ArDM: a ton-scale LAr detector for direct Dark Matter searches
Authors:
ArDM Collaboration,
A. Marchionni,
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
J. Coleman,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
K. Mavrokoridis,
A. Melgarejo
, et al. (19 additional authors not shown)
Abstract:
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduc…
▽ More
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduce the detection threshold. Direct detection of the ionization charge with fine spatial granularity, combined with a measurement of the amplitude and time evolution of the associated primary scintillation light, provide powerful tools for the identification of WIMP interactions against the background due to electrons, photons and possibly neutrons if scattering more than once. A one ton LAr detector is presently installed on surface at CERN to fully test all functionalities and it will be soon moved to an underground location. We will emphasize here the lessons learned from such a device for the design of a large LAr TPC for neutrino oscillation, proton decay and astrophysical neutrinos searches.
△ Less
Submitted 29 December, 2010;
originally announced December 2010.
-
Test of a Liquid Argon TPC in a magnetic field and investigation of high temperature superconductors in liquid argon and nitrogen
Authors:
A. Badertscher,
L. Knecht,
M. Laffranchi,
G. Natterer,
A. Rubbia,
Th. Strauss
Abstract:
Tests with cosmic ray muons of a small liquid argon time projection chamber (LAr TPC) in a magnetic field of 0.55 T are described. No effect of the magnetic field on the imaging properties were observed. In view of a future large, magnetized LAr TPC, we investigated the possibility to operate a high temperature superconducting (HTS) solenoid directly in the LAr of the detector. The critical curren…
▽ More
Tests with cosmic ray muons of a small liquid argon time projection chamber (LAr TPC) in a magnetic field of 0.55 T are described. No effect of the magnetic field on the imaging properties were observed. In view of a future large, magnetized LAr TPC, we investigated the possibility to operate a high temperature superconducting (HTS) solenoid directly in the LAr of the detector. The critical current $I_c$ of HTS cables in an external magnetic field was measured at liquid nitrogen and liquid argon temperatures and a small prototype HTS solenoid was built and tested.
△ Less
Submitted 27 October, 2010;
originally announced October 2010.
-
Feasibility of high-voltage systems for a very long drift in liquid argon TPCs
Authors:
S. Horikawa,
A. Badertscher,
L. Kaufmann,
M. Laffranchi,
A. Marchionni,
M. Messina,
G. Natterer,
A. Rubbia
Abstract:
Designs of high-voltage (HV) systems for creating a drift electric field in liquid argon TPCs are reviewed. In ongoing experiments systems capable of approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of up to 1.5 m. Two of them having different approaches are presented: (1) the ICARUS-T600 detector having a system consisting of an external power supply, HV feedthroughs and…
▽ More
Designs of high-voltage (HV) systems for creating a drift electric field in liquid argon TPCs are reviewed. In ongoing experiments systems capable of approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of up to 1.5 m. Two of them having different approaches are presented: (1) the ICARUS-T600 detector having a system consisting of an external power supply, HV feedthroughs and resistive voltage degraders and (2) the ArDM-1t detector having a cryogenic Greinacher HV multiplier inside the liquid argon volume. For a giant scale liquid argon TPC, a system providing 2 MV may be required to attain a drift length of approx. 20 m. Feasibility of such a system is evaluated by extrapolating the existing designs.
△ Less
Submitted 24 September, 2010;
originally announced September 2010.
-
First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches
Authors:
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
A. Marchionni,
K. Mavrokoridis,
A. Melgarejo,
P. Mijakowski,
G. Natterer
, et al. (16 additional authors not shown)
Abstract:
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM…
▽ More
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.
△ Less
Submitted 27 October, 2010; v1 submitted 19 September, 2010;
originally announced September 2010.
