-
Deuterated Polystyrene -- Synthesis and uses for ultracold neutron bottles and the neutron EDM experiment
Authors:
Steve K. Lamoreaux
Abstract:
The synthesis and application of deuterated polystyrene (dps) films is discussed. Ultracold neutron storage properties and the Fermi potential of dps films is measured with the result that Tstore=700 +/- 200 sec for dps in the bottle used and the Fermi potential is about 165neV. The behavior under application of high electric fields in vacuum is measured; the films are sufficiently stable to use i…
▽ More
The synthesis and application of deuterated polystyrene (dps) films is discussed. Ultracold neutron storage properties and the Fermi potential of dps films is measured with the result that Tstore=700 +/- 200 sec for dps in the bottle used and the Fermi potential is about 165neV. The behavior under application of high electric fields in vacuum is measured; the films are sufficiently stable to use in a neutron EDM bottle. Also, the relaxation rate of nuclear spin polarized 199Hg on dps films is measured giving a wall lifetime of 20 sec/cm mean free path, which should make the development of an Hg volume magnetometer possible.
△ Less
Submitted 9 February, 2024;
originally announced February 2024.
-
Hidden Variables: Rehabilitation of von Neumann's Analysis, and Pauli's Uncashable Check
Authors:
Robert Golub,
Steve K. Lamoreaux
Abstract:
In his book \textit{The Mathematical Foundations of Quantum Mechanics}, published in 1932, J. von Neumann performed an analysis of the consequences of introducing hidden parameters (hidden variables) into quantum mechanics. He showed that hidden variables cannot be incorporated into the existing theory of quantum mechanics without major modifications, and concluded that if they did exist, the theo…
▽ More
In his book \textit{The Mathematical Foundations of Quantum Mechanics}, published in 1932, J. von Neumann performed an analysis of the consequences of introducing hidden parameters (hidden variables) into quantum mechanics. He showed that hidden variables cannot be incorporated into the existing theory of quantum mechanics without major modifications, and concluded that if they did exist, the theory would have already failed in situations where it has been successfully applied. von Neumann left open the possibility that the theory is not complete, and his analysis for internal consistency is the best that can be done for a self-referenced logical system (Gödel's theorem). This analysis had been taken as an ``incorrect proof" against the existence of hidden variables. von Neumann's so-called proof isn't even wrong as such a proof does not exist. One of the earliest attempts at a hidden variable theory was by D. Bohm, and because there were no experimental consequences, W. Pauli referred to it as an ``uncashable check." To our knowledge, a successful hidden variable extension to quantum mechanics with testable consequences has not yet been produced, suggesting that von Neumann's analysis is worthy of rehabilitation, which we attempt to provide in a straightforward manner.
△ Less
Submitted 22 March, 2024; v1 submitted 8 January, 2024;
originally announced January 2024.
-
Quantum Sensors for High Energy Physics
Authors:
Aaron Chou,
Kent Irwin,
Reina H. Maruyama,
Oliver K. Baker,
Chelsea Bartram,
Karl K. Berggren,
Gustavo Cancelo,
Daniel Carney,
Clarence L. Chang,
Hsiao-Mei Cho,
Maurice Garcia-Sciveres,
Peter W. Graham,
Salman Habib,
Roni Harnik,
J. G. E. Harris,
Scott A. Hertel,
David B. Hume,
Rakshya Khatiwada,
Timothy L. Kovachy,
Noah Kurinsky,
Steve K. Lamoreaux,
Konrad W. Lehnert,
David R. Leibrandt,
Dale Li,
Ben Loer
, et al. (17 additional authors not shown)
Abstract:
Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Sta…
▽ More
Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Standard Model itself including the Strong CP problem in QCD. Resulting experimental needs typically involve the measurement of very low energy impulses or low power periodic signals that are normally buried under large backgrounds. This report documents the findings of the 2023 Quantum Sensors for High Energy Physics workshop which identified enabling quantum information science technologies that could be utilized in future particle physics experiments, targeting high energy physics science goals.
△ Less
Submitted 3 November, 2023;
originally announced November 2023.
-
On the use of dielectric elements in axion searches with microwave resonant cavities
Authors:
Xiran Bai,
Michael J. Jewell,
Steve K. Lamoreaux,
Reina H. Maruyama,
Karl van Bibber
Abstract:
This study explores the primary effects of dielectric materials in a resonant cavity-based search for axion dark matter. While dielectrics prove beneficial in numerous cases, their incorporation may lead to less-than-optimal performance, especially for the lowest TM mode. Additionally, the stronger confinement of the electric field inside the dielectrics can exacerbate mode mixings, in particular…
▽ More
This study explores the primary effects of dielectric materials in a resonant cavity-based search for axion dark matter. While dielectrics prove beneficial in numerous cases, their incorporation may lead to less-than-optimal performance, especially for the lowest TM mode. Additionally, the stronger confinement of the electric field inside the dielectrics can exacerbate mode mixings, in particular for higher-order modes. Case studies have been carried out using a combination of analytical solutions and numerical simulations. The findings indicate dielectric cavities employing the $\text{TM}_{010}$ mode experience a significant reduction in sensitivity when compared to a similar search conducted in a cavity at equivalent frequency using no dielectrics.
△ Less
Submitted 13 April, 2023;
originally announced April 2023.
-
New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver
Authors:
HAYSTAC Collaboration,
M. J. Jewell,
A. F. Leder,
K. M. Backes,
Xiran Bai,
K. van Bibber,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Maryam H. Esmat,
Sumita Ghosh,
Eleanor Graham,
Gene C. Hilton,
H. Jackson,
Claire Laffan,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
E. P. Ruddy,
M. Simanovskaia,
Sukhman Singh
, et al. (4 additional authors not shown)
Abstract:
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr…
▽ More
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.
△ Less
Submitted 26 January, 2023; v1 submitted 23 January, 2023;
originally announced January 2023.
-
An improved synthetic signal injection routine for the Haloscope At Yale Sensitive To Axion Cold dark matter (HAYSTAC)
Authors:
Yuqi Zhu,
M. J. Jewell,
Claire Laffan,
Xiran Bai,
Sumita Ghosh,
Eleanor Graham,
S. B. Cahn,
Reina H. Maruyama,
S. K. Lamoreaux
Abstract:
Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion-photon conversion is on the order of $10^{-24}$~W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful…
▽ More
Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion-photon conversion is on the order of $10^{-24}$~W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful. Here we present a method based on frequency hop** spread spectrum for synthesizing axion signals in a microwave cavity haloscope experiment. It allows us to generate a narrow and asymmetric shape in frequency space that mimics an axion's spectral distribution, which is derived from a Maxwell-Boltzmann distribution. In addition, we show that the synthetic axion's power can be calibrated with reference to the system noise. Compared to the synthetic axion injection in HAYSTAC phase I, we demonstrated synthetic signal injection with a more realistic lineshape and calibrated power.
