-
Deep Contrast and Companion Detection Using the EvWaCo Testbed Equipped with an Achromatic Focal Plane Mask and an Adjustable Inner Working Angle
Authors:
M. A. Alagao,
A. Kawinkij,
C. Buisset,
A. Prasit,
T. Lépine,
Y. Rabbia,
A. Berdeu,
É. Thiébaut,
M. Langlois,
M. Tallon,
S. Awiphan,
E. Semenko,
P. Rittipruk,
D. Mkrtichian,
A. Leckngam,
G. Thuammasorn,
P. Kaewsamoeta,
A. Inpan,
T. Kuha,
A. Laoyang,
W. Somboonchai,
S. Kanthum,
S. Poshyachinda,
B. Soonthornthum
Abstract:
The evanescent wave coronagraph uses the principle of frustrated total internal reflection (FTIR) to suppress the light coming from the star and study its close environment. Its focal plane mask is composed of a lens and a prism placed in contact with each other to produce the coronagraphic effect. In this paper, we present the experimental results obtained using an upgraded focal plane mask of th…
▽ More
The evanescent wave coronagraph uses the principle of frustrated total internal reflection (FTIR) to suppress the light coming from the star and study its close environment. Its focal plane mask is composed of a lens and a prism placed in contact with each other to produce the coronagraphic effect. In this paper, we present the experimental results obtained using an upgraded focal plane mask of the Evanescent Wave Coronagraph (EvWaCo). These experimental results are also compared to the theoretical performance of the coronagraph obtained through simulations. Experimentally, we reach a raw contrast equal to a few $10^{-4}$ at a distance equal to 3 $λ/D$ over the full I-band ($λ_c =$ $800$ $nm$, $Δλ/λ \approx 20\%$) and equal to 4 $λ/D$ over the full R-band ($λ_c =$ $650$ $nm$, $Δλ/λ \approx 23\%$) in unpolarized light. However, our simulations show a raw contrast close to $10^{-4}$ over the full I-band and R-band at the same distance, thus, confirming the theoretical achromatic advantage of the coronagraph. We also verify the stability of the mask through a series of contrast measurements over a period of 8 months. Furthermore, we measure the sensitivity of the coronagraph to the lateral and longitudinal misalignment of the focal plane mask, and to the lateral misalignment of the Lyot stop.
△ Less
Submitted 19 March, 2021; v1 submitted 18 March, 2021;
originally announced March 2021.
-
Cherenkov Telescope Array Contributions to the 35th International Cosmic Ray Conference (ICRC2017)
Authors:
F. Acero,
B. S. Acharya,
V. Acín Portella,
C. Adams,
I. Agudo,
F. Aharonian,
I. Al Samarai,
A. Alberdi,
M. Alcubierre,
R. Alfaro,
J. Alfaro,
C. Alispach,
R. Aloisio,
R. Alves Batista,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
M. Anduze,
E. O. Angüner,
E. Antolini,
L. A. Antonelli,
V. Antonuccio
, et al. (1117 additional authors not shown)
Abstract:
List of contributions from the Cherenkov Telescope Array Consortium presented at the 35th International Cosmic Ray Conference, July 12-20 2017, Busan, Korea.
List of contributions from the Cherenkov Telescope Array Consortium presented at the 35th International Cosmic Ray Conference, July 12-20 2017, Busan, Korea.
△ Less
Submitted 24 October, 2017; v1 submitted 11 September, 2017;
originally announced September 2017.
