-
Achromatic, planar Fresnel-Reflector for a Single-beam Magneto-optical Trap
Authors:
Saskia Bondza,
Tobias Leopold,
Roman Schwarz,
Christian Lisdat
Abstract:
We present a novel achromatic, planar, periodic mirror structure for single-beam magneto-optical trap** and demonstrate its use in first- and second-stage cooling and trap** for different isotopes of strontium. We refer to it as Fresnel MOT as the structure is inspired by Fresnel lenses. By design, it avoids many of the problems that arise for multi-color cooling using planar structures based…
▽ More
We present a novel achromatic, planar, periodic mirror structure for single-beam magneto-optical trap** and demonstrate its use in first- and second-stage cooling and trap** for different isotopes of strontium. We refer to it as Fresnel MOT as the structure is inspired by Fresnel lenses. By design, it avoids many of the problems that arise for multi-color cooling using planar structures based on diffraction gratings, which have been the dominant planar structures to be used for single-beam trap** thus far. In addition to a complex design process and cost-intensive fabrication, diffraction gratings suffer from their inherent chromaticity, which causes different axial displacements of trap volumes for the different wavelengths and necessitates tradeoffs in their diffraction properties and achievable trap depths. In contrast, the Fresnel reflector structure presented here is a versatile, easy-to-manufacture device that combines achromatic beam steering with the advantages of a planar architecture. It enables miniaturizing trap** systems for alkaline-earth-like atoms with multiple cooling transitions as well as multi-species trap** in the ideal tetrahedral configuration and within the same volume above the structure. Our design presents a novel approach for the miniaturization of cold-atom systems based on single-beam MOTs and enables the widespread adoption of these systems.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
An Optical Atomic Clock Based on a Highly Charged Ion
Authors:
Steven A. King,
Lukas J. Spieß,
Peter Micke,
Alexander Wilzewski,
Tobias Leopold,
Erik Benkler,
Richard Lange,
Nils Huntemann,
Andrey Surzhykov,
Vladimir A. Yerokhin,
José R. Crespo López-Urrutia,
Piet O. Schmidt
Abstract:
Optical atomic clocks are the most accurate measurement devices ever constructed and have found many applications in fundamental science and technology. The use of highly charged ions (HCI) as a new class of references for highest accuracy clocks and precision tests of fundamental physics has long been motivated by their extreme atomic properties and reduced sensitivity to perturbations from exter…
▽ More
Optical atomic clocks are the most accurate measurement devices ever constructed and have found many applications in fundamental science and technology. The use of highly charged ions (HCI) as a new class of references for highest accuracy clocks and precision tests of fundamental physics has long been motivated by their extreme atomic properties and reduced sensitivity to perturbations from external electric and magnetic fields compared to singly charged ions or neutral atoms. Here we present the first realisation of this new class of clocks, based on an optical magnetic-dipole transition in Ar$^{13+}$. Its comprehensively evaluated systematic frequency uncertainty of $2.2\times10^{-17}$ is comparable to that of many optical clocks in operation. From clock comparisons we improve by eight and nine orders of magnitude upon the uncertainties for the absolute transition frequency and isotope shift ($^{40}$Ar vs. $^{36}$Ar), respectively. These measurements allow us to probe the largely unexplored quantum electrodynamic nuclear recoil, presented as part of improved calculations of the isotope shift which reduce the uncertainty of previous theory by a factor of three. This work establishes forbidden optical transitions in HCI as references for cutting-edge optical clocks and future high-sensitivity searches for physics beyond the standard model.
△ Less
Submitted 6 September, 2023; v1 submitted 25 May, 2022;
originally announced May 2022.
-
Two-color grating magneto-optical trap for narrow-line laser cooling
Authors:
Saskia Bondza,
Christian Lisdat,
Stefanie Kroker,
Tobias Leopold
Abstract:
We demonstrate for the first time the two-color cooling and trap** of alkaline-earth atoms in a grating magneto-optical trap (gMOT). The trap is formed by a single incident laser beam together with four secondary beams that are generated via diffraction from a nanostructured wafer. A grating structure for a gMOT operating with strontium atoms is optimized and fabricated. We trap $10^6$ $^{88}$Sr…
▽ More
We demonstrate for the first time the two-color cooling and trap** of alkaline-earth atoms in a grating magneto-optical trap (gMOT). The trap is formed by a single incident laser beam together with four secondary beams that are generated via diffraction from a nanostructured wafer. A grating structure for a gMOT operating with strontium atoms is optimized and fabricated. We trap $10^6$ $^{88}$Sr atoms on the $^1$S$_0$ $\rightarrow$ $^1$P$_1$ transition at $461\;\mathrm{nm}$ and transfer $25\;\%$ of these atoms to the second cooling stage on the narrower $^1$S$_0$ $\rightarrow$ $^3$P$_1$ intercombination transition at $689\;\mathrm{nm}$, preparing a sample of $2.5\times 10^5$ atoms at $5\;μ$K. These results demonstrate for the first time the applicability of the gMOT technology in conjunction with two widely differing wavelengths and enable the continued miniaturization of alkaline-earth based quantum technologies like optical atomic clocks.