△ Less
Submitted 12 May, 2023; v1 submitted 1 December, 2022;
originally announced December 2022.
-
A quantum-enhanced search for dark matter axions
Authors:
K. M. Backes,
D. A. Palken,
S. Al Kenany,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Gene C. Hilton,
Sumita Ghosh,
H. Jackson,
S. K. Lamoreaux,
A. F. Leder,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
N. M. Rapidis,
M. Simanovskaia,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
Leila R. Vale,
E. C. van Assendelft,
K. van Bibber,
H. Wang
Abstract:
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we do…
▽ More
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.
△ Less
Submitted 4 August, 2020;
originally announced August 2020.
-
An improved analysis framework for axion dark matter searches
Authors:
D. A. Palken,
B. M. Brubaker,
M. Malnou,
S. Al Kenany,
K. M. Backes,
S. B. Cahn,
Y. V. Gurevich,
S. K. Lamoreaux,
S. M. Lewis,
R. H. Maruyama,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
K. van Bibber,
L. Zhong,
K. W. Lehnert
Abstract:
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f…
▽ More
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.
△ Less
Submitted 28 July, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.
-
A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment
Authors:
M. W. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baessler,
L. Barron-Palos,
L. M. Bartoszek,
D. H. Beck,
M. Behzadipour,
I. Berkutov,
J. Bessuille,
M. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallati…
▽ More
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.
△ Less
Submitted 20 November, 2019; v1 submitted 26 August, 2019;
originally announced August 2019.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
Stored Ultracold Neutron Lifetime Experiments: Non-Inertial Frame Effects on the Neutron Velocity Spectrum
Authors:
Steve K. Lamoreaux
Abstract:
Ultracold neutrons (UCN), stored in a cell with hard walls that is attached to, and therefore rotating with, the Earth, will experience non-inertial frame effects, resulting in a broadening of the UCN spectrum. A heating or cooling of the spectrum is also possible. This is because the stored UCN are in a freely falling (inertial) frame between sudden wall collisions, and the acceleration of the ce…
▽ More
Ultracold neutrons (UCN), stored in a cell with hard walls that is attached to, and therefore rotating with, the Earth, will experience non-inertial frame effects, resulting in a broadening of the UCN spectrum. A heating or cooling of the spectrum is also possible. This is because the stored UCN are in a freely falling (inertial) frame between sudden wall collisions, and the acceleration of the cell relative to this frame means that the cell walls will have a new quasi-random velocities between subsequent UCN wall collisions. This results in a random walk of UCN trajectories in momentum space. Estimates of the effects on UCN with specified initial velocities are presented. Although the effects appear as small, they are worth considering for experiments of current interest, and will be important for possible future experiments with anticipated improved accuracy.
△ Less
Submitted 2 April, 2018;
originally announced April 2018.
-
Results from phase 1 of the HAYSTAC microwave cavity axion experiment
Authors:
L. Zhong,
S. Al Kenany,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
D. H. Speller,
I. Urdinaran,
K. A. van Bibber
Abstract:
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range…
▽ More
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment
Authors:
T. M. Ito,
E. R. Adamek,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
X. Ding,
D. E. Fellers,
P. Geltenbort,
S. K. Lamoreaux,
C. Y. Liu,
S. MacDonald,
M. Makela,
C. L. Morris,
R. W. Pattie Jr.,
J. C. Ramsey,
D. J. Salvat,
A. Saunders,
E. I. Sharapov,
S. Sjue,
A. P. Sprow,
Z. Tang,
H. L. Weaver,
W. Wei
, et al. (1 additional authors not shown)
Abstract:
The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the…
▽ More
The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was $184(32)$ UCN/cm$^3$, a four-fold increase from the highest previously reported. The polarized UCN density stored in an external chamber was measured to be $39(7)$ UCN/cm$^3$, which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of $σ(d_n) = 3\times 10^{-27}$ $e\cdot$cm.
△ Less
Submitted 16 January, 2018; v1 submitted 14 October, 2017;
originally announced October 2017.
-
The HAYSTAC Axion Search Analysis Procedure
Authors:
B. M. Brubaker,
L. Zhong,
S. K. Lamoreaux,
K. W. Lehnert,
K. A. van Bibber
Abstract:
We describe in detail the analysis procedure used to derive the first limits from the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a microwave cavity search for cold dark matter (CDM) axions with masses above $20\ μ\text{eV}$. We have introduced several significant innovations to the axion search analysis pioneered by the Axion Dark Matter eXperiment (ADMX), including optimal filtering of t…
▽ More
We describe in detail the analysis procedure used to derive the first limits from the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a microwave cavity search for cold dark matter (CDM) axions with masses above $20\ μ\text{eV}$. We have introduced several significant innovations to the axion search analysis pioneered by the Axion Dark Matter eXperiment (ADMX), including optimal filtering of the individual power spectra that constitute the axion search dataset and a consistent maximum likelihood procedure for combining and rebinning these spectra. These innovations enable us to obtain the axion-photon coupling $|g_γ|$ excluded at any desired confidence level directly from the statistics of the combined data.
△ Less
Submitted 22 December, 2017; v1 submitted 26 June, 2017;
originally announced June 2017.
-
Recent Technical Improvements to the HAYSTAC Experiment
Authors:
L. Zhong,
B. M. Brubaker,
S. B. Cahn,
S. K. Lamoreaux
Abstract:
We report here several technical improvements to the HAYSTAC (Haloscope at Yale Sensitive To Axion Cold dark matter) that have improved operational efficiency, sensitivity, and stability.
We report here several technical improvements to the HAYSTAC (Haloscope at Yale Sensitive To Axion Cold dark matter) that have improved operational efficiency, sensitivity, and stability.
△ Less
Submitted 7 August, 2017; v1 submitted 12 June, 2017;
originally announced June 2017.
-
Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
Authors:
S. Al Kenany,
M. A. Anil,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
I. Urdinaran,
K. A. van Bibber,
L. Zhong
Abstract:
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple…
▽ More
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.
△ Less
Submitted 22 February, 2017; v1 submitted 21 November, 2016;
originally announced November 2016.
