-
Model-based T1, T2* and Proton Density Map** Using a Bayesian Approach with Parameter Estimation and Complementary Undersampling Patterns
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Purpose: To achieve automatic hyperparameter estimation for the joint recovery of quantitative MR images, we propose a Bayesian formulation of the reconstruction problem that incorporates the signal model. Additionally, we investigate the use of complementary undersampling patterns to determine optimal undersampling schemes for quantitative MRI.
Theory: We introduce a novel nonlinear approximate…
▽ More
Purpose: To achieve automatic hyperparameter estimation for the joint recovery of quantitative MR images, we propose a Bayesian formulation of the reconstruction problem that incorporates the signal model. Additionally, we investigate the use of complementary undersampling patterns to determine optimal undersampling schemes for quantitative MRI.
Theory: We introduce a novel nonlinear approximate message passing framework, referred to as ``AMP-PE'', that enables the simultaneous recovery of distribution parameters and quantitative maps.
Methods: We employed the variable flip angle multi-echo (VFA-ME) method to acquire measurements. Both retrospective and prospective undersampling approaches were utilized to obtain Fourier measurements using variable-density and Poisson-disk patterns. Furthermore, we extensively explored various undersampling schemes, incorporating complementary patterns across different flip angles and/or echo times.
Results: AMP-PE adopts a model-based joint recovery strategy, it outperforms the $l_1$-norm minimization approach that follows a decoupled recovery strategy. A comparison with an existing joint-recovery approach further demonstrates the advantageous outcomes of AMP-PE. For quantitative $T_1$ map** using VFA-ME, employing identical k-space sampling patterns across different echo times produced the best performance. Whereas for $T_2^*$ and proton density map**s, using complementary sampling patterns across different flip angles yielded the best performance.
Conclusion: AMP-PE is equipped with built-in parameter estimation, and works naturally in clinical settings with varying acquisition protocols and scanners. It also achieves improved performance by combining information from the MR signal model and the sparse prior on images.
△ Less
Submitted 10 September, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Robust Quantitative Susceptibility Map** via Approximate Message Passing with Parameter Estimation
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Purpose: For quantitative susceptibility map** (QSM), the lack of ground-truth in clinical settings makes it challenging to determine suitable parameters for the dipole inversion. We propose a probabilistic Bayesian approach for QSM with built-in parameter estimation, and incorporate the nonlinear formulation of the dipole inversion to achieve a robust recovery of the susceptibility maps.
Theo…
▽ More
Purpose: For quantitative susceptibility map** (QSM), the lack of ground-truth in clinical settings makes it challenging to determine suitable parameters for the dipole inversion. We propose a probabilistic Bayesian approach for QSM with built-in parameter estimation, and incorporate the nonlinear formulation of the dipole inversion to achieve a robust recovery of the susceptibility maps.
Theory: From a Bayesian perspective, the image wavelet coefficients are approximately sparse and modelled by the Laplace distribution. The measurement noise is modelled by a Gaussian-mixture distribution with two components, where the second component is used to model the noise outliers. Through probabilistic inference, the susceptibility map and distribution parameters can be jointly recovered using approximate message passing (AMP).
Methods: We compare our proposed AMP with built-in parameter estimation (AMP-PE) to the state-of-the-art L1-QSM, FANSI and MEDI approaches on the simulated and in vivo datasets, and perform experiments to explore the optimal settings of AMP-PE. Reproducible code is available at https://github.com/EmoryCN2L/QSM_AMP_PE
Results: On the simulated Sim2Snr1 dataset, AMP-PE achieved the lowest NRMSE, DFCM and the highest SSIM, while MEDI achieved the lowest HFEN. On the in vivo datasets, AMP-PE is robust and successfully recovers the susceptibility maps using the estimated parameters, whereas L1-QSM, FANSI and MEDI typically require additional visual fine-tuning to select or double-check working parameters.
