Gain factor and parameter settings optimization of the new gamma-ray burst polarimeter POLAR
Authors:
X. F. Zhang,
W. Hajdas,
H. L. Xiao,
X. Wen,
B. B. Wu,
T. W. Bao,
T. Batsch,
T. Bernasconi,
F. Cadoux,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
J. J. He,
M. Kole,
M. N. Kong,
C. Lechanoine-Leluc,
L. Li,
Z. H. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rapin
, et al. (16 additional authors not shown)
Abstract:
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In thi…
▽ More
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In this article we present results on gain optimization togeter with verification data obtained in the course of broad laboratory and environmental tests. In particular we focus on exposures to the $^{137}$Cs radioactive source and determination of the gain dependence on the high voltage for all 1600 detection channels of the polarimeter. Performance of the instrument is described in detail with respect to the dynamic range, energy resolution and temperature dependence. Gain optimization algorithms and response non-uniformity studies are also broadly discussed. Results presented below constitute important parts for development of the POLAR calibration and operation database.
△ Less
Submitted 14 March, 2017; v1 submitted 12 March, 2017;
originally announced March 2017.
-
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB Polarimeter
Authors:
M. Kole,
T. W. Bao,
T. Batsch,
T. Bernasconi,
F. Cadoux,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
W. Hajdas,
J. J. He,
M. N. Kong,
S. W. Kong,
C. Lechanoine-Leluc,
L. Li,
Z. H. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
N. Produit,
D. Rapin,
A. Rutczynska,
D. Rybka,
H. L. Shi
, et al. (19 additional authors not shown)
Abstract:
Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measuremen…
▽ More
Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measurements of the polarization of the emission from gamma-ray burst in the 50-500 keV energy range. This new polarimeter is expected to detect approximately 50 gamma-ray bursts per year while performing high precision polarization measurements on approximately 10 bursts per year. The instrument was launched into lower earth orbit as part of the second Chinese space lab, the Tiangong-2, on September 15th 2016 and has been taking data successfully since being switched on one week after. The instrument uses a segmented scintillator array consisting of 1600 plastic scintillator bars, read out by 25 flat-panel multi-anode photomultipliers, to measure the Compton scattering angles of incoming photons. The small segmentation and relatively large uniform effective area allow the instrument to measure the polarization of a large number of transient events, such as gamma-ray bursts, with an unprecedented precision during its two year life-time. The final flight model underwent detailed calibration prior to launch as well as intensive space qualification tests, a summary of which will be presented in this paper. The instrument design will be discussed first followed by an overview of the on-ground tests, finally the in-orbit behavior as measured during the first weeks of the mission will be presented.
△ Less
Submitted 13 December, 2016;
originally announced December 2016.
-
A method to localize gamma-ray bursts using POLAR
Authors:
E. Suarez-Garcia,
D. Haas,
W. Hajdas,
G. Lamanna,
C. Lechanoine-Leluc,
R. Marcinkowski,
A. Mtchedlishvili,
S. Orsi,
M. Pohl,
N. Produit,
D. Rapin,
D. Rybka,
J. -P. Vialle
Abstract:
The hard X-ray polarimeter POLAR aims to measure the linear polarization of the 50-500 keV photons arriving from the prompt emission of gamma-ray bursts (GRBs). The position in the sky of the detected GRBs is needed to determine their level of polarization. We present here a method by which, despite of the polarimeter incapability of taking images, GRBs can be roughly localized using POLAR alone.…
▽ More
The hard X-ray polarimeter POLAR aims to measure the linear polarization of the 50-500 keV photons arriving from the prompt emission of gamma-ray bursts (GRBs). The position in the sky of the detected GRBs is needed to determine their level of polarization. We present here a method by which, despite of the polarimeter incapability of taking images, GRBs can be roughly localized using POLAR alone. For this purpose scalers are attached to the output of the 25 multi-anode photomultipliers (MAPMs) that collect the light from the POLAR scintillator target. Each scaler measures how many GRB photons produce at least one energy deposition above 50 keV in the corresponding MAPM. Simulations show that the relative outputs of the 25 scalers depend on the GRB position. A database of very strong GRBs simulated at 10201 positions has been produced. When a GRB is detected, its location is calculated searching the minimum of the chi2 obtained in the comparison between the measured scaler pattern and the database. This GRB localization technique brings enough accuracy so that the error transmitted to the 100% modulation factor is kept below 10% for GRBs with fluence Ftot \geq 10^(-5) erg cm^(-2) . The POLAR localization capability will be useful for those cases where no other instruments are simultaneously observing the same field of view.
△ Less
Submitted 16 November, 2010;
originally announced November 2010.