all relevant shifts. Specifically, the clock transition is robust to magnetic shifts,…
▽ More
We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of continuous driving fields to form a pair of dressed states essentially free of all relevant shifts. Specifically, the clock transition is robust to magnetic shifts, quadrupole and other tensor shifts, and amplitude fluctuations of the driving fields. The scheme is applicable to either a single ion or an ensemble of ions, and is relevant for several types of ions, such as $^{40}\mathrm{Ca}^{+}$, $^{88}\mathrm{Sr}^{+}$, $^{138}\mathrm{Ba}^{+}$ and $^{176}\mathrm{Lu}^{+}$. Taking a spherically symmetric Coulomb crystal formed by 400 $^{40}\mathrm{Ca}^{+}$ ions as an example, we show through numerical simulations that the inhomogeneous linewidth of tens of Hertz in such a crystal together with linear Zeeman shifts of order 10~MHz are reduced to form a linewidth of around 1~Hz. We estimate a two-order-of-magnitude reduction in averaging time compared to state-of-the art single ion frequency references, assuming a probe laser fractional instability of $10^{-15}$. Furthermore, a statistical uncertainty reaching $2.9\times 10^{-16}$ in 1~s is estimated for a cascaded clock scheme in which the dynamically decoupled Coulomb crystal clock stabilizes the interrogation laser for an $^{27}\mathrm{Al}^{+}$ clock.
△ Less
Submitted 6 December, 2018; v1 submitted 16 November, 2018;
originally announced November 2018.
-
Controlling the potential landscape and normal modes of ion Coulomb crystals by a standing wave optical potential
Authors:
Thomas Lauprêtre,
Rasmus B. Linnet,
Ian D. Leroux,
Haggai Landa,
Aurélien Dantan,
Michael Drewsen
Abstract:
Light-induced control of ions within small Coulomb crystals is investigated. By intense intracavity optical standing wave fields, subwavelength localization of individual ions is achieved for one-, two-, and three-dimensional crystals. Based on these findings, we illustrate numerically how the application of such optical potentials can be used to tailor the normal mode spectra and patterns of mult…
▽ More
Light-induced control of ions within small Coulomb crystals is investigated. By intense intracavity optical standing wave fields, subwavelength localization of individual ions is achieved for one-, two-, and three-dimensional crystals. Based on these findings, we illustrate numerically how the application of such optical potentials can be used to tailor the normal mode spectra and patterns of multi-dimensional Coulomb crystals. The results represent, among others, important steps towards controlling the crystalline structure of Coulomb crystals, investigating heat transfer processes at the quantum limit and quantum simulations of many-body systems.
△ Less
Submitted 19 March, 2019; v1 submitted 11 September, 2018;
originally announced September 2018.
-
Multi-mode double-bright EIT cooling
Authors:
Nils Scharnhorst,
Javier Cerrillo,
Johannes Kramer,
Ian D. Leroux,
Jannes B. Wübbena,
Alex Retzker,
Piet O. Schmidt
Abstract:
We developed a multi-mode ground state cooling technique based on electromagnetically-induced transparency (EIT). By involving an additional ground and excited state, two individually adjustable bright states together with a dark state are created. While the dark state suppresses carrier scattering, the two bright states are brought into resonance with spectrally separated motional red sidebands.…
▽ More
We developed a multi-mode ground state cooling technique based on electromagnetically-induced transparency (EIT). By involving an additional ground and excited state, two individually adjustable bright states together with a dark state are created. While the dark state suppresses carrier scattering, the two bright states are brought into resonance with spectrally separated motional red sidebands. With this double-bright EIT (D-EIT) cooling scheme, we experimentally demonstrate ground state cooling of all three motional modes of a trapped $^{40}$Ca$^+$ with a single cooling pulse. The approach is scalable to more than two bright states by introducing laser couplings to additional states.
△ Less
Submitted 2 November, 2017;
originally announced November 2017.
