Skip to main content

Showing 1–3 of 3 results for author: Lapolla, P M

.
  1. arXiv:1001.4610  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    The linearity response of the Planck-LFI flight model receivers

    Authors: A. Mennella, F. Villa, L. Terenzi, F. Cuttaia, P. Battaglia, M. Bersanelli, R. C. Butler, O. D'Arcangelo, E. Artal, R. Davis, M. Frailis, C. Franceschet, S. Galeotta, A. Gregorio, N. Hughes, P. Jukkala, D. Kettle, V. -H. Kilpiä, M. Laaninen, P. M. Lapolla, R. Leonardi, P. Leutenegger, S. Lowe, N. Mandolesi, M. Maris , et al. (15 additional authors not shown)

    Abstract: In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best para… ▽ More

    Submitted 26 January, 2010; originally announced January 2010.

    Comments: this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st; This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12011.

    Journal ref: 2009 JINST 4 T12011

  2. Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

    Authors: A. Mennella, M. Bersanelli, R. C. Butler, F. Cuttaia, O. D'Arcangelo, R. J. Davis, M. Frailis, S. Galeotta, A. Gregorio, C. R. Lawrence, R. Leonardi, S. R. Lowe, N. Mandolesi, M. Maris, P. Meinhold, L. Mendes, G. Morgante, M. Sandri, L. Stringhetti, L. Terenzi, M. Tomasi, L. Valenziano, F. Villa, A. Zacchei, A. Zonca , et al. (61 additional authors not shown)

    Abstract: We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise… ▽ More

    Submitted 25 January, 2010; originally announced January 2010.

    Comments: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010)

  3. arXiv:1001.3321  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    Planck pre-launch status: Design and description of the Low Frequency Instrument

    Authors: M. Bersanelli, N. Mandolesi, R. C. Butler, A. Mennella, F. Villa, B. Aja, E. Artal, E. Artina, C. Baccigalupi, M. Balasini, G. Baldan, A. Banday, P. Bastia, P. Battaglia, T. Bernardino, E. Blackhurst, L. Boschini, C. Burigana, G. Cafagna, B. Cappellini, F. Cavaliere, F. Colombo, G. Crone, F. Cuttaia, O. D'Arcangelo , et al. (87 additional authors not shown)

    Abstract: In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI… ▽ More

    Submitted 19 January, 2010; originally announced January 2010.

    Comments: 23 pages, 31 figures, accepted by Astronomy and Astrophysics, Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221