-
An elongated quantum dot as a distributed charge sensor
Authors:
S. M. Patomäki,
J. Williams,
F. Berritta,
C. Laine,
M. A. Fogarty,
R. C. C. Leon,
J. Jussot,
S. Kubicek,
A. Chatterjee,
B. Govoreanu,
F. Kuemmeth,
J. J. L. Morton,
M. F. Gonzalez-Zalba
Abstract:
Increasing the separation between semiconductor quantum dots offers scaling advantages by fa- cilitating gate routing and the integration of sensors and charge reservoirs. Elongated quantum dots have been utilized for this purpose in GaAs heterostructures to extend the range of spin-spin interactions. Here, we study a metal-oxide-semiconductor (MOS) device where two quantum dot arrays are separate…
▽ More
Increasing the separation between semiconductor quantum dots offers scaling advantages by fa- cilitating gate routing and the integration of sensors and charge reservoirs. Elongated quantum dots have been utilized for this purpose in GaAs heterostructures to extend the range of spin-spin interactions. Here, we study a metal-oxide-semiconductor (MOS) device where two quantum dot arrays are separated by an elongated quantum dot (340 nm long, 50 nm wide). We monitor charge transitions of the elongated quantum dot by measuring radiofrequency single-electron currents to a reservoir to which we connect a lumped-element resonator. We operate the dot as a single electron box to achieve charge sensing of remote quantum dots in each array, separated by a distance of 510 nm. Simultaneous charge detection on both ends of the elongated dot demonstrates that the charge is well distributed across its nominal length, supported by the simulated quantum-mechanical electron density. Our results illustrate how single-electron boxes can be realised with versatile foot- prints that may enable novel and compact quantum processor layouts, offering distributed charge sensing in addition to the possibility of mediated coupling.
△ Less
Submitted 4 January, 2023;
originally announced January 2023.
-
Fast high-fidelity single-shot readout of spins in silicon using a single-electron box
Authors:
G. A. Oakes,
V. N. Ciriano-Tejel,
D. Wise,
M. A. Fogarty,
T. Lundberg,
C. Lainé,
S. Schaal,
F. Martins,
D. J. Ibberson,
L. Hutin,
B. Bertrand,
N. Stelmashenko,
J. A. W. Robinson,
L. Ibberson,
A. Hashim,
I. Siddiqi,
A. Lee,
M. Vinet,
C. G. Smith,
J. J. L. Morton,
M. F. Gonzalez-Zalba
Abstract:
Three key metrics for readout systems in quantum processors are measurement speed, fidelity and footprint. Fast high-fidelity readout enables mid-circuit measurements, a necessary feature for many dynamic algorithms and quantum error correction, while a small footprint facilitates the design of scalable, highly-connected architectures with the associated increase in computing performance. Here, we…
▽ More
Three key metrics for readout systems in quantum processors are measurement speed, fidelity and footprint. Fast high-fidelity readout enables mid-circuit measurements, a necessary feature for many dynamic algorithms and quantum error correction, while a small footprint facilitates the design of scalable, highly-connected architectures with the associated increase in computing performance. Here, we present two complementary demonstrations of fast high-fidelity single-shot readout of spins in silicon quantum dots using a compact, dispersive charge sensor: a radio-frequency single-electron box. The sensor, despite requiring fewer electrodes than conventional detectors, performs at the state-of-the-art achieving spin read-out fidelity of 99.2% in less than 6 $μ$s. We demonstrate that low-loss high-impedance resonators, highly coupled to the sensing dot, in conjunction with Josephson parametric amplification are instrumental in achieving optimal performance. We quantify the benefit of Pauli spin blockade over spin-dependent tunneling to a reservoir, as the spin-to-charge conversion mechanism in these readout schemes. Our results place dispersive charge sensing at the forefront of readout methodologies for scalable semiconductor spin-based quantum processors.
△ Less
Submitted 13 March, 2022;
originally announced March 2022.