-
The ArDM experiment
Authors:
ArDM Collaboration,
C. Amsler,
A. Badertscher,
V. Boccone,
N. Bourgeois,
A. Bueno,
M. C. Carmona-Benitez,
M. Chorowski,
W. Creus,
A. Curioni,
E. Daw,
U. Degunda,
A. Dell'Antone,
M. Droge,
L. Epprecht,
C. Haller,
M. Haranczyk,
S. Horikawa,
L. Kaufmann,
J. Kisiel,
L. Knecht,
M. Laffranchi,
J. Lagoda,
C. Lazzaro,
P. Lightfoot
, et al. (29 additional authors not shown)
Abstract:
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, includin…
▽ More
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
△ Less
Submitted 28 June, 2010;
originally announced June 2010.
-
Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: comparison of single and double phase operation
Authors:
A. Badertscher,
L. Knecht,
M. Laffranchi,
D. Lussi,
A. Marchionni,
G. Natterer,
P. Otiougova,
F. Resnati,
A. Rubbia,
T. Viant
Abstract:
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM w…
▽ More
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM where the multiplication occurs. Moving charges induce a signal on the anode and on the LEM electrodes. The orthogonally segmented upper face of the upper LEM and anode permit the reconstruction of X-Y spatial coordinates of ionizing events. The detector is equipped with a Photo Multiplier Tube immersed in liquid for triggering the ionizing events and an argon purification circuit to ensure long drift paths. Cosmic muon tracks have been recorded and further characterization of the detector is ongoing. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.
△ Less
Submitted 16 July, 2009;
originally announced July 2009.
-
Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector
Authors:
The ArDM Collaboration,
V. Boccone,
P. K. Lightfoot,
K. Mavrokoridis,
C. Regenfus,
C. Amsler,
A. Badertscher,
A. Bueno,
H. Cabrera,
M. C. Carmona-Benitez,
M. Daniel,
E. J. Daw,
U. Degunda,
A. Dell'Antone,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
D. Lussi,
J. Lozano,
A. Marchionni,
A. Melgarejo
, et al. (16 additional authors not shown)
Abstract:
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were…
▽ More
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\small\texttrademark}-foil and diffuse Tetratex{\small\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650 nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\times 25$ cm$^2$ TTX sheets were coated and assembled in the detector. Measurements in argon gas are reported providing good evidence of fulfilling the light collection requirements of the experiment.
△ Less
Submitted 1 April, 2009;
originally announced April 2009.
-
Construction and operation of a Double Phase LAr Large Electron Multiplier Time Projection Chamber
Authors:
A. Badertscher,
L. Knecht,
M. Laffranchi,
A. Marchionni,
G. Natterer,
P. Otiougova,
F. Resnati,
A. Rubbia
Abstract:
We successfully operated a novel kind of LAr Time Projection Chamber based on a Large Electron Multiplier (LEM) readout system. The prototype, of about 3 liters active volume, is operated in liquid-vapour (double) phase pure Ar. The ionization electrons, after drifting in the LAr volume, are extracted by a set of grids into the gas phase and driven into the holes of a double stage LEM, where cha…
▽ More
We successfully operated a novel kind of LAr Time Projection Chamber based on a Large Electron Multiplier (LEM) readout system. The prototype, of about 3 liters active volume, is operated in liquid-vapour (double) phase pure Ar. The ionization electrons, after drifting in the LAr volume, are extracted by a set of grids into the gas phase and driven into the holes of a double stage LEM, where charge amplification occurs. Each LEM is a thick macroscopic hole multiplier of 10x10 cm$^2$ manufactured with standard PCB techniques. The electrons signal is readout via two orthogonal coordinates, one using the induced signal on the segmented upper electrode of the LEM itself and the other by collecting the electrons on a segmented anode. Custom-made preamplifiers have been especially developed for this purpose. Cosmic ray tracks have been successfully observed in pure gas at room temperature and in double phase Ar operation. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.
△ Less
Submitted 20 November, 2008;
originally announced November 2008.
