IDeF-X HD: a CMOS ASIC for the readout of Cd(Zn)Te Detectors for space-borne applications
Authors:
Olivier Gevin,
Francis Lugiez,
Alicja Michalowska,
Aline Meuris,
Olivier Limousin,
Eric Delagnes,
Olivier Lemaire,
Frédéric Pinsard
Abstract:
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to t…
▽ More
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to the in-channel adjustable gain stage. When no detector is connected to the chip and without input current, a 33 electrons rms ENC level is achieved after sha** with 10.7 micro seconds peak time. Spectroscopy measurements have been performed with CdTe Schottky detectors. We measured an energy resolution of 4.2 keV FWHM at 667 keV (137-Cs) on a mono-pixel configuration. Meanwhile, we also measured 562 eV and 666 eV FWHM at 14 keV and 60 keV respectively (241-Am) with a 256 small pixel array and a low detection threshold of 1.2 keV. Since IDeF-X HD is intended for space-borne applications in astrophysics, we evaluated its radiation tolerance and its sensitivity to single event effects. We demonstrated that the ASIC remained fully functional without significant degradation of its performances after 200 krad and that no single event latch-up was detected putting the Linear Energy Transfer threshold above 110 MeV/(mg/cm2). Good noise performance and radiation tolerance make the chip well suited for X-rays energy discrimination and high-energy resolution. The chip is space qualified and flies on board the Solar Orbiter ESA mission launched in 2020.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.
-
Improvement of xenon purification system using a combination of a pulse tube refrigerator and a coaxial heat exchanger
Authors:
Wan-Ting Chen,
D. Chbib,
J. -P. Cussonneau,
J. Donnard,
S. Duval,
O. Lemaire,
M. Le Calloch,
P. Le Ray,
A. -F. Mohamad-Hadi,
E. Morteau,
T. Oger,
L. Scotto-Lavina,
J. -S. Stutzmann,
D. Thers,
P. Briend,
T. Haruyama,
S. Mihara,
T. Tauchi
Abstract:
We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in…
▽ More
We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in a highpressurized large-scale xenon storage with much less thermal losses.
△ Less
Submitted 17 May, 2012;
originally announced May 2012.
-
Hybrid Multi Micropattern Gaseous Photomultiplier for detection of liquid-xenon scintillation
Authors:
Samuel Duval,
Lior Arazi,
Amos Breskin,
Ranny Budnik,
Wan-Ting Chen,
Hervé Carduner,
A. E. C. Coimbra,
Marco Cortesi,
Roy Kaner,
Jean-Pierre Cussonneau,
Jérôme Donnard,
Jacob Lamblin,
Olivier Lemaire,
Patrick Le Ray,
J. A. M. Lopes,
Abdul-Fattah Mohamad Hadi,
Eric Morteau,
Tugdual Oger,
J. M. F. dos Santos,
Luca Scotto Lavina,
Jean-Sébastien Stutzmann,
Dominique Thers
Abstract:
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PI…
▽ More
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PIM) and a MICROMesh GAseous Structure (MICROMEGAS),operating in Ne/CF4 (90:10). Gain values close to 10^7 were recorded in this mixture, with 5.9keV x-rays at 1100 mbar, both at room temperature and at that of liquid xenon (T = 171K). The results are discussed in term of scintillation detection. While the present multiplier was investigated without photocathode, complementary results of photoextraction from CsI UV photocathodes are presented in Ne/CH4 (95:5) and CH4 in cryogenic conditions.
△ Less
Submitted 27 October, 2011;
originally announced October 2011.
-
A liquid xenon TPC for a medical imaging Compton telescope
Authors:
T. Oger,
W-T. Chen,
J-P. Cussonneau,
J. Donnard,
S. Duval,
J. Lamblin,
O. Lemaire,
A. F. Mohamad Hadi,
P. Le Ray,
E. Morteau,
L. Scotto Lavina,
J-S. Stutzmann,
D. Thers
Abstract:
A new technique for medical imaging, "3γ imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order to demonstrate the feasibility of this technique. With an ultra-low-noise front-end electronics, the energy deposit and resolution of 511 keV γ-ray as a function of drift electric field (E) is measured with high precisi…
▽ More
A new technique for medical imaging, "3γ imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order to demonstrate the feasibility of this technique. With an ultra-low-noise front-end electronics, the energy deposit and resolution of 511 keV γ-ray as a function of drift electric field (E) is measured with high precision. 500 μm of z resolution is estimated by measuring the charge carriers drift velocity and time resolution.
△ Less
Submitted 5 December, 2011; v1 submitted 16 September, 2011;
originally announced September 2011.
-
Measurement of the transverse diffusion coefficient of charge in liquid xenon
Authors:
W. -T. Chen,
H. Carduner,
J. -P. Cussonneau,
J. Donnard,
S. Duval,
A. -F. Mohamad-Hadi,
J. Lamblin,
O. Lemaire,
P. Le Ray,
E. Morteau,
T. Oger,
L. Scotto-Lavina,
J. -S. Stutzmann,
D. Thers
Abstract:
Liquid xenon (LXe) is a very attractive material as a detection medium for ionization detectors due to its high density, high atomic number, and low energy required to produce electron-ion pairs. Therefore it has been used in several applications, like γ detection or direct detection of dark matter. Now Subatech is working on the R & D of LXe Compton telescope for 3γ medical imaging, which can mak…
▽ More
Liquid xenon (LXe) is a very attractive material as a detection medium for ionization detectors due to its high density, high atomic number, and low energy required to produce electron-ion pairs. Therefore it has been used in several applications, like γ detection or direct detection of dark matter. Now Subatech is working on the R & D of LXe Compton telescope for 3γ medical imaging, which can make precise tridimensional localization of a (β+, γ) radioisotope emitter. The diffusion of charge carriers will directly affect the spatial resolution of LXe ionization signal. We will report how we measure the transverse diffusion coefficient for different electric field (0.5 ~ 1.2 kV/cm) by observing the spray of charge carriers on drift length varying until 12cm. With very-low-noise front-end electronics and complete Monte-Carlo simulation of the experiment, the values of transverse diffusion coefficient are measured precisely.
△ Less
Submitted 15 September, 2011;
originally announced September 2011.