Contrast-agent-induced deterministic component of CT-density in the abdominal aorta during routine angiography: proof of concept study
Authors:
Maria R. Kodenko,
Yuriy A. Vasilev,
Nicholas S. Kulberg,
Andrey V. Samorodov,
Anton V. Vladzimirskyy,
Olga V. Omelyanskaya,
Roman V. Reshetnikov
Abstract:
Background and objective: CTA is a gold standard of preoperative diagnosis of abdominal aorta and typically used for geometric-only characteristic extraction. We assume that a model describing the dynamic behavior of the contrast agent in the vessel can be developed from the data of routine CTA studies, allowing the procedure to be investigated and optimized without the need for additional perfusi…
▽ More
Background and objective: CTA is a gold standard of preoperative diagnosis of abdominal aorta and typically used for geometric-only characteristic extraction. We assume that a model describing the dynamic behavior of the contrast agent in the vessel can be developed from the data of routine CTA studies, allowing the procedure to be investigated and optimized without the need for additional perfusion CT studies. Obtained spatial distribution of CA can be valuable for both increasing the diagnostic value of a particular study and improving the CT data processing tools. Methods: In accordance with the Beer-Lambert law and the absence of chemical interaction between blood and CA, we postulated the existence of a deterministic CA-induced component in the CT signal density. The proposed model, having a double-sigmoid structure, contains six coefficients relevant to the properties of hemodynamics. To validate the model, expert segmentation was performed using the 3D Slicer application for the CTA data obtained from publicly available source. The model was fitted to the data using the non-linear least square method with Levenberg-Marquardt optimization. Results: We analyzed 594 CTA images (4 studies with median size of 144 slices, IQR [134; 158.5]; 1:1 normal:pathology balance). Goodness-of-fit was proved by Wilcox test (p-value > 0.05 for all cases). The proposed model correctly simulated normal blood flow and hemodynamics disturbances caused by local abnormalities (aneurysm, thrombus and arterial branching). Conclusions: Proposed approach can be useful for personalized CA modeling of vessels, improvement of CTA image processing and preparation of synthetic CT training data for artificial intelligence.
△ Less
Submitted 3 November, 2023; v1 submitted 31 October, 2023;
originally announced October 2023.
-
Automatic segmentation and determining radiodensity of the liver in a large-scale CT database
Authors:
N. S. Kulberg,
A. B. Elizarov,
V. P. Novik,
V. A. Gombolevsky,
A. P. Gonchar,
A. L. Alliua,
V. Yu. Bosin,
A. V. Vladzymyrsky,
S. P. Morozov
Abstract:
This study proposes an automatic technique for liver segmentation in computed tomography (CT) images. Localization of the liver volume is based on the correlation with an optimized set of liver templates developed by the authors that allows clear geometric interpretation. Radiodensity values are calculated based on the boundaries of the segmented liver, which allows identifying liver abnormalities…
▽ More
This study proposes an automatic technique for liver segmentation in computed tomography (CT) images. Localization of the liver volume is based on the correlation with an optimized set of liver templates developed by the authors that allows clear geometric interpretation. Radiodensity values are calculated based on the boundaries of the segmented liver, which allows identifying liver abnormalities. The performance of the technique was evaluated on 700 CT images from dataset of the Unified Radiological Information System (URIS) of Moscow. Despite the decrease in accuracy, the technique is applicable to CT volumes with a partially visible region of the liver. The technique can be used to process CT images obtained in various patient positions in a wide range of exposition parameters. It is capable in dealing with low dose CT scans in real large-scale medical database with over 1 million of studies.
△ Less
Submitted 31 December, 2019;
originally announced December 2019.
-
Discovery of Two Types of Twinkling Can Explain Contradictory Observations among Twinkling Artifact Investigators in Ultrasound Imaging
Authors:
Denis Leonov,
Nicholas Kulberg,
Alexandr Gromov,
Anton Vladzymyrskyy,
Sergey Morozov
Abstract:
Twinkling Artifact is a valuable tool in detecting dense objects such as kidney stones, calculi etc., especially when there is no acoustic shadowing and presence of hyperechogenic tissues obstructs visualization. This phenomenon is not completely understood. Different scientific groups have contradictory findings concerning its properties: some of them observed a decrease in Twinkling intensity at…
▽ More
Twinkling Artifact is a valuable tool in detecting dense objects such as kidney stones, calculi etc., especially when there is no acoustic shadowing and presence of hyperechogenic tissues obstructs visualization. This phenomenon is not completely understood. Different scientific groups have contradictory findings concerning its properties: some of them observed a decrease in Twinkling intensity at elevated pulse repetition frequencies (PRF), while others found Twinkling to be independent from PRF, etc. In this paper we hypothesize that this kind of contradictions can be partially resolved on an assumption that there are two types of Twinkling. The 1st type presumably is produced by random-phased reflections from microcavitation and can be registered even at PRF high enough to suppress blood flow. The 2nd is originated from elastic vibrations as the object under investigation swings like a pendulum in the field of ultrasound. These vibrations can be associated with an external source such as a muscles contraction, etc. or the acoustic radiation force from signals emitted by the transducer. The 2nd type of Twinkling disappears at high PRF and can be regularly observed in silicone and polyurethane phantoms where the occurrence of cavitation microbubbles is highly unlikely. Key Words: Ultrasound Imaging, Twinkling Artifact, Stone Detection, Doppler Effect, Color Frame Map**, Acoustic Radiation Force, Elastic Vibration, Ultrasound Phantom, Cavitation, Microbubbles.
△ Less
Submitted 5 December, 2019;
originally announced December 2019.
-
Clinical acceptance of software based on artificial intelligence technologies (radiology)
Authors:
S. P. Morozov,
A. V. Vladzymyrskyy,
V. G. Klyashtornyy,
A. E. Andreychenko,
N. S. Kulberg,
V. A. Gombolevsky,
K. A. Sergunova
Abstract:
Aim: provide a methodological framework for the process of clinical tests, clinical acceptance, and scientific assessment of algorithms and software based on the artificial intelligence (AI) technologies. Clinical tests are considered as a preparation stage for the software registration as a medical product. The authors propose approaches to evaluate accuracy and efficiency of the AI algorithms fo…
▽ More
Aim: provide a methodological framework for the process of clinical tests, clinical acceptance, and scientific assessment of algorithms and software based on the artificial intelligence (AI) technologies. Clinical tests are considered as a preparation stage for the software registration as a medical product. The authors propose approaches to evaluate accuracy and efficiency of the AI algorithms for radiology.
△ Less
Submitted 27 February, 2020; v1 submitted 1 August, 2019;
originally announced August 2019.