-
Curved detectors for future X-ray astrophysics missions
Authors:
Eric D. Miller,
James A. Gregory,
Marshall W. Bautz,
Harry R. Clark,
Michael Cooper,
Kevan Donlon,
Richard F. Foster,
Catherine E. Grant,
Mallory Jensen,
Beverly LaMarr,
Renee Lambert,
Christopher Leitz,
Andrew Malonis,
Mo Neak,
Gregory Prigozhin,
Kevin Ryu,
Benjamin Schneider,
Keith Warner,
Douglas J. Young,
William W. Zhang
Abstract:
Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring a large area detector system that closely conforms to the curved focal surface. We have embarked on a project using a curved charge-coupled device (CCD) detect…
▽ More
Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring a large area detector system that closely conforms to the curved focal surface. We have embarked on a project using a curved charge-coupled device (CCD) detector technology developed at MIT Lincoln Laboratory to provide large-format, curved detectors for such missions, improving performance and simplifying design. We present the current status of this work, which aims to curve back-illuminated, large-format (5 cm x 4 cm) CCDs to 2.5-m radius and confirm X-ray performance. We detail the design of fixtures and the curving process, and present intial results on curving bare silicon samples and monitor devices and characterizing the surface geometric accuracy. The tests meet our accuracy requirement of <5 $μ$m RMS surface non-conformance for samples of similar thickness to the functional detectors. We finally show X-ray performance measurements of planar CCDs that will serve as a baseline to evaluate the curved detectors. The detectors exhibit low noise, good charge-transfer efficiency, and excellent, uniform spectroscopic performance, including in the important soft X-ray band.
△ Less
Submitted 26 June, 2024;
originally announced June 2024.
-
The high-speed X-ray camera on AXIS
Authors:
Eric D. Miller,
Marshall W. Bautz,
Catherine E. Grant,
Richard F. Foster,
Beverly LaMarr,
Andrew Malonis,
Gregory Prigozhin,
Benjamin Schneider,
Christopher Leitz,
Sven Herrmann,
Steven W. Allen,
Tanmoy Chattopadhyay,
Peter Orel,
R. Glenn Morris,
Haley Stueber,
Abraham D. Falcone,
Andrew Ptak,
Christopher Reynolds
Abstract:
AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying ab…
▽ More
AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying aboard missions such as Chandra and Suzaku, while retaining the low noise, excellent spectral performance, and low power requirements of those instruments. We present the design of the AXIS high-speed X-ray camera, which baselines large-format MIT Lincoln Laboratory CCDs employing low-noise pJFET output amplifiers and a single-layer polysilicon gate structure that allows fast, low-power clocking. These detectors are combined with an integrated high-speed, low-noise ASIC readout chip from Stanford University that provides better performance than conventional discrete solutions at a fraction of their power consumption and footprint. Our complementary front-end electronics concept employs state of the art digital video waveform capture and advanced signal processing to deliver low noise at high speed. We review the current performance of this technology, highlighting recent improvements on prototype devices that achieve excellent noise characteristics at the required readout rate. We present measurements of the CCD spectral response across the AXIS energy band, augmenting lab measurements with detector simulations that help us understand sources of charge loss and evaluate the quality of the CCD backside passivation technique. We show that our technology is on a path that will meet our requirements and enable AXIS to achieve world-class science.
△ Less
Submitted 1 September, 2023;
originally announced September 2023.