-
Experimental and theoretical investigation of a multi-mode cooling scheme using multiple EIT resonances
Authors:
Nils Scharnhorst,
Javier Cerrillo,
Johannes Kramer,
Ian D. Leroux,
Jannes B. Wübbena,
Alex Retzker,
Piet O. Schmidt
Abstract:
We introduce and demonstrate double-bright electromagnetically induced transparency (D-EIT) cooling as a novel approach to EIT cooling. By involving an additional ground state, two bright states can be shifted individually into resonance for cooling of motional modes of frequencies that may be separated by more than the width of a single EIT cooling resonance. This allows three-dimensional ground…
▽ More
We introduce and demonstrate double-bright electromagnetically induced transparency (D-EIT) cooling as a novel approach to EIT cooling. By involving an additional ground state, two bright states can be shifted individually into resonance for cooling of motional modes of frequencies that may be separated by more than the width of a single EIT cooling resonance. This allows three-dimensional ground state cooling of a $^{40}$Ca$^+$ ion trapped in a linear Paul trap with a single cooling pulse. Measured cooling rates and steady-state mean motional quantum numbers for this D-EIT cooling are compared with those of standard EIT cooling as well as concatenated standard EIT cooling pulses for multi-mode cooling. Experimental results are compared to full density matrix calculations. We observe a failure of the theoretical description within the Lamb-Dicke regime that can be overcome by a time-dependent rate theory. Limitations of the different cooling techniques and possible extensions to multi-ion crystals are discussed.
△ Less
Submitted 20 June, 2018; v1 submitted 2 November, 2017;
originally announced November 2017.
-
Localization of ions within one-, two- and three-dimensional Coulomb crystals by a standing wave optical potential
Authors:
Thomas Lauprêtre,
Rasmus B. Linnet,
Ian D. Leroux,
Aurélien Dantan,
Michael Drewsen
Abstract:
We demonstrate light-induced localization of Coulomb-interacting particles in multi-dimensional structures. Subwavelength localization of ions within small multi-dimensional Coulomb crystals by an intracavity optical standing wave field is evidenced by measuring the difference in scattering inside symmetrically red- and blue-detuned optical lattices and is observed even for ions undergoing substan…
▽ More
We demonstrate light-induced localization of Coulomb-interacting particles in multi-dimensional structures. Subwavelength localization of ions within small multi-dimensional Coulomb crystals by an intracavity optical standing wave field is evidenced by measuring the difference in scattering inside symmetrically red- and blue-detuned optical lattices and is observed even for ions undergoing substantial radial micromotion. These results are promising steps towards the structural control of ion Coulomb crystals by optical fields as well as for complex many-body simulations with ion crystals or for the investigation of heat transfer at the nanoscale, and have potential applications for ion-based cavity quantum electrodynamics, cavity optomechanics and ultracold ion chemistry.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
On-Line Estimation of Local Oscillator Noise and Optimisation of Servo Parameters in Atomic Clocks
Authors:
Ian D. Leroux,
Nils Scharnhorst,
Stephan Hannig,
Johannes Kramer,
Lennart Pelzer,
Mariia Stepanova,
Piet O. Schmidt
Abstract:
For atomic frequency standards in which fluctuations of the local oscillator (LO) frequency are the dominant noise source, we examine the role of the servo algorithm that predicts and corrects these frequency fluctuations. We derive the optimal linear prediction algorithm, showing how to measure the relevant spectral properties of the noise and optimise servo parameters while the standard is runni…
▽ More
For atomic frequency standards in which fluctuations of the local oscillator (LO) frequency are the dominant noise source, we examine the role of the servo algorithm that predicts and corrects these frequency fluctuations. We derive the optimal linear prediction algorithm, showing how to measure the relevant spectral properties of the noise and optimise servo parameters while the standard is running, using only the atomic error signal. We find that, for realistic LO noise spectra, a conventional integrating servo with a properly chosen gain performs nearly as well as the optimal linear predictor. Using simple analytical models and numerical simulations, we establish optimum probe times as a function of clock atom number and of the dominant noise type in the local oscillator. We calculate the resulting LO-dependent scaling of achievable clock stability with atom number for product states as well as for maximally-correlated states.
△ Less
Submitted 11 April, 2017; v1 submitted 23 January, 2017;
originally announced January 2017.