-
First results from a microwave cavity axion search at 24 micro-eV
Authors:
B. M. Brubaker,
L. Zhong,
Y. V. Gurevich,
S. B. Cahn,
S. K. Lamoreaux,
M. Simanovskaia,
J. R. Root,
S. M. Lewis,
S. Al Kenany,
K. M. Backes,
I. Urdinaran,
N. M. Rapidis,
T. M. Shokair,
K. A. van Bibber,
D. A. Palken,
M. Malnou,
W. F. Kindel,
M. A. Anil,
K. W. Lehnert,
G. Carosi
Abstract:
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an orde…
▽ More
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.
△ Less
Submitted 9 February, 2017; v1 submitted 8 October, 2016;
originally announced October 2016.
-
Experimental Searches for the Axion and Axion-like Particles
Authors:
Peter W. Graham,
Igor G. Irastorza,
Steven K. Lamoreaux,
Axel Lindner,
Karl A. van Bibber
Abstract:
Four decades after its prediction, the axion remains the most compelling solution to the Strong-CP problem and a well-motivated dark matter candidate, inspiring a host of elegant and ultrasensitive experiments based on axion-photon mixing. This report reviews the experimental situation on several fronts. The microwave cavity experiment is making excellent progress in the search for dark matter axi…
▽ More
Four decades after its prediction, the axion remains the most compelling solution to the Strong-CP problem and a well-motivated dark matter candidate, inspiring a host of elegant and ultrasensitive experiments based on axion-photon mixing. This report reviews the experimental situation on several fronts. The microwave cavity experiment is making excellent progress in the search for dark matter axions in the microelectronvolt range and may be plausibly extended up to 100 mu eV. Within the past several years however, it has been realized that axions are pervasive throughout string theories, but with masses that fall naturally in the nanoelectronvolt range, for which a NMR-based search is under development. Searches for axions emitted from the Sun's burning core, and purely laboratory experiments based on photon regeneration have both made great strides in recent years, with ambitious projects proposed for the coming decade. Each of these campaigns has pushed the state of the art in technology, enabling large gains in sensitivity and mass reach. Furthermore each modality has also been exploited to search for more generalized axion-like particles, that will also be discussed in this report. We are hopeful, even optimistic, that the next review of the subject will concern the discovery of the axion, its properties, and its exploitation as a probe of early universe cosmology and structure formation.
△ Less
Submitted 29 January, 2016;
originally announced February 2016.
-
Future Directions in the Microwave Cavity Search for Dark Matter Axions
Authors:
T. M. Shokair,
J. Root,
K. A. Van Bibber,
B. Brubaker,
Y. V. Gurevich,
S. B. Cahn,
S. K. Lamoreaux,
M. A. Anil,
K. W. Lehnert,
B. K. Mitchell,
A. Reed,
G. Carosi
Abstract:
The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrate…
▽ More
The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrated sensitivity to plausible axion models, and upgrades in progress should achieve the sensitivity required for a definitive search, at least for low mass axions. However, a comprehensive strategy for scanning the entire mass range, from 1-1000 $μ$eV, will require significant technological advances to maintain the needed sensitivity at higher frequencies. Such advances could include sub-quantum-limited amplifiers based on squeezed vacuum states, bolometers, and/or superconducting microwave cavities. The Axion Dark Matter eXperiment at High Frequencies (ADMX-HF) represents both a pathfinder for first data in the 20-100 $μ$eV range ($\sim$5-25 GHz), and an innovation test-bed for these concepts.
△ Less
Submitted 14 May, 2014;
originally announced May 2014.
-
Stabilizing a Fabry-Perot etalon to 3 cm/s for spectrograph calibration
Authors:
Christian Schwab,
Julian Stuermer,
Yulia V. Gurevich,
Thorsten Fuehrer,
Steve K. Lamoreaux,
Thomas Walther,
Andreas Quirrenbach
Abstract:
We present a method of frequency stabilizing a broadband etalon that can serve as a high-precision wavelength calibrator for an Echelle spectrograph. Using a laser to probe the Doppler-free saturated absorption of the rubidium D2 line, we stabilize one etalon transmission peak directly to the rubidium frequency. The rubidium transition is an established frequency standard and has been used to lock…
▽ More
We present a method of frequency stabilizing a broadband etalon that can serve as a high-precision wavelength calibrator for an Echelle spectrograph. Using a laser to probe the Doppler-free saturated absorption of the rubidium D2 line, we stabilize one etalon transmission peak directly to the rubidium frequency. The rubidium transition is an established frequency standard and has been used to lock lasers to fractional stabilities of $<10^{-12}$, a level of accuracy far exceeding the demands of radial velocity (RV) searches for exoplanets. We describe a simple setup designed specifically for use at an observatory and demonstrate that we can stabilize the etalon peak to a relative precision of $<10^{-10}$; this is equivalent to 3 cm/s RV precision.
△ Less
Submitted 31 March, 2014;
originally announced April 2014.
-
Analysis of single-photon and linear amplifier detectors for microwave cavity dark matter axion searches
Authors:
S. K. Lamoreaux,
K. A. van Bibber,
K. W. Lehnert,
G. Carosi
Abstract:
We show that at higher frequencies, and thus higher axion masses, single-photon detectors become competitive and ultimately favored, when compared to quantum-limited linear amplifiers, as the detector technology in microwave cavity experimental searches for galactic halo dark matter axions. The cross-over point in this comparison is of order 10 GHz ($\sim 40\ μ$eV), not far above the frequencies o…
▽ More
We show that at higher frequencies, and thus higher axion masses, single-photon detectors become competitive and ultimately favored, when compared to quantum-limited linear amplifiers, as the detector technology in microwave cavity experimental searches for galactic halo dark matter axions. The cross-over point in this comparison is of order 10 GHz ($\sim 40\ μ$eV), not far above the frequencies of current searches.
△ Less
Submitted 3 August, 2013; v1 submitted 15 June, 2013;
originally announced June 2013.
-
Apparatus for Measurement of the Electric Dipole Moment of the Neutron using a Cohabiting Atomic-Mercury Magnetometer
Authors:
C. A. Baker,
Y. Chibane,
M. Chouder,
P. Geltenbort,
K. Green,
P. G. Harris,
B. R. Heckel,
P. Iaydjiev,
S. N. Ivanov,
I. Kilvington,
S. K. Lamoreaux,
D. J. May,
J. M. Pendlebury,
J. D. Richardson,
D. B. Shiers,
K. F. Smith,
M. van der Grinten
Abstract:
A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter; here, the methods and equipment use…
▽ More
A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter; here, the methods and equipment used are discussed in detail.
