-
Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures: II
Authors:
M. Kobayashi,
R. Yonamine,
T. Tomioka,
A. Aoza,
H. Bito,
K. Fujii,
T. Higashi,
K. Hiramatsu,
K. Ikematsu,
A. Ishikawa,
Y. Kato,
H. Kuroiwa,
T. Matsuda,
O. Nitoh,
H. Ohta,
K. Sakai,
R. D. Settles,
A. Sugiyama,
H. Tsuji,
T. Watanabe,
H. Yamaoka,
T. Yazu
Abstract:
The spatial resolution along the pad-row direction was measured with a GEM-based TPC prototype for the future linear collider experiment in order to understand its performance for tracks with finite projected angles with respect to the pad-row normal. The degradation of the resolution due to the angular pad effect was confirmed to be consistent with the prediction of a simple calculation taking in…
▽ More
The spatial resolution along the pad-row direction was measured with a GEM-based TPC prototype for the future linear collider experiment in order to understand its performance for tracks with finite projected angles with respect to the pad-row normal. The degradation of the resolution due to the angular pad effect was confirmed to be consistent with the prediction of a simple calculation taking into account the cluster-size distribution and the avalanche fluctuation.
△ Less
Submitted 3 April, 2014;
originally announced April 2014.
-
Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures
Authors:
M. Kobayashi,
R. Yonamine,
T. Tomioka,
A. Aoza,
H. Bito,
K. Fujii,
T. Higashi,
K. Hiramatsu,
K. Ikematsu,
A. Ishikawa,
Y. Kato,
H. Kuroiwa,
T. Matsuda,
O. Nitoh,
H. Ohta,
K. Sakai,
R. D. Settles,
A. Sugiyama,
H. Tsuji,
T. Watanabe,
H. Yamaoka,
T. Yazu
Abstract:
Argon with an admixture of CF4 is expected to be a good candidate for the gas mixture to be used for a time projection chamber (TPC) in the future linear collider experiment because of its small transverse diffusion of drift electrons especially under a strong magnetic field. In order to confirm the superiority of this gas mixture over conventional TPC gases we carried out cosmic ray tests using a…
▽ More
Argon with an admixture of CF4 is expected to be a good candidate for the gas mixture to be used for a time projection chamber (TPC) in the future linear collider experiment because of its small transverse diffusion of drift electrons especially under a strong magnetic field. In order to confirm the superiority of this gas mixture over conventional TPC gases we carried out cosmic ray tests using a GEM-based TPC operated mostly in Ar-CF4-isobutane mixtures under 0 - 1 T axial magnetic fields. The measured gas properties such as gas gain and transverse diffusion constant as well as the observed spatial resolution are presented.
△ Less
Submitted 21 March, 2023; v1 submitted 30 August, 2010;
originally announced August 2010.
-
Cosmic Ray Tests of the Prototype TPC for the ILC Experiment
Authors:
K. Ackermann,
S. Arai,
D. C. Arogancia,
A. M. Bacala,
M. Ball,
T. Behnke,
H. Bito,
V. Eckardt,
K. Fujii,
T. Fusayasu,
N. Ghodbane,
H. C. Gooc Jr.,
T. Kijima,
M. Hamann,
M. Habu,
R. -D. Heuer,
K. Hiramatsu,
K. Ikematsu,
A. Kaukher,
H. Kuroiwa,
M. E. Janssen,
Y. Kato,
M. Kobayashi,
T. Kuhl,
T. Lux
, et al. (25 additional authors not shown)
Abstract:
A time projection chamber (TPC) is a strong candidate for the central tracker of the international linear collider (ILC) experiment and we have been conducting a series of cosmic ray experiments under a magnetic field up to 4 T, using a small prototype TPC with a replaceable readout device: multi-wire proportional chamber (MWPC) or gas electron multiplier (GEM). We first confirmed that the MWPC…
▽ More
A time projection chamber (TPC) is a strong candidate for the central tracker of the international linear collider (ILC) experiment and we have been conducting a series of cosmic ray experiments under a magnetic field up to 4 T, using a small prototype TPC with a replaceable readout device: multi-wire proportional chamber (MWPC) or gas electron multiplier (GEM). We first confirmed that the MWPC readout could not be a fall-back option of the ILC-TPC under a strong axial magnetic field of 4 T since its spatial resolution suffered severely from the so called E x B effect in the vicinity of the wire planes. The GEM readout, on the other hand, was found to be virtually free from the E x B effect as had been expected and gave the resolution determined by the transverse diffusion of the drift electrons (diffusion limited). Furthermore, GEMs allow a wider choice of gas mixtures than MWPCs. Among the gases we tried so far a mixture of Ar-CF4-isobutane, in which MWPCs could be prone to discharges, seems promising as the operating gas of the ILC-TPC because of its small diffusion constant especially under a strong magnetic field. We report the measured drift properties of this mixture including the diffusion constant as a function of the electric field and compare them with the predictions of Magboltz. Also presented is the spatial resolution of a GEM-based ILC-TPC estimated from the measurement with the prototype.
