Sleep Apnea and Respiratory Anomaly Detection from a Wearable Band and Oxygen Saturation
Authors:
Wolfgang Ganglberger,
Abigail A. Bucklin,
Ryan A. Tesh,
Madalena Da Silva Cardoso,
Haoqi Sun,
Michael J. Leone,
Luis Paixao,
Ezhil Panneerselvam,
Elissa M. Ye,
B. Taylor Thompson,
Oluwaseun Akeju,
David Kuller,
Robert J. Thomas,
M. Brandon Westover
Abstract:
Objective: Sleep related respiratory abnormalities are typically detected using polysomnography. There is a need in general medicine and critical care for a more convenient method to automatically detect sleep apnea from a simple, easy-to-wear device. The objective is to automatically detect abnormal respiration and estimate the Apnea-Hypopnea-Index (AHI) with a wearable respiratory device, compar…
▽ More
Objective: Sleep related respiratory abnormalities are typically detected using polysomnography. There is a need in general medicine and critical care for a more convenient method to automatically detect sleep apnea from a simple, easy-to-wear device. The objective is to automatically detect abnormal respiration and estimate the Apnea-Hypopnea-Index (AHI) with a wearable respiratory device, compared to an SpO2 signal or polysomnography using a large (n = 412) dataset serving as ground truth. Methods: Simultaneously recorded polysomnographic (PSG) and wearable respiratory effort data were used to train and evaluate models in a cross-validation fashion. Time domain and complexity features were extracted, important features were identified, and a random forest model employed to detect events and predict AHI. Four models were trained: one each using the respiratory features only, a feature from the SpO2 (%)-signal only, and two additional models that use the respiratory features and the SpO2 (%)-feature, one allowing a time lag of 30 seconds between the two signals. Results: Event-based classification resulted in areas under the receiver operating characteristic curves of 0.94, 0.86, 0.82, and areas under the precision-recall curves of 0.48, 0.32, 0.51 for the models using respiration and SpO2, respiration-only, and SpO2-only respectively. Correlation between expert-labelled and predicted AHI was 0.96, 0.78, and 0.93, respectively. Conclusions: A wearable respiratory effort signal with or without SpO2 predicted AHI accurately. Given the large dataset and rigorous testing design, we expect our models are generalizable to evaluating respiration in a variety of environments, such as at home and in critical care.
△ Less
Submitted 23 February, 2021;
originally announced February 2021.
-
Clinically Relevant Mediation Analysis using Controlled Indirect Effect
Authors:
Haoqi Sun,
Michael J. Leone,
Lin Liu,
Shabani S. Mukerji,
Gregory K. Robbins,
M. Brandon Westover
Abstract:
Mediation analysis allows one to use observational data to estimate the importance of each potential mediating pathway involved in the causal effect of an exposure on an outcome. However, current approaches to mediation analysis with multiple mediators either involve assumptions not verifiable by experiments, or estimate the effect when mediators are manipulated jointly which precludes the practic…
▽ More
Mediation analysis allows one to use observational data to estimate the importance of each potential mediating pathway involved in the causal effect of an exposure on an outcome. However, current approaches to mediation analysis with multiple mediators either involve assumptions not verifiable by experiments, or estimate the effect when mediators are manipulated jointly which precludes the practical design of experiments due to curse of dimensionality, or are difficult to interpret when arbitrary causal dependencies are present. We propose a method for mediation analysis for multiple manipulable mediators with arbitrary causal dependencies. The proposed method is clinically relevant because the decomposition of the total effect does not involve effects under cross-world assumptions and focuses on the effects after manipulating (i.e. treating) one single mediator, which is more relevant in a clinical scenario. We illustrate the approach using simulated data, the "framing" dataset from political science, and the HIV-Brain Age dataset from a clinical retrospective cohort study. Our results provide potential guidance for clinical practitioners to make justified choices to manipulate one of the mediators to optimize the outcome.
△ Less
Submitted 20 June, 2020;
originally announced June 2020.
-
Sleep Staging from Electrocardiography and Respiration with Deep Learning
Authors:
Haoqi Sun,
Wolfgang Ganglberger,
Ezhil Panneerselvam,
Michael J. Leone,
Syed A. Quadri,
Balaji Goparaju,
Ryan A. Tesh,
Oluwaseun Akeju,
Robert J. Thomas,
M. Brandon Westover
Abstract:
Study Objective: Sleep is reflected not only in the electroencephalogram but also in heart rhythms and breathing patterns. Therefore, we hypothesize that it is possible to accurately stage sleep based on the electrocardiogram (ECG) and respiratory signals. Methods: Using a dataset including 8,682 polysomnographs, we develop deep neural networks to stage sleep from ECG and respiratory signals. Five…
▽ More
Study Objective: Sleep is reflected not only in the electroencephalogram but also in heart rhythms and breathing patterns. Therefore, we hypothesize that it is possible to accurately stage sleep based on the electrocardiogram (ECG) and respiratory signals. Methods: Using a dataset including 8,682 polysomnographs, we develop deep neural networks to stage sleep from ECG and respiratory signals. Five deep neural networks consisting of convolutional networks and long short-term memory networks are trained to stage sleep using heart and breathing, including the timing of R peaks from ECG, abdominal and chest respiratory effort, and the combinations of these signals. Results: ECG in combination with the abdominal respiratory effort achieve the best performance for staging all five sleep stages with a Cohen's kappa of 0.600 (95% confidence interval 0.599 -- 0.602); and 0.762 (0.760 -- 0.763) for discriminating awake vs. rapid eye movement vs. non-rapid eye movement sleep. The performance is better for young participants and for those with a low apnea-hypopnea index, while it is robust for commonly used outpatient medications. Conclusions: Our results validate that ECG and respiratory effort provide substantial information about sleep stages in a large population. It opens new possibilities in sleep research and applications where electroencephalography is not readily available or may be infeasible, such as in critically ill patients.
△ Less
Submitted 15 September, 2019; v1 submitted 29 August, 2019;
originally announced August 2019.