-
The 120Gbps VCSEL Array Based Optical Transmitter (ATx) Development for the High-Luminosity LHC (HL-LHC) Experiments
Authors:
Di Guo,
Chonghan Liu,
**ghong Chen,
John Chramowicz,
Binwei Deng,
Datao Gong,
Suen Hou,
Ge **,
Simon Kwan,
Futian Liang,
Xiaoting Li,
Gang Liu,
Tiankuan Liu,
Alan Prosser,
Da-Shung Su,
**-Kun Teng,
Tongye Xu,
**gbo Ye,
Xiandong Zhao,
Annie C. Xiang,
Hao Liang
Abstract:
The integration of a Verticle Cavity Surface-Emitting Laser (VCSEL) array and a driving Application-Specific Integrated Circuit (ASIC) in a custom optical array transmitter module (ATx) for operation in the detector front-end is constructed, assembled and tested. The ATx provides 12 parallel channels with each channel operating at 10 Gbps. The optical transmitter eye diagram passes the eye mask an…
▽ More
The integration of a Verticle Cavity Surface-Emitting Laser (VCSEL) array and a driving Application-Specific Integrated Circuit (ASIC) in a custom optical array transmitter module (ATx) for operation in the detector front-end is constructed, assembled and tested. The ATx provides 12 parallel channels with each channel operating at 10 Gbps. The optical transmitter eye diagram passes the eye mask and the bit-error rate (BER) less than 1E-12 transmission is achieved at 10 Gbps/ch. The overall insertion loss including the radiation induced attenuation is sufficiently low to meet the proposed link budget requirement.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.
-
NASA's Cold Atom Laboratory: Four Years of Quantum Science Operations in Space
Authors:
Kamal Oudrhiri,
James M. Kohel,
Nate Harvey,
James R. Kellogg,
David C. Aveline,
Roy L. Butler,
Javier Bosch-Lluis,
John L. Callas,
Leo Y. Cheng,
Arvid P. Croonquist,
Walker L. Dula,
Ethan R. Elliott,
Jose E. Fernandez,
Jorge Gonzales,
Raymond J. Higuera,
Shahram Javidnia,
Sandy M. Kwan,
Norman E. Lay,
Dennis K. Lee,
Irena Li,
Gregory J. Miles,
Michael T. Pauken,
Kelly L. Perry,
Leah E. Phillips,
Diane C. Malarik
, et al. (14 additional authors not shown)
Abstract:
The Cold Atom Laboratory (CAL) is a quantum facility for studying ultra-cold gases in the microgravity environment of the International Space Station. It enables research in a temperature regime and force-free environment inaccessible to terrestrial laboratories. In the microgravity environment, observation times over a few seconds and temperatures below 100 pK are achievable, unlocking the potent…
▽ More
The Cold Atom Laboratory (CAL) is a quantum facility for studying ultra-cold gases in the microgravity environment of the International Space Station. It enables research in a temperature regime and force-free environment inaccessible to terrestrial laboratories. In the microgravity environment, observation times over a few seconds and temperatures below 100 pK are achievable, unlocking the potential to observe new quantum phenomena. CAL launched to the International Space Station in May 2018 and has been operating since then as the world's first multi-user facility for studying ultra\-cold atoms in space. CAL is the first quantum science facility to produce the fifth state of matter called a Bose-Einstein condensate with rubidium-87 and potassium-41 in Earth orbit. We will give an overview of CAL's operational setup, outline its contributions to date, present planned upgrades for the next few years, and consider design choices for microgravity BEC successor-mission planning.
△ Less
Submitted 22 May, 2023;
originally announced May 2023.
