-
Systematic study of tunable laser cooling for trapped-ion experiments
Authors:
A. P. Kulosa,
O. N. Prudnikov,
D. Vadlejch,
H. A. Fürst,
A. A. Kirpichnikova,
A. V. Taichenachev,
V. I. Yudin,
T. E. Mehlstäubler
Abstract:
We report on a comparative analysis of quenched sideband cooling in trapped ions. We introduce a theoretical approach for time-efficient simulation of the temporal cooling characteristics and derive the optimal conditions providing fast laser cooling into the ion's motional ground state. The simulations were experimentally benchmarked with a single $^{172}$Yb$^+$ ion confined in a linear Paul trap…
▽ More
We report on a comparative analysis of quenched sideband cooling in trapped ions. We introduce a theoretical approach for time-efficient simulation of the temporal cooling characteristics and derive the optimal conditions providing fast laser cooling into the ion's motional ground state. The simulations were experimentally benchmarked with a single $^{172}$Yb$^+$ ion confined in a linear Paul trap. Sideband cooling was carried out on a narrow quadrupole transition, enhanced with an additional clear-out laser for controlling the effective linewidth of the cooling transition. Quench cooling was thus for the first time studied in the resolved sideband, intermediate and semi-classical regime. We discuss the non-thermal distribution of Fock states during laser cooling and reveal its impact on time dilation shifts in optical atomic clocks.
△ Less
Submitted 9 January, 2023;
originally announced January 2023.
-
Motional heating of spatially extended ion crystals
Authors:
D. Kalincev,
L. S. Dreissen,
A. P. Kulosa,
C-H. Yeh,
H. A. Fürst,
T. E. Mehlstäubler
Abstract:
We study heating of motional modes of a single ion and of extended ion crystals trapped in a linear radio frequency (rf) Paul trap with a precision of $Δ\dot{\bar{n}} \approx 0.2 $ phonons s$^{-1}$. Single-ion axial and radial heating rates are consistent and electric field noise has been stable over the course of four years. At a secular frequency of $ω_\mathrm{sec}=2π\times620$ kHz, we measure…
▽ More
We study heating of motional modes of a single ion and of extended ion crystals trapped in a linear radio frequency (rf) Paul trap with a precision of $Δ\dot{\bar{n}} \approx 0.2 $ phonons s$^{-1}$. Single-ion axial and radial heating rates are consistent and electric field noise has been stable over the course of four years. At a secular frequency of $ω_\mathrm{sec}=2π\times620$ kHz, we measure $\dot{\bar{n}} = 0.56(6)$ phonons s$^{-1}$ per ion for the center-of-mass (com) mode of linear chains of up to eleven ions and observe no significant heating of the out-of-phase (oop) modes. By displacing the ions away from the nodal line, inducing excess micromotion, rf noise heats the com mode quadratically as a function of radial displacement $r$ by $\dot{\bar{n}}(r)/ r^2 = 0.89(4)$ phonons s$^{-1}$ $μ$m$^{-2}$ per ion, while the oop modes are protected from rf-noise induced heating in linear chains. By changing the quality factor of the resonant rf circuit from $Q=542$ to $Q=204$, we observe an increase of rf noise by a factor of up to 3. We show that the rf-noise induced heating of motional modes of extended crystals also depends on the symmetry of the crystal and of the mode itself. As an example, we consider several 2D and 3D crystal configurations. Heating rates of up to 500 phonons s$^{-1}$ are observed for individual modes, giving rise to a total kinetic energy increase and thus a fractional time dilation shift of up to $-0.3\times 10^{-18}$ s$^{-1}$ of the total system. In addition, we detail on how the excitation probability of the individual ions is reduced and decoherence is increased due to the Debye-Waller effect.
△ Less
Submitted 28 May, 2021; v1 submitted 18 December, 2020;
originally announced December 2020.