Conclusion: AMP-PE provides automatic and adaptive parameter estimation for QSM and avoids the subjectivity from the visual fine-tuning step, making it an excellent choice for the clinical setting.
△ Less
Submitted 30 May, 2023; v1 submitted 29 July, 2022;
originally announced July 2022.
-
A Probabilistic Bayesian Approach to Recover $R_2^*$ map and Phase Images for Quantitative Susceptibility Map**
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Purpose: Undersampling is used to reduce the scan time for high-resolution 3D magnetic resonance imaging. In order to achieve better image quality and avoid manual parameter tuning, we propose a probabilistic Bayesian approach to recover $R_2^*$ map and phase images for quantitative susceptibility map** (QSM), while allowing automatic parameter estimation from undersampled data.
Theory: Sparse…
▽ More
Purpose: Undersampling is used to reduce the scan time for high-resolution 3D magnetic resonance imaging. In order to achieve better image quality and avoid manual parameter tuning, we propose a probabilistic Bayesian approach to recover $R_2^*$ map and phase images for quantitative susceptibility map** (QSM), while allowing automatic parameter estimation from undersampled data.
Theory: Sparse prior on the wavelet coefficients of images is interpreted from a Bayesian perspective as sparsity-promoting distribution. A novel nonlinear approximate message passing (AMP) framework that incorporates a mono-exponential decay model is proposed. The parameters are treated as unknown variables and jointly estimated with image wavelet coefficients.
Results: The proposed AMP with parameter estimation (AMP-PE) approach successfully recovers $R_2^*$ maps and phase images for QSM across various undersampling rates. It is more computationally efficient, and performs better than the state-of-the-art $l_1$-norm regularization (L1) approach in general, except a few cases where the L1 approach performs as well as AMP-PE.
Conclusion: AMP-PE achieves better performance by drawing information from both the sparse prior and the mono-exponential decay model. It does not require parameter tuning, and works with a clinical, prospective undersampling scheme where parameter tuning is often impossible or difficult due to the lack of ground-truth image.
△ Less
Submitted 9 July, 2022; v1 submitted 9 March, 2021;
originally announced March 2021.
-
Fast Nonconvex $T_2^*$ Map** Using ADMM
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Magnetic resonance (MR)-$T_2^*$ map** is widely used to study hemorrhage, calcification and iron deposition in various clinical applications, it provides a direct and precise map** of desired contrast in the tissue. However, the long acquisition time required by conventional 3D high-resolution $T_2^*$ map** method causes discomfort to patients and introduces motion artifacts to reconstructed…
▽ More
Magnetic resonance (MR)-$T_2^*$ map** is widely used to study hemorrhage, calcification and iron deposition in various clinical applications, it provides a direct and precise map** of desired contrast in the tissue. However, the long acquisition time required by conventional 3D high-resolution $T_2^*$ map** method causes discomfort to patients and introduces motion artifacts to reconstructed images, which limits its wider applicability. In this paper we address this issue by performing $T_2^*$ map** from undersampled data using compressive sensing (CS). We formulate the reconstruction as a nonconvex problem that can be decomposed into two subproblems. They can be solved either separately via the standard approach or jointly via the alternating direction method of multipliers (ADMM). Compared to previous CS-based approaches that only apply sparse regularization on the spin density $\boldsymbol X_0$ and the relaxation rate $\boldsymbol R_2^*$, our formulation enforces additional sparse priors on the $T_2^*$-weighted images at multiple echoes to improve the reconstruction performance. We performed convergence analysis of the proposed algorithm, evaluated its performance on in vivo data, and studied the effects of different sampling schemes. Experimental results showed that the proposed joint-recovery approach generally outperforms the state-of-the-art method, especially in the low-sampling rate regime, making it a preferred choice to perform fast 3D $T_2^*$ map** in practice. The framework adopted in this work can be easily extended to other problems arising from MR or other imaging modalities with non-linearly coupled variables.
△ Less
Submitted 4 August, 2020;
originally announced August 2020.