Skip to main content

Showing 1–7 of 7 results for author: Kuzmin, M V

.
  1. arXiv:2406.14628  [pdf, other

    hep-ph nucl-th

    Gluon radiation inside a flowing medium

    Authors: Matvey V. Kuzmin, Xoán Mayo López

    Abstract: We compute the spectrum of gluons emitted by a highly energetic quark inside a flowing QCD medium, focusing on the soft gluon limit at first order in the opacity expansion. Specifically, we derive the leading energy-suppressed corrections to the double differential final parton distribution, and show that they are substantial for both static and flowing matter. In particular, we demonstrate that t… ▽ More

    Submitted 20 June, 2024; originally announced June 2024.

    Comments: 29 pages, 5 figures

  2. Jet quenching in anisotropic flowing matter

    Authors: Matvey V. Kuzmin, Xoán Mayo López, Jared Reiten, Andrey V. Sadofyev

    Abstract: We study the interplay between the flow and hydrodynamic gradients in jet quenching at first order in opacity. We find that the mixed flow-gradient contributions in jet quenching are enhanced by the medium length, and survive in the eikonal limit, dominating over other medium evolution effects. The resulting modification to the jet quenching parameter and energy loss rate can be substantial, leadi… ▽ More

    Submitted 5 February, 2024; v1 submitted 1 September, 2023; originally announced September 2023.

    Comments: 36 pages, 6 figures, published version

  3. arXiv:hep-ex/0104046   

    hep-ex

    The e/h ratio of the ATLAS Hadronic Tile Calorimeter

    Authors: J. A. Budagov, Y. A. Kulchitsky, M. V. Kuzmin, V. B. Vinogradov

    Abstract: This paper has been withdrawn by the authors.

    Submitted 22 May, 2001; v1 submitted 26 April, 2001; originally announced April 2001.

  4. arXiv:hep-ex/9912028  [pdf, ps, other

    hep-ex

    Longitudinal Hadronic Shower Development in a Combined Calorimeter

    Authors: Y. A. Kulchitsky, M. V. Kuzmin, V. B. Vinogradov

    Abstract: This work is devoted to the experimental study of the longitudinal hadronic shower development in the ATLAS barrel combined prototype calorimeter consisting of the lead-liquid argon electromagnetic part and the iron-scintillator hadronic part. The results have been obtained on the basis of the 1996 combined test beam data which have been taken on the H8 beam of the CERN SPS, with the pion beams… ▽ More

    Submitted 14 December, 1999; originally announced December 1999.

    Comments: Latex, 21 pages, 10 figures

    Report number: JINR-E1-99-326

  5. arXiv:hep-ex/9912014  [pdf, ps, other

    hep-ex

    The e/h Method of Energy Reconstruction for Combined Calorimeter

    Authors: Y. A. Kulchitsky, M. V. Kuzmin, V. B. Vinogradov

    Abstract: The new simple method of the energy reconstruction for a combined calorimeter, which we called the e/h method, is suggested. It uses only the known e/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. The method has been tested on the basis of the 1996 test beam data of the combined calorimeter and demonstrated th… ▽ More

    Submitted 7 December, 1999; originally announced December 1999.

    Comments: LATEX, 21 pages, 8 figures

    Report number: Preprint JINR-E1-99-317, 1999, JINR, Dubna, Russia

  6. arXiv:hep-ex/9911033  [pdf, ps, other

    hep-ex

    Non-compensation of an Electromagnetic Compartment of a Combined Calorimeter

    Authors: Y. A. Kulchitsky, M. V. Kuzmin, V. B. Vinogradov

    Abstract: The method of extraction of the $e/h$ ratio, the degree of non-compensation, of the electromagnetic compartment of the combined calorimeter is suggested. The $e/h$ ratio of $1.74\pm0.04$ has been determined on the basis of the 1996 combined calorimeter test beam data. This value agrees with the prediction that $e/h > 1.7$ for this electromagnetic calorimeter.

    Submitted 23 November, 1999; originally announced November 1999.

    Comments: LATEX, 17 pages, 7 figures

    Report number: JINR-E1-99-303 (1999) 17 p., JINR, Dubna, Russia

  7. arXiv:hep-ex/9911007  [pdf, ps, other

    hep-ex

    Non-compensation of the Barrel Combined Calorimeter Prototype

    Authors: Y. A. Kulchitsky, M. V. Kuzmin

    Abstract: The e/$π$ ratio for the Barrel Combined Calorimeter Prototype, composed from electromagnetic LAr calorimeter and hadronic Tile calorimter was investigated. Response of Combined Calorimeter on pions and electrons in the energy region 20 - 300 GeV was studied. Found $e/h = 1.37\pm0.01\pm0.02$ is in good agreement with results from previous Combined Calorimeter test but has more precisions.

    Submitted 5 November, 1999; originally announced November 1999.

    Comments: LATEX, 11 pages, 4 figures

    Report number: Preprint JINR-E1-98-336 (1998), JINR, Dubna, Russia