-
Coherent excitation of the highly forbidden electric octupole transition in ${}^{172}$Yb$^+$
Authors:
Henning A. Fürst,
Chih-Han Yeh,
Dimitri Kalincev,
André P. Kulosa,
Laura S. Dreissen,
Richard Lange,
Erik Benkler,
Nils Huntemann,
Ekkehard Peik,
Tanja E. Mehlstäubler
Abstract:
We report on the first coherent excitation of the highly forbidden $^2S_{1/2}\rightarrow{}^2F_{7/2}$ electric octupole (E3) transition in a single trapped ${}^{172}$Yb$^+$ ion, an isotope without nuclear spin. Using the transition in ${}^{171}$Yb$^+$ as a reference, we determine the transition frequency to be $642\,116\,784\,950\,887.6(2.4)\,$Hz. We map out the magnetic field environment using the…
▽ More
We report on the first coherent excitation of the highly forbidden $^2S_{1/2}\rightarrow{}^2F_{7/2}$ electric octupole (E3) transition in a single trapped ${}^{172}$Yb$^+$ ion, an isotope without nuclear spin. Using the transition in ${}^{171}$Yb$^+$ as a reference, we determine the transition frequency to be $642\,116\,784\,950\,887.6(2.4)\,$Hz. We map out the magnetic field environment using the forbidden $^2S_{1/2} \rightarrow{}^2D_{5/2}$ electric quadrupole (E2) transition and determine its frequency to be $729\,476\,867\,027\,206.8(4.4)\,$Hz. Our results are a factor of $1\times10^5$ ($3\times10^{5}$) more accurate for the E2 (E3) transition compared to previous measurements. The results open up the way to search for new physics via precise isotope shift measurements and improved tests of local Lorentz invariance using the metastable $^2F_{7/2}$ state of Yb$^+$.
△ Less
Submitted 25 June, 2020;
originally announced June 2020.
-
Controlling systematic frequency uncertainties at the $10^{-19}$ level in linear Coulomb crystals
Authors:
J. Keller,
T. Burgermeister,
D. Kalincev,
A. Didier,
A. P. Kulosa,
T. Nordmann,
J. Kiethe,
T. E. Mehlstäubler
Abstract:
Trapped ions are ideally suited for precision spectroscopy, as is evident from the remarkably low systematic uncertainties of single-ion clocks. The major weakness of these clocks is the long averaging time, necessitated by the low signal of a single atom. An increased number of ions can overcome this limitation and allow for the implementation of novel clock schemes. However, this presents the ch…
▽ More
Trapped ions are ideally suited for precision spectroscopy, as is evident from the remarkably low systematic uncertainties of single-ion clocks. The major weakness of these clocks is the long averaging time, necessitated by the low signal of a single atom. An increased number of ions can overcome this limitation and allow for the implementation of novel clock schemes. However, this presents the challenge to maintain the excellent control over systematic shifts of a single particle in spatially extended and strongly coupled many-body systems. We measure and deduce systematic frequency uncertainties related to spectroscopy with ion chains in a newly developed rf trap array designed for precision spectroscopy on simultaneously trapped ion ensembles. For the example of an In${}^+$ clock, sympathetically cooled with Yb${}^+$ ions, we show in our system that the expected systematic frequency uncertainties related to multi-ion operation can be below $1\times10^{-19}$. Our results pave the way to advanced spectroscopy schemes such as entangled clock spectroscopy and cascaded clock operation.
△ Less
Submitted 21 October, 2018; v1 submitted 22 March, 2018;
originally announced March 2018.
-
Probing Time Dilation in Coulomb Crystals in a high-precision Ion Trap
Authors:
J. Keller,
D. Kalincev,
T. Burgermeister,
A. P. Kulosa,
A. Didier,
T. Nordmann,
J. Kiethe,
T. E. Mehlstäubler
Abstract:
Trapped-ion optical clocks are capable of achieving systematic fractional frequency uncertainties of $10^{-18}$ and possibly below. However, the stability of current ion clocks is fundamentally limited by the weak signal of single-ion interrogation. We present an operational, scalable platform for extending clock spectroscopy to arrays of Coulomb crystals consisting of several tens of ions, while…
▽ More
Trapped-ion optical clocks are capable of achieving systematic fractional frequency uncertainties of $10^{-18}$ and possibly below. However, the stability of current ion clocks is fundamentally limited by the weak signal of single-ion interrogation. We present an operational, scalable platform for extending clock spectroscopy to arrays of Coulomb crystals consisting of several tens of ions, while allowing systematic shifts as low as $10^{-19}$. Using a newly developed technique, we observe 3D excess micromotion amplitudes inside a Coulomb crystal with atomic spatial resolution and sub-nanometer amplitude uncertainties. We show that in ion Coulomb crystals of 400$μ$m and 2mm length, time dilation shifts of In${}^+$ ions due to micromotion can be close to $1\times10^{-19}$ and below $10^{-18}$, respectively. In previous ion traps, excess micromotion would have dominated the uncertainty budget for spectroscopy of even a few ions. By minimizing its contribution and providing a means to quantify it, this work opens up the path to precision spectroscopy in many-body ion systems, enabling entanglement-enhanced ion clocks and providing a well-controlled, strongly coupled quantum system.
