A deep neural network for positioning and inter-crystal scatter identification in multiplexed PET detectors
Authors:
Francisco E Enriquez-Mier-y-Teran,
Lu** Zhou,
Steven R Meikle,
Andre Z Kyme
Abstract:
Objective: Conventional event positioning algorithms in light-sharing PET detectors are often limited by edge effects and the impact of inter-crystal scattering (ICS). This study explores the feasibility of deep neural network (DNN) techniques for more precise event positioning in finely segmented and highly multiplexed PET detectors with light-sharing. Approach: A DNN was designed for crystal loc…
▽ More
Objective: Conventional event positioning algorithms in light-sharing PET detectors are often limited by edge effects and the impact of inter-crystal scattering (ICS). This study explores the feasibility of deep neural network (DNN) techniques for more precise event positioning in finely segmented and highly multiplexed PET detectors with light-sharing. Approach: A DNN was designed for crystal localisation, and trained/tested with light distributions of photoelectric (P) and Compton/photoelectric (CP) events simulated using optical GATE and an efficient analytical method. Using the statistical properties of ICS events from simulation, an energy-guided positioning algorithm was built into the DNN, enabling selection of the unique or first crystal of interaction in P and CP events, respectively. Performance of the DNN was compared with Anger logic using light distributions from simulated 511-keV point sources near the PET detector. Results: Despite coarse photodetector data due to signal multiplexing, the DNN demonstrated a crystal classification accuracy of 90% for P events and 82% for CP events. For crystal positioning, the DNN outperformed Anger logic by at least 34% and 14% for P and CP events, respectively. Further improvement is somewhat constrained by the physics, specifically, the ratio of backward to forward scattering of gamma rays within the crystal array being close to 1. This prevents selecting the first crystal of interaction in CP events with a high degree of certainty. Significance: Light-sharing and multiplexed PET detectors are common in high-resolution PET, yet event positioning can be poor due to edge effects and ICS events. Our study shows that DNN-based event positioning can enhance 2D coincidence event positioning accuracy by nearly a factor of 2 compared to Anger logic. However, further improvements are difficult to foresee without timing information.
△ Less
Submitted 27 March, 2024;
originally announced March 2024.
-
Spatio-Temporal Correlation of Epileptic Seizures with The Electrocardiography Brain Perfusion Index
Authors:
Samuel J van Bohemen,
Joe O Nardo,
Jeffrey M Rogers,
Eleanor Stephens,
Chong H Wong,
Andrew F Bleasel,
Andre Z Kyme
Abstract:
The Electrocardiography Brain Perfusion index (EBPi) is a novel electrocardiography (ECG)-based metric that may function as a proxy for cerebral blood flow (CBF). We investigated the spatio-temporal correlation between EBPi and epileptic seizure events. EBPi was computed retrospectively from clinical EEG and ECG data captured previously from 30 epilepsy patients during seizures. Significant EBPi c…
▽ More
The Electrocardiography Brain Perfusion index (EBPi) is a novel electrocardiography (ECG)-based metric that may function as a proxy for cerebral blood flow (CBF). We investigated the spatio-temporal correlation between EBPi and epileptic seizure events. EBPi was computed retrospectively from clinical EEG and ECG data captured previously from 30 epilepsy patients during seizures. Significant EBPi changes were compared temporally with clinically defined ground-truth seizure onset and offset times. We also assessed the spatial correlation between EBPi metrics and clinically defined ground-truth seizure locations. A significant increase in EBPi was detected 10.5 s [-6, 53] (median [95% confidence interval (CI)]) after ground-truth seizure onset, and a significant decrease in EBPi was detected 5 s [-42, 74] (median [95% CI]) after ground-truth seizure offset. EBPi demonstrated a positive predictive value of 61.5% [33.3, 75] (median [95% CI]) and a sensitivity of 57.1% [38.5, 66.7] (median [95% CI]) for the detection of ground truth seizure locations. EBPi signals exhibited a temporal sensitivity to seizure events and in some cases were correlated spatially to the seizure location. Therefore, EBPi, which has been linked to CBF, appears to contain spatio-temporal information related to seizure activity and might have useful application in augmenting EEG data captured during seizures.