-
A tunable low-drift laser stabilized to an atomic reference
Authors:
Tobias Leopold,
Lisa Schmöger,
Stefanie Feuchtenbeiner,
Christian Grebing,
Peter Micke,
Nils Scharnhorst,
Ian D. Leroux,
José R. Crespo López-Urrutia,
Piet O. Schmidt
Abstract:
We present a laser system with a linewidth and long-term frequency stability at the 50 kHz level. It is based on a Ti:Sapphire laser emitting radiation at 882 nm which is referenced to an atomic transition. For this, the length of an evacuated transfer cavity is stabilized to a reference laser at 780 nm locked to the $^{85}$Rb D$_2$-line via modulation transfer spectroscopy. Gapless frequency tuni…
▽ More
We present a laser system with a linewidth and long-term frequency stability at the 50 kHz level. It is based on a Ti:Sapphire laser emitting radiation at 882 nm which is referenced to an atomic transition. For this, the length of an evacuated transfer cavity is stabilized to a reference laser at 780 nm locked to the $^{85}$Rb D$_2$-line via modulation transfer spectroscopy. Gapless frequency tuning of the spectroscopy laser is realized using the sideband locking technique to the transfer cavity. In this configuration, the linewidth of the spectroscopy laser is derived from the transfer cavity, while the long-term stability is derived from the atomic resonance. Using an optical frequency comb, the frequency stability and linewidth of both lasers are characterized by comparison against an active hydrogen maser frequency standard and an ultra-narrow linewidth laser, respectively. The laser system presented here will be used for spectroscopy of the $1s^{2}2s^{2}2p\ ^{2}P_{1/2} -\ ^{2}P_{3/2}$ transition in sympathetically cooled Ar$^{13+}$ ions at 441nm after frequency doubling.
△ Less
Submitted 25 August, 2016; v1 submitted 12 February, 2016;
originally announced February 2016.
-
Analysis of thermal radiation in ion traps for optical frequency standards
Authors:
Miroslav Doležal,
Petr Balling,
Peter B R Nisbet-Jones,
Steven A King,
Jonathan M Jones,
Hugh A Klein,
Patrick Gill,
Thomas Lindvall,
Anders E Wallin,
Mikko Merimaa,
Christian Tamm,
Christian Sanner,
Nils Huntemann,
Nils Scharnhorst,
Ian D Leroux,
Piet O Schmidt,
Tobias Burgermeister,
Tanja E Mehlstäubler,
Ekkehard Peik
Abstract:
In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of…
▽ More
In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for 5 ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10-18 range for optical clocks based on the Sr+ and Yb+ E2 transitions, and even lower for Yb+ E3, In+ and Al+. Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.
△ Less
Submitted 6 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
High-bandwidth transfer of phase stability through a fiber frequency comb
Authors:
Nils Scharnhorst,
Jannes B. Wübbena,
Stephan Hannig,
Kornelius Jakobsen,
Johannes Kramer,
Ian D. Leroux,
Piet O. Schmidt
Abstract:
We demonstrate phase locking of a 729 nm diode laser to a 1542 nm master laser via an erbium-doped-fiber frequency comb, using a transfer-oscillator feedforward scheme which suppresses the effect of comb noise in an unprecedented 1.8 MHz bandwidth. We illustrate its performance by carrying out coherent manipulations of a trapped calcium ion with 99 % fidelity even at few-microsecond timescales. We…
▽ More
We demonstrate phase locking of a 729 nm diode laser to a 1542 nm master laser via an erbium-doped-fiber frequency comb, using a transfer-oscillator feedforward scheme which suppresses the effect of comb noise in an unprecedented 1.8 MHz bandwidth. We illustrate its performance by carrying out coherent manipulations of a trapped calcium ion with 99 % fidelity even at few-microsecond timescales. We thus demonstrate that transfer-oscillator locking can provide sufficient phase stability for high-fidelity quantum logic manipulation even without pre-stabilization of the slave diode laser.
△ Less
Submitted 30 June, 2015; v1 submitted 8 May, 2015;
originally announced May 2015.
-
Quantum Algorithmic Readout in Multi-Ion Clocks
Authors:
Marius Schulte,
Niels Lörch,
Ian D. Leroux,
Piet O. Schmidt,
Klemens Hammerer
Abstract:
Optical clocks based on ensembles of trapped ions offer the perspective of record frequency uncertainty with good short-term stability. Most suitable atomic species lack closed transitions for fast detection such that the clock signal has to be read out indirectly through transferring the quantum state of clock ions to co-trapped logic ions by means of quantum logic operations. For ensembles of cl…
▽ More
Optical clocks based on ensembles of trapped ions offer the perspective of record frequency uncertainty with good short-term stability. Most suitable atomic species lack closed transitions for fast detection such that the clock signal has to be read out indirectly through transferring the quantum state of clock ions to co-trapped logic ions by means of quantum logic operations. For ensembles of clock ions existing methods for quantum logic readout require a linear overhead in either time or the number of logic ions. Here we report a quantum algorithmic readout whose overhead scales logarithmically with the number of clock ions in both of these respects. We show that the readout algorithm can be implemented with a single application of a multi-species quantum gate, which we describe in detail for a crystal of Aluminum and Calcium ions.
