Skip to main content

Showing 1–18 of 18 results for author: Lebreton, L

.
  1. arXiv:1602.01738  [pdf, other

    astro-ph.IM physics.ins-det

    MIMAC low energy electron-recoil discrimination measured with fast neutrons

    Authors: Q. Riffard, D. Santos, O. Guillaudin, G. Bosson, O. Bourrion, J. Bouvier, T. Descombes, J. -F. Muraz, L. Lebreton, D. Maire, P. Colas, I. Giomataris, J. Busto, D. Fouchez, J. Brunner, C. Tao

    Abstract: MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using m… ▽ More

    Submitted 4 July, 2016; v1 submitted 4 February, 2016; originally announced February 2016.

    Comments: 27 pages, 20 figures

  2. arXiv:1504.05865  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    First detection of tracks of radon progeny recoils by MIMAC

    Authors: Q. Riffard, D. Santos, G. Bosson, O. Bourrion, T. Descombes, C. Fourel, O. Guillaudin, J. -F. Muraz, P. Colas, E. Ferrer-Ribas, I. Giomataris, J. Busto, D. Fouchez, C. Tao, L. Lebreton, D. Maire

    Abstract: The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since… ▽ More

    Submitted 20 June, 2017; v1 submitted 22 April, 2015; originally announced April 2015.

    Comments: 11 pages, 12 figures, submitted to PRD

  3. arXiv:1401.1009  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Measurement of the electron drift velocity for directional dark matter detectors

    Authors: F. Mayet, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by sim… ▽ More

    Submitted 6 January, 2014; originally announced January 2014.

    Comments: Proceedings of the 4th international conference on Directional Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japan

    Report number: in2p3-00845411

    Journal ref: J. Phys. Conf. Ser. 469 (2013) 012006

  4. arXiv:1311.0616  [pdf, other

    physics.ins-det astro-ph.CO

    MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection

    Authors: D. Santos, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, J. Lamblin, F. Mayet, J. F. Muraz, J. P. Richer, Q. Riffard, L. Lebreton, D. Maire, J. Busto, J. Brunner, D. Fouchez

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last ye… ▽ More

    Submitted 4 November, 2013; originally announced November 2013.

    Comments: Proceedings of the 4th International Conference on Directional Dark Matter Detection CYGNUS2013, held in Toyoma (Japan), June 2013

  5. arXiv:1310.6837  [pdf

    physics.ins-det nucl-ex

    Measurement of a 127 keV Neutron Field with a micro-TPC Spectrometer

    Authors: D. Maire, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, L. Lebreton, F. Mayet, J. Médard, J. F. Muraz, M. Petit, J. P. Richer, Q. Riffard, D. Santos

    Abstract: In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector princip… ▽ More

    Submitted 7 January, 2014; v1 submitted 25 October, 2013; originally announced October 2013.

    Comments: 7 pages. Submitted in IEEE TNS/ Special Issue ANIMMA 2013

  6. arXiv:1310.5923  [pdf

    physics.ins-det nucl-ex

    Development of a microtpc detector as a standard instrument for low energy neutron field characterization

    Authors: D. Maire, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, L. Lebreton, F. Mayet, J. Médard, J-F. Muraz, J-P. Richer, Q. Riffard, D. Santos

    Abstract: In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track rec… ▽ More

    Submitted 22 October, 2013; originally announced October 2013.

    Comments: Neudos12 symposium proceeding. 4 pages

    Journal ref: Radiat. Prot. Dosimetry 161 (2014) 245

  7. arXiv:1306.4173  [pdf, other

    astro-ph.IM astro-ph.CO physics.ins-det

    Dark Matter directional detection with MIMAC

    Authors: Q. Riffard, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, F. Mayet, J. -F. Muraz, J. -P. Richer, D. Santos, L. Lebreton, D. Maire, J. Busto, J. Brunner, D. Fouchez

    Abstract: Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters. The MIMAC project, based on a \textmu-TPC matrix, with… ▽ More

    Submitted 18 June, 2013; originally announced June 2013.

    Comments: Proceedings of the 48th Rencontres de Moriond: Very High Energy Phenomena in the Universe, 9-16 March 2013, La Thuile, Italy

    Report number: LPSC13144

  8. arXiv:1305.2360  [pdf, ps, other

    astro-ph.IM physics.ins-det

    In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

    Authors: J. Billard, F. Mayet, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by… ▽ More

    Submitted 28 January, 2014; v1 submitted 10 May, 2013; originally announced May 2013.

