Skip to main content

Showing 1–4 of 4 results for author: Lagniel, J

.
  1. arXiv:physics/0008145  [pdf, ps

    physics.acc-ph

    Status Report on the 5 Mev Iphi RFQ

    Authors: R. Ferdinand, P-Y. Beauvais, R. Duperrier, A. France, J. Gaiffier, J-M. Lagniel, M. Painchault, F. Simoens, CEA-Saclay, DSM-DAPNIA-SEA, P. Balleyguier, CEA-Bruyeres le Chatel, DAM

    Abstract: A 5-MeV RFQ designed for a proton current up to 100-mA CW is now under construction as part of the High Intensity Proton Injector project (IPHI). Its computed transmission is greater than 99 %. The main goals of the project are to verify the accuracy of the design codes, to gain the know-how on fabrication, tuning procedures and operations, to measure the output beam characteristics in order to… ▽ More

    Submitted 18 August, 2000; originally announced August 2000.

    Comments: 3 pages, LINAC 2000

    Journal ref: eConf C000821 (2000) TUD04

  2. arXiv:physics/0008144  [pdf, ps

    physics.acc-ph

    Design of the Ess RFQs and Chop** Line

    Authors: R. Duperrier, R. Ferdinand, P. Gros, J-M. Lagniel, N. Pichoff, D. Uriot, CEA-Saclay, DSM-DAPNIA-SEA

    Abstract: The chop** line is a critical part of the ESS linac in term of technical realisation of the choppers and preservation of the beam qualities. A new optimised design of the ESS RFQs and chop** lines is reported. The beam dynamics has been optimised with H- beam currents up to 100-mA to have safety margin with respect to the ESS goals. The first RFQ transmits almost 99.7% of the beam up to 2 Me… ▽ More

    Submitted 18 August, 2000; originally announced August 2000.

    Comments: 3 pages, LINAC 2000, TUD03

    Journal ref: eConf C000821 (2000) TUD03

  3. arXiv:physics/0008143  [pdf, ps

    physics.acc-ph

    An ECR hydrogen negative ion source at CEA/Saclay: preliminary results

    Authors: R. Gobin, P-Y. Beauvais, O. Delferriere, R. Ferdinand, F. Harrault, J-M. Lagniel

    Abstract: The development of a high intensity negative ion source is part of a considerably larger activity presently undergoing at CEA Saclay in the field of high intensity linear accelerators. Preliminary studies toward the construction of a 2.45 GHz ECR H- ion source have been performed for few months. This new test bench takes advantage of our experience on the French high intensity proton source SILH… ▽ More

    Submitted 18 August, 2000; originally announced August 2000.

    Comments: 3 pages, 3 figures, LINAC 2000 MOD07

    Journal ref: eConf C000821 (2000) MOD07

  4. arXiv:physics/0008121  [pdf, ps

    physics.acc-ph

    Toutatis, the Cea-Saclay RFQ code

    Authors: R. Duperrier, R. Ferdinand, J. -M. Lagniel, N. Pichoff

    Abstract: A CW high power linear accelerator can only work with very low particles losses and structure activation. At low energy, the RFQ is a very sensitive element to losses. To design the RFQ, a good understanding of the beam dynamics is requested. Generally, the reference code PARMTEQM is enough to design the accelerator. TOUTATIS has been written with goals of cross-checking results and obtaining a… ▽ More

    Submitted 17 August, 2000; originally announced August 2000.

    Comments: 3 pages, 6 figures, LINAC 2000

    Journal ref: eConf C000821 (2000) THB19