△ Less
Submitted 14 January, 2016; v1 submitted 26 January, 2015;
originally announced January 2015.
-
Sub-Micron Positioning of Trapped Ions with Respect to the Absolute Center of a Standing Wave Cavity Field
Authors:
Rasmus B. Linnet,
Ian D. Leroux,
Aurélien Dantan,
Michael Drewsen
Abstract:
We demonstrate that it is possible, with sub-micron precision, to locate the absolute center of a Fabry-Pérot resonator oriented along the rf-field-free axis of a linear Paul trap through the application of two simultaneously resonating optical fields. In particular, we apply a probe field, which is near-resonant with an electronic transition of trapped ions, simultaneously with an off-resonant st…
▽ More
We demonstrate that it is possible, with sub-micron precision, to locate the absolute center of a Fabry-Pérot resonator oriented along the rf-field-free axis of a linear Paul trap through the application of two simultaneously resonating optical fields. In particular, we apply a probe field, which is near-resonant with an electronic transition of trapped ions, simultaneously with an off-resonant strong field acting as a periodic AC Stark-shifting potential. Through the resulting spatially modulated fluorescence signal we can find the cavity center of an 11.7 mm-long symmetric Fabry- Pérot cavity with a precision of $\pm$135 nm, which is smaller than the periodicity of the individual standing wave fields. This can e.g. be used to position the minimum of the axial trap potential with respect to the center of the cavity at any location along the cavity mode.
△ Less
Submitted 30 October, 2013;
originally announced October 2013.
-
Precision spectroscopy by photon-recoil signal amplification
Authors:
Yong Wan,
Florian Gebert,
Jannes B. Wübbena,
Nils Scharnhorst,
Sana Amairi,
Ian D. Leroux,
Börge Hemmerling,
Niels Lörch,
Klemens Hammerer,
Piet O. Schmidt
Abstract:
Precision spectroscopy of atomic and molecular ions offers a window to new physics, but is typically limited to species with a cycling transition for laser cooling and detection. Quantum logic spectroscopy has overcome this limitation for species with long-lived excited states. Here, we extend quantum logic spectroscopy to fast, dipole-allowed transitions and apply it to perform an absolute freque…
▽ More
Precision spectroscopy of atomic and molecular ions offers a window to new physics, but is typically limited to species with a cycling transition for laser cooling and detection. Quantum logic spectroscopy has overcome this limitation for species with long-lived excited states. Here, we extend quantum logic spectroscopy to fast, dipole-allowed transitions and apply it to perform an absolute frequency measurement. We detect the absorption of photons by the spectroscopically investigated ion through the photon recoil imparted on a co-trapped ion of a different species, on which we can perform efficient quantum logic detection techniques. This amplifies the recoil signal from a few absorbed photons to thousands of fluorescence photons. We resolve the line center of a dipole-allowed transition in 40Ca+ to 1/300 of its observed linewidth, rendering this measurement one of the most accurate of a broad transition. The simplicity and versatility of this approach enables spectroscopy of many previously inaccessible species.
△ Less
Submitted 7 February, 2014; v1 submitted 26 September, 2013;
originally announced September 2013.
-
Pinning an Ion with an Intracavity Optical Lattice
Authors:
Rasmus B. Linnet,
Ian D. Leroux,
Mathieu Marciante,
Aurélien Dantan,
Michael Drewsen
Abstract:
We report one-dimensional pinning of a single ion by an optical lattice. The lattice potential is produced by a standing-wave cavity along the rf-field-free axis of a linear Paul trap. The ion's localization is detected by measuring its fluorescence when excited by standing-wave fields with the same period, but different spatial phases. The experiments agree with an analytical model of the localiz…
▽ More
We report one-dimensional pinning of a single ion by an optical lattice. The lattice potential is produced by a standing-wave cavity along the rf-field-free axis of a linear Paul trap. The ion's localization is detected by measuring its fluorescence when excited by standing-wave fields with the same period, but different spatial phases. The experiments agree with an analytical model of the localization process, which we test against numerical simulations. For the best localization achieved, the ion's average coupling to the cavity field is enhanced from 50% to 81(3)% of its maximum possible value, and we infer that the ion is bound in a lattice well with over 97% probability.
