-
Drift-compensated Low-noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1
Authors:
Myoung-Sun Heo,
Sang Eon Park,
Won-Kyu Lee,
Sang-Bum Lee,
Hyun-Gue Hong,
Taeg Yong Kwon,
Chang Yong Park,
Dai-Hyuk Yu,
G. Santarelli,
Ashby Hilton,
Andre N. Luiten,
John G. Hartnett
Abstract:
In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency c…
▽ More
In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency comb locked to an ultra-stable laser, is better than $5\times10^{-15}$ at an averaging time of 1 s. We demonstrate that the short-term stability of the synthesizer is lower than the quantum projection noise limit of the Cs fountain clock, KRISS-F1(Cs) by measuring the short-term stability of the fountain with varying trapped atom number. The stability of the fountain at 1-s averaging time reaches $2.5\times10^{-14}$ at the highest atom number in the experiment when the synthesizer is used as an interrogation oscillator of the fountain. In order to compensate the frequency drift of the CSO, the output frequency of a waveform generator in the synthesis chain is ramped linearly. By doing this, the stability of the synthesizer at an average time of one hour reaches a level of $10^{-16}$ which is measured with the fountain clock.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Absolute frequency measurement of 1S0 (F = 1/2) - 3P0 (F = 1/2) transition of 171Yb atoms in a one-dimensional optical lattice at KRISS
Authors:
Chang Yong Park,
Dai-Hyuk Yu,
Won-Kyu Lee,
Sang Eon Park,
Eok Bong Kim,
Sun Kyung Lee,
Jun Woo Cho,
Tai Hyun Yoon,
Jongchul Mun,
Sung Jong Park,
Taeg Yong Kwon,
Sang-Bum Lee
Abstract:
We measured the absolute frequency of the optical clock transition 1S0 (F = 1/2) - 3P0 (F = 1/2) of 171Yb atoms confined in a one-dimensional optical lattice and it was determined to be 518 295 836 590 863.5(8.1) Hz. The frequency was measured against Terrestrial Time (TT; the SI second on the geoid) by using an optical frequency comb of which the frequency was phase-locked to an H-maser as a flyw…
▽ More
We measured the absolute frequency of the optical clock transition 1S0 (F = 1/2) - 3P0 (F = 1/2) of 171Yb atoms confined in a one-dimensional optical lattice and it was determined to be 518 295 836 590 863.5(8.1) Hz. The frequency was measured against Terrestrial Time (TT; the SI second on the geoid) by using an optical frequency comb of which the frequency was phase-locked to an H-maser as a flywheel oscillator traceable to TT. The magic wavelength was also measured as 394 798.48(79) GHz. The results are in good agreement with two previous measurements of other institutes within the specified uncertainty of this work.
△ Less
Submitted 25 January, 2013; v1 submitted 27 December, 2011;
originally announced December 2011.
-
Dynamical Response of Nanomechanical Resonators to Biomolecular Interactions
Authors:
Kilho Eom,
Tae Yun Kwon,
Dae Sung Yoon,
Hong Lim Lee,
Tae Song Kim
Abstract:
We studied the dynamical response of a nanomechanical resonator to biomolecular (e.g. DNA) adsorptions on a resonator's surface by using a theoretical model, which considers the Hamiltonian H such that the potential energy consists of elastic bending energy of a resonator and the potential energy for biomolecular interactions. It was shown that the resonant frequency shift of a resonator due to…
▽ More
We studied the dynamical response of a nanomechanical resonator to biomolecular (e.g. DNA) adsorptions on a resonator's surface by using a theoretical model, which considers the Hamiltonian H such that the potential energy consists of elastic bending energy of a resonator and the potential energy for biomolecular interactions. It was shown that the resonant frequency shift of a resonator due to biomolecular adsorption depends on not only the mass of adsorbed biomolecules but also the biomolecular interactions. Specifically, for dsDNA adsorption on a resonator's surface, the resonant frequency shift is also dependent on the ionic strength of a solvent, implying the role of molecular interactions on the dynamic behavior of a resonator. This indicates that nanomechanical resonators may enable one to quantify the biomolecular mass, implying the enumeration of biomolecules, as well as gain insight into intermolecular interactions between adsorbed biomolecules on the surface.
△ Less
Submitted 17 August, 2007; v1 submitted 25 June, 2007;
originally announced June 2007.