△ Less
Submitted 18 May, 2009;
originally announced May 2009.
-
A GEM TPC End-Panel Pre-Prototype
Authors:
A. Ishikawa,
A. Aoza,
T. Higashi,
A. Sugiyama,
H. Tsuji,
Y. Kato,
K. Hiramatsu,
T. Yazu,
T. Watanabe,
O. Nitoh,
H. Ohta,
K. Sakai,
H. Bito,
K. Fujii,
M. Kobayashi,
H. Kuroiwa,
T. Matsuda,
R. Yonamine,
Y. Gao,
Y. Li,
J. Li,
L. Cao,
Z. Yang,
A. Bacala,
C. J. Gooc
, et al. (2 additional authors not shown)
Abstract:
A GEM TPC end panel pre-prototype was constructed for a large LC-TPC prototype to test its basic design philosophy and some of its engineering details. Its interim test results are presented.
A GEM TPC end panel pre-prototype was constructed for a large LC-TPC prototype to test its basic design philosophy and some of its engineering details. Its interim test results are presented.
△ Less
Submitted 1 October, 2007;
originally announced October 2007.
-
Absence of Hybridization Gap in Heavy Electron Systems and Analysis of YbAl3 in terms of Nearly Free Electron Conduction Band
Authors:
Hiroyuki Kuroiwa,
Yoshiki Imai,
Tetsuro Saso
Abstract:
In the analysis of the heavy electron systems, theoretical models with c-f hybridization gap are often used. We point out that such a gap does not exist and the simple picture with the hybridization gap is misleading in the metallic systems, and present a correct picture by explicitly constructing an effective band model of YbAl_3. Hamiltonian consists of a nearly free electron model for conduct…
▽ More
In the analysis of the heavy electron systems, theoretical models with c-f hybridization gap are often used. We point out that such a gap does not exist and the simple picture with the hybridization gap is misleading in the metallic systems, and present a correct picture by explicitly constructing an effective band model of YbAl_3. Hamiltonian consists of a nearly free electron model for conduction bands which hybridize with localized f-electrons, and includes only a few parameters. Density of states, Sommerfeld coefficient, f-electron number and optical conductivity are calculated and compared with the band calculations and the experiments.
△ Less
Submitted 23 July, 2007;
originally announced July 2007.
-
Lorentz Angle Measurement for CO2/Isobutane Gas Mixtures
Authors:
K. Hoshina,
K. Fujii,
N. Khalatyan,
O. Nitoh,
H. Okuno,
Y. Kato,
M. Kobayashi,
Y. Kurihara,
H. Kuroiwa,
Y. Nakamura,
K. Sakieda,
Y. Suzuki,
T. Watanabe
Abstract:
We have developed a Lorentz angle measurement system for cool gas mixtures in the course of our R&D for a proposed JLC central drift chamber (JLC-CDC). The measurement system is characterized by the use of two laser beams to produce primary electrons and flash ADCs to read their signals simultaneously. With this new system, we have measured Lorentz angles for CO2/isobutane gas mixtures with diff…
▽ More
We have developed a Lorentz angle measurement system for cool gas mixtures in the course of our R&D for a proposed JLC central drift chamber (JLC-CDC). The measurement system is characterized by the use of two laser beams to produce primary electrons and flash ADCs to read their signals simultaneously. With this new system, we have measured Lorentz angles for CO2/isobutane gas mixtures with different proportions (95:5, 90:10, and 85:15), varying drift field from 0.6 to 2.0 kV/cm and magnetic field up to 1.5 T. The results of the measurement are in good agreement with GARFIELD/MAGBOLTZ simulations.
△ Less
Submitted 1 December, 2000;
originally announced December 2000.