-
The James Webb Space Telescope Mission
Authors:
Jonathan P. Gardner,
John C. Mather,
Randy Abbott,
James S. Abell,
Mark Abernathy,
Faith E. Abney,
John G. Abraham,
Roberto Abraham,
Yasin M. Abul-Huda,
Scott Acton,
Cynthia K. Adams,
Evan Adams,
David S. Adler,
Maarten Adriaensen,
Jonathan Albert Aguilar,
Mansoor Ahmed,
Nasif S. Ahmed,
Tanjira Ahmed,
Rüdeger Albat,
Loïc Albert,
Stacey Alberts,
David Aldridge,
Mary Marsha Allen,
Shaune S. Allen,
Martin Altenburg
, et al. (983 additional authors not shown)
Abstract:
Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least $4m$. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the $6.5m$ James Webb Space Telescope. A generation of astrono…
▽ More
Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least $4m$. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the $6.5m$ James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 years, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Evaluating the Factual Consistency of Large Language Models Through News Summarization
Authors:
Derek Tam,
Anisha Mascarenhas,
Shiyue Zhang,
Sarah Kwan,
Mohit Bansal,
Colin Raffel
Abstract:
While large language models (LLMs) have proven to be effective on a large variety of tasks, they are also known to hallucinate information. To measure whether an LLM prefers factually consistent continuations of its input, we propose a new benchmark called FIB(Factual Inconsistency Benchmark) that focuses on the task of summarization. Specifically, our benchmark involves comparing the scores an LL…
▽ More
While large language models (LLMs) have proven to be effective on a large variety of tasks, they are also known to hallucinate information. To measure whether an LLM prefers factually consistent continuations of its input, we propose a new benchmark called FIB(Factual Inconsistency Benchmark) that focuses on the task of summarization. Specifically, our benchmark involves comparing the scores an LLM assigns to a factually consistent versus a factually inconsistent summary for an input news article. For factually consistent summaries, we use human-written reference summaries that we manually verify as factually consistent. To generate summaries that are factually inconsistent, we generate summaries from a suite of summarization models that we have manually annotated as factually inconsistent. A model's factual consistency is then measured according to its accuracy, i.e.\ the proportion of documents where it assigns a higher score to the factually consistent summary. To validate the usefulness of FIB, we evaluate 23 large language models ranging from 1B to 176B parameters from six different model families including BLOOM and OPT. We find that existing LLMs generally assign a higher score to factually consistent summaries than to factually inconsistent summaries. However, if the factually inconsistent summaries occur verbatim in the document, then LLMs assign a higher score to these factually inconsistent summaries than factually consistent summaries. We validate design choices in our benchmark including the scoring method and source of distractor summaries. Our code and benchmark data can be found at https://github.com/r-three/fib.
△ Less
Submitted 2 December, 2023; v1 submitted 15 November, 2022;
originally announced November 2022.
-
TweetCOVID: A System for Analyzing Public Sentiments and Discussions about COVID-19 via Twitter Activities
Authors:
Jolin Shaynn-Ly Kwan,
Kwan Hui Lim
Abstract:
The COVID-19 pandemic has created widespread health and economical impacts, affecting millions around the world. To better understand these impacts, we present the TweetCOVID system that offers the capability to understand the public reactions to the COVID-19 pandemic in terms of their sentiments, emotions, topics of interest and controversial discussions, over a range of time periods and location…
▽ More
The COVID-19 pandemic has created widespread health and economical impacts, affecting millions around the world. To better understand these impacts, we present the TweetCOVID system that offers the capability to understand the public reactions to the COVID-19 pandemic in terms of their sentiments, emotions, topics of interest and controversial discussions, over a range of time periods and locations, using public tweets. We also present three example use cases that illustrates the usefulness of our proposed TweetCOVID system.
△ Less
Submitted 2 March, 2021;
originally announced March 2021.
-
Understanding Public Sentiments, Opinions and Topics about COVID-19 using Twitter
Authors:
Jolin Shaynn-Ly Kwan,
Kwan Hui Lim
Abstract:
The COVID-19 pandemic has caused widespread devastation throughout the world. In addition to the health and economical impacts, there is an enormous emotional toll associated with the constant stress of daily life with the numerous restrictions in place to combat the pandemic. To better understand the impact of COVID-19, we proposed a framework that utilizes public tweets to derive the sentiments,…
▽ More
The COVID-19 pandemic has caused widespread devastation throughout the world. In addition to the health and economical impacts, there is an enormous emotional toll associated with the constant stress of daily life with the numerous restrictions in place to combat the pandemic. To better understand the impact of COVID-19, we proposed a framework that utilizes public tweets to derive the sentiments, emotions and discussion topics of the general public in various regions and across multiple timeframes. Using this framework, we study and discuss various research questions relating to COVID-19, namely: (i) how sentiments/emotions change during the pandemic? (ii) how sentiments/emotions change in relation to global events? and (iii) what are the common topics discussed during the pandemic?
△ Less
Submitted 5 December, 2020;
originally announced December 2020.