-
Demonstrating repetitive non-destructive readout (RNDR) with SiSeRO devices
Authors:
Tanmoy Chattopadhyay,
Sven Herrmann,
Peter Orel,
Kevan Donlon,
Gregory Prigozhin,
R. Glenn Morris,
Michael Cooper,
Beverly LaMarr,
Andrew Malonis,
Steven W. Allen,
Marshall W. Bautz,
Chris Leitz
Abstract:
We demonstrate so-called repetitive non-destructive readout (RNDR) for the first time on a Single electron Sensitive Readout (SiSeRO) device. SiSeRO is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors, developed at MIT Lincoln Laboratory. This technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor…
▽ More
We demonstrate so-called repetitive non-destructive readout (RNDR) for the first time on a Single electron Sensitive Readout (SiSeRO) device. SiSeRO is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors, developed at MIT Lincoln Laboratory. This technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. RNDR was realized by transferring the signal charge non-destructively between the internal gate and the summing well (SW), which is the last serial register. The advantage of the non-destructive charge transfer is that the signal charge for each pixel can be measured at the end of each transfer cycle and by averaging for a large number of measurements ($\mathrm{N_{cycle}}$), the total noise can be reduced by a factor of 1/$\mathrm{\sqrt{N_{cycle}}}$. In our experiments with a prototype SiSeRO device, we implemented nine ($\mathrm{N_{cycle}}$ = 9) RNDR cycles, achieving around 2 electron readout noise (equivalent noise charge or ENC) with spectral resolution close to the fano limit for silicon at 5.9 keV. These first results are extremely encouraging, demonstrating successful implementation of the RNDR technique in SiSeROs. They also lay foundation for future experiments with more optimized test stands (better temperature control, larger number of RNDR cycles, RNDR-optimized SiSeRO devices) which should be capable of achieving sub-electron noise sensitivities. This new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring very low-noise spectroscopic imagers. The sub-electron sensitivity also adds the capability to conduct in-situ absolute calibration, enabling unprecedented characterization of the low energy instrument response.
△ Less
Submitted 12 December, 2023; v1 submitted 3 May, 2023;
originally announced May 2023.
-
Understanding the effects of charge diffusion in next-generation soft X-ray imagers
Authors:
Eric D. Miller,
Gregory Y. Prigozhin,
Beverly J. LaMarr,
Marshall W. Bautz,
Richard F. Foster,
Catherine E. Grant,
Craig S. Lage,
Christopher Leitz,
Andrew Malonis
Abstract:
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and i…
▽ More
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and is potentially lost below the imposed noise threshold. In an effort to understand these subtle but significant effects and inform the design and requirements of future detectors, we present simulations of charge diffusion using a variety of detector characteristics and operational settings, assessing spectral response at a range of X-ray energies. We validate the simulations by comparing the performance to that of real CCD detectors tested in the lab and deployed in space, spanning a range of thickness, pixel size, and other characteristics. The simulations show that while larger pixels, higher bias voltage, and optimal backside passivation improve performance, reducing the readout noise has a dominant effect in all cases. We finally show how high-pixel-aspect-ratio devices present challenges for measuring the backside passivation performance due to the magnitude of other processes that degrade spectral response, and present a method for utilizing the simulations to qualitatively assess this performance. Since compelling science requirements often compete technically with each other (high spatial resolution, soft X-ray response, hard X-ray response), these results can be used to find the proper balance for a future high-spatial-resolution X-ray instrument.
△ Less
Submitted 15 August, 2022;
originally announced August 2022.
-
Single electron Sensitive Readout (SiSeRO) X-ray detectors: Technological progress and characterization
Authors:
Tanmoy Chattopadhyay,
Sven Herrmann,
Peter Orel,
R. G. Morris,
Daniel R. Wilkins,
Steven W. Allen,
Gregory Prigozhin,
Beverly LaMarr,
Andrew Malonis,
Richard Foster,
Marshall W. Bautz,
Kevan Donlon,
Michael Cooper,
Christopher Leitz
Abstract:
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have…
▽ More
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. Characterization was performed for a number of prototype sensors with different device architectures, e.g. location of the internal gate, MOSFET polysilicon gate structure, and location of the trough in the internal gate with respect to the source and drain of the MOSFET (the trough is introduced to confine the charge in the internal gate). Using a buried-channel SiSeRO, we have achieved a charge/current conversion gain of >700 pA per electron, an equivalent noise charge (ENC) of around 6 electrons root mean square (RMS), and a full width half maximum (FWHM) of approximately 140 eV at 5.9 keV at a readout speed of 625 Kpixel/s. In this paper, we discuss the SiSeRO working principle, the readout module developed at Stanford, and the characterization test results of the SiSeRO prototypes. We also discuss the potential to implement Repetitive Non-Destructive Readout (RNDR) with these devices and the preliminary results which can in principle yield sub-electron ENC performance. Additional measurements and detailed device simulations will be essential to mature the SiSeRO technology. However, this new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring fast, low-noise, radiation hard megapixel imagers with moderate spectroscopic resolution.