△ Less
Submitted 5 June, 2013; v1 submitted 31 May, 2013;
originally announced May 2013.
-
Time dependent spin-dressing using a $^3$He atomic beam
Authors:
S. Eckel,
S. K. Lamoreaux,
M. E. Hayden,
T. M. Ito
Abstract:
We have performed high precision experimental measurements of spin precession using a dressed $^3$He atomic beam. Spin-dressing uses an oscillating magnetic field detuned to high frequency which is orthogonal to a static magnetic field to effectively change the gyromagnetic ratio of a spin. We verify the validity of the spin-dressing Hamiltonian in regions beyond the limiting solution in which the…
▽ More
We have performed high precision experimental measurements of spin precession using a dressed $^3$He atomic beam. Spin-dressing uses an oscillating magnetic field detuned to high frequency which is orthogonal to a static magnetic field to effectively change the gyromagnetic ratio of a spin. We verify the validity of the spin-dressing Hamiltonian in regions beyond the limiting solution in which the Larmor frequency is much smaller than the frequency of the dressing field. We also evaluate the effect of magnetic field misalignment, e.g. if the oscillating magnetic field is not orthogonal to the static magnetic field. Modulation of the dressing field parameters is also discussed, with a focus on whether such a modulation can be approximated merely as a time dependent, dressed gyromagnetic ratio. Furthermore, we discuss implications for a proposed search for the neutron electric dipole moment, which would employ spin-dressing to make the effective $^3$He and neutron magnetic moments equal.
△ Less
Submitted 24 August, 2012;
originally announced August 2012.
-
A limit on the electron electric dipole moment using paramagnetic ferroelectric Eu$_{0.5}$Ba$_{0.5}$TiO$_3$
Authors:
S. Eckel,
A. O. Sushkov,
S. K. Lamoreaux
Abstract:
We report on the results of a search for the electron electric dipole moment $d_e$ using paramagnetic ferroelectric Eu$_{0.5}$Ba$_{0.5}$TiO$_3$. The electric polarization creates an effective electric field that makes it energetically favorable for the spins of the seven unpaired $4f$ electrons of the Eu$^{2+}$ to orient along the polarization, provided that $d_e\neq 0$. This interaction gives ris…
▽ More
We report on the results of a search for the electron electric dipole moment $d_e$ using paramagnetic ferroelectric Eu$_{0.5}$Ba$_{0.5}$TiO$_3$. The electric polarization creates an effective electric field that makes it energetically favorable for the spins of the seven unpaired $4f$ electrons of the Eu$^{2+}$ to orient along the polarization, provided that $d_e\neq 0$. This interaction gives rise to sample magnetization, correlated with its electric polarization, and is therefore equivalent to a linear magnetoelectric effect. A SQUID magnetometer is used to search for the resulting magnetization. We obtain $d_e = (-1.07\pm3.06_\text{stat}\pm 1.74_\text{sys})\times10^{-25}\ecm$, implying an upper limit of $|d_e|<6.05\times10^{-25}\ecm$ (90% confidence).
△ Less
Submitted 18 November, 2012; v1 submitted 21 August, 2012;
originally announced August 2012.
-
New experimental limits on non-Newtonian forces in the micrometer-range
Authors:
A. O. Sushkov,
W. J. Kim,
D. A. R. Dalvit,
S. K. Lamoreaux
Abstract:
We report measurements of the short-range forces between two macroscopic gold-coated plates using a torsion pendulum. The force is measured for separations between 0.7 $μ$m and 7 $μ$m, and is well described by a combination of the Casimir force, including the finite-temperature correction, and an electrostatic force due to patch potentials on the plate surfaces. We use our data to place constraint…
▽ More
We report measurements of the short-range forces between two macroscopic gold-coated plates using a torsion pendulum. The force is measured for separations between 0.7 $μ$m and 7 $μ$m, and is well described by a combination of the Casimir force, including the finite-temperature correction, and an electrostatic force due to patch potentials on the plate surfaces. We use our data to place constraints on the Yukawa-type "new" forces predicted by theories with extra dimensions. We establish a new best bound for force ranges 0.4 $μ$m to 4 $μ$m, and, for forces mediated by gauge bosons propagating in $(4+n)$ dimensions and coupling to the baryon number, extract a $(4+n)$-dimensional Planck scale lower limit of $M_*>70$ TeV.
△ Less
Submitted 11 August, 2011;
originally announced August 2011.
-
On the Origin of the $\log d$ Variation of the Electrostatic Force Minimizing Voltage in Casimir Experiments
Authors:
S. K. Lamoreaux,
A. O. Sushkov
Abstract:
A number of experimental measurements of the Casimir force have observed a logarithmic distance variation of the voltage that minimizes electrostatic force between the plates in a sphere-plane geometry. We show that this variation can be simply understood from a geometric averaging of surface potential patches together with the Proximity Force Approximation.
A number of experimental measurements of the Casimir force have observed a logarithmic distance variation of the voltage that minimizes electrostatic force between the plates in a sphere-plane geometry. We show that this variation can be simply understood from a geometric averaging of surface potential patches together with the Proximity Force Approximation.
△ Less
Submitted 17 June, 2011;
originally announced June 2011.
-
Offsets in Electrostatically Determined Distances: Implications for Casimir Force Measurements
Authors:
S. K. Lamoreaux,
A. O. Sushkov
Abstract:
The imperfect termination of static electric fields at semiconducting surfaces has been long known in solid state and transistor physics. We show that the imperfect shielding leads to an offset in the distance between two surfaces as determined by electrostatic force measurements. The effect exists even in the case of good conductors (metals) albeit much reduced.
The imperfect termination of static electric fields at semiconducting surfaces has been long known in solid state and transistor physics. We show that the imperfect shielding leads to an offset in the distance between two surfaces as determined by electrostatic force measurements. The effect exists even in the case of good conductors (metals) albeit much reduced.
△ Less
Submitted 7 June, 2011;
originally announced June 2011.