-
Large underground, liquid based detectors for astro-particle physics in Europe: scientific case and prospects
Authors:
D. Autiero,
J. Aysto,
A. Badertscher,
L. Bezrukov,
J. Bouchez,
A. Bueno,
J. Busto,
J. -E. Campagne,
Ch. Cavata,
L. Chaussard,
A. de Bellefon,
Y. Declais,
J. Dumarchez,
J. Ebert,
T. Enqvist,
A. Ereditato,
F. von Feilitzsch,
P. Fileviez Perez,
M. Goger-Neff,
S. Gninenko,
W. Gruber,
C. Hagner,
M. Hess,
K. A. Hochmuth,
J. Kisiel
, et al. (46 additional authors not shown)
Abstract:
This document reports on a series of experimental and theoretical studies conducted to assess the astro-particle physics potential of three future large-scale particle detectors proposed in Europe as next generation underground observatories. The proposed apparatus employ three different and, to some extent, complementary detection techniques: GLACIER (liquid Argon TPC), LENA (liquid scintillato…
▽ More
This document reports on a series of experimental and theoretical studies conducted to assess the astro-particle physics potential of three future large-scale particle detectors proposed in Europe as next generation underground observatories. The proposed apparatus employ three different and, to some extent, complementary detection techniques: GLACIER (liquid Argon TPC), LENA (liquid scintillator) and MEMPHYS (\WC), based on the use of large mass of liquids as active detection media. The results of these studies are presented along with a critical discussion of the performance attainable by the three proposed approaches coupled to existing or planned underground laboratories, in relation to open and outstanding physics issues such as the search for matter instability, the detection of astrophysical- and geo-neutrinos and to the possible use of these detectors in future high-intensity neutrino beams.
△ Less
Submitted 29 May, 2007; v1 submitted 1 May, 2007;
originally announced May 2007.
-
The ArDM project: a Liquid Argon TPC for Dark Matter Detection
Authors:
M. Laffranchi,
A. Rubbia
Abstract:
WIMPs (Weakly Interacting Massive Particles) are considered the main candidates for Cold Dark Matter. The ArDM experiment aims at measuring signals directly induced by WIMPs in liquid argon. A 1-ton prototype is currently developed with the goal of demonstrating the feasibility and performance of a detector with such a large target mass. ArDM aims at acting as a liquid argon TPC and additionally…
▽ More
WIMPs (Weakly Interacting Massive Particles) are considered the main candidates for Cold Dark Matter. The ArDM experiment aims at measuring signals directly induced by WIMPs in liquid argon. A 1-ton prototype is currently developed with the goal of demonstrating the feasibility and performance of a detector with such a large target mass. ArDM aims at acting as a liquid argon TPC and additionally measuring the scintillation light. The principle of the experiment and the conceptual design of the detector are described.
△ Less
Submitted 7 February, 2007;
originally announced February 2007.
-
Nucleon Decay Searches with large Liquid Argon TPC Detectors at Shallow Depths: atmospheric neutrinos and cosmogenic backgrounds
Authors:
A. Bueno,
Z. Dai,
Y. Ge,
M. Laffranchi,
A. J. Melgarejo,
A. Meregaglia,
S. Navas,
A. Rubbia
Abstract:
Grand Unification of the strong, weak and electromagnetic interactions into a single unified gauge group is an extremely appealing idea which has been vigorously pursued theoretically and experimentally for many years. The detection of proton or bound-neutron decays would represent its most direct experimental evidence. In this context, we studied the physics potentialities of very large undergr…
▽ More
Grand Unification of the strong, weak and electromagnetic interactions into a single unified gauge group is an extremely appealing idea which has been vigorously pursued theoretically and experimentally for many years. The detection of proton or bound-neutron decays would represent its most direct experimental evidence. In this context, we studied the physics potentialities of very large underground Liquid Argon Time Projection Chambers (LAr TPC). We carried out a detailed simulation of signal efficiency and background sources, including atmospheric neutrinos and cosmogenic backgrounds. We point out that a liquid Argon TPC, offering good granularity and energy resolution, low particle detection threshold, and excellent background discrimination, should yield very good signal over background ratios in many possible decay modes, allowing to reach partial lifetime sensitivities in the range of $10^{34}-10^{35}$ years with exposures up to 1000 kton$\times$year, often in quasi-background-free conditions optimal for discoveries at the few events level, corresponding to atmospheric neutrino background rejections of the order of $10^5$. Multi-prong decay modes like e.g. $p\to μ^- π^+ K^+$ or $p\to e^+π^+π^-$ and channels involving kaons like e.g. $p\to K^+\barν$, $p\to e^+K^0$ and $p\to μ^+K^0$ are particularly suitable, since liquid Argon imaging (...)
