-
Eikonal phase retrieval: Unleashing the fourth generation sources potential for enhanced propagation based tomography on biological samples
Authors:
Alessandro Mirone,
Joseph Brunet,
Leandre Admans,
Renaud Boistel,
Morgane Sowinski,
Camille Berruyer,
Henri Payno,
Elodie Boller,
Pierre Paleo,
Claire L. Walsh,
Peter D. Lee,
Paul Tafforeau
Abstract:
The evolution of synchrotrons towards higher brilliance beams has increased the possible sample-to-detector propagation distances for which the source confusion circle does not lead to geometrical blurring. This makes it possible to push near-field propagation driven phase contrast enhancement to the limit, revealing low contrast features which would otherwise remain hidden under an excessive nois…
▽ More
The evolution of synchrotrons towards higher brilliance beams has increased the possible sample-to-detector propagation distances for which the source confusion circle does not lead to geometrical blurring. This makes it possible to push near-field propagation driven phase contrast enhancement to the limit, revealing low contrast features which would otherwise remain hidden under an excessive noise. Until today this possibility was hindered, in many objects of scientific interest, by the simultaneous presence of strong phase gradient regions and low contrast features. The strong gradients, when enhanced with the now possible long propagation distances, induce such strong phase effects that the linearisation assumptions of current state-of-the-art single-distance phase retrieval filters are broken, and the resulting image quality is jeopardized. Here, we introduce a new iterative phase-retrieval algorithm and compare it with the Paganin phase-retrieval algorithm, in both the monochromatic and polychromatic cases, obtaining superior image quality. In the polychromatic case the comparison was done with an extrapolated Paganin algorithm obtained by reintroducing, into our phase retrieval algorithm, the linearization approximations underlying the Paganin forward model. Our work provides an innovative algorithm which efficiently performs the phase retrieval task over the entire near-field range, producing images of exceptional quality for mixed attenuation objects.
△ Less
Submitted 18 June, 2024; v1 submitted 22 November, 2023;
originally announced November 2023.
-
Deep Learning for Vascular Segmentation and Applications in Phase Contrast Tomography Imaging
Authors:
Ekin Yagis,
Shahab Aslani,
Yashvardhan Jain,
Yang Zhou,
Shahrokh Rahmani,
Joseph Brunet,
Alexandre Bellier,
Christopher Werlein,
Maximilian Ackermann,
Danny Jonigk,
Paul Tafforeau,
Peter D Lee,
Claire Walsh
Abstract:
Automated blood vessel segmentation is vital for biomedical imaging, as vessel changes indicate many pathologies. Still, precise segmentation is difficult due to the complexity of vascular structures, anatomical variations across patients, the scarcity of annotated public datasets, and the quality of images. We present a thorough literature review, highlighting the state of machine learning techni…
▽ More
Automated blood vessel segmentation is vital for biomedical imaging, as vessel changes indicate many pathologies. Still, precise segmentation is difficult due to the complexity of vascular structures, anatomical variations across patients, the scarcity of annotated public datasets, and the quality of images. We present a thorough literature review, highlighting the state of machine learning techniques across diverse organs. Our goal is to provide a foundation on the topic and identify a robust baseline model for application to vascular segmentation in a new imaging modality, Hierarchical Phase Contrast Tomography (HiP CT). Introduced in 2020 at the European Synchrotron Radiation Facility, HiP CT enables 3D imaging of complete organs at an unprecedented resolution of ca. 20mm per voxel, with the capability for localized zooms in selected regions down to 1mm per voxel without sectioning. We have created a training dataset with double annotator validated vascular data from three kidneys imaged with HiP CT in the context of the Human Organ Atlas Project. Finally, utilising the nnU Net model, we conduct experiments to assess the models performance on both familiar and unseen samples, employing vessel specific metrics. Our results show that while segmentations yielded reasonably high scores such as clDice values ranging from 0.82 to 0.88, certain errors persisted. Large vessels that collapsed due to the lack of hydrostatic pressure (HiP CT is an ex vivo technique) were segmented poorly. Moreover, decreased connectivity in finer vessels and higher segmentation errors at vessel boundaries were observed. Such errors obstruct the understanding of the structures by interrupting vascular tree connectivity. Through our review and outputs, we aim to set a benchmark for subsequent model evaluations using various modalities, especially with the HiP CT imaging database.