-
New Experimental Limit on the Electric Dipole Moment of the Electron in a Paramagnetic Insulator
Authors:
Y. J. Kim,
C. -Y. Liu,
S. K. Lamoreaux,
G. Visser,
B. Kunkler,
A. N. Matlashov,
J. C. Long,
T. G. Reddy
Abstract:
We report results of an experimental search for the intrinsic Electric Dipole Moment (EDM) of the electron using a solid-state technique. The experiment employs a paramagnetic, insulating gadolinium gallium garnet (GGG) that has a large magnetic response at low temperatures. The presence of the eEDM would lead to a small but non-zero magnetization as the GGG sample is subject to a strong electric…
▽ More
We report results of an experimental search for the intrinsic Electric Dipole Moment (EDM) of the electron using a solid-state technique. The experiment employs a paramagnetic, insulating gadolinium gallium garnet (GGG) that has a large magnetic response at low temperatures. The presence of the eEDM would lead to a small but non-zero magnetization as the GGG sample is subject to a strong electric field. We search for the resulting Stark-induced magnetization with a sensitive magnetometer. Recent progress on the suppression of several sources of background allows the experiment to run free of spurious signals at the level of the statistical uncertainties. We report our first limit on the eEDM of $(-5.57 \pm 7.98 \pm 0.12)\times$10$^{-25}$e$\cdot$cm with 5 days of data averaging.
△ Less
Submitted 1 June, 2015; v1 submitted 22 April, 2011;
originally announced April 2011.
-
Observation of the thermal Casimir force
Authors:
A. O. Sushkov,
W. J. Kim,
D. A. R. Dalvit,
S. K. Lamoreaux
Abstract:
Quantum theory predicts the existence of the Casimir force between macroscopic bodies, due to the zero-point energy of electromagnetic field modes around them. This quantum fluctuation-induced force has been experimentally observed for metallic and semiconducting bodies, although the measurements to date have been unable to clearly settle the question of the correct low-frequency form of the diele…
▽ More
Quantum theory predicts the existence of the Casimir force between macroscopic bodies, due to the zero-point energy of electromagnetic field modes around them. This quantum fluctuation-induced force has been experimentally observed for metallic and semiconducting bodies, although the measurements to date have been unable to clearly settle the question of the correct low-frequency form of the dielectric constant dispersion (the Drude model or the plasma model) to be used for calculating the Casimir forces. At finite temperature a thermal Casimir force, due to thermal, rather than quantum, fluctuations of the electromagnetic field, has been theoretically predicted long ago. Here we report the experimental observation of the thermal Casimir force between two gold plates. We measured the attractive force between a flat and a spherical plate for separations between 0.7 $μ$m and 7 $μ$m. An electrostatic force caused by potential patches on the plates' surfaces is included in the analysis. The experimental results are in excellent agreement (reduced $χ^2$ of 1.04) with the Casimir force calculated using the Drude model, including the T=300 K thermal force, which dominates over the quantum fluctuation-induced force at separations greater than 3 $μ$m. The plasma model result is excluded in the measured separation range.
△ Less
Submitted 23 November, 2010;
originally announced November 2010.
-
Progress in Experimental Measurements of the Surface-Surface Casimir Force: Electrostatic Calibrations and Limitations to Accuracy
Authors:
Steve K. Lamoreaux
Abstract:
Several new experiments have extended studies of the Casimir force into new and interesting regimes. This recent work will be briefly reviewed. With this recent progress, new issues with background electrostatic effects have been uncovered. The myriad of problems associated with both patch potentials and electrostatic calibrations are discussed and the remaining open questions are brought forward.
Several new experiments have extended studies of the Casimir force into new and interesting regimes. This recent work will be briefly reviewed. With this recent progress, new issues with background electrostatic effects have been uncovered. The myriad of problems associated with both patch potentials and electrostatic calibrations are discussed and the remaining open questions are brought forward.
△ Less
Submitted 21 August, 2010;
originally announced August 2010.
-
Systematic Correction for "Demonstration of the Casimir Force in the 0.6 to 6 micrometer Range"
Authors:
S. K. Lamoreaux
Abstract:
A new systematic correction for Casimir force measurements is proposed and applied to the results of an experiment that was performed more than a decade ago. This correction brings the experimental results into good agreement with the Drude model of the metallic plates' permittivity. The systematic is due to time-dependent fluctuations in the distance between the plates caused by mechanical vibrat…
▽ More
A new systematic correction for Casimir force measurements is proposed and applied to the results of an experiment that was performed more than a decade ago. This correction brings the experimental results into good agreement with the Drude model of the metallic plates' permittivity. The systematic is due to time-dependent fluctuations in the distance between the plates caused by mechanical vibrations or tilt, or position measurement uncertainty, and is similar to the correction for plate roughness.
△ Less
Submitted 24 July, 2010;
originally announced July 2010.
-
Quantum dense coding without entanglement
Authors:
W. T. Buttler,
S. K. Lamoreaux,
J. R. Torgerson
Abstract:
We describe a quantum cryptography protocol with up to twenty four-dimensional ($\mathcal{D} =4$) states generated by a polarization-, phase- and time-encoding transmitter. This protocol can be experimentally realized with existing technology, drawing from time-encoded and polarization-encoded systems. The protocol is error tolerant and has a quantum bit-rate of 2 per transmission/detection, which…
▽ More
We describe a quantum cryptography protocol with up to twenty four-dimensional ($\mathcal{D} =4$) states generated by a polarization-, phase- and time-encoding transmitter. This protocol can be experimentally realized with existing technology, drawing from time-encoded and polarization-encoded systems. The protocol is error tolerant and has a quantum bit-rate of 2 per transmission/detection, which when combined with state detection efficiency yields a qubit efficiency of up to 1 or double that of BB84-{\it like} protocols.
△ Less
Submitted 4 May, 2010; v1 submitted 1 March, 2010;
originally announced March 2010.
-
First-principles design and subsequent synthesis of a material to search for the permanent electric dipole moment of the electron
Authors:
K. Z. Rushchanskii,
S. Kamba,
V. Goian,
P. Vanvek,
M. Savinov,
J. Provlevska,
D. Nuzhnyy,
K. Knivsek,
F. Laufek,
S. Eckel,
S. K. Lamoreaux,
A. O. Sushkov,
M. Lezaic,
N. A. Spaldin
Abstract:
We describe the first-principles design and subsequent synthesis of a new material with the specific functionalities required for a solid-state-based search for the permanent electric dipole moment of the electron. We show computationally that perovskite-structure europium barium titanate should exhibit the required large and pressure-dependent ferroelectric polarization, local magnetic moments, a…
▽ More
We describe the first-principles design and subsequent synthesis of a new material with the specific functionalities required for a solid-state-based search for the permanent electric dipole moment of the electron. We show computationally that perovskite-structure europium barium titanate should exhibit the required large and pressure-dependent ferroelectric polarization, local magnetic moments, and absence of magnetic ordering even at liquid helium temperature. Subsequent synthesis and characterization of Eu$_{0.5}$Ba$_{0.5}$TiO$_3$ ceramics confirm the predicted desirable properties.
