-
MICADO: The Multi-Adaptive Optics Camera for Deep Observations
Authors:
Richard Davies,
Veronika Hoermann,
Sebastian Rabien,
Eckhard Sturm,
Joao Alves,
Yann Clenet,
Jari Kotilainen,
Florian Lang-Bardl,
Harald Nicklas,
Joerg-Uwe Pott,
Eline Tolstoy,
MICADO Consortium
Abstract:
The Multi-adaptive optics Imaging CamerA for Deep Observations (MICADO) will image a field of view of nearly 1 arcminute at the diffraction limit of the Extremely Large Telescope (ELT), making use of the adaptive optics correction provided by single-conjugate adaptive optics (SCAO) and multi-conjugate adaptive optics (MCAO). Its simple and robust design will yield an unprecedented combination of s…
▽ More
The Multi-adaptive optics Imaging CamerA for Deep Observations (MICADO) will image a field of view of nearly 1 arcminute at the diffraction limit of the Extremely Large Telescope (ELT), making use of the adaptive optics correction provided by single-conjugate adaptive optics (SCAO) and multi-conjugate adaptive optics (MCAO). Its simple and robust design will yield an unprecedented combination of sensitivity and resolution across the field. This article outlines the characteristics of the observing modes offered and illustrates each of them with an astrophysical application. Potential users can explore their own ideas using the data simulator ScopeSim.
△ Less
Submitted 22 March, 2021;
originally announced March 2021.
-
The MICADO first light imager for the ELT: overview, operation, simulation
Authors:
Richard Davies,
João Alves,
Yann Clénet,
Florian Lang-Bardl,
Harald Nicklas,
Jörg-Uwe Pott,
Roberto Ragazzoni,
Eline Tolstoy,
Paola Amico,
Heiko Anwand-Heerwart,
Santiago Barboza,
Lothar Barl,
Pierre Baudoz,
Ralf Bender,
Naidu Bezawada,
Peter Bizenberger,
Wilfried Boland,
Piercarlo Bonifacio,
Bruno Borgo,
Tristan Buey,
Frédéric Chapron,
Fanny Chemla,
Mathieu Cohen,
Oliver Czoske,
Vincent Deo
, et al. (76 additional authors not shown)
Abstract:
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and m…
▽ More
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and making use of the data simulation tool, an outline is presented of what we can expect the instrument to achieve.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
MICADO: first light imager for the E-ELT
Authors:
R. Davies,
J. Schubert,
M. Hartl,
J. Alves,
Y. Clénet,
F. Lang-Bardl,
H. Nicklas,
J. -U. Pott,
R. Ragazzoni,
E. Tolstoy,
T. Agocs,
H. Anwand-Heerwart,
S. Barboza,
P. Baudoz,
R. Bender,
P. Bizenberger,
A. Boccaletti,
W. Boland,
P. Bonifacio,
F. Briegel,
T. Buey,
F. Chapron,
M. Cohen,
O. Czoske,
S. Dreizler
, et al. (59 additional authors not shown)
Abstract:
MICADO will equip the E-ELT with a first light capability for diffraction limited imaging at near-infrared wavelengths. The instrument's observing modes focus on various flavours of imaging, including astrometric, high contrast, and time resolved. There is also a single object spectroscopic mode optimised for wavelength coverage at moderately high resolution. This contribution provides an overview…
▽ More
MICADO will equip the E-ELT with a first light capability for diffraction limited imaging at near-infrared wavelengths. The instrument's observing modes focus on various flavours of imaging, including astrometric, high contrast, and time resolved. There is also a single object spectroscopic mode optimised for wavelength coverage at moderately high resolution. This contribution provides an overview of the key functionality of the instrument, outlining the scientific rationale for its observing modes. The interface between MICADO and the adaptive optics system MAORY that feeds it is summarised. The design of the instrument is discussed, focussing on the optics and mechanisms inside the cryostat, together with a brief overview of the other key sub-systems.
△ Less
Submitted 7 July, 2016;
originally announced July 2016.
