Skip to main content

Showing 1–3 of 3 results for author: Leduc, A

.
  1. arXiv:2308.07465  [pdf

    q-bio.GN q-bio.BM q-bio.TO

    Modeling and interpretation of single-cell proteogenomic data

    Authors: Andrew Leduc, Hannah Harens, Nikolai Slavov

    Abstract: Biological functions stem from coordinated interactions among proteins, nucleic acids and small molecules. Mass spectrometry technologies for reliable, high throughput single-cell proteomics will add a new modality to genomics and enable data-driven modeling of the molecular mechanisms coordinating proteins and nucleic acids at single-cell resolution. This promising potential requires estimating t… ▽ More

    Submitted 4 November, 2023; v1 submitted 14 August, 2023; originally announced August 2023.

  2. Initial recommendations for performing, benchmarking, and reporting single-cell proteomics experiments

    Authors: Laurent Gatto, Ruedi Aebersold, Juergen Cox, Vadim Demichev, Jason Derks, Edward Emmott, Alexander M. Franks, Alexander R. Ivanov, Ryan T. Kelly, Luke Khoury, Andrew Leduc, Michael J. MacCoss, Peter Nemes, David H. Perlman, Aleksandra A. Petelski, Christopher M. Rose, Erwin M. Schoof, Jennifer Van Eyk, Christophe Vanderaa, John R. Yates III, Nikolai Slavov

    Abstract: Analyzing proteins from single cells by tandem mass spectrometry (MS) has become technically feasible. While such analysis has the potential to accurately quantify thousands of proteins across thousands of single cells, the accuracy and reproducibility of the results may be undermined by numerous factors affecting experimental design, sample preparation, data acquisition, and data analysis. Broadl… ▽ More

    Submitted 12 September, 2022; v1 submitted 19 July, 2022; originally announced July 2022.

    Comments: Supporting website: https://single-cell.net/guidelines

    Journal ref: Nature Methods, 20, 375--386 (2023)

  3. Angular distribution measurement of atoms evaporated from a resistive oven applied to ion beam production

    Authors: A. Leduc, T. Thuillier, L. Maunoury, O. Bajeat

    Abstract: A low temperature oven has been developed to produce calcium beam with Electron Cyclotron Resonance Ion Source (ECRIS). The atom flux from the oven has been studied experimentally as a function of the temperature and the angle of emission by means of a quartz microbalance. The absolute flux measurement permitted to derive Antoine's coefficient for the calcium sample used : A=8.98$\pm$ 0.07 and B=7… ▽ More

    Submitted 4 February, 2021; v1 submitted 8 January, 2021; originally announced January 2021.

    Comments: 16 pages, 11 figures