△ Less
Submitted 18 June, 2010; v1 submitted 1 February, 2010;
originally announced February 2010.
-
Comment on "Rovibrational quantum interferometers and gravitational waves"
Authors:
I. B. Khriplovich,
S. K. Lamoreaux,
A. O. Sushkov,
O. P. Sushkov
Abstract:
In a recent paper, Wicht, Lämmerzahl, Lorek, and Dittus [Phys. Rev. {\bf A 78}, 013610 (2008)] come to the conclusion that a molecular rotational-vibrational quantum interferometer may possess the sensitivity necessary to detect gravitational waves. We do not agree with their results and demonstrate here that the true sensitivity of such interferometer is many orders of magnitude worse than that…
▽ More
In a recent paper, Wicht, Lämmerzahl, Lorek, and Dittus [Phys. Rev. {\bf A 78}, 013610 (2008)] come to the conclusion that a molecular rotational-vibrational quantum interferometer may possess the sensitivity necessary to detect gravitational waves. We do not agree with their results and demonstrate here that the true sensitivity of such interferometer is many orders of magnitude worse than that claimed in the mentioned paper. In the present comment we estimate the expected energy shifts and derive equations of motion for a quantum symmetric top (diatomic molecule or deformed nucleus) in the field of gravitational wave, and then estimate the sensitivity of possible experiments.
△ Less
Submitted 3 November, 2009;
originally announced November 2009.
-
The prospects for an electron electric dipole moment search with ferroelectric (Eu,Ba)TiO$_3$ ceramics
Authors:
A. O. Sushkov,
S. Eckel,
S. K. Lamoreaux
Abstract:
We propose to use ferroelectric (Eu,Ba)TiO$_3$ ceramics just above their magnetic ordering temperature for a sensitive electron electric dipole moment search. We have synthesized a number of such ceramics with various Eu concentrations and measured their properties relevant for such a search: permeability, magnetization noise, and ferroelectric hysteresis loops. The results of our measurements i…
▽ More
We propose to use ferroelectric (Eu,Ba)TiO$_3$ ceramics just above their magnetic ordering temperature for a sensitive electron electric dipole moment search. We have synthesized a number of such ceramics with various Eu concentrations and measured their properties relevant for such a search: permeability, magnetization noise, and ferroelectric hysteresis loops. The results of our measurements indicate that a search for the electron electric dipole moment with Eu$_{0.5}$Ba$_{0.5}$TiO$_3$ should lead to an order of magnitude improvement on the current best limit.
△ Less
Submitted 27 October, 2009;
originally announced October 2009.
-
Surface Contact Potential Patches and Casimir Force Measurements
Authors:
Woo-Joong Kim,
A. O. Sushkov,
Diego A. R. Dalvit,
S. K. Lamoreaux
Abstract:
We present calculations of contact potential surface patch effects that simplify previous treatments. It is shown that, because of the linearity of Laplace's equation, the presence of patch potentials does not affect an electrostatic calibration (of force and/or distance) of a two-plate Casimir measurement apparatus. Using models that include long-range variations in the contact potential across…
▽ More
We present calculations of contact potential surface patch effects that simplify previous treatments. It is shown that, because of the linearity of Laplace's equation, the presence of patch potentials does not affect an electrostatic calibration (of force and/or distance) of a two-plate Casimir measurement apparatus. Using models that include long-range variations in the contact potential across the plate surfaces, a number of experimental observations can be reproduced and explained. For these models, numerical calculations show that if a voltage is applied between the plates which minimizes the force, a residual electrostatic force persists, and that the minimizing potential varies with distance. The residual force can be described by a fit to a simple two-parameter function involving the minimizing potential and its variation with distance. We show the origin of this residual force by use of a simple parallel capacitor model. Finally, the implications of a residual force that varies in a manner different from 1/d on the accuracy of previous Casimir measurements is discussed.
△ Less
Submitted 6 January, 2010; v1 submitted 20 May, 2009;
originally announced May 2009.
-
Measuring the Neutron Lifetime Using Magnetically Trapped Neutrons
Authors:
C. M. O'Shaughnessy,
R. Golub,
K. W. Schelhammer,
C. M. Swank,
P. -N. Seo,
P. R. Huffman,
S. N. Dzhosyuk,
C. E. H. Mattoni,
L. Yang,
J. M. Doyle,
K. J. Coakley,
A. K. Thompson,
H. P. Mumm,
S. K. Lamoreaux,
G. Yang
Abstract:
The neutron beta-decay lifetime plays an important role both in understanding weak interactions within the framework of the Standard Model and in theoretical predictions of the primordial abundance of 4He in Big Bang Nucleosynthesis. In previous work, we successfully demonstrated the trap** of ultracold neutrons (UCN) in a conservative potential magnetic trap. A major upgrade of the apparatus…
▽ More
The neutron beta-decay lifetime plays an important role both in understanding weak interactions within the framework of the Standard Model and in theoretical predictions of the primordial abundance of 4He in Big Bang Nucleosynthesis. In previous work, we successfully demonstrated the trap** of ultracold neutrons (UCN) in a conservative potential magnetic trap. A major upgrade of the apparatus is nearing completion at the National Institute of Standards and Technology Center for Neutron Research (NCNR). In our approach, a beam of 0.89 nm neutrons is incident on a superfluid 4He target within the minimum field region of an Ioffe-type magnetic trap. A fraction of the neutrons is downscattered in the helium to energies <200 neV, and those in the appropriate spin state become trapped. The inverse process is suppressed by the low phonon density of helium at temperatures less than 200 mK, allowing the neutron to travel undisturbed. When the neutron decays the energetic electron ionizes the helium, producing scintillation light that is detected using photomultiplier tubes. Statistical limitations of the previous apparatus will be alleviated by significant increases in field strength and trap volume resulting in twenty times more trapped neutrons.
△ Less
Submitted 31 March, 2009;
originally announced March 2009.
-
Measurement of the short-range attractive force between Ge plates using a torsion balance
Authors:
W. J. Kim,
A. O. Sushkov,
D. A. R. Dalvit,
S. K. Lamoreaux
Abstract:
We have measured the short-range attractive force between crystalline Ge plates, and found contributions from both the Casimir force and an electrical force possibly generated by surface patch potentials. Using a model of surface patch effects that generates an additional force due to a distance dependence of the apparent contact potential, the electrical force was parameterized using data at di…
▽ More
We have measured the short-range attractive force between crystalline Ge plates, and found contributions from both the Casimir force and an electrical force possibly generated by surface patch potentials. Using a model of surface patch effects that generates an additional force due to a distance dependence of the apparent contact potential, the electrical force was parameterized using data at distances where the Casimir force is relatively small. Extrapolating this model, to provide a correction to the measured force at distances less than 5 $μ$m, shows a residual force that is in agreement, within experimental uncertainty, with five models that have been used to calculate the Casimir force.