-
An Optical and Infrared Time-Domain Study of the Supergiant Fast X-ray Transient Candidate IC 10 X-2
Authors:
Stephanie Kwan,
Ryan M. Lau,
Jacob Jencson,
Mansi M. Kasliwal,
Martha L. Boyer,
Eran Ofek,
Frank Masci,
Russ Laher
Abstract:
We present an optical and infrared (IR) study of IC 10 X-2, a high-mass X-ray binary in the galaxy IC 10. Previous optical and X-ray studies suggest X-2 is a Supergiant Fast X-ray Transient: a large-amplitude (factor of $\sim$ 100), short-duration (hours to weeks) X-ray outburst on 2010 May 21. We analyze R- and g-band light curves of X-2 from the intermediate Palomar Transient Factory taken betwe…
▽ More
We present an optical and infrared (IR) study of IC 10 X-2, a high-mass X-ray binary in the galaxy IC 10. Previous optical and X-ray studies suggest X-2 is a Supergiant Fast X-ray Transient: a large-amplitude (factor of $\sim$ 100), short-duration (hours to weeks) X-ray outburst on 2010 May 21. We analyze R- and g-band light curves of X-2 from the intermediate Palomar Transient Factory taken between 2013 July 15 and 2017 Feb 14 show high-amplitude ($\gtrsim$ 1 mag), short-duration ($\lesssim8$ d) flares and dips ($\gtrsim$ 0.5 mag). Near-IR spectroscopy of X-2 from Palomar/TripleSpec show He I, Paschen-$γ$, and Paschen-$β$ emission lines with similar shapes and amplitudes as those of luminous blue variables (LBVs) and LBV candidates (LBVc). Mid-IR colors and magnitudes from Spitzer/IRAC photometry of X-2 resemble those of known LBV/LBVcs. We suggest that the stellar companion in X-2 is an LBV/LBVc and discuss possible origins of the optical flares. Dips in the optical light curve are indicative of eclipses from optically thick clumps formed in the winds of the stellar counterpart. Given the constraints on the flare duration ($0.02 - 0.8$ d) and the time between flares ($15.1\pm7.8$ d), we estimate the clump volume filling factor in the stellar winds, $f_V$, to be $0.01 < f_V < 0.71$, which overlaps with values measured from massive star winds. In X-2, we interpret the origin of the optical flares as the accretion of clumps formed in the winds of an LBV/LBVc onto the compact object.
△ Less
Submitted 14 December, 2017;
originally announced December 2017.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Testbeam and Laboratory Characterization of CMS 3D Pixel Sensors
Authors:
M. Bubna,
E. Alagoz,
A. Krzywda,
O. Koybasi,
K. Arndt,
D. Bortoletto,
I. Shipsey,
G. Bolla,
A. Kok,
T. -E. Hansen,
T. A. Hansen,
G. U. Jensen,
J. M. Brom,
M. Boscardin,
J. Chramowicz,
J. Cumalat,
G. F. Dalla Betta,
M. Dinardo,
A. Godshalk,
M. Jones,
M. D. Krohn,
A. Kumar,
C. M. Lei,
L. Moroni,
L. Perera
, et al. (10 additional authors not shown)
Abstract:
The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase in luminosity expected with the High- Luminosity LHC (HL-LHC) phase. As a possible replacement for planar sensors, 3D silicon technology is under consideration…
▽ More
The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase in luminosity expected with the High- Luminosity LHC (HL-LHC) phase. As a possible replacement for planar sensors, 3D silicon technology is under consideration due to its good performance after high radiation fluence. In this paper, we report on pre- and post- irradiation measurements for CMS 3D pixel sensors with different electrode configurations. The effects of irradiation on electrical properties, charge collection efficiency, and position resolution of 3D sensors are discussed. Measurements of various test structures for monitoring the fabrication process and studying the bulk and surface properties, such as MOS capacitors, planar and gate-controlled diodes are also presented.
△ Less
Submitted 30 April, 2014; v1 submitted 25 February, 2014;
originally announced February 2014.
-
CMS Pixel Telescope Addition to T-980 Bent Crystal Collimation Experiment at the Tevatron
Authors:
Ryan Rivera,
Jerry Annala,
Todd Johnson,
Simon Kwan,
Carl Lundberg,
Dean Still,
Alan Prosser,
Lorenzo Uplegger,
Jim Zagel,
Viktoriya Zvodaya
Abstract:
An enhancement to the T-980 bent crystal collimation experiment at the Tevatron has been completed. The enhancement was the installation of a pixel telescope inside the vacuum-sealed beam pipe of the Tevatron. The telescope is comprised of six CMS PSI46 pixel plaquettes, arranged as three stations of horizontal and vertical planes, with the CAPTAN system for data acquisition and control. The purpo…
▽ More
An enhancement to the T-980 bent crystal collimation experiment at the Tevatron has been completed. The enhancement was the installation of a pixel telescope inside the vacuum-sealed beam pipe of the Tevatron. The telescope is comprised of six CMS PSI46 pixel plaquettes, arranged as three stations of horizontal and vertical planes, with the CAPTAN system for data acquisition and control. The purpose of the pixel telescope is to measure beam profiles produced by bent crystals under various conditions. The telescope electronics inside the beam pipe initially were not adequately shielded from the image current of the passing beams. A new shielding approach was devised and installed, which resolved the problem. The noise issues encountered and the mitigating techniques are presented herein, as well as some preliminary results from the telescope.