△ Less
Submitted 1 August, 2022;
originally announced August 2022.
-
Measurement and simulation of charge diffusion in a small-pixel charge-coupled device
Authors:
Beverly J. LaMarr,
Gregory Y. Prigozhin,
Eric D. Miller,
Carolyn Thayer,
Marshall W. Bautz,
Richard Foster,
Catherine E. Grant,
Andrew Malonis,
Barry E. Burke,
Michael Cooper,
Kevan Donlon,
Christopher Leitz
Abstract:
Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packe…
▽ More
Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packets. We investigate consequences for sensor performance, reporting charge diffusion measurements in a fully-depleted, 50um thick, back-illuminated CCD with 8um pixels. We are able to measure the size distributions of charge packets produced by 5.9 keV and 1.25 keV X-rays in this device. We find that individual charge packets exhibit a gaussian spatial distribution, and determine the frequency distribution of event widths for a range of internal electric field strength levels. We find a standard deviation for the largest charge packets, which occur near the entrance window, of 3.9um. We show that the shape of the event width distribution provides a clear indicator of full depletion and infer the relationship between event width and interaction depth. We compare measured width distributions to simulations. We compare traditional, 'sum-above-threshold' algorithms for event amplitude determination to 2D gaussian fitting of events and find better spectroscopic performance with the former for 5.9 keV events and comparable results at 1.25 keV. The reasons for this difference are discussed. We point out the importance of read noise driven detection thresholds in spectral resolution, and note that the derived read noise requirements for mission concepts such as AXIS and Lynx may be too lax to meet spectral resolution requirements. While we report measurements made with a CCD, we note that they have implications for the performance of high aspect-ratio silicon active pixel sensors as well.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
An Empirical Background Model for the NICER X-ray Timing Instrument
Authors:
Ronald A. Remillard,
Michael Loewenstein,
James F. Steiner,
Gregory Y. Prigozhin,
Beverly LaMarr,
Teruaki Enoto,
Keith C. Gendreau,
Zaven Arzoumanian,
Craig Markwardt,
Arkadip Basak,
Abigail L. Stevens,
Paul S. Ray,
Diego Altamirano,
Douglas J. K. Buisson
Abstract:
NICER has a comparatively low background rate, but it is highly variable, and its spectrum must be predicted using measurements unaffected by the science target. We describe an empirical, three-parameter model based on observations of seven pointing directions that are void of detectable sources. An examination of 3556 good time intervals (GTIs), averaging 570 s, yields a median rate (0.4-12 keV;…
▽ More
NICER has a comparatively low background rate, but it is highly variable, and its spectrum must be predicted using measurements unaffected by the science target. We describe an empirical, three-parameter model based on observations of seven pointing directions that are void of detectable sources. An examination of 3556 good time intervals (GTIs), averaging 570 s, yields a median rate (0.4-12 keV; 50 detectors) of 0.87 c/s, but in 5 percent (1 percent) of cases, the rate exceeds 10 (300) c/s. Model residuals persist at 20-30 percent of the initial rate for the brightest GTIs, implying one or more missing model parameters. Filtering criteria are given to flag GTIs likely to have unsatisfactory background predictions. With such filtering, we estimate a detection limit, 1.20 c/s (3 sigma, single GTI) at 0.4-12 keV, equivalent to 3.6e-12 erg/cm^2/s for a Crab-like spectrum. The corresponding limit for soft X-ray sources is 0.51 c/s at 0.3-2.0 keV, or 4.3e-13 erg/cm^2/s for a 100 eV blackbody. Faint-source filtering selects 85 percent of the background GTIs, and higher rates are expected for targets scheduled more favorably. An application of the model to 1 s timescale makes it possible to distinguish source flares from possible surges in the background.
△ Less
Submitted 20 May, 2021;
originally announced May 2021.