-
The binary millisecond pulsar PSR J1023+0038 during its accretion state - I. Optical variability
Authors:
T. Shahbaz,
M. Linares,
S. P. Nevado,
P. Rodríguez-Gil,
J. Casares,
V. S. Dhillon,
T. R. Marsh,
S. Littlefair,
A. Leckngam,
S. Poshyachinda
Abstract:
We present time-resolved optical photometry of the binary millisecond `redback' pulsar PSR J1023+0038 (=AY Sex) during its low-mass X-ray binary phase. The light curves taken between 2014 January and April show an underlying sinusoidal modulation due to the irradiated secondary star and accretion disc. We also observe superimposed rapid flaring on time-scales as short as ~20 s with amplitudes of ~…
▽ More
We present time-resolved optical photometry of the binary millisecond `redback' pulsar PSR J1023+0038 (=AY Sex) during its low-mass X-ray binary phase. The light curves taken between 2014 January and April show an underlying sinusoidal modulation due to the irradiated secondary star and accretion disc. We also observe superimposed rapid flaring on time-scales as short as ~20 s with amplitudes of ~0.1-0.5 mag and additional large flare events on time-scales of ~5-60 min with amplitudes ~0.5-1.0 mag. The power density spectrum of the optical flare light curves is dominated by a red-noise component, typical of aperiodic activity in X-ray binaries. Simultaneous X-ray and UV observations by the Swift satellite reveal strong correlations that are consistent with X-ray reprocessing of the UV light, most likely in the outer regions of the accretion disc. On some nights we also observe sharp-edged, rectangular, flat-bottomed dips randomly distributed in orbital phase, with a median duration of ~250 s and a median ingress/egress time of ~20 s. These rectangular dips are similar to the mode-switching behaviour between disc `active' and `passive' luminosity states, observed in the X-ray light curves of other redback millisecond pulsars. This is the first time that the optical analogue of the X-ray mode-switching has been observed. The properties of the passive and active state light curves can be explained in terms of clumpy accretion from a trapped inner accretion disc near the corotation radius, resulting in rectangular, flat-bottomed optical and X-ray light curves.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
Testing the planetary models of HU Aquarii
Authors:
M. Bours,
T. Marsh,
E. Breedt,
C. Copperwheat,
V. Dhillon,
A. Leckngam,
S. Littlefair,
S. Parsons,
A. Prasit
Abstract:
We present new eclipse observations of the polar (i.e. semi-detached magnetic white dwarf + M-dwarf binary) HU Aqr, and mid-egress times for each eclipse, which continue to be observed increasingly early. Recent eclipses occurred more than 70 seconds earlier than the prediction from the latest model that invoked a single circumbinary planet to explain the observed orbital period variations, thereb…
▽ More
We present new eclipse observations of the polar (i.e. semi-detached magnetic white dwarf + M-dwarf binary) HU Aqr, and mid-egress times for each eclipse, which continue to be observed increasingly early. Recent eclipses occurred more than 70 seconds earlier than the prediction from the latest model that invoked a single circumbinary planet to explain the observed orbital period variations, thereby conclusively proving this model to be incorrect. Using ULTRACAM data, we show that mid-egress times determined for simultaneous data taken at different wavelengths agree with each other. The large variations in the observed eclipse times cannot be explained by planetary models containing up to three planets, because of poor fits to the data as well as orbital instability on short time scales. The peak-to-peak amplitude of the O-C diagram of almost 140 seconds is also too great to be caused by Applegate's mechanism, movement of the accretion spot on the surface of the white dwarf, or by asynchronous rotation of the white dwarf. What does cause the observed eclipse time variations remains a mystery.
△ Less
Submitted 11 September, 2014;
originally announced September 2014.
-
ULTRASPEC: a high-speed imaging photometer on the 2.4-m Thai National Telescope
Authors:
V. S. Dhillon,
T. R. Marsh,
D. C. Atkinson,
N. Bezawada,
M. C. P. Bours,
C. M. Copperwheat,
T. Gamble,
L. K. Hardy,
R. D. H. Hickman,
P. Irawati,
D. J. Ives,
P. Kerry,
A. Leckngam,
S. P. Littlefair,
S. A. McLay,
K. O'Brien,
P. T. Peacocke,
S. Poshyachinda,
A. Richichi,
B. Soonthornthum,
A. Vick
Abstract:
ULTRASPEC is a high-speed imaging photometer mounted permanently at one of the Nasmyth focii of the 2.4-m Thai National Telescope (TNT) on Doi Inthanon, Thailand's highest mountain. ULTRASPEC employs a 1024x1024 pixel frame-transfer, electron-multiplying CCD (EMCCD) in conjunction with re-imaging optics to image a field of 7.7'x7.7' at (windowed) frame rates of up to ~200 Hz. The EMCCD has two out…
▽ More
ULTRASPEC is a high-speed imaging photometer mounted permanently at one of the Nasmyth focii of the 2.4-m Thai National Telescope (TNT) on Doi Inthanon, Thailand's highest mountain. ULTRASPEC employs a 1024x1024 pixel frame-transfer, electron-multiplying CCD (EMCCD) in conjunction with re-imaging optics to image a field of 7.7'x7.7' at (windowed) frame rates of up to ~200 Hz. The EMCCD has two outputs - a normal output that provides a readout noise of 2.3 e- and an avalanche output that can provide essentially zero readout noise. A six-position filter wheel enables narrow-band and broad-band imaging over the wavelength range 330-1000 nm. The instrument saw first light on the TNT in November 2013 and will be used to study rapid variability in the Universe. In this paper we describe the scientific motivation behind ULTRASPEC, present an outline of its design and report on its measured performance on the TNT.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.