-
Modeling and interpretation of single-cell proteogenomic data
Authors:
Andrew Leduc,
Hannah Harens,
Nikolai Slavov
Abstract:
Biological functions stem from coordinated interactions among proteins, nucleic acids and small molecules. Mass spectrometry technologies for reliable, high throughput single-cell proteomics will add a new modality to genomics and enable data-driven modeling of the molecular mechanisms coordinating proteins and nucleic acids at single-cell resolution. This promising potential requires estimating t…
▽ More
Biological functions stem from coordinated interactions among proteins, nucleic acids and small molecules. Mass spectrometry technologies for reliable, high throughput single-cell proteomics will add a new modality to genomics and enable data-driven modeling of the molecular mechanisms coordinating proteins and nucleic acids at single-cell resolution. This promising potential requires estimating the reliability of measurements and computational analysis so that models can distinguish biological regulation from technical artifacts. We highlight different measurement modes that can support single-cell proteogenomic analysis and how to estimate their reliability. We then discuss approaches for develo** both abstract and mechanistic models that aim to biologically interpret the measured differences across modalities, including specific applications to directed stem cell differentiation and to inferring protein interactions in cancer cells from the buffing of DNA copy-number variations. Single-cell proteogenomic data will support mechanistic models of direct molecular interactions that will provide generalizable and predictive representations of biological systems.
△ Less
Submitted 4 November, 2023; v1 submitted 14 August, 2023;
originally announced August 2023.
-
Initial recommendations for performing, benchmarking, and reporting single-cell proteomics experiments
Authors:
Laurent Gatto,
Ruedi Aebersold,
Juergen Cox,
Vadim Demichev,
Jason Derks,
Edward Emmott,
Alexander M. Franks,
Alexander R. Ivanov,
Ryan T. Kelly,
Luke Khoury,
Andrew Leduc,
Michael J. MacCoss,
Peter Nemes,
David H. Perlman,
Aleksandra A. Petelski,
Christopher M. Rose,
Erwin M. Schoof,
Jennifer Van Eyk,
Christophe Vanderaa,
John R. Yates III,
Nikolai Slavov
Abstract:
Analyzing proteins from single cells by tandem mass spectrometry (MS) has become technically feasible. While such analysis has the potential to accurately quantify thousands of proteins across thousands of single cells, the accuracy and reproducibility of the results may be undermined by numerous factors affecting experimental design, sample preparation, data acquisition, and data analysis. Broadl…
▽ More
Analyzing proteins from single cells by tandem mass spectrometry (MS) has become technically feasible. While such analysis has the potential to accurately quantify thousands of proteins across thousands of single cells, the accuracy and reproducibility of the results may be undermined by numerous factors affecting experimental design, sample preparation, data acquisition, and data analysis. Broadly accepted community guidelines and standardized metrics will enhance rigor, data quality, and alignment between laboratories. Here we propose best practices, quality controls, and data reporting recommendations to assist in the broad adoption of reliable quantitative workflows for single-cell proteomics.
△ Less
Submitted 12 September, 2022; v1 submitted 19 July, 2022;
originally announced July 2022.
-
Angular distribution measurement of atoms evaporated from a resistive oven applied to ion beam production
Authors:
A. Leduc,
T. Thuillier,
L. Maunoury,
O. Bajeat
Abstract:
A low temperature oven has been developed to produce calcium beam with Electron Cyclotron Resonance Ion Source (ECRIS). The atom flux from the oven has been studied experimentally as a function of the temperature and the angle of emission by means of a quartz microbalance. The absolute flux measurement permitted to derive Antoine's coefficient for the calcium sample used : A=8.98$\pm$ 0.07 and B=7…
▽ More
A low temperature oven has been developed to produce calcium beam with Electron Cyclotron Resonance Ion Source (ECRIS). The atom flux from the oven has been studied experimentally as a function of the temperature and the angle of emission by means of a quartz microbalance. The absolute flux measurement permitted to derive Antoine's coefficient for the calcium sample used : A=8.98$\pm$ 0.07 and B=7787$\pm$ 110 in standard unit. The angular FWHM of the atom flux distribution is found to be 53.7°$\pm$7.3 at 848K, temperature at which the gas behaviour is non collisional. The atom flux hysteresis observed experimentally in several laboratories is explained as follows: at first calcium heating, the evaporation comes from the sample only, resulting in a small evaporation rate. once a full calcium layer has formed on the crucible refractory wall, the calcium evaporation surface includes the crucible's enhancing dramatically the evaporation rate for a given temperature. A Monte-Carlo code, developed to reproduce and investigate the oven behaviour as a function of temperature is presented. A discussion on the gas regime in the oven is proposed as a function of its temperature. A fair agreement between experiment and simulation is found.
△ Less
Submitted 4 February, 2021; v1 submitted 8 January, 2021;
originally announced January 2021.