-
Broadband X-ray Burst Spectroscopy of the FRB-Emitting Galactic Magnetar
Authors:
G. Younes,
M. G. Baring,
C. Kouveliotou,
Z. Arzoumanian,
T. Enoto,
J. Doty,
K. C. Gendreau,
E. Göğüş,
S. Guillot,
T. Güver,
A. K. Harding,
W. C. G. Ho,
A. J. van der Horst,
G. K. Jaisawal,
Y. Kaneko,
B. J. LaMarr,
L. Lin,
W. Majid,
T. Okajima,
J. Pope,
P. S. Ray,
O. J. Roberts,
M. Saylor,
J. F. Steiner,
Z. Wadiasingh
Abstract:
Magnetars are young, magnetically-powered neutron stars possessing the strongest magnetic fields in the Universe. Fast Radio Bursts (FRBs) are extremely intense millisecond-long radio pulses of primarily extragalactic origin, and a leading attribution for their genesis focuses on magnetars. A hallmark signature of magnetars is their emission of bright, hard X-ray bursts of sub-second duration. On…
▽ More
Magnetars are young, magnetically-powered neutron stars possessing the strongest magnetic fields in the Universe. Fast Radio Bursts (FRBs) are extremely intense millisecond-long radio pulses of primarily extragalactic origin, and a leading attribution for their genesis focuses on magnetars. A hallmark signature of magnetars is their emission of bright, hard X-ray bursts of sub-second duration. On April 27th 2020, the Galactic magnetar SGR J1935+2154 emitted hundreds of X-ray bursts in a few hours. One of these temporally coincided with an FRB, the first detection of an FRB from the Milky Way. Here we present spectral and temporal analyses of 24 X-ray bursts emitted 13 hours prior to the FRB and seen simultaneously with the NASA NICER and Fermi/GBM missions in their combined energy range, 0.2 keV-30 MeV. These broadband spectra permit direct comparison with the spectrum of the FRB-associated X-ray burst (FRB-X). We demonstrate that all 24 NICER/GBM bursts are very similar temporally, albeit strikingly different spectrally, from FRB-X. The singularity of the FRB-X burst is perhaps indicative of an uncommon locale for its origin. We suggest that this event originated in quasi-polar open or closed magnetic field lines that extend to high altitudes.
△ Less
Submitted 7 January, 2021; v1 submitted 19 June, 2020;
originally announced June 2020.
-
NICER Detection of Strong Photospheric Expansion during a Thermonuclear X-Ray Burst from 4U 1820-30
Authors:
L. Keek,
Z. Arzoumanian,
D. Chakrabarty,
J. Chenevez,
K. C. Gendreau,
S. Guillot,
T. Güver,
J. Homan,
G. K. Jaisawal,
B. LaMarr,
F. K. Lamb,
S. Mahmoodifar,
C. B. Markwardt,
T. Okajima,
T. E. Strohmayer,
J. J. M. in 't Zand
Abstract:
The Neutron Star Interior Composition Explorer (NICER) on the International Space Station (ISS) observed strong photospheric expansion of the neutron star in 4U 1820-30 during a Type I X-ray burst. A thermonuclear helium flash in the star's envelope powered a burst that reached the Eddington limit. Radiation pressure pushed the photosphere out to ~200 km, while the blackbody temperature dropped to…
▽ More
The Neutron Star Interior Composition Explorer (NICER) on the International Space Station (ISS) observed strong photospheric expansion of the neutron star in 4U 1820-30 during a Type I X-ray burst. A thermonuclear helium flash in the star's envelope powered a burst that reached the Eddington limit. Radiation pressure pushed the photosphere out to ~200 km, while the blackbody temperature dropped to 0.45 keV. Previous observations of similar bursts were performed with instruments that are sensitive only above 3 keV, and the burst signal was weak at low temperatures. NICER's 0.2-12 keV passband enables the first complete detailed observation of strong expansion bursts. The strong expansion lasted only 0.6 s, and was followed by moderate expansion with a 20 km apparent radius, before the photosphere finally settled back down at 3 s after the burst onset. In addition to thermal emission from the neutron star, the NICER spectra reveal a second component that is well fit by optically thick Comptonization. During the strong expansion, this component is six times brighter than prior to the burst, and it accounts for 71% of the flux. In the moderate expansion phase, the Comptonization flux drops, while the thermal component brightens, and the total flux remains constant at the Eddington limit. We speculate that the thermal emission is reprocessed in the accretion environment to form the Comptonization component, and that changes in the covering fraction of the star explain the evolution of the relative contributions to the total flux.