-
The 64 Mpixel wide field imager for the Wendelstein 2m Telescope: Design and Calibration
Authors:
Ralf Kosyra,
Claus Goessl,
Ulrich Hopp,
Florian Lang-Bardl,
Arno Riffeser,
Ralf Bender,
Stella Seitz
Abstract:
The Wendelstein Observatory of Ludwig Maximilians University of Munich has recently been upgraded with a modern 2m robotic telescope. One Nasmyth port of the telescope has been equipped with a wide-field corrector which preserves the excellent image quality (< 0.8" median seeing) of the site (Hopp et al. 2008) over a field of view of 0.7 degrees diameter. The available field is imaged by an optica…
▽ More
The Wendelstein Observatory of Ludwig Maximilians University of Munich has recently been upgraded with a modern 2m robotic telescope. One Nasmyth port of the telescope has been equipped with a wide-field corrector which preserves the excellent image quality (< 0.8" median seeing) of the site (Hopp et al. 2008) over a field of view of 0.7 degrees diameter. The available field is imaged by an optical imager (WWFI, the Wendelstein Wide Field Imager) built around a customized 2 $\times$ 2 mosaic of 4k $\times$ 4k 15 μm e2v CCDs from Spectral Instruments. This paper provides an overview of the design and the WWFI's performance. We summarize the system mechanics (including a structural analysis), the electronics (and its electromagnetic interference (EMI) protection) and the control software. We discuss in detail detector system parameters, i.e. gain and readout noise, quantum efficiency as well as charge transfer efficiency (CTE) and persistent charges. First on sky tests yield overall good predictability of system throughput based on lab measurements.
△ Less
Submitted 11 August, 2014;
originally announced August 2014.
-
4MOST - 4-metre Multi-Object Spectroscopic Telescope
Authors:
Roelof S. de Jong,
Olga Bellido-Tirado,
Cristina Chiappini,
Éric Depagne,
Roger Haynes,
Diane Johl,
Olivier Schnurr,
Axel Schwope,
Jakob Walcher,
Frank Dionies,
Dionne Haynes,
Andreas Kelz,
Francisco S. Kitaura,
Georg Lamer,
Ivan Minchev,
Volker Müller,
Sebastián E. Nuza,
Jean-Christophe Olaya,
Tilmann Piffl,
Emil Popow,
Matthias Steinmetz,
Uğur Ural,
Mary Williams,
Roland Winkler,
Lutz Wisotzki
, et al. (60 additional authors not shown)
Abstract:
The 4MOST consortium is currently halfway through a Conceptual Design study for ESO with the aim to develop a wide-field (>3 square degree, goal >5 square degree), high-multiplex (>1500 fibres, goal 3000 fibres) spectroscopic survey facility for an ESO 4m-class telescope (VISTA). 4MOST will run permanently on the telescope to perform a 5 year public survey yielding more than 20 million spectra at…
▽ More
The 4MOST consortium is currently halfway through a Conceptual Design study for ESO with the aim to develop a wide-field (>3 square degree, goal >5 square degree), high-multiplex (>1500 fibres, goal 3000 fibres) spectroscopic survey facility for an ESO 4m-class telescope (VISTA). 4MOST will run permanently on the telescope to perform a 5 year public survey yielding more than 20 million spectra at resolution R~5000 (λ=390-1000 nm) and more than 2 million spectra at R~20,000 (395-456.5 nm & 587-673 nm). The 4MOST design is especially intended to complement three key all-sky, space-based observatories of prime European interest: Gaia, eROSITA and Euclid. Initial design and performance estimates for the wide-field corrector concepts are presented. We consider two fibre positioner concepts, a well-known Phi-Theta system and a new R-Theta concept with a large patrol area. The spectrographs are fixed configuration two-arm spectrographs, with dedicated spectrographs for the high- and low-resolution. A full facility simulator is being developed to guide trade-off decisions regarding the optimal field-of-view, number of fibres needed, and the relative fraction of high-to-low resolution fibres. Mock catalogues with template spectra from seven Design Reference Surveys are simulated to verify the science requirements of 4MOST. The 4MOST consortium aims to deliver the full 4MOST facility by the end of 2018 and start delivering high-level data products for both consortium and ESO community targets a year later with yearly increments.
△ Less
Submitted 28 June, 2012;
originally announced June 2012.