-
Quantifying and attenuating pathologic tremor in virtual reality
Authors:
Brian A. Cohn,
Dilan D. Shah,
Ali Marjaninejad,
Martin Shapiro,
Serhan Ulkumen,
Christopher M. Laine,
Francisco J. Valero-Cuevas,
Kenneth H. Hayashida,
Sarah Ingersoll
Abstract:
We present a virtual reality (VR) experience that creates a research-grade benchmark in assessing patients with active upper-limb tremor, while simultaneously offering the opportunity for patients to engage with VR experiences without their pathologic tremor. Accurate and precise use of handheld motion controllers in VR gaming applications may be limited for patients with upper limb tremor. In par…
▽ More
We present a virtual reality (VR) experience that creates a research-grade benchmark in assessing patients with active upper-limb tremor, while simultaneously offering the opportunity for patients to engage with VR experiences without their pathologic tremor. Accurate and precise use of handheld motion controllers in VR gaming applications may be limited for patients with upper limb tremor. In parallel, objective tools measuring tremor are not in widespread, routine clinical use. We used a commercially available VR system and designed a challenging virtual-balloon-pop** test mimicking a common nose-to-target pointing task used by medical practitioners to subjectively evaluate tremor in the exam room. Within our VR experience, we offer a software mode which uses a low-pass filter to adjust hand position and pointing orientation over a series of past data points. This digital filter creates a smoothing function for hand movement which effectively removes the patient's tremor in the VR representation. While the patient completes trials of the reaching task, quantitative data on the pathologic tremor is digitally recorded. With speed, accuracy, and the tremor components computed across three axes of movement, patients can be evaluated for their tremor amplitudes in a quantitative, replicable, and enjoyable manner. Removal of tremor in digital space may allow patients having significant upper limb tremor to have both an objective clinical measurement of symptoms while providing patients positive feedback and interaction.
△ Less
Submitted 16 September, 2018;
originally announced September 2018.
-
Physiological Tremor Increases when Skeletal Muscle is Shortened: Implications for Fusimotor Control
Authors:
Kian Jalaleddini,
Akira Nagamori,
Christopher M Laine,
Mahsa A. Golkar,
RObert E. Kearney,
Francisco J. Valero-Cuevas
Abstract:
The involuntary force fluctuations associated with physiological (as distinct from pathological) tremor are an unavoidable component of human motor control. While the origins of the physiological tremor are known to depend on muscle afferentation, it is possible that the mechanical properties of muscle-tendon systems also affect its generation, amplification and maintenance. In this paper, we inve…
▽ More
The involuntary force fluctuations associated with physiological (as distinct from pathological) tremor are an unavoidable component of human motor control. While the origins of the physiological tremor are known to depend on muscle afferentation, it is possible that the mechanical properties of muscle-tendon systems also affect its generation, amplification and maintenance. In this paper, we investigated the dependence of physiological tremor during tonic, isometric plantarflextion torque at 30% of maximum at three ankle angles. The amplitude of physiological tremor increased as calf muscles shortened in contrast to the stretch reflex whose amplitude decreases as muscle shortens. We used a closed-loop simulation model of afferented muscle to explore the mechanisms responsible for this behavior. We demonstrate that changing muscle lengths does not suffice to explain our experimental findings. Rather, the model consistently required the modulation of gamme-static fusimotor drive to produce increases in physiological tremor with muscle shortening--while successfully replicating the concomitant reduction in stretch reflex amplitude. This need to control gamma-static fusimotor drive explicitly as a function of muscle length has important implication. First, it permits the amplitudes of physiological tremor and stretch reflex to be decoupled. Second, it postulates neuromechanical interaction that require length-dependent gamma drive modulation to be independent from alpha drive to the parent muscle. Lastly, it suggests that physiological tremor can be used as a simple, non-invasive measure of the afferent mechanisms underlying healthy motor function, and their disruption in neurological conditions.
△ Less
Submitted 2 November, 2017;
originally announced November 2017.