△ Less
Submitted 20 August, 2018;
originally announced August 2018.
-
NICER and Fermi GBM Observations of the First Galactic Ultraluminous X-ray Pulsar Swift J0243.6+6124
Authors:
C. A. Wilson-Hodge,
C. Malacaria,
P. A. Jenke,
G. K. Jaisawal,
M. Kerr,
M. T. Wolff,
Z. Arzoumanian,
D. Chakrabarty,
J. P. Doty,
K. C. Gendreau,
S. Guillot,
W. C. G. Ho,
B. LaMarr,
C. B. Markwardt,
F. Ozel,
G. Y. Prigozhin,
P. S. Ray,
M. Ramos-Lerate,
R. A. Remillard,
T. E. Strohmayer,
M. L. Vezie,
K. S. Wood
Abstract:
Swift J0243.6+6124 is a newly discovered Galactic Be/X-ray binary, revealed in late September 2017 in a giant outburst with a peak luminosity of 2E+39 (d/7 kpc)^2 erg/s (0.1-10 keV), with no formerly reported activity. At this luminosity, Swift J0243.6+6124 is the first known galactic ultraluminous X-ray pulsar. We describe Neutron star Interior Composition Explorer (NICER)} and Fermi Gamma-ray Bu…
▽ More
Swift J0243.6+6124 is a newly discovered Galactic Be/X-ray binary, revealed in late September 2017 in a giant outburst with a peak luminosity of 2E+39 (d/7 kpc)^2 erg/s (0.1-10 keV), with no formerly reported activity. At this luminosity, Swift J0243.6+6124 is the first known galactic ultraluminous X-ray pulsar. We describe Neutron star Interior Composition Explorer (NICER)} and Fermi Gamma-ray Burst Monitor (GBM) timing and spectral analyses for this source. A new orbital ephemeris is obtained for the binary system using spin-frequencies measured with GBM and 15-50 keV fluxes measured with the Neil Gehrels Swift Observatory Burst Alert Telescope to model the system's intrinsic spin-up. Power spectra measured with NICER show considerable evolution with luminosity, including a quasi-periodic oscillation (QPO) near 50 mHz that is omnipresent at low luminosity and has an evolving central frequency. Pulse profiles measured over the combined 0.2-100 keV range show complex evolution that is both luminosity and energy dependent. Near the critical luminosity of L~1E+38 erg/s, the pulse profiles transition from single-peaked to double peaked, the pulsed fraction reaches a minimum in all energy bands, and the hardness ratios in both NICER and GBM show a turn-over to softening as the intensity increases. This behavior repeats as the outburst rises and fades, indicating two distinct accretion regimes. These two regimes are suggestive of the accretion structure on the neutron star surface transitioning from a Coulomb collisional stop** mechanism at lower luminosities to a radiation-dominated stop** mechanism at higher luminosities. This is the highest observed (to date) value of the critical luminosity, suggesting a magnetic field of B ~1E+13 G.
△ Less
Submitted 26 June, 2018;
originally announced June 2018.
-
A Persistent Disk Wind in GRS 1915+105 with NICER
Authors:
Joey Neilsen,
E. Cackett,
R. A. Remillard,
J. Homan,
J. F. Steiner,
K. Gendreau,
Z. Arzoumanian,
G. Prigozhin,
B. LaMarr,
J. Doty,
S. Eikenberry,
F. Tombesi,
R. Ludlam,
E. Kara,
D. Altamirano,
A. C. Fabian
Abstract:
The bright, erratic black hole X-ray binary GRS 1915+105 has long been a target for studies of disk instabilities, radio/infrared jets, and accretion disk winds, with implications that often apply to sources that do not exhibit its exotic X-ray variability. With the launch of NICER, we have a new opportunity to study the disk wind in GRS 1915+105 and its variability on short and long timescales. H…
▽ More
The bright, erratic black hole X-ray binary GRS 1915+105 has long been a target for studies of disk instabilities, radio/infrared jets, and accretion disk winds, with implications that often apply to sources that do not exhibit its exotic X-ray variability. With the launch of NICER, we have a new opportunity to study the disk wind in GRS 1915+105 and its variability on short and long timescales. Here we present our analysis of 39 NICER observations of GRS 1915+105 collected during five months of the mission data validation and verification phase, focusing on Fe XXV and Fe XXVI absorption. We report the detection of strong Fe XXVI in 32 (>80%) of these observations, with another four marginal detections; Fe XXV is less common, but both likely arise in the well-known disk wind. We explore how the properties of this wind depends on broad characteristics of the X-ray lightcurve: mean count rate, hardness ratio, and fractional RMS variability. The trends with count rate and RMS are consistent with an average wind column density that is fairly steady between observations but varies rapidly with the source on timescales of seconds. The line dependence on spectral hardness echoes known behavior of disk winds in outbursts of Galactic black holes; these results clearly indicate that NICER is a powerful tool for studying black hole winds.