△ Less
Submitted 13 January, 2007;
originally announced January 2007.
-
First results from a Liquid Argon Time Projection Chamber in a Magnetic Field
Authors:
A. Badertscher,
M. Laffranchi,
A. Meregaglia,
A. Mueller,
A. Rubbia
Abstract:
A small liquid argon Time Projection Chamber (LAr TPC) was operated for the first time in a magnetic field of 0.55 Tesla. The imaging properties of the detector were not affected by the magnetic field. In a test run with cosmic rays a sample of through going and stop** muons was collected. The chamber with the readout electronics and the experimental setup are described. A few selected events…
▽ More
A small liquid argon Time Projection Chamber (LAr TPC) was operated for the first time in a magnetic field of 0.55 Tesla. The imaging properties of the detector were not affected by the magnetic field. In a test run with cosmic rays a sample of through going and stop** muons was collected. The chamber with the readout electronics and the experimental setup are described. A few selected events were reconstructed and analyzed and the results are presented. The magnetic bending of the charged particle tracks allows the determination of the electric charge and the momentum, even for particles not fully contained in the drift chamber. These features are e.g. required for future neutrino detectors at a neutrino factory.
△ Less
Submitted 21 May, 2005;
originally announced May 2005.
-
Development of a novel high-sensivitiy LAr purity monitor based on an $α$-source
Authors:
A. Badertscher,
M. Laffranchi,
A. Rubbia
Abstract:
A novel liquid argon (LAr) purity monitor was developed with a sensitivity to electronegative impurities of the order of ppb (O$_2$ equivalent). Such a high purity is e.g. needed in a LAr drift chamber. The principle is to measure the lifetime of quasifree electrons in LAr, since this is the important parameter for the operation of a drift chamber. Free electrons are produced by ionizing the LAr…
▽ More
A novel liquid argon (LAr) purity monitor was developed with a sensitivity to electronegative impurities of the order of ppb (O$_2$ equivalent). Such a high purity is e.g. needed in a LAr drift chamber. The principle is to measure the lifetime of quasifree electrons in LAr, since this is the important parameter for the operation of a drift chamber. Free electrons are produced by ionizing the LAr with $α$-particles emitted by the $^{210}Po$ chain daughter of an isotope $^{210}Pb$ source. From a measurement of the charge of the electron cloud at the beginning and at the end of a drift path, together with the drift time, the lifetime of the electrons is obtained. The $α$-particles have a very short range of about 50 μ$m in LAr and the ionization density is very high, typically between $750÷1500\rm MeV/cm$, leading to a high recombination rate. To suppress the recombination of the argon ions with the electrons, the $α$-source was put in a strong electric field of $40÷150$ kV/cm. This was achieved by depositing the source on the surface of a spherical high voltage cathode with a diameter of about 0.5 mm. The anode was also made as a sphere of about the same diameter as the cathode, thus, close to the axis between the two electrodes the electric drift field was approximately a dipole field.
△ Less
Submitted 26 December, 2004;
originally announced December 2004.
-
First operation of a liquid Argon TPC embedded in a magnetic field
Authors:
A. Badertscher,
M. Laffranchi,
A. Meregaglia,
A. Rubbia
Abstract:
We have operated for the first time a liquid Argon TPC immersed in a magnetic field up to 0.55 T. We show that the imaging properties of the detector are not affected by the presence of the magnetic field. The magnetic bending of the ionizing particle allows to discriminate their charge and estimate their momentum. These figures were up to now not accessible in the non-magnetized liquid Argon TP…
▽ More
We have operated for the first time a liquid Argon TPC immersed in a magnetic field up to 0.55 T. We show that the imaging properties of the detector are not affected by the presence of the magnetic field. The magnetic bending of the ionizing particle allows to discriminate their charge and estimate their momentum. These figures were up to now not accessible in the non-magnetized liquid Argon TPC.
△ Less
Submitted 14 December, 2004;
originally announced December 2004.