    Comments: 19 pages, 14 figures. Minor corrections, matches published version in JINST

    Journal ref: JINST 9 (2014) P01013

  9. arXiv:1304.2255  [pdf, other

    physics.ins-det astro-ph.CO

    MIMAC: A micro-tpc matrix for dark matter directional detection

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, C. Fourel, O. Guillaudin, J. Lamblin, J. F. Muraz, F. Mayet, J. P. Richer, Q. Riffard, E. Ferrer, I. Giomataris, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based o… ▽ More

    Submitted 8 April, 2013; originally announced April 2013.

    Comments: Proceedings of the 6th Symposium on Large TPCs for low energy rare event detection, Paris, December 2012

  10. A μ-TPC detector for the characterization of low energy neutron fields

    Authors: C. Golabek, J. Billard, A. Allaoua, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, L. Lebreton, F. Mayet, M. Petit, J. -P. Richer, D. Santos

    Abstract: The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up… ▽ More

    Submitted 12 March, 2012; originally announced March 2012.

    Journal ref: Nucl. Instrum. Meth. A678 (2012) 33-38

  11. arXiv:1111.1566  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC: A micro-tpc matrix project for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of… ▽ More

    Submitted 7 November, 2011; originally announced November 2011.

    Comments: Proceedings of the 3rd International Conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois- France- June 2011

  12. arXiv:1109.1675  [pdf, other

    physics.ins-det astro-ph.IM

    Micromegas detector developments for MIMAC

    Authors: E. Ferrer-Ribas, D. Attié, D. Calvet, P. Colas, F. Druillole, Y. Giomataris, F. J. Iguaz, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.

    Submitted 12 September, 2011; v1 submitted 8 September, 2011; originally announced September 2011.

    Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations

  13. Micromegas detector developments for Dark Matter directional detection with MIMAC

    Authors: F. J. Iguaz, D. Attié, D. Calvet, P. Colas, F. Druillole, E. Ferrer-Ribas, I. Giomataris, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.

    Submitted 10 May, 2011; originally announced May 2011.

    Comments: 12 pages, 12 figures

    Journal ref: JINST 6:P07002,2011

  14. MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. T… ▽ More

    Submitted 16 February, 2011; originally announced February 2011.

    Comments: 6 pages, Proc. of the fifth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2010. To appear in Journal of Physics

    Report number: LPSC10223

    Journal ref: J.Phys.Conf.Ser. 309 (2011) 012014

  15. arXiv:1012.1166  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, A. Allaoua, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or… ▽ More

    Submitted 6 December, 2010; originally announced December 2010.

    Comments: Proceedings of Identification of Dark Matter 2010-IDM2010 conference

  16. arXiv:1001.2983  [pdf, ps, other

    astro-ph.CO astro-ph.IM

    Directional detection of galactic Dark Matter

    Authors: F. Mayet, J. Billard, G. Bernard, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, C. Koumeir, J. P. Richer, D. Santos, P. Colas, E. Ferer, I. Giomataris, A. Allaoua, L. Lebreton

    Abstract: Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.

    Submitted 18 January, 2010; originally announced January 2010.

    Comments: Proceedings of the 12th Marcel Grossmann Meeting on General Relativity (MG 12), Paris, France, 12-18 Jul 2009

  17. arXiv:0909.0654  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)

    Authors: C. Grignon, G. Bernard, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, C. Koumeir, F. Mayet, D. Santos, P. Colas, E. Ferrer, I. Giomataris, A. Allaoua, L. Lebreton

    Abstract: We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are… ▽ More

    Submitted 30 October, 2009; v1 submitted 3 September, 2009; originally announced September 2009.

    Comments: 5 pages, proc. of the 1st International Conference on Micro Pattern Gaseous Detectors MPGD 2009, 12-15 June 2009, Kolympari, Crete, Greece

    Journal ref: JINST 4:P11003,2009

  18. Novel recoil nuclei detectors to qualify the AMANDE facility as a Standard for mono-energetic neutron fields

    Authors: A. Allaoua, O. Guillaudin, S. Higueret, D. Husson, L. Lebreton, F. Mayet, M. Nourreddine, D. Santos, A. Trichet

    Abstract: The AMANDE facility at IRSN-Cadarache produces mono-energetic neutron fields from 2 keV to 20 MeV with metrological quality. To be considered as a standard facility, characteristics of neutron field i.e fluence distribution must be well known by a device using absolute measurements. The development of new detector systems allowing a direct measurement of neutron energy and fluence has started in… ▽ More

    Submitted 1 December, 2008; originally announced December 2008.

    Comments: to appear in Radiation Measurements, Proc. of 24th International Conference on Nuclear Tracks in Solids (Bologna, 1-5 September 2008)

    Journal ref: Radiat.Meas.44:755-758,2009