△ Less
Submitted 6 June, 2018;
originally announced June 2018.
-
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor
Authors:
C. E. Grant,
B. LaMarr,
M. W. Bautz,
S. L. O'Dell
Abstract:
The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons scattering off the x-ray telescope's mirrors. The primary effect of this damage was to increase the charge-transfer inefficiency (CTI) of the ACIS 8 front-illuminat…
▽ More
The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons scattering off the x-ray telescope's mirrors. The primary effect of this damage was to increase the charge-transfer inefficiency (CTI) of the ACIS 8 front-illuminated CCDs. Subsequently, the Chandra team implemented procedures to remove the ACIS from the telescope's focus during high-radiation events: planned protection during radiation-belt transits; autonomous protection triggered by an on-board radiation monitor; and manual intervention based upon assessment of space-weather conditions. However, as Chandra's multilayer insulation ages, elevated temperatures have reduced the effectiveness of the on-board radiation monitor for autonomous protection. Here we investigate using the ACIS CCDs themselves as a radiation monitor. We explore the 10-year database to evaluate the CCDs' response to particle radiation and to compare this response with other radiation data and environment models.
△ Less
Submitted 23 July, 2010;
originally announced July 2010.
-
New CTI Correction Method for the Spaced-Row Charge Injection of the Suzaku X-Ray Imaging Spectrometer
Authors:
Hideki Uchiyama,
Midori Ozawa,
Hironori Matsumoto,
Takeshi Go Tsuru,
Katsuji Koyama,
Masashi Kimura,
Hiroyuki Uchida,
Hiroshi Nakajima,
Kiyoshi Hayashida,
Hiroshi Tsunemi,
Hideyuki Mori,
Aya Bamba,
Masanobu Ozaki,
Tadayasu Dotani,
Dai Takei,
Hiroshi Murakami,
Koji Mori,
Yoshitaka Ishisaki,
Takayoshi Kohmura,
Gregory Prigozhin,
Steve Kissel,
Eric Miller,
Beverly LaMarr,
Marshall Bautz
Abstract:
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the CTI, we have applied a spaced-row charge injection (SCI) technique to the XIS in orbit; by injecting charges into CCD rows periodically, the CTI is actively dec…
▽ More
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the CTI, we have applied a spaced-row charge injection (SCI) technique to the XIS in orbit; by injecting charges into CCD rows periodically, the CTI is actively decreased. The CTI in the SCI mode depends on the distance between a signal charge and a preceding injected row, and the pulse height shows periodic positional variations. Using in-flight data of onboard calibration sources and of the strong iron line from the Perseus cluster of galaxies, we studied the variation in detail. We developed a new method to correct the variation. By applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008 is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated CCD.
△ Less
Submitted 6 October, 2008;
originally announced October 2008.