△ Less
Submitted 25 September, 2012;
originally announced September 2012.
-
Advanced Bent Crystal Collimation Studies at the Tevatron (T-980)
Authors:
V. Zvoda,
G. Annala,
R. Carrigan,
A. Drozhdin,
T. Johnson,
S. Kwan,
N. Mokhov,
A. Prosser,
R. Reilly,
R. Rivera L. Uplegger,
V. Shiltsev,
D. Still,
J. Zagel,
V. Guidi,
E. Bagli,
A. Mazzolari,
Yu. Ivanov,
Yu. Chesnokov,
I. Yazynin
Abstract:
The T-980 bent crystal collimation experiment at the Tevatron has recently acquired substantial enhancements. First, two new crystals - a 16-strip one manufactured and characterized by the INFN Ferrara group and a quasi-mosaic crystal manufactured and characterized by the PNPI group. Second, a two plane telescope with 3 high-resolution pixel detectors per plane along with corresponding mechanics,…
▽ More
The T-980 bent crystal collimation experiment at the Tevatron has recently acquired substantial enhancements. First, two new crystals - a 16-strip one manufactured and characterized by the INFN Ferrara group and a quasi-mosaic crystal manufactured and characterized by the PNPI group. Second, a two plane telescope with 3 high-resolution pixel detectors per plane along with corresponding mechanics, electronics, control and software has been manufactured, tested and installed in the E0 crystal region. The purpose of the pixel telescope is to measure and image channeled (CH), volume-reflected (VR) and multiple volume-reflected (MVR) beam profiles produced by bent crystals. Third, an ORIGIN-based system has been developed for thorough analysis of experimental and simulation data. Results of analysis are presented for different types of crystals used from 2005 to present for channeling and volume reflection including pioneering tests of two-plane crystal collimation at the collider, all in comparison with detailed simulations.
△ Less
Submitted 7 March, 2012;
originally announced March 2012.
-
Renaissance of the ~1 TeV Fixed-Target Program
Authors:
T. Adams,
J. A. Appel,
K. E. Arms,
A. B. Balantekin,
J. M. Conrad,
P. S. Cooper,
Z. Djurcic,
W. Dunwoodie,
J. Engelfried,
P. H. Fisher,
E. Gottschalk,
A. de Gouvea,
K. Heller,
C. M. Ignarra,
G. Karagiorgi,
S. Kwan,
W. A. Loinaz,
B. Meadows,
R. Moore,
J. G. Morfín,
D. Naples,
P. Nienaber,
S. F. Pate,
V. Papavassiliou,
A. A. Petrov
, et al. (11 additional authors not shown)
Abstract:
This document describes the physics potential of a new fixed-target program based on a ~1 TeV proton source. Two proton sources are potentially available in the future: the existing Tevatron at Fermilab, which can provide 800 GeV protons for fixed-target physics, and a possible upgrade to the SPS at CERN, called SPS+, which would produce 1 TeV protons on target. In this paper we use an example T…
▽ More
This document describes the physics potential of a new fixed-target program based on a ~1 TeV proton source. Two proton sources are potentially available in the future: the existing Tevatron at Fermilab, which can provide 800 GeV protons for fixed-target physics, and a possible upgrade to the SPS at CERN, called SPS+, which would produce 1 TeV protons on target. In this paper we use an example Tevatron fixed-target program to illustrate the high discovery potential possible in the charm and neutrino sectors. We highlight examples which are either unique to the program or difficult to accomplish at other venues.
△ Less
Submitted 1 October, 2009; v1 submitted 18 May, 2009;
originally announced May 2009.