△ Less
Submitted 9 December, 2012; v1 submitted 20 August, 2012;
originally announced August 2012.
-
Collective state measurement of mesoscopic ensembles with single-atom resolution
Authors:
Hao Zhang,
Robert McConnell,
Senka Ćuk,
Qian Lin,
Monika H. Schleier-Smith,
Ian D. Leroux,
Vladan Vuletić
Abstract:
For mesoscopic ensembles containing 100 or more atoms we measure the total atom number and the number of atoms in a specific hyperfine state with single-atom resolution. The measurement detects the atom-induced shift of the resonance frequency of an optical cavity containing the ensemble. This work extends the range of cavity-based detection with single-atom resolution by more than an order of mag…
▽ More
For mesoscopic ensembles containing 100 or more atoms we measure the total atom number and the number of atoms in a specific hyperfine state with single-atom resolution. The measurement detects the atom-induced shift of the resonance frequency of an optical cavity containing the ensemble. This work extends the range of cavity-based detection with single-atom resolution by more than an order of magnitude in atom number, and provides the readout capability necessary for Heisenberg-limited interferometry with atomic ensembles.
△ Less
Submitted 28 September, 2012; v1 submitted 14 March, 2012;
originally announced March 2012.
-
Unitary Cavity Spin Squeezing by Quantum Erasure
Authors:
Ian D. Leroux,
Monika H. Schleier-Smith,
Hao Zhang,
Vladan Vuletić
Abstract:
Deterministic light-induced spin squeezing in an atomic gas is limited by photon shot noise or, equivalently, by atomic state information esca** with the light field mediating the effective atom-atom interaction. We show theoretically that the performance of cavity spin squeezing [M.H. Schleier-Smith, I.D. Leroux, and V. Vuletić, Phys. Rev. A 81, 021804(R) (2010)] can be substantially improved b…
▽ More
Deterministic light-induced spin squeezing in an atomic gas is limited by photon shot noise or, equivalently, by atomic state information esca** with the light field mediating the effective atom-atom interaction. We show theoretically that the performance of cavity spin squeezing [M.H. Schleier-Smith, I.D. Leroux, and V. Vuletić, Phys. Rev. A 81, 021804(R) (2010)] can be substantially improved by erasing the light-atom entanglement, and propose several methods for doing so. Accounting for light scattering into free space, quantum erasure improves the scaling of cavity squeezing from S^(-1/2) to S^(-2/3), where S is the total atomic spin.
△ Less
Submitted 5 January, 2012; v1 submitted 17 September, 2011;
originally announced September 2011.
-
Optomechanical Cavity Cooling of an Atomic Ensemble
Authors:
Monika H. Schleier-Smith,
Ian D. Leroux,
Hao Zhang,
Mackenzie A. Van Camp,
Vladan Vuletic
Abstract:
We demonstrate cavity sideband cooling of a single collective motional mode of an atomic ensemble down to a mean phonon occupation number of 2.0(-0.3/+0.9). Both this minimum occupation number and the observed cooling rate are in good agreement with an optomechanical model. The cooling rate constant is proportional to the total photon scattering rate by the ensemble, demonstrating the cooperative…
▽ More
We demonstrate cavity sideband cooling of a single collective motional mode of an atomic ensemble down to a mean phonon occupation number of 2.0(-0.3/+0.9). Both this minimum occupation number and the observed cooling rate are in good agreement with an optomechanical model. The cooling rate constant is proportional to the total photon scattering rate by the ensemble, demonstrating the cooperative character of the light-emission-induced cooling process. We deduce fundamental limits to cavity-cooling either the collective mode or, sympathetically, the single-atom degrees of freedom.
△ Less
Submitted 23 July, 2011; v1 submitted 24 April, 2011;
originally announced April 2011.
