-
Measurement of the Beam-Normal Single-Spin Asymmetry for Elastic Electron Scattering from $^{12}$C and $^{27}$Al
Authors:
QWeak Collaboration,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
K. Bartlett,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Birchall,
R. D. Carlini,
M. E. Christy,
J. C. Cornejo,
S. Covrig Dusa,
M. M. Dalton,
C. A. Davis,
W. Deconinck,
J. F. Dowd,
J. A. Dunne,
D. Dutta,
W. S. Duvall,
M. Elassar,
W. R. Falk,
J. M. Finn,
T. Forest,
C. Gal
, et al. (60 additional authors not shown)
Abstract:
We report measurements of the parity-conserving beam-normal single-spin elastic scattering asymmetries $B_n$ on $^{12}$C and $^{27}$Al, obtained with an electron beam polarized transverse to its momentum direction. These measurements add an additional kinematic point to a series of previous measurements of $B_n$ on $^{12}$C and provide a first measurement on $^{27}$Al. The experiment utilized the…
▽ More
We report measurements of the parity-conserving beam-normal single-spin elastic scattering asymmetries $B_n$ on $^{12}$C and $^{27}$Al, obtained with an electron beam polarized transverse to its momentum direction. These measurements add an additional kinematic point to a series of previous measurements of $B_n$ on $^{12}$C and provide a first measurement on $^{27}$Al. The experiment utilized the Qweak apparatus at Jefferson Lab with a beam energy of 1.158 GeV. The average lab scattering angle for both targets was 7.7 degrees, and the average $Q^2$ for both targets was 0.02437 GeV$^2$ (Q=0.1561 GeV). The asymmetries are $B_n$ = -10.68 $\pm$ 0.90 stat) $\pm$ 0.57 (syst) ppm for $^{12}$C and $B_n$ = -12.16 $\pm$ 0.58 (stat) $\pm$ 0.62 (syst) ppm for $^{27}$Al. The results are consistent with theoretical predictions, and are compared to existing data. When scaled by Z/A, the Q-dependence of all the far-forward angle (theta < 10 degrees) data from $^{1}$H to $^{27}$Al can be described by the same slope out to $Q \approx 0.35$ GeV. Larger-angle data from other experiments in the same Q range are consistent with a slope about twice as steep.
△ Less
Submitted 18 June, 2021; v1 submitted 17 March, 2021;
originally announced March 2021.
-
Precision Measurement of the Beam-Normal Single-Spin Asymmetry in Forward-Angle Elastic Electron-Proton Scattering
Authors:
QWeak collaboration,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
K. Bartlett,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Birchall,
R. D. Carlini,
J. C. Cornejo,
S. Covrig Dusa,
M. M. Dalton,
C. A. Davis,
W. Deconinck,
J. F. Dowd,
J. A. Dunne,
D. Dutta,
W. S. Duvall,
M. Elaasar,
W. R. Falk,
J. M. Finn,
T. Forest,
C. Gal
, et al. (70 additional authors not shown)
Abstract:
A beam-normal single-spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable related to the imaginary part of the two-photon exchange process. We report a 2% precision measurement of the beam-normal single-spin asymmetry in elastic electron-proton scattering with a mean scattering angle of theta_lab = 7.9 degrees and a mean energy o…
▽ More
A beam-normal single-spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable related to the imaginary part of the two-photon exchange process. We report a 2% precision measurement of the beam-normal single-spin asymmetry in elastic electron-proton scattering with a mean scattering angle of theta_lab = 7.9 degrees and a mean energy of 1.149 GeV. The asymmetry result is B_n = -5.194 +- 0.067 (stat) +- 0.082 (syst) ppm. This is the most precise measurement of this quantity available to date and therefore provides a stringent test of two-photon exchange models at far-forward scattering angles (theta_lab -> 0) where they should be most reliable.
△ Less
Submitted 29 August, 2020; v1 submitted 22 June, 2020;
originally announced June 2020.
-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
The Q_weak Experimental Apparatus
Authors:
Qweak Collaboration,
T. Allison,
M. Anderson,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
T. D. Averett,
R. Averill,
J. Balewski,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Bessuille,
J. Birchall,
E. Bonnell,
J. Bowman,
P. Brindza,
D. B. Brown,
R. D. Carlini,
G. D. Cates,
B. Cavness,
G. Clark,
J. C. Cornejo,
S. Covrig Dusa
, et al. (104 additional authors not shown)
Abstract:
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry…
▽ More
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.
△ Less
Submitted 6 January, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.
-
A measurement of the energy and timing resolution of GlueX Forward Calorimeter using an electron beam
Authors:
Kei Moriya,
John P. Leckey,
Matthew R. Shepherd,
Kevin Bauer,
Daniel Bennett,
John Frye,
Juan Gonzalez,
Scott J. Henderson,
David Lawrence,
Ryan Mitchell,
Elton S. Smith,
Paul Smith,
Alexander Somov,
Hovanes Egiyan
Abstract:
The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are near the lower-limits of the design sensitivity, the fractional energy resolution was measured to range from 20% to 14%, which meets the design goals. The use…
▽ More
The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are near the lower-limits of the design sensitivity, the fractional energy resolution was measured to range from 20% to 14%, which meets the design goals. The use of custom 250 MHz flash ADCs for readout allowed precise measurements of signal arrival times. The detector achieved timing resolutions of 0.38 ns for a single 100 mV pulse, which will allow timing discrimination of photon beam bunches and out-of-time background during the operation of the GlueX detector.
△ Less
Submitted 17 April, 2013;
originally announced April 2013.
-
The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge
Authors:
R. D. Carlini,
J. M. Finn,
S. Kowalski,
S. A. Page,
D. S. Armstrong,
A. Asaturyan,
T. Averett,
J. Benesch,
J. Birchall,
P. Bosted,
A. Bruell,
C. L. Capuano,
G. Cates,
C. Carrigee,
S. Chattopadhyay,
S. Covrig,
C. A. Davis,
K. Dow,
J. Dunne,
D. Dutta,
R. Ent,
J. Erler,
W. Falk,
H. Fenker,
T. A. Forest
, et al. (61 additional authors not shown)
Abstract:
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep…
▽ More
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep scattering at Q^2=0.03 (GeV/c)^2 employing 180 $μ$A of 85% polarized beam on a 35 cm liquid Hydrogen target will determine the proton's weak charge with approximately 4% combined statistical and systematic errors. The Standard Model makes a firm prediction of $Q_W$, based on the running of the weak mixing angle from the Z0 pole down to low energies, corresponding to a 10 sigma effect in this experiment.
△ Less
Submitted 7 February, 2012; v1 submitted 6 February, 2012;
originally announced February 2012.