△ Less
Submitted 26 March, 2024;
originally announced March 2024.
-
Safety, feasibility, and acceptability of a novel device to monitor ischaemic stroke patients
Authors:
Samuel J van Bohemen,
Jeffrey M Rogers,
Aleksandra Alavanja,
Andrew Evans,
Noel Young,
Philip C Boughton,
Joaquin Valderrama,
Andre Z Kyme
Abstract:
This study assessed the safety, feasibility, and acceptability of a novel device to monitor ischaemic stroke patients. The device captured electroencephalography (EEG) and electrocardiography (ECG) data to compute an ECG-based metric termed the Electrocardiography Brain Perfusion index (EBPi), which may function as a proxy for cerebral blood flow (CBF). Seventeen ischaemic stroke patients wore the…
▽ More
This study assessed the safety, feasibility, and acceptability of a novel device to monitor ischaemic stroke patients. The device captured electroencephalography (EEG) and electrocardiography (ECG) data to compute an ECG-based metric termed the Electrocardiography Brain Perfusion index (EBPi), which may function as a proxy for cerebral blood flow (CBF). Seventeen ischaemic stroke patients wore the device for nine hours and reported feedback at 1, 3, 6 and 9 hours regarding user experience, comfort, and satisfaction (acceptability). Safety was assessed as the number of adverse events reported. Feasibility was assessed as the percentage of uninterrupted EEG/ECG data recorded (data capture efficiency). No adverse events were reported, only minor incidences of discomfort. Overall device comfort (92.5% +/- 10.3%) and data capture efficiency (95.8% +/- 6.8%) were very high with relatively low variance. The device did not restrict participants from receiving clinical care and rarely (n=6) restricted participants from undertaking routine tasks. This study provides a promising evidence base for the deployment of the device in a clinical setting. If clinically validated, EBPi may be able to detect CBF changes to monitor early neurological deterioration and treatment outcomes, thus filling an important gap in current monitoring options.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
Virtual Cylindrical PET for Efficient DOI Image Reconstruction with Sub-millimetre Resolution
Authors:
Francisco E Enríquez-Mier-y-Terán,
Andre Z Kyme,
Georgios Angelis,
Steven R Meikle
Abstract:
Objective: Image reconstruction in high resolution PET scanners with depth of interaction (DOI) capability is computationally challenging due to the high sampling in detector and image space. This study evaluates the use of a virtual cylinder to reduce the number of lines of response (LOR) for DOI-based reconstruction while maintaining uniform sub-millimetre spatial resolution. Approach: Virtual g…
▽ More
Objective: Image reconstruction in high resolution PET scanners with depth of interaction (DOI) capability is computationally challenging due to the high sampling in detector and image space. This study evaluates the use of a virtual cylinder to reduce the number of lines of response (LOR) for DOI-based reconstruction while maintaining uniform sub-millimetre spatial resolution. Approach: Virtual geometry was investigated using the awake animal mousePET as a test case. Using GATE, we simulated the physical scanner and three virtual cylinder implementations with detector size 0.7405 mm, 0.4712 mm and 0.3575 mm. The virtual cylinder condenses physical LORs stemming from various crystal pairs and DOI combinations, and which intersect a single virtual detector pair, into a single virtual LOR. Quantitative comparisons of the point spread function (PSF) at various positions within the field of view (FOV) were compared for reconstructions based on the vPET implementations and the physical scanner. We also assessed the impact of the anisotropic PSFs by reconstructing images of a micro Derenzo phantom. Main results: All virtual cylinder implementations achieved LOR data compression >50%. PSF anisotropy in radial/tangential profiles was chiefly influenced by DOI resolution. Spatial degradation introduced by virtual cylinders was most prominent axially. All virtual cylinders achieved sub-millimetre volumetric resolution across the FOV using 6-bin DOI reconstructions (3.3 mm DOI resolution). Using 0.4712 mm detectors with 6 DOI bins (LOR compression 86%) yielded nearly identical reconstructions to the non-virtual case. Significance: Our results show that DOI PET reconstruction with 50-86% LOR compression and sub-millimetre spatial resolution is possible using virtual cylinders. The methodology and analysis can be extended to high resolution scanners with DOI capability.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.