-
Microchip-Based Trapped-Atom Clocks
Authors:
Vladan Vuletic,
Ian D. Leroux,
Monika H. Schleier-Smith
Abstract:
This is a chapter of a recently published book entitled Atom Chips, edited by Jakob Reichel and Vladan Vuletic. The contents of this chapter include: Basic Principles; Atomic-Fountain versus Trapped-Atom Clocks; Optical-Transition Clocks versus Microwave Clocks; Clocks with Magnetically Trapped Atoms--Fundamental Limits and Experimental Demonstrations; Readout in Trapped-Atom Clocks; and Spin Sque…
▽ More
This is a chapter of a recently published book entitled Atom Chips, edited by Jakob Reichel and Vladan Vuletic. The contents of this chapter include: Basic Principles; Atomic-Fountain versus Trapped-Atom Clocks; Optical-Transition Clocks versus Microwave Clocks; Clocks with Magnetically Trapped Atoms--Fundamental Limits and Experimental Demonstrations; Readout in Trapped-Atom Clocks; and Spin Squeezing.
△ Less
Submitted 20 April, 2011;
originally announced April 2011.
-
Interaction between Atomic Ensembles and Optical Resonators: Classical Description
Authors:
Haruka Tanji-Suzuki,
Ian D. Leroux,
Monika H. Schleier-Smith,
Marko Cetina,
Andrew T. Grier,
Jonathan Simon,
Vladan Vuletic
Abstract:
Many effects in the interaction between atoms and a cavity that are usually de-scribed in quantum mechanical terms (cavity quantum electrodynamics, cavity QED) can be understood and quantitatively analyzed within a classical framework. We adopt such a classical picture of a radiating dipole oscillator to derive explicit ex- pressions for the coupling of single atoms and atomic ensembles to Gaussia…
▽ More
Many effects in the interaction between atoms and a cavity that are usually de-scribed in quantum mechanical terms (cavity quantum electrodynamics, cavity QED) can be understood and quantitatively analyzed within a classical framework. We adopt such a classical picture of a radiating dipole oscillator to derive explicit ex- pressions for the coupling of single atoms and atomic ensembles to Gaussian modes in free space and in an optical resonator. The cooperativity parameter of cavity QED is shown to play a central role, and is given a geometrical interpretation. The classical analysis yields transparent, intuitive results that are useful for analyzing applications of cavity QED such as atom detection and counting, cavity cooling, cavity spin squeezing, cavity spin optomechanics, or phase transitions associated with the self-organization of the ensemble-light system.
△ Less
Submitted 20 November, 2011; v1 submitted 18 April, 2011;
originally announced April 2011.
-
Orientation-Dependent Entanglement Lifetime in a Squeezed Atomic Clock
Authors:
Ian D. Leroux,
Monika H. Schleier-Smith,
Vladan Vuletić
Abstract:
We study experimentally the lifetime of a special class of entangled states in an atomic clock, squeezed spin states. In the presence of anisotropic noise, their lifetime is strongly dependent on squeezing orientation. We measure the Allan deviation spectrum of a clock operated with a phase-squeezed input state. For integration times up to 50 s the squeezed clock achieves a given precision 2.8(…
▽ More
We study experimentally the lifetime of a special class of entangled states in an atomic clock, squeezed spin states. In the presence of anisotropic noise, their lifetime is strongly dependent on squeezing orientation. We measure the Allan deviation spectrum of a clock operated with a phase-squeezed input state. For integration times up to 50 s the squeezed clock achieves a given precision 2.8(3) times faster than a clock operating at the standard quantum limit.
△ Less
Submitted 10 April, 2010;
originally announced April 2010.
-
Implementation of Cavity Squeezing of a Collective Atomic Spin
Authors:
Ian D. Leroux,
Monika H. Schleier-Smith,
Vladan Vuletić
Abstract:
We squeeze unconditionally the collective spin of a dilute ensemble of laser-cooled rubidium-87 atoms using their interaction with a driven optical resonator. The shape and size of the resulting spin uncertainty region are well described by a simple analytical model [M.H.S., I.D.L., V.V., arXiv:0911.3936] through two orders of magnitude in the effective interaction strength, without free paramet…
▽ More
We squeeze unconditionally the collective spin of a dilute ensemble of laser-cooled rubidium-87 atoms using their interaction with a driven optical resonator. The shape and size of the resulting spin uncertainty region are well described by a simple analytical model [M.H.S., I.D.L., V.V., arXiv:0911.3936] through two orders of magnitude in the effective interaction strength, without free parameters. We deterministically generate states with up to 5.6(6) dB of metrologically relevant spin squeezing on the canonical rubidium-87 hyperfine clock transition.