-
Asymmetries in the Production of Lambda0 in 250 GeV/c pi+-, K+- and p -- Nucleon Interactions
Authors:
G. A. Alves,
S. Amato,
J. C. Anjos,
J. A. Appel,
J. Astorga,
T. Bernard,
S. B. Bracker,
L. M. Cremaldi,
W. D. Dagenhart,
C. L. Darling,
D. Errede,
H. C. Fenker,
C. Gay,
D. R. Green,
R. Jedicke,
P. E. Karchin,
S. Kwan,
L. H. Lueking,
J. R. T. de Mello Neto,
J. Metheny,
R. H. Milburn,
J. M. de Miranda,
H. da Motta,
A. Napier,
M. S. Nicola
, et al. (13 additional authors not shown)
Abstract:
Using data from Fermilab fixed-target experiment E769, we have measured particle-antiparticle production asymmetries for Lambda0 hyperons in 250 GeV/c pi+-, K+- and p -- nucleon interactions. The asymmetries are measured as functions of Feynman-x (x_F) and p_t^2 over the ranges -0.12<=x_F<=0.12 and 0<=p_t^2<=3 (GeV/c)^2 (for positive beam) and -0.12<=x_F<=0.4 and 0<=p_t^2<=10 (GeV/c)^2 (for nega…
▽ More
Using data from Fermilab fixed-target experiment E769, we have measured particle-antiparticle production asymmetries for Lambda0 hyperons in 250 GeV/c pi+-, K+- and p -- nucleon interactions. The asymmetries are measured as functions of Feynman-x (x_F) and p_t^2 over the ranges -0.12<=x_F<=0.12 and 0<=p_t^2<=3 (GeV/c)^2 (for positive beam) and -0.12<=x_F<=0.4 and 0<=p_t^2<=10 (GeV/c)^2 (for negative beam). We find substantial asymmetries, even at x_F around zero. We also observe leading-particle-type asymmetries. These latter effects are qualitatively as expected from valence-quark content of the target and variety of projectiles studied.
△ Less
Submitted 19 March, 2003;
originally announced March 2003.
-
Characterization of Prototype BTeV Silicon Pixel Sensors Before and After Irradiation
Authors:
Maria R. Coluccia,
J. A. Appel,
G. Chiodini,
D. C. Christian,
S. Kwan
Abstract:
We report on measurements performed on silicon pixel sensor prototypes exposed to a 200 MeV proton beam at the Indiana University Cyclotron Facility. The sensors are of n+/n/p+ type with multi-guard ring structures on the p+-side and p-stop electrode isolation on the n+-side. Electrical characterization of the devices was performed before and after irradiation up to a proton fluence of 4E14 p/cm…
▽ More
We report on measurements performed on silicon pixel sensor prototypes exposed to a 200 MeV proton beam at the Indiana University Cyclotron Facility. The sensors are of n+/n/p+ type with multi-guard ring structures on the p+-side and p-stop electrode isolation on the n+-side. Electrical characterization of the devices was performed before and after irradiation up to a proton fluence of 4E14 p/cm2. We tested pixel sensors fabricated from normal and oxygen-enriched silicon wafers and with two different p-stop isolation layouts: common p-stop and individual p-stop.
△ Less
Submitted 8 April, 2002;
originally announced April 2002.
-
Single Event Effects in the Pixel readout chip for BTeV
Authors:
G. Chiodini,
J. A. Appel,
G. Cardoso,
D. C. Christian,
M. R. Coluccia,
J. Hoff,
S. W. Kwan,
A. Mekkaoui,
R. Yarema,
S. Zimmermann
Abstract:
In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 um CMOS processes following radiation tolerant d…
▽ More
In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 um CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.
△ Less
Submitted 29 November, 2001;
originally announced November 2001.
-
Performance of prototype BTeV silicon pixel detectors in a high energy pion beam
Authors:
J. A. Appel,
M. Artuso,
J. N. Butler,
G. Cancelo,
G. Cardoso,
H. Cheung,
G. Chiodini,
D. C. Christian,
A. Colautti,
R. Coluccia,
M. Di Corato,
E. E. Gottschalk,
B. K. Hall,
J. Hoff,
P. A. Kasper,
R. Kutschke,
S. W. Kwan,
A. Mekkaoui,
D. Menasce,
C. Newsom,
S. Sala,
R. Yarema,
J. C. Wang,
S. Zimmerman
Abstract:
The silicon pixel vertex detector is a key element of the BTeV spectrometer. Sensors bump-bonded to prototype front-end devices were tested in a high energy pion beam at Fermilab. The spatial resolution and occupancies as a function of the pion incident angle were measured for various sensor-readout combinations. The data are compared with predictions from our Monte Carlo simulation and very goo…
▽ More
The silicon pixel vertex detector is a key element of the BTeV spectrometer. Sensors bump-bonded to prototype front-end devices were tested in a high energy pion beam at Fermilab. The spatial resolution and occupancies as a function of the pion incident angle were measured for various sensor-readout combinations. The data are compared with predictions from our Monte Carlo simulation and very good agreement is found.