△ Less
Submitted 22 November, 2023;
originally announced November 2023.
-
High Resolution 3D Strain and Orientation Map** within a Grain of a Directed Energy Deposition Laser Additively Manufactured Superalloy
Authors:
Y. Chen,
Y. T. Tang,
D. M. Collins,
S. J. Clark,
W. Ludwig,
R. Rodriguez-Lamas,
C. Detlefs,
R. C. Reed,
P. D. Lee,
P. J. Withers,
C. Yildirim
Abstract:
The industrialization of Laser Additive Manufacturing (LAM) is challenged by the undesirable microstructures and high residual stresses originating from the fast and complex solidification process. Non-destructive assessment of the mechanical performance controlling deformation patterning is therefore critical. Here, we use Dark Field X-ray Microscopy (DFXM) to non-destructively map the 3D intragr…
▽ More
The industrialization of Laser Additive Manufacturing (LAM) is challenged by the undesirable microstructures and high residual stresses originating from the fast and complex solidification process. Non-destructive assessment of the mechanical performance controlling deformation patterning is therefore critical. Here, we use Dark Field X-ray Microscopy (DFXM) to non-destructively map the 3D intragranular orientation and strain variations throughout a surface breaking grain within a directed energy deposition nickel superalloy. DFXM results reveal a highly heterogenous 3D microstructure in terms of the local orientation and lattice strain. The grain comprises $\approx$ 5$μ$m-sized cells with alternating strain states, as high as 5 $\times 10^{-3}$, and orientation differences <0.5° . The DFXM results are compared to Electron Backscatter Diffraction measurements of the same grain from its cut-off surface. We discuss the microstructure developments during LAM, rationalising the development of the deformation patterning from the extreme thermal gradients during processing and the susceptibility for solute segregation.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Correlative Synchrotron X-ray Imaging and Diffraction of Directed Energy Deposition Additive Manufacturing
Authors:
Yunhui Chen,
Samuel J. Clark,
David M. Collins,
Sebastian Marussi,
Simon A. Hunt,
Danielle M. Fenech,
Thomas Connolley,
Robert C. Atwood,
Oxana V. Magdysyuk,
Gavin J. Baxter,
Martyn A. Jones,
Chu Lun Alex Leung,
Peter D. Lee
Abstract:
The governing mechanistic behaviour of Directed Energy Deposition Additive Manufacturing (DED-AM) is revealed by a combined in situ and operando synchrotron X-ray imaging and diffraction study of a nickel-base superalloy, IN718. Using a unique process replicator, real-space phase-contrast imaging enables quantification of the melt-pool boundary and flow dynamics during solidification. This imaging…
▽ More
The governing mechanistic behaviour of Directed Energy Deposition Additive Manufacturing (DED-AM) is revealed by a combined in situ and operando synchrotron X-ray imaging and diffraction study of a nickel-base superalloy, IN718. Using a unique process replicator, real-space phase-contrast imaging enables quantification of the melt-pool boundary and flow dynamics during solidification. This imaging knowledge informed precise diffraction measurements of temporally resolved microstructural phases during transformation and stress development with a spatial resolution of 100 $μ$m. The diffraction quantified thermal gradient enabled a dendritic solidification microstructure to be predicted and coupled to the stress orientation and magnitude. The fast cooling rate entirely suppressed the formation of secondary phases or recrystallisation in the solid-state. Upon solidification, the stresses rapidly increase to the yield strength during cooling. This insight, combined with IN718 $'$s large solidification range suggests that the accumulated plasticity exhausts the alloy$'$s ductility, causing liquation cracking. This study has revealed additional fundamental mechanisms governing the formation of highly non-equilibrium microstructures during DED-AM.
△ Less
Submitted 16 September, 2020;
originally announced September 2020.