△ Less
Submitted 2 February, 2010; v1 submitted 20 November, 2009;
originally announced November 2009.
-
Squeezing the Collective Spin of a Dilute Atomic Ensemble by Cavity Feedback
Authors:
Monika H. Schleier-Smith,
Ian D. Leroux,
Vladan Vuletić
Abstract:
We propose and analyze a simple method to squeeze dynamically and unconditionally the collective spin of a dilute atomic ensemble by interaction with a driven mode of an optical resonator, as recently demonstrated [I. D. L., M. H. S., and V. V., Phys. Rev. Lett. 104, 073602 (2010)]. We show that substantial squeezing can be achieved in the regime of strong collective ensemble-resonator coupling.…
▽ More
We propose and analyze a simple method to squeeze dynamically and unconditionally the collective spin of a dilute atomic ensemble by interaction with a driven mode of an optical resonator, as recently demonstrated [I. D. L., M. H. S., and V. V., Phys. Rev. Lett. 104, 073602 (2010)]. We show that substantial squeezing can be achieved in the regime of strong collective ensemble-resonator coupling. The squeezing is ultimately limited either by photon emission into free space or by the curvature of the Bloch sphere. We derive both limits and show where each prevails.
△ Less
Submitted 18 February, 2010; v1 submitted 19 November, 2009;
originally announced November 2009.
-
States of an Ensemble of Two-Level Atoms with Reduced Quantum Uncertainty
Authors:
Monika H. Schleier-Smith,
Ian D. Leroux,
Vladan Vuletić
Abstract:
We generate entangled states of an ensemble of 5*10^4 rubidium-87 atoms by optical quantum nondemolition measurement. The resonator-enhanced measurement leaves the atomic ensemble, prepared in a superposition of hyperfine clock levels, in a squeezed spin state. By comparing the resulting reduction of quantum projection noise (up to 8.8(8) dB) with the concomitant reduction of coherence, we demon…
▽ More
We generate entangled states of an ensemble of 5*10^4 rubidium-87 atoms by optical quantum nondemolition measurement. The resonator-enhanced measurement leaves the atomic ensemble, prepared in a superposition of hyperfine clock levels, in a squeezed spin state. By comparing the resulting reduction of quantum projection noise (up to 8.8(8) dB) with the concomitant reduction of coherence, we demonstrate a clock input state with spectroscopic sensitivity 3.0(8) dB beyond the standard quantum limit.
△ Less
Submitted 18 February, 2010; v1 submitted 14 October, 2008;
originally announced October 2008.
-
Trap** Fermionic $^{40}$K and Bosonic $^{87}$Rb on a Chip
Authors:
S. Aubin,
M. H. T. Extavour,
S. Myrskog,
L. J. LeBlanc,
J. Esteve,
S. Singh,
P. Scrutton,
D. McKay,
R. McKenzie,
I. D. Leroux,
A. Stummer,
J. H. Thywissen
Abstract:
We demonstrate the loading of a Bose-Fermi mixture into a microfabricated magnetic trap. In a single-chamber vacuum system, laser-cooled atoms are transported to the surface of a substrate on which gold wires have been microfabricated. The magnetic field minimum formed near these current-carrying wires is used to confine up to $6\times10^4$ neutral $^{40}$K atoms. In addition, we can simultaneou…
▽ More
We demonstrate the loading of a Bose-Fermi mixture into a microfabricated magnetic trap. In a single-chamber vacuum system, laser-cooled atoms are transported to the surface of a substrate on which gold wires have been microfabricated. The magnetic field minimum formed near these current-carrying wires is used to confine up to $6\times10^4$ neutral $^{40}$K atoms. In addition, we can simultaneously load $2 \times 10^5$ $^{87}$Rb atoms, demonstrating the confinement of two distinct elements with such a trap. In a sequence optimized for $^{87}$Rb alone, we observe up to $1 \times 10^7$ trapped atoms. We describe in detail the experimental apparatus, and discuss prospects for evaporative cooling towards quantum degeneracy in both species.
△ Less
Submitted 5 August, 2005; v1 submitted 8 February, 2005;
originally announced February 2005.