△ Less
Submitted 21 October, 2018; v1 submitted 6 December, 2017;
originally announced December 2017.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
S. Origlia,
S. Schiller,
M. S. Pramod,
L. Smith,
Y. Singh,
W. He,
S. Viswam,
D. Świerad,
J. Hughes,
K. Bongs,
U. Sterr,
Ch. Lisdat,
S. Vogt,
S. Bize,
J. Lodewyck,
R. Le Targat,
D. Holleville,
B. Venon,
P. Gill,
G. Barwood,
I. R. Hill,
Y. Ovchinnikov,
A. Kulosa,
W. Ertmer,
E. -M. Rasel
, et al. (3 additional authors not shown)
Abstract:
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than…
▽ More
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.
△ Less
Submitted 19 March, 2016;
originally announced March 2016.
-
Towards a Mg lattice clock: Observation of the $^1S_{0}-$$^3P_{0}$ transition and determination of the magic wavelength
Authors:
A. P. Kulosa,
D. Fim,
K. H. Zipfel,
S. Rühmann,
S. Sauer,
N. Jha,
K. Gibble,
W. Ertmer,
E. M. Rasel,
M. S. Safronova,
U. I. Safronova,
S. G. Porsev
Abstract:
We optically excite the electronic state $3s3p~^3P_{0}$ in $^{24}$Mg atoms, laser-cooled and trapped in a magic-wavelength lattice. An applied magnetic field enhances the coupling of the light to the otherwise strictly forbidden transition. We determine the magic wavelength, the quadratic magnetic Zeeman shift and the transition frequency to be 468.463(207)$\,$nm, -206.6(2.0)$\,$MHz/T$^2$ and 655…
▽ More
We optically excite the electronic state $3s3p~^3P_{0}$ in $^{24}$Mg atoms, laser-cooled and trapped in a magic-wavelength lattice. An applied magnetic field enhances the coupling of the light to the otherwise strictly forbidden transition. We determine the magic wavelength, the quadratic magnetic Zeeman shift and the transition frequency to be 468.463(207)$\,$nm, -206.6(2.0)$\,$MHz/T$^2$ and 655 058 646 691(101)$\,$kHz, respectively. These are compared with theoretical predictions and results from complementary experiments. We also developed a high-precision relativistic structure model for magnesium, give an improved theoretical value for the blackbody radiation shift and discuss a clock based on bosonic magnesium.
△ Less
Submitted 5 August, 2015;
originally announced August 2015.
-
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
Authors:
S. Schiller,
A. Görlitz,
A. Nevsky,
S. Alighanbari,
S. Vasilyev,
C. Abou-Jaoudeh,
G. Mura,
T. Franzen,
U. Sterr,
S. Falke,
Ch. Lisdat,
E. Rasel,
A. Kulosa,
S. Bize,
J. Lodewyck,
G. M. Tino,
N. Poli,
M. Schioppo,
K. Bongs,
Y. Singh,
P. Gill,
G. Barwood,
Y. Ovchinnikov,
J. Stuhler,
W. Kaenders
, et al. (6 additional authors not shown)
Abstract:
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (map** of the gravitational potential of Earth), and astronomy (providing local oscillators for radio…
▽ More
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (map** of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.
△ Less
Submitted 17 June, 2012;
originally announced June 2012.
-
An ultraviolet laser system for laser cooling and trap** of metastable magnesium
Authors:
A. P. Kulosa,
J. Friebe,
M. P. Riedmann,
A. Pape,
T. W. Wübbena,
D. B. Fim,
S. Rühmann,
K. H. Zipfel,
H. Kelkar,
W. Ertmer,
E. M. Rasel
Abstract:
We report on a reliable laser system for cooling magnesium atoms in the metastable 3P manifold. The three relevant transitions coupling the 3P to the 3D manifold are near 383 nm and seperated by several hundred GHz. The laser system consists of three diode lasers at 766 nm. All lasers are frequency stabilised to a single pre-stabilised transfer cavity. The applied scheme for frequency control grea…
▽ More
We report on a reliable laser system for cooling magnesium atoms in the metastable 3P manifold. The three relevant transitions coupling the 3P to the 3D manifold are near 383 nm and seperated by several hundred GHz. The laser system consists of three diode lasers at 766 nm. All lasers are frequency stabilised to a single pre-stabilised transfer cavity. The applied scheme for frequency control greatly reduces the complexity of operating three lasers combined with resonant frequency doubling stages and provides a high reliability necessary for complex atomic physics experiments.
△ Less
Submitted 29 May, 2012; v1 submitted 18 January, 2012;
originally announced January 2012.