Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter
Authors:
I. Laktineh,
B. Liu,
D. Boumediene,
Y. W. Baek,
D-W. Kim,
S. C. Lee,
B. G. Min,
S. W. Park,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh,
B. Liu,
B. Li,
N. Lumb
, et al. (53 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm $\times$ 1~cm pickup pads combined to a multi-threshold electronics. The prototype was exposed to hadron beams in both the CERN PS and the SPS beamlines in 2015 allowing the test of the SDHCAL in a large energy range from 3~GeV to 80~GeV. After introducing the method used to select the hadrons of our data and reject the muon and electron contamination, we present the energy reconstruction approach that we apply to the data collected from both beamlines and we discuss the response linearity and the energy resolution of the SDHCAL. The results obtained in the two beamlines confirm the excellent SDHCAL performance observed with the data collected with the same prototype in the SPS beamline in 2012. They also show the stability of the SDHCAL in different beam conditions and different time periods.
△ Less
Submitted 19 February, 2022;
originally announced February 2022.
-
Performance study of large-area glass resistive plate chambers with different spacer configurations
Authors:
L. Mao,
F. Lagarde,
J. Guo,
X. Wang,
J. Li,
Q. Shen,
J. Zhu,
H. Yang
Abstract:
Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized spacer configuration (76 spacers) decreases the number of spacers by $24\%$ compared to the original design (100 spacers), thus helps significantly reduce the no…
▽ More
Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized spacer configuration (76 spacers) decreases the number of spacers by $24\%$ compared to the original design (100 spacers), thus helps significantly reduce the non-active or low-efficiency area caused by spacers while maintaining similar deformation uniformity of the electrodes. Large area glass RPCs with 1x1 m$^2$ size using two types of spacer configurations are constructed and tested with cosmic muons events. The muon detection efficiencies for RPCs are greater than $95\%$.
△ Less
Submitted 26 November, 2021; v1 submitted 29 August, 2021;
originally announced August 2021.
-
Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype
Authors:
D. Boumediene,
A. **ault,
M. Tytgat,
B. Bilki,
D. Northacker,
Y. Onel,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
R. Ete G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh
, et al. (65 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
High Rate RPC detector for LHC
Authors:
F. Lagarde,
A. Fagot,
M. Gul,
C. Roskas,
M. Tytgat,
N. Zaganidis,
S. Fonseca De Souza,
A. Santoro,
F. Torres Da Silva De Araujo,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
D. Han,
W. Yi,
C. Avila,
A. Cabrera
, et al. (77 additional authors not shown)
Abstract:
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The…
▽ More
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.
△ Less
Submitted 16 July, 2018;
originally announced July 2018.
-
R&D towards the CMS RPC Phase-2 upgrade
Authors:
A. Fagot,
A. Cimmino,
S. Crucy,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Aly,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
V. Bhatnagar
, et al. (71 additional authors not shown)
Abstract:
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle…
▽ More
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.
△ Less
Submitted 14 June, 2016;
originally announced June 2016.
-
High rate, fast timing Glass RPC for the high η CMS muon detectors
Authors:
F. Lagarde,
M. Gouzevitch,
I. Laktineh,
V. Buridon,
X. Chen,
C. Combaret,
A. Eynard,
L. Germani,
G. Grenier,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
W. Tromeuraa,
Y. Wang,
A. Gongab,
N. Moreau,
C. de la Taille,
F. Dulucqac,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat
, et al. (86 additional authors not shown)
Abstract:
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expec…
▽ More
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high $η$ muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.
△ Less
Submitted 22 July, 2016; v1 submitted 4 June, 2016;
originally announced June 2016.
-
High rate, fast timing Glass RPC for the high $η$ CMS muon detectors
Authors:
Maxime Gouzevitch,
François Lagarde,
Imad Laktineh,
Victor Buridon,
Xiushan Chen,
Christophe Combaret,
Alexis Eynard,
Lionel Germani,
Gerald Grenier,
Hervé Mathez,
Laurent Mirabito,
Alexei Petrukhin,
Arnaud Steen,
William Tromeur,
Yi Wang,
Fuyue Wang,
Nathalie Moreau,
Christophe de la Taille,
Fréderic Dulucq
Abstract:
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6 \cdot 10^{34}$ cm$^{-2}$s$^{-1}$. The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of t…
▽ More
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6 \cdot 10^{34}$ cm$^{-2}$s$^{-1}$. The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz/cm$^2$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. A new generation Glass-RPC (GRPC) using low resistivity glass (LR) is proposed to equip at least the two most far away of the four high eta muon stations of CMS. The design of small size prototypes and the studies of their performances under high rate particles flux is presented.
△ Less
Submitted 3 June, 2016;
originally announced June 2016.
-
Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment
Authors:
M. Shopova,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
G. Sultanov,
M. Rodozov,
S. Stoykova,
Y. Assran,
A. Sayed,
A. Radi,
S. Aly,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
A. Cimmino
, et al. (71 additional authors not shown)
Abstract:
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the L…
▽ More
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.
△ Less
Submitted 22 May, 2016;
originally announced May 2016.
-
Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope
Authors:
K. S. Lee,
S. Choi,
B. S. Hong,
M. Jo,
J. W. Kang,
M. Kang,
H. Kim,
K. Lee,
S. K. Parka,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Ali,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese
, et al. (71 additional authors not shown)
Abstract:
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muon…
▽ More
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muons provided by the SPS H4 beam line at CERN. We applied maximum gamma rates of 1.5 kHz cm-2 provided by 137Cs sources at Korea University and the GIF++ irradiation facility installed at the SPS H4 beam line to examine the rate capabilities of the prototype RPCs. In contrast to the case of the four-gap RPCs, we found the relatively high threshold was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits with high voltage, especially when measuring the narrow-pitch strips. The gamma-induced currents drawn in the four-gap RPC were about one-fourth of those drawn in the double-gap RPC. The rate capabilities of both RPC types, proven through the present testing using gamma-ray sources, far exceeded the maximum rate expected in the new high-η endcap RPCs planned for future phase-II LHC runs.
△ Less
Submitted 4 May, 2016; v1 submitted 2 May, 2016;
originally announced May 2016.