-
In situ and Operando X-ray Imaging of Directed Energy Deposition Additive Manufacturing
Authors:
Yunhui Chen,
Samuel J. Clark,
Lorna Sinclair,
Chu Lun Alex Leung,
Sebastian Marussi,
Thomas Connolley,
Oxana V. Magdysyuk,
Robert C. Atwood,
Gavin J. Baxter,
Martyn A. Jones,
David G. McCartney,
Iain Todd,
Peter D. Lee
Abstract:
The mechanical performance of Directed Energy Deposition Additive Manufactured (DED-AM) components can be highly material dependent. Through in situ and operando synchrotron X-ray imaging we capture the underlying phenomena controlling build quality of stainless steel (SS316) and titanium alloy (Ti6242 or Ti-6Al-2Sn-4Zr-2Mo). We reveal three mechanisms influencing the build efficiency of titanium…
▽ More
The mechanical performance of Directed Energy Deposition Additive Manufactured (DED-AM) components can be highly material dependent. Through in situ and operando synchrotron X-ray imaging we capture the underlying phenomena controlling build quality of stainless steel (SS316) and titanium alloy (Ti6242 or Ti-6Al-2Sn-4Zr-2Mo). We reveal three mechanisms influencing the build efficiency of titanium alloys compared to stainless steel: blown powder sintering; reduced melt-pool wetting due to the sinter; and pore pushing in the melt-pool. The former two directly increase lack of fusion porosity, while the later causes end of track porosity. Each phenomenon influences the melt-pool characteristics, wetting of the substrate and hence build efficacy and undesirable microstructural feature formation. We demonstrate that porosity is related to powder characteristics, pool flow, and solidification front morphology. Our results clarify DED-AM process dynamics, illustrating why each alloy builds differently, facilitating the wider application of additive manufacturing to new materials.
△ Less
Submitted 16 June, 2020;
originally announced June 2020.
-
Direct high-order edge-preserving regularization for tomographic image reconstruction
Authors:
Daniil Kazantsev,
Evgueni Ovtchinnikov,
William R. B. Lionheart,
Philip J. Withers,
Peter D. Lee
Abstract:
In this paper we present a new two-level iterative algorithm for tomographic image reconstruction. The algorithm uses a regularization technique, which we call edge-preserving Laplacian, that preserves sharp edges between objects while dam** spurious oscillations in the areas where the reconstructed image is smooth. Our numerical simulations demonstrate that the proposed method outperforms total…
▽ More
In this paper we present a new two-level iterative algorithm for tomographic image reconstruction. The algorithm uses a regularization technique, which we call edge-preserving Laplacian, that preserves sharp edges between objects while dam** spurious oscillations in the areas where the reconstructed image is smooth. Our numerical simulations demonstrate that the proposed method outperforms total variation (TV) regularization and it is competitive with the combined TV-L2 penalty. Obtained reconstructed images show increased signal-to-noise ratio and visually appealing structural features. Computer implementation and parameter control of the proposed technique is straightforward, which increases the feasibility of it across many tomographic applications. In this paper, we applied our method to the under-sampled computed tomography (CT) projection data and also considered a case of reconstruction in emission tomography The MATLAB code is provided to support obtained results.
△ Less
Submitted 15 September, 2015;
originally announced September 2015.
-
Solid-liquid interface free energy through metadynamics simulations
Authors:
Stefano Angioletti-Uberti,
Michele Ceriotti,
Mike W. Finnis,
Peter D. Lee
Abstract:
The solid-liquid interface free energy γsl is a key parameter controlling nucleation and growth during solidification and other phenomena. There are intrinsic difficulties in obtaining accurate experimental values, and the previous approaches to compute γsl with atomistic simulations are computationally demanding. We propose a new approach, which is to obtain γsl from a free energy map of the phas…
▽ More
The solid-liquid interface free energy γsl is a key parameter controlling nucleation and growth during solidification and other phenomena. There are intrinsic difficulties in obtaining accurate experimental values, and the previous approaches to compute γsl with atomistic simulations are computationally demanding. We propose a new approach, which is to obtain γsl from a free energy map of the phase transition reconstructed by metadynamics. We apply this to the benchmark case of a Lennard-Jones potential and the results confirm the most reliable data obtained previously. We demonstrate several advantages of our new approach: it is simple to implement, robust and free of hysteresis problems, it allows a rigorous and unbiased estimate of the statistical uncertainty and it returns a good estimate of of the thermodynamic limit with system sizes of a just a few hundred atoms. It is therefore attractive for using with more realistic and specific models of interatomic forces.
△ Less
Submitted 19 May, 2010; v1 submitted 13 November, 2009;
originally announced November 2009.