-
Energy-Scale Calibration of the Suzaku X-Ray Imaging Spectrometer Using the Checker Flag Charge Injection Technique in Orbit
Authors:
Midori Ozawa,
Hideki Uchiyama,
Hironori Matsumoto,
Hiroshi Nakajima,
Katsuji Koyama,
Takeshi Go Tsuru,
Masahiro Uchino,
Hiroyuki Uchida,
Kiyoshi Hayashida,
Hiroshi Tsunemi,
Hideyuki Mori,
Aya Bamba,
Masanobu Ozaki,
Tadayasu Dotani,
Takayoshi Kohmura,
Yoshitaka Ishisaki,
Hiroshi Murakami,
Takeshi Kato,
Takeshi Kitazono,
Yuki Kimura,
Kazuki Ogawa,
Shunsuke Kawai,
Koji Mori,
Gregory Prigozhin,
Steve Kissel
, et al. (3 additional authors not shown)
Abstract:
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has superior performance such as a low background, high quantum efficiency, and good energy resolution in the 0.2-12 keV band. Because of the radiation damage in orbit, however, the charge transfer inefficiency (CTI) has increased, and hence the energy scale and resolution of the XIS has been de…
▽ More
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has superior performance such as a low background, high quantum efficiency, and good energy resolution in the 0.2-12 keV band. Because of the radiation damage in orbit, however, the charge transfer inefficiency (CTI) has increased, and hence the energy scale and resolution of the XIS has been degraded since the launch of July 2005. The CCD has a charge injection structure, and the CTI of each column and the pulse-height dependence of the CTI are precisely measured by a checker flag charge injection (CFCI) technique. Our precise CTI correction improved the energy resolution from 230 eV to 190 eV at 5.9 keV in December 2006. This paper reports the CTI measurements with the CFCI experiments in orbit. Using the CFCI results, we have implemented the time-dependent energy scale and resolution to the Suzaku calibration database.
△ Less
Submitted 22 September, 2008;
originally announced September 2008.
-
Physics of reverse annealing in high-resistivity Chandra ACIS CCDs
Authors:
C. E. Grant,
B. LaMarr,
G. Y. Prigozhin,
S. E. Kissel,
S. K. Brown,
M. W. Bautz
Abstract:
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane wa…
▽ More
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane was warmed from the operating temperature of -100C to +30C which unexpectedly further increased the CTI. We report results of ACIS CCD irradiation experiments in the lab aimed at better understanding this reverse annealing process. Six CCDs were irradiated cold by protons ranging in energy from 100 keV to 400 keV, and then subjected to simulated bakeouts in one of three annealing cycles. We present results of these lab experiments, compare them to our previous experiences on the ground and in flight, and derive limits on the annealing time constants.
△ Less
Submitted 10 July, 2008;
originally announced July 2008.
-
Performance of the Charge Injection Capability of Suzaku XIS
Authors:
H. Nakajima,
H. Yamaguchi,
H. Matsumoto,
T. G. Tsuru,
K. Koyama,
H. Tsunemi,
K. Hayashida,
K. Torii,
M. Namiki,
S. Katsuda,
M. Shoji,
D. Matsuura,
T. Miyauchi,
T. Dotani,
M. Ozaki,
H. Murakami,
M. W. Bautz,
S. E. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments…
▽ More
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments using a radiation damaged device, and in-orbit measurements of the XIS. The ground experiments show that charges are stably injected with the dispersion of 91eV in FWHM in a specific column for the charges equivalent to the X-ray energy of 5.1keV. This dispersion width is significantly smaller than that of the X-ray events of 113eV (FWHM) at approximately the same energy. The amount of charge loss during transfer in a specific column, which is measured with the charge injection capability, is consistent with that measured with the calibration source. These results indicate that the charge injection technique can accurately measure column-dependent charge losses rather than the calibration sources. The column-to-column CTI correction to the calibration source spectra significantly reduces the line widths compared to those with a column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at the time of one year after the launch). In addition, this method significantly reduces the low energy tail in the line profile of the calibration source spectrum.
△ Less
Submitted 12 May, 2007;
originally announced May 2007.
-
Temperature dependence of charge transfer inefficiency in Chandra X-ray CCDs
Authors:
C. E. Grant,
M. W. Bautz,
S. E. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magn…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on develo** techniques to mitigate CTI and spectral resolution degradation. We present the initial temperature dependence of ACIS CTI from -120 to -60 degrees Celsius and the current temperature dependence after more than six years of continuing slow radiation damage. We use the change of shape of the temperature dependence to speculate on the nature of the damaging particles.
△ Less
Submitted 7 June, 2006;
originally announced June 2006.