△ Less
Submitted 16 December, 2021;
originally announced December 2021.
-
Algorithmic Ground-state Cooling of Weakly-Coupled Oscillators using Quantum Logic
Authors:
Steven A. King,
Lukas J. Spieß,
Peter Micke,
Alexander Wilzewski,
Tobias Leopold,
José R. Crespo López-Urrutia,
Piet O. Schmidt
Abstract:
Most ions lack the fast, cycling transitions that are necessary for direct laser cooling. In most cases, they can still be cooled sympathetically through their Coulomb interaction with a second, coolable ion species confined in the same potential. If the charge-to-mass ratios of the two ion types are too mismatched, the cooling of certain motional degrees of freedom becomes difficult. This limits…
▽ More
Most ions lack the fast, cycling transitions that are necessary for direct laser cooling. In most cases, they can still be cooled sympathetically through their Coulomb interaction with a second, coolable ion species confined in the same potential. If the charge-to-mass ratios of the two ion types are too mismatched, the cooling of certain motional degrees of freedom becomes difficult. This limits both the achievable fidelity of quantum gates and the spectroscopic accuracy. Here we introduce a novel algorithmic cooling protocol for transferring phonons from poorly- to efficiently-cooled modes. We demonstrate it experimentally by simultaneously bringing two motional modes of a Be$^{+}$-Ar$^{13+}$ mixed Coulomb crystal close to their zero-point energies, despite the weak coupling between the ions. We reach the lowest temperature reported for a highly charged ion, with a residual temperature of only $T\lesssim200~\mathrm{μK}$ in each of the two modes, corresponding to a residual mean motional phonon number of $\langle n \rangle \lesssim 0.4$. Combined with the lowest observed electric field noise in a radiofrequency ion trap, these values enable an optical clock based on a highly charged ion with fractional systematic uncertainty below the $10^{-18}$ level. Our scheme is also applicable to (anti-)protons, molecular ions, macroscopic charged particles, and other highly charged ion species, enabling reliable preparation of their motional quantum ground states in traps.
△ Less
Submitted 25 February, 2021; v1 submitted 24 February, 2021;
originally announced February 2021.
-
An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions
Authors:
J. Stark,
C. Warnecke,
S. Bogen,
S. Chen,
E. A. Dijck,
S. Kühn,
M. K. Rosner,
A. Graf,
J. Nauta,
J. -H. Oelmann,
L. Schmöger,
M. Schwarz,
D. Liebert,
L. J. Spieß,
S. A. King,
T. Leopold,
P. Micke,
P. O. Schmidt,
T. Pfeifer,
J. R. Crespo López-Urrutia
Abstract:
We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of $Q\approx2.3\times 10^5$ at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rate…
▽ More
We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of $Q\approx2.3\times 10^5$ at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts which limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron beam ion trap and deceleration beamline supplying highly charged ions (HCI), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole mass filter with HCI, and trap** of Doppler-cooled ${}^9\text{Be}^+$ Coulomb crystals.
△ Less
Submitted 4 February, 2021;
originally announced February 2021.
-
Coherent laser spectroscopy of highly charged ions using quantum logic
Authors:
P. Micke,
T. Leopold,
S. A. King,
E. Benkler,
L. J. Spieß,
L. Schmöger,
M. Schwarz,
J. R. Crespo López-Urrutia,
P. O. Schmidt
Abstract:
Precision spectroscopy of atomic systems is an invaluable tool for the advancement of our understanding of fundamental interactions and symmetries. Recently, highly charged ions (HCI) have been proposed for sensitive tests of physics beyond the Standard Model and as candidates for high-accuracy atomic clocks. However, the implementation of these ideas has been hindered by the parts-per-million lev…
▽ More
Precision spectroscopy of atomic systems is an invaluable tool for the advancement of our understanding of fundamental interactions and symmetries. Recently, highly charged ions (HCI) have been proposed for sensitive tests of physics beyond the Standard Model and as candidates for high-accuracy atomic clocks. However, the implementation of these ideas has been hindered by the parts-per-million level spectroscopic accuracies achieved to date. Here, we cool a trapped HCI to the lowest reported temperatures, and introduce coherent laser spectroscopy on HCI with an eight orders of magnitude leap in precision. We probe the forbidden optical transition in $^{40}$Ar$^{13+}$ at 441 nm using quantum-logic spectroscopy and measure both its excited-state lifetime and $g$-factor. Our work ultimately unlocks the potential of HCI, a large, ubiquitous atomic class, for quantum information processing, novel frequency standards, and highly sensitive tests of fundamental physics, such as searching for dark matter candidates or violations of fundamental symmetries.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
Closed-cycle, low-vibration 4 K cryostat for ion traps and other applications
Authors:
P. Micke,
J. Stark,
S. A. King,
T. Leopold,
T. Pfeifer,
L. Schmöger,
M. Schwarz,
L. J. Spieß,
P. O. Schmidt,
J. R. Crespo López-Urrutia
Abstract:
In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for experiments with highly charged ions, quantum computation, and optical clocks. We have developed a novel cryostat continuously refrigerated with a pulse-tube cryoc…