△ Less
Submitted 29 April, 2009; v1 submitted 15 December, 2008;
originally announced December 2008.
-
Reply to Comment [arXiv:0810.3244v1] by R.S. Decca et al. on "Contribution of drifting carriers to the Casimir-Lifshitz and Casimir-Polder interactions with semiconductor materials"
Authors:
Diego A. R. Dalvit,
Steve K. Lamoreaux
Abstract:
We show that the claims expressed in the Comment arXiv:0810.3244v1 by R.S. Decca et al against our paper, D.A.R. Dalvit and S.K. Lamoreaux, Phys. Rev. Lett. {\bf 101}, 163203 (2008), are wrong and manifestly inconsistent with basic principles of statistical physics.
We show that the claims expressed in the Comment arXiv:0810.3244v1 by R.S. Decca et al against our paper, D.A.R. Dalvit and S.K. Lamoreaux, Phys. Rev. Lett. {\bf 101}, 163203 (2008), are wrong and manifestly inconsistent with basic principles of statistical physics.
△ Less
Submitted 5 December, 2008; v1 submitted 4 December, 2008;
originally announced December 2008.
-
Computation of Casimir forces for dielectrics or intrinsic semiconductors based on the Boltzmann transport equation
Authors:
Diego A. R. Dalvit,
Steve K. Lamoreaux
Abstract:
The interaction between drifting carriers and traveling electromagnetic waves is considered within the context of the classical Boltzmann transport equation to compute the Casimir-Lifshitz force between media with small density of charge carriers, including dielectrics and intrinsic semiconductors. We expand upon our previous work [Phys. Rev. Lett. {\bf 101}, 163203 (2008)] and derive in some de…
▽ More
The interaction between drifting carriers and traveling electromagnetic waves is considered within the context of the classical Boltzmann transport equation to compute the Casimir-Lifshitz force between media with small density of charge carriers, including dielectrics and intrinsic semiconductors. We expand upon our previous work [Phys. Rev. Lett. {\bf 101}, 163203 (2008)] and derive in some detail the frequency-dependent reflection amplitudes in this theory and compute the corresponding Casimir free energy for a parallel plate configuration. We critically discuss the the issue of verification of the Nernst theorem of thermodynamics in Casimir physics, and explicity show that our theory satisfies that theorem. Finally, we show how the theory of drifting carriers connects to previous computations of Casimir forces using spatial dispersion for the material boundaries.
△ Less
Submitted 2 December, 2008;
originally announced December 2008.
-
Variation of the Fine-Structure Constant and Laser Cooling of Atomic Dysprosium
Authors:
N. A. Leefer,
A. Cingöz,
D. Budker,
S. J. Ferrell,
V. V. Yashchuk,
A. Lapierre,
A. -T Nguyen,
S. K. Lamoreaux,
J. R. Torgerson
Abstract:
Radio-frequency electric-dipole transitions between nearly degenerate, opposite parity levels of atomic dysprosium (Dy) were monitored over an eight-month period to search for a variation in the fine-structure constant, $α$. The data provide a rate of fractional temporal variation of $α$ of $(-2.4\pm2.3)\times10^{-15}$ yr$^{-1}$ or a value of $(-7.8 \pm 5.9) \times 10^{-6}$ for $k_α$, the variat…
▽ More
Radio-frequency electric-dipole transitions between nearly degenerate, opposite parity levels of atomic dysprosium (Dy) were monitored over an eight-month period to search for a variation in the fine-structure constant, $α$. The data provide a rate of fractional temporal variation of $α$ of $(-2.4\pm2.3)\times10^{-15}$ yr$^{-1}$ or a value of $(-7.8 \pm 5.9) \times 10^{-6}$ for $k_α$, the variation coefficient for $α$ in a changing gravitational potential. All results indicate the absence of significant variation at the present level of sensitivity. We also present initial results on laser cooling of an atomic beam of dysprosium.
△ Less
Submitted 1 December, 2008; v1 submitted 24 November, 2008;
originally announced November 2008.
-
Electric dipole moment searches: Effect of linear electric field frequency shifts induced in confined gases, II
Authors:
R. Golub,
C. M. Swank,
S. K. Lamoreaux
Abstract:
The next generation of particle edm searches will be at such a high sensitivity that it will be possible for the results to be contaminated by a systematic error resulting from the interaction of the motional (E x v/c) magnetic field with stray field gradients. In this paper we extend previous work to present an analytic form for the frequency shift in the case of a rectangular storage vessel an…
▽ More
The next generation of particle edm searches will be at such a high sensitivity that it will be possible for the results to be contaminated by a systematic error resulting from the interaction of the motional (E x v/c) magnetic field with stray field gradients. In this paper we extend previous work to present an analytic form for the frequency shift in the case of a rectangular storage vessel and discuss the implications of the result for the neutron edm experiment which will be installed at the SNS (Spallation Neutron Source) by the LANL collaboration
△ Less
Submitted 3 June, 2009; v1 submitted 29 October, 2008;
originally announced October 2008.