-
Long-term trends in radiation damage of Chandra X-ray CCDs
Authors:
C. E. Grant,
M. W. Bautz,
S. M. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. Current operations require ACIS to be protected during radiation belt passages to prevent this type of damage, but there remains a much slower and more gra…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. Current operations require ACIS to be protected during radiation belt passages to prevent this type of damage, but there remains a much slower and more gradual increase. We present the history of ACIS charge transfer inefficiency (CTI), and other measures of radiation damage, from January 2000 through June 2005. The rate of CTI increase is low, of order 1e-6 per year, with no indication of step-function increases due to specific solar events. Based on the time history and CCD location of the CTI increase, we speculate on the nature of the damaging particles.
△ Less
Submitted 1 September, 2005;
originally announced September 2005.
-
A charge transfer inefficiency correction model for the Chandra Advanced CCD Imaging Spectrometer
Authors:
C. E. Grant,
M. W. Bautz,
S. M. Kissel,
B. LaMarr
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magn…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on develo** techniques to mitigate CTI and spectral resolution degradation. We will discuss the characteristics of the damage, the detector and the particle background and how they conspire to degrade the instrument performance. We have developed a model for ACIS CTI which can be used to correct each event and regain some of the lost performance. The correction uses a map of the electron trap distribution, a parameterization of the energy dependent charge loss and the fraction of the lost charge re-emitted into the trailing pixel to correct the pixels in the event island. This model has been implemented in the standard Chandra data processing pipeline. Some of the correction algorithm was inspired by the earlier work on ACIS CTI correction by Townsley et al. (2000; 2002). The details of the CTI model and how each parameter improves performance will be discussed, as well as the limitations and the possibilities for future improvement.
△ Less
Submitted 9 July, 2004;
originally announced July 2004.
-
Sacrificial charge and the spectral resolution performance of the Chandra Advanced CCD Imaging Spectrometer
Authors:
Catherine E. Grant,
Gregory Y. Prigozhin,
Beverly LaMarr,
Mark W. Bautz
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on develo** techniques to mitigate charge transfer inefficiency (CTI)…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on develo** techniques to mitigate charge transfer inefficiency (CTI) and spectral resolution degradation. A post-facto CTI corrector has been developed which can effectively recover much of the lost resolution. Any further improvements in performance will require knowledge of the location and amount of sacrificial charge - charge deposited along the readout path of an event which fills electron traps and changes CTI. We report on efforts by the ACIS Instrument team to characterize which charge traps cause performance degradation and the properties of the sacrificial charge seen on-orbit. We also report on attempts to correct X-ray pulseheights for the presence of sacrificial charge.
△ Less
Submitted 6 September, 2002;
originally announced September 2002.
-
Analysis of On-Orbit ACIS Squeegee Mode Data on Chip I0
Authors:
Shanil N. Virani,
Paul P. Plucinsky,
Catherine E. Grant,
Beverly LaMarr
Abstract:
The MIT and CXC ACIS teams have explored a number of measures to ameliorate the effects of radiation damage suffered by the ACIS FI CCDs. One of these measures is a novel CCD read-out method called ``squeegee mode''. A variety of different implementations of the squeegee mode have now been tested on the I0 CCD.
Our results for the fitted FWHM at Al-K$α$ and Mn-K$α$ clearly demonstrate that all…
▽ More
The MIT and CXC ACIS teams have explored a number of measures to ameliorate the effects of radiation damage suffered by the ACIS FI CCDs. One of these measures is a novel CCD read-out method called ``squeegee mode''. A variety of different implementations of the squeegee mode have now been tested on the I0 CCD.
Our results for the fitted FWHM at Al-K$α$ and Mn-K$α$ clearly demonstrate that all the squeegee modes provide improved performance in terms of reducing CTI and improving spectral resolution. Our analysis of the detection efficiency shows that the so-called squeegee modes ``Vanilla'' and ``Maximum Observing Efficiency'' provide the same detection efficiency as the standard clocking, once the decay in the intensity of the radioactive source has been taken into account. The squeegee modes which utilize the slow parallel transfer (``Maximum Spectral Resolution'', ``Maximum Angular Resolution'', and ``Sub-Array'') show a significantly lower detection efficiency than the standard clocking. The slow parallel transfer squeegee modes exhibit severe grade migration from flight grade 0 to flight grade 64 and a smaller migration into ASCA g7. The latter effect can explain some of the drop in detection efficiency. (ABRIDGED ABSTRACT)
△ Less
Submitted 3 December, 2001;
originally announced December 2001.