Time- and energy-resolved effects in the boron-10 based Multi-Grid and helium-3 based thermal neutron detectors
Authors:
A. Backis,
A. Khaplanov,
R. Al Jebali,
R. Ammer,
I. Apostolidis,
J. Birch,
C. -C. Lai,
P. P. Deen,
M. Etxegarai,
N. de Ruette,
J. Freita Ramos,
D. F. Förster,
E. Haettner,
R. Hall-Wilton,
D. Hamilton,
C. Höglund,
P. M. Kadletz,
K. Kanaki,
E. Karnickis,
O. Kirstein,
S. Kolya,
Z. Kraujalyte,
A. Laloni,
K. Livingston,
O. Löhman
, et al. (11 additional authors not shown)
Abstract:
The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few $μ$eV, while comparing…
▽ More
The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few $μ$eV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ~ $μ$s short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of $μ$s wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.
△ Less
Submitted 14 January, 2021; v1 submitted 2 June, 2020;
originally announced June 2020.
-
Vanadium-based neutron Beam Monitor
Authors:
Vendula Maulerova,
Kalliopi Kanaki,
Peter Kadletz,
Robin Woracek,
Thomas Wilpert,
Kevin Fissum,
Alessio Laloni,
Nicholai Mauritzson,
Fatima Issa,
Richard Hall-Wilton
Abstract:
A prototype quasi-parasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard $^3$He proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund…
▽ More
A prototype quasi-parasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard $^3$He proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for Beam Monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beamlines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6-10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard $^3$He proportional counters, was investigated at the V17 and V20 neutron beamlines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the $^3$He proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron fluxes ranging from $10^3-10^{10}$ n/s/cm$^2$.
△ Less
Submitted 24 February, 2020;
originally announced February 2020.
-
Verification of He-3 proportional counters fast neutron sensitivity through a comparison with He-4 detectors
Authors:
Francesco Piscitelli,
Giacomo Mauri,
Alessio Laloni,
Richard Hall-Wilton
Abstract:
In the field of neutron scattering science, a large variety of instruments require detectors for thermal and cold neutrons. Helium-3 has been one of the main actors in thermal and cold neutron detection for many years. Nowadays neutron facilities around the world are pushing their technologies to increase the available flux delivered at the instruments, this enables a completely new science landsc…
▽ More
In the field of neutron scattering science, a large variety of instruments require detectors for thermal and cold neutrons. Helium-3 has been one of the main actors in thermal and cold neutron detection for many years. Nowadays neutron facilities around the world are pushing their technologies to increase the available flux delivered at the instruments, this enables a completely new science landscape. Complementary with the increasing available flux, a better signal-to-background ratio (S/B) enables to perform new types of measurements. To this aim, this manuscript re-examines the background sensitivity of today's "gold standard" neutron detection. Fast neutrons and gamma-rays are the main background species in neutron scattering experiments. The efficiency (sensitivity) of detecting fast neutrons, cosmic rays and gamma-rays, for a Helium-3-based detector is studied here through the comparison with Helium-4 counters. The comparison to Helium-4 allows to separate the thermal (and cold) neutron to the fast neutron contributions in Helium-3-based counters, which are otherwise entangled; verifying previous results from an indirect method. A relatively high sensitivity is found. Moreover, an estimate for the cosmic neutron fluence, also a source of background, at ground level at ESS is presented in this manuscript.
△ Less
Submitted 19 February, 2020;
originally announced February 2020.
-
The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer
Authors:
G. Mauri,
I. Apostolidis,
M. J. Christensen,
A. Glavic,
C. C. Lai,
A. Laloni,
F. Messi,
A. Lindh Olsson,
L. Robinson,
J. Stahn,
P. O. Svensson,
R. Hall-Wilton,
F. Piscitelli
Abstract:
The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been installed at the AMOR reflectometer at the Paul Scherrer Institut (PSI - Switzerland). The setup exploits the Selene guide concept and it can be considered a scale…
▽ More
The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been installed at the AMOR reflectometer at the Paul Scherrer Institut (PSI - Switzerland). The setup exploits the Selene guide concept and it can be considered a scaled-down demonstrator of Estia. The results of these tests are discussed. It will be shown how the characteristics of the Multi-Blade detector are features that allow the focusing reflectometry operation mode. Additionally the performance of the Multi-Blade, in terms of rate capability, exceeds current state-of-the-art technology. The improvements with respect to the previous prototypes are also highlighted; from background considerations to the linear and angular uniformity response of the detector.
△ Less
Submitted 9 January, 2020;
originally announced January 2020.