△ Less
Submitted 8 August, 2001; v1 submitted 7 August, 2001;
originally announced August 2001.
-
Beam Test of BTeV Pixel Detectors
Authors:
J. C. Wang,
J. A. Appel,
M. Artuso,
J. N. Butler,
G. Cancelo,
G. Cardoso,
H. Cheung,
G. Chiodini,
D. C. Christian,
A. Colautti,
R. Coluccia,
M. Di Corato,
E. E. Gottschalk,
B. K. Hall,
J. Hoff,
P. A. Kasper,
R. Kutschke,
S. W. Kwan,
A. Mekkaoui,
D. Menasce,
C. Newsom,
S. Sala,
R. Yarema S. Zimmermann
Abstract:
The silicon pixel vertex detector is one of the key elements of the BTeV spectrometer. Detector prototypes were tested in a beam at Fermilab. We report here on the measured spatial resolution as a function of the incident angles for different sensor-readout electronics combinations. We compare the results with predictions from our Monte Carlo simulation.
The silicon pixel vertex detector is one of the key elements of the BTeV spectrometer. Detector prototypes were tested in a beam at Fermilab. We report here on the measured spatial resolution as a function of the incident angles for different sensor-readout electronics combinations. We compare the results with predictions from our Monte Carlo simulation.
△ Less
Submitted 21 November, 2000;
originally announced November 2000.
-
Beam Test Results of the BTeV Silicon Pixel Detector
Authors:
G. Chiodini,
J. A. Appel,
M. Artuso,
J. N. Butler,
G. Cardoso,
H. Cheung,
D. C. Christian,
A. Colautti,
R. Coluccia,
M. Di Corato,
E. E. Gottschalk,
B. K. Hall,
J. Hoff,
P. A. Kasper,
R. Kutschke,
S. W. Kwan,
A. Mekkaoui,
D. Menasce,
C. Newsom,
S. Sala,
R. Yarema,
J. C. Wang,
S. Zimmermann
Abstract:
The results of the BTeV silicon pixel detector beam test carried out at Fermilab in 1999-2000 are reported. The pixel detector spatial resolution has been studied as a function of track inclination, sensor bias, and readout threshold.
The results of the BTeV silicon pixel detector beam test carried out at Fermilab in 1999-2000 are reported. The pixel detector spatial resolution has been studied as a function of track inclination, sensor bias, and readout threshold.
△ Less
Submitted 7 September, 2000;
originally announced September 2000.
-
Asymmetries between the production of D+ and D- mesons from 500 GeV/c pi- nucleon interactions as a function of xF and pt**2
Authors:
E. M. Aitala,
S. Amato,
J. C. Anjos,
J. A. Appel,
M. Aryal,
D. Ashery,
J. Astorga,
S. Banerjee,
I. Bediaga,
G. Blaylock,
S. B. Bracker,
P. R. Burchat,
R. A. Burnstein,
T. Carter,
H. S. Carvalho,
I. Costa,
L. M. Cremaldi,
C. Darling,
K. Denisenko,
A. Fernandez,
P. Gagnon,
S. Gerzon,
C. Gobel,
K. Gounder,
D. Granite
, et al. (53 additional authors not shown)
Abstract:
We present asymmetries between the production of D+ and D- mesons in Fermilab experiment E791 as a function of xF and pt**2. The data used here consist of 74,000 fully-reconstructed charmed mesons produced by a 500 GeV/c pi- beam on C and Pt foils. The measurements are compared to results of models which predict differences between the production of heavy-quark mesons that have a light quark in…
▽ More
We present asymmetries between the production of D+ and D- mesons in Fermilab experiment E791 as a function of xF and pt**2. The data used here consist of 74,000 fully-reconstructed charmed mesons produced by a 500 GeV/c pi- beam on C and Pt foils. The measurements are compared to results of models which predict differences between the production of heavy-quark mesons that have a light quark in common with the beam (leading particles) and those that do not (non-leading particles). While the default models do not agree with our data, we can reach agreement with one of them, PYTHIA, by making a limited number of changes to parameters used.
△ Less
Submitted 3 January, 1996;
originally announced January 1996.