-
Magnetic susceptibility and magnetization fluctuation measurements of mixed Gadolinium-Yttrium Iron Garnets
Authors:
S. Eckel,
A. O. Sushkov,
S. K. Lamoreaux
Abstract:
We study the magnetic properties of Gadolinium-Yttrium Iron Garnet ($\text{Gd}_{x}\text{Y}_{3-x}\text{Fe}_5\text{0}_{12}$, $x=3,1.8$) ferrite ceramics. The complex initial permeability is measured in the temperature range 2 K to 295 K at frequency of 1 kHz, and in the frequency range 100 Hz to 200 MHz at temperatures 4 K, 77 K, and 295 K. The magnetic viscosity-induced imaginary part of the perm…
▽ More
We study the magnetic properties of Gadolinium-Yttrium Iron Garnet ($\text{Gd}_{x}\text{Y}_{3-x}\text{Fe}_5\text{0}_{12}$, $x=3,1.8$) ferrite ceramics. The complex initial permeability is measured in the temperature range 2 K to 295 K at frequency of 1 kHz, and in the frequency range 100 Hz to 200 MHz at temperatures 4 K, 77 K, and 295 K. The magnetic viscosity-induced imaginary part of the permeability is observed at low frequencies. Measurements of the magnetization noise are made at 4 K. Using the fluctuation-dissipation theorem, we find that the observed magnetization fluctuations are consistent with our measurements of the low-frequency imaginary part of permeability. We discuss some implications for proposed precision measurements as well as other possible applications.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
The prospects for a new search for the electron electric dipole moment in solid Gadolinium iron garnet ceramics
Authors:
A. O. Sushkov,
S. Eckel,
S. K. Lamoreaux
Abstract:
We address a number of issues regarding solid state electron electric dipole moment (EDM) experiments, focusing on gadolinium iron garnet (abbreviated GdIG, chemical formula Gd$_3$Fe$_5$O$_{12}$) as a possible sample material. GdIG maintains its high magnetic susceptibility down to 4.2 K, which enhances the EDM-induced magnetization of a sample placed in an electric field. We estimate that latti…
▽ More
We address a number of issues regarding solid state electron electric dipole moment (EDM) experiments, focusing on gadolinium iron garnet (abbreviated GdIG, chemical formula Gd$_3$Fe$_5$O$_{12}$) as a possible sample material. GdIG maintains its high magnetic susceptibility down to 4.2 K, which enhances the EDM-induced magnetization of a sample placed in an electric field. We estimate that lattice polarizability gives rise to an EDM enhancement factor of approximately 20. We also calculate the effect of the demagnetizing field for various sample geometries and permeabilities. Measurements of intrinsic GdIG magnetization noise are presented, and the fluctuation-dissipation theorem is used to compare our data with the measurements of the imaginary part of GdIG permeability at 4.2 K, showing good agreement above frequencies of a few hertz. We also observe how the demagnetizing field suppresses the noise-induced magnetic flux, confirming our calculations. The statistical sensitivity of an EDM search based on a solid GdIG sample is estimated to be on the same level as the present experimental limit. Such a measurement would be valuable, given the completely different methods and systematics involved. The most significant systematics in such an experiment are the magnetic hysteresis and the magneto-electric effect. Our analysis shows that it should be possible to control these at the level of statistical sensitivity.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
Electrostatic Background Forces due to Varying Contact Potentials in Casimir Experiments
Authors:
Steve K. Lamoreaux
Abstract:
The existence of a monotonic distance dependent contact potential between two plates in a Casimir experiment leads to an additional electrostatic force that is significantly different from the case of a constant potential. Such a varying potential can arise if there is a uniform gradient in the work function or contact potential across a plate, as opposed to random microscopic fluctuations assoc…
▽ More
The existence of a monotonic distance dependent contact potential between two plates in a Casimir experiment leads to an additional electrostatic force that is significantly different from the case of a constant potential. Such a varying potential can arise if there is a uniform gradient in the work function or contact potential across a plate, as opposed to random microscopic fluctuations associated with patch potentials. A procedure to compensate for this force is described for the case of an experiment where the electrostatic force is minimized at each measurement distance by applying a voltage between the plates. It is noted that the minimizing voltage is not the contact potential.
△ Less
Submitted 13 September, 2008; v1 submitted 6 August, 2008;
originally announced August 2008.
-
Quantum cryptography with polarization, phase and time encoding
Authors:
W. T. Buttler,
S. K. Lamoreaux
Abstract:
We develop and present a quantum cryptography concept in which phase determinations are made from the time that a photon is detected, as opposed to where the photon is detected, and hence is a non-interferometric process. The phase-encoded quantum information is contained in temporal and polarization superpositions of single photon states, forming a complex qudit of Hilbert dimension D equal to…
▽ More
We develop and present a quantum cryptography concept in which phase determinations are made from the time that a photon is detected, as opposed to where the photon is detected, and hence is a non-interferometric process. The phase-encoded quantum information is contained in temporal and polarization superpositions of single photon states, forming a complex qudit of Hilbert dimension D equal to or greater than 4. Based on this, we have developed a new quantum key distribution protocol that allows the generation of secret key in the presence of higher noise than is possible with other protocols.
△ Less
Submitted 5 August, 2008;
originally announced August 2008.
-
Contribution of drifting carriers to the Casimir-Lifshitz and Casimir-Polder interactions with semiconductor materials
Authors:
Diego A. R. Dalvit,
Steve K. Lamoreaux
Abstract:
We develop a new theory for Casimir-Lifshitz and Casimir-Polder interactions with semiconductor surfaces that takes into account charge drift in the bulk material. The corresponding frequency-dependent dispersion relations describe a crossover between Lifshitz results for dielectrics and for good conductors. In the quasi-static limit, our calculated reflection amplitudes coincide with those rece…
▽ More
We develop a new theory for Casimir-Lifshitz and Casimir-Polder interactions with semiconductor surfaces that takes into account charge drift in the bulk material. The corresponding frequency-dependent dispersion relations describe a crossover between Lifshitz results for dielectrics and for good conductors. In the quasi-static limit, our calculated reflection amplitudes coincide with those recently computed to account for Debye screening in the thermal Lifshitz force with conducting surfaces with small density of carriers.
△ Less
Submitted 16 July, 2008; v1 submitted 12 May, 2008;
originally announced May 2008.
-
Comment on ``Measurement of the $^3$He mass diffusion coefficient in superfluid $^4$He over the 0.45--0.95 K temperature range
Authors:
S. K. Lamoreaux,
R. Golub
Abstract:
The role of 3He-3He collisions in our diffusion experiment is addressed and shown to not be relevant to the measurement of 3He diffusion against phonons in superfluid helium.
The role of 3He-3He collisions in our diffusion experiment is addressed and shown to not be relevant to the measurement of 3He diffusion against phonons in superfluid helium.
△ Less
Submitted 9 April, 2008;
originally announced April 2008.
-
Possible resolution of the Casimir force finite temperature correction "controversies"
Authors:
Steve K. Lamoreaux
Abstract:
By considering the effect of diffusion on the external electric field response of charge carriers in metals and semiconductors, it is shown that the finite temperature correction proposed Bostrom and Sernelius requires substantial modification, and there is no large correction as suggested for good conductors. The apparent violation of the Third Law of Thermodynamics of the various proposed temp…
▽ More
By considering the effect of diffusion on the external electric field response of charge carriers in metals and semiconductors, it is shown that the finite temperature correction proposed Bostrom and Sernelius requires substantial modification, and there is no large correction as suggested for good conductors. The apparent violation of the Third Law of Thermodynamics of the various proposed temperature corrections to the Casimir force is also resolved. Finally, the effect of Debye screening on electrostatic calibrations between pure germanium surfaces is calculated
△ Less
Submitted 8 January, 2008;
originally announced January 2008.