▽ More
In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for experiments with highly charged ions, quantum computation, and optical clocks. We have developed a novel cryostat continuously refrigerated with a pulse-tube cryocooler and providing the lowest vibration level reported for such a closed-cycle system with 1 W cooling power for a <5 K experiment. A decoupling system suppresses vibrations from the cryocooler by three orders of magnitude down to a level of 10 nm peak amplitudes in the horizontal plane. Heat loads of about 40 W (at 45 K) and 1 W (at 4 K) are transferred from an experimental chamber, mounted on an optical table, to the cryocooler through a vacuum-insulated massive 120 kg inertial copper pendulum. The 1.4 m long pendulum allows installation of the cryocooler in a separate, acoustically isolated machine room. In the laser laboratory, we measured the residual vibrations using an interferometric setup. The positioning of the 4 K elements is reproduced to better than a few micrometer after a full thermal cycle to room temperature. Extreme high vacuum on the $10^{-15}$ mbar level is achieved. In collaboration with the Max-Planck-Intitut für Kernphysik (MPIK), such a setup is now in operation at the Physikalisch-Technische Bundesanstalt (PTB) for a next-generation optical clock experiment using highly charged ions.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions
Authors:
Tobias Leopold,
Steven A. King,
Peter Micke,
Amado Bautista-Salvador,
Jan C. Heip,
Christian Ospelkaus,
José R. Crespo López-Urrutia,
Piet O. Schmidt
Abstract:
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single $^9$Be$^+$ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of t…
▽ More
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single $^9$Be$^+$ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar$^{13+}$ (Ar XIV) ions concurrently with single Be$^+$ ions, a key prerequisite for the first quantum logic spectroscopy of a highly charged ion.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
A self-injection locked DBR laser for laser cooling of beryllium ions
Authors:
Steven A. King,
Tobias Leopold,
Premjith Thekkeppatt,
Piet O. Schmidt
Abstract:
We present a simple, robust, narrow-linewidth, frequency-doubled semiconductor laser source suitable for laser cooling and repum** of $^9$Be$^+$ ions. A distributed Bragg reflector (DBR) laser diode operating at 626 nm is self-injection-locked to a frequency doubling cavity via phase-stabilised optical feedback when the laser is resonant with the cavity mode. The short-term laser instability is…
▽ More
We present a simple, robust, narrow-linewidth, frequency-doubled semiconductor laser source suitable for laser cooling and repum** of $^9$Be$^+$ ions. A distributed Bragg reflector (DBR) laser diode operating at 626 nm is self-injection-locked to a frequency doubling cavity via phase-stabilised optical feedback when the laser is resonant with the cavity mode. The short-term laser instability is reduced from the MHz-level to approximately 20 kHz by the injection process, thus eliminating the need for a high-bandwidth feedback loop to suppress the otherwise troublesome high-frequency laser noise. Long-term stability of the laser frequency is achieved by feeding back to the length of the enhancement cavity utilising an electro-optic frequency comb generator to produce a beatnote with a laser that is detuned by 98 GHz. Long-term injection locking and frequency stabilisation via a wavemeter are ensured using automatic relocking algorithms.
△ Less
Submitted 25 May, 2018;
originally announced May 2018.
-
A tunable low-drift laser stabilized to an atomic reference
Authors:
Tobias Leopold,
Lisa Schmöger,
Stefanie Feuchtenbeiner,
Christian Grebing,
Peter Micke,
Nils Scharnhorst,
Ian D. Leroux,
José R. Crespo López-Urrutia,
Piet O. Schmidt
Abstract:
We present a laser system with a linewidth and long-term frequency stability at the 50 kHz level. It is based on a Ti:Sapphire laser emitting radiation at 882 nm which is referenced to an atomic transition. For this, the length of an evacuated transfer cavity is stabilized to a reference laser at 780 nm locked to the $^{85}$Rb D$_2$-line via modulation transfer spectroscopy. Gapless frequency tuni…
▽ More
We present a laser system with a linewidth and long-term frequency stability at the 50 kHz level. It is based on a Ti:Sapphire laser emitting radiation at 882 nm which is referenced to an atomic transition. For this, the length of an evacuated transfer cavity is stabilized to a reference laser at 780 nm locked to the $^{85}$Rb D$_2$-line via modulation transfer spectroscopy. Gapless frequency tuning of the spectroscopy laser is realized using the sideband locking technique to the transfer cavity. In this configuration, the linewidth of the spectroscopy laser is derived from the transfer cavity, while the long-term stability is derived from the atomic resonance. Using an optical frequency comb, the frequency stability and linewidth of both lasers are characterized by comparison against an active hydrogen maser frequency standard and an ultra-narrow linewidth laser, respectively. The laser system presented here will be used for spectroscopy of the $1s^{2}2s^{2}2p\ ^{2}P_{1/2} -\ ^{2}P_{3/2}$ transition in sympathetically cooled Ar$^{13+}$ ions at 441nm after frequency doubling.
△ Less
Submitted 25 August, 2016; v1 submitted 12 February, 2016;
originally announced February 2016.