-
Impact of $^7$Be breakup on $^7$Li(p,n) Neutron Spectrum
Authors:
Midhun C. V,
M. M Musthafa,
S. V Suryanarayana,
T. Santhosh,
A. Baishya,
P. Patil,
A Pal,
P. C Rout,
S Santra,
R. Kujur,
Antony Joseph,
Shaima A,
Hajara. K,
P. T. M Shan,
Satheesh B,
Y. Sawant,
B. V. John,
E. T Mirgule,
K. C Jagadeesan,
S. Ganesan
Abstract:
The formation of continuum neutron distribution in $^7$Li(p,n) has been identified as due to the coupling of the $^7$Be breakup levels to the final state of the reaction. The continuum neutron spectra produced by $^7$Li(p,n) reaction has been estimated by measuring the double differential cross sections for continuum and resonant breakup of $^7$Be, through $^7$Li(p,n)$^7$Be$^*$ reaction at 21 MeV…
▽ More
The formation of continuum neutron distribution in $^7$Li(p,n) has been identified as due to the coupling of the $^7$Be breakup levels to the final state of the reaction. The continuum neutron spectra produced by $^7$Li(p,n) reaction has been estimated by measuring the double differential cross sections for continuum and resonant breakup of $^7$Be, through $^7$Li(p,n)$^7$Be$^*$ reaction at 21 MeV of proton energy. The breakup contributions from continuum and $5/2^-$, $7/2^-$ states of $^7$Be have been identified. The measured double differential cross sections have been reproduced through CDCC-CRC calculations. The cross sections were projected to neutron spectrum using Monte-Carlo approach and validated using experimentally measured $^3$He gated neutron spectra. $^7$Li(p,n) neutron spectrum at 20 MeV incident proton energy measured by McNaughton. et al. has been reproduced by adapting estimated model parameters for the reaction.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
A CsI(Tl) detector array for the measurement of light charged particles in heavy-ion reactions
Authors:
P. C. Rout,
V. M. Datar,
D. R. Chakrabarty,
Suresh Kumar,
E. T. Mirgule,
A. Mitra,
V. Nanal,
R. Kujur
Abstract:
An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to $α$-particles from 5 to 40 MeV is measured using radioactive sources and the $^{12}$C($^{12}$C, $α$) reaction populating discrete states in $^{20}$Ne. The energy non-linearity and the c…
▽ More
An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to $α$-particles from 5 to 40 MeV is measured using radioactive sources and the $^{12}$C($^{12}$C, $α$) reaction populating discrete states in $^{20}$Ne. The energy non-linearity and the count rate effect on the pulse shape discrimination property have also been measured and observed the deterioration of pulse shape discrimination with higher count rate.
△ Less
Submitted 17 May, 2017;
originally announced May 2017.
-
Measurement of the response of a liquid scintillation detector to monoenergetic electrons and neutrons
Authors:
P. C. Rout,
A. Gandhi,
T. Basak,
R. G. Thomas,
C. Ghosh,
A. Mitra,
G. Mishra,
S. P. Behera,
R. Kujur,
E. T. Mirgule,
B. K. Nayak,
A. Saxena,
Suresh Kumar,
V. M. Datar
Abstract:
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination…
▽ More
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination and pulse height response of the liquid scintillator for neutrons has been measured using $^7$Li(p,n$_1$)$^7$Be*(0.429 MeV) reaction. Non linear response to mono-energetic neutrons for the liquid scintillator is observed at E$_n$=5.3, 9.0 and 12.7 MeV. The measured response of the liquid scintillator for electrons and neutrons have been compared with Geant4 simulation.
△ Less
Submitted 16 May, 2017;
originally announced May 2017.
-
A large area plastic scintillator detector array for fast neutron measurements
Authors:
P. C. Rout,
D. R. Chakrabarty,
V. M. Datar,
Suresh Kumar,
E. T. Mirgule,
A. Mitra,
V. Nanal,
R. Kujur
Abstract:
A large area plastic scintillator detector array(~ 1 m x1m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using radioactive sources and for mono-energetic neutrons using the 7Li(p,n1)7Be*(0.429 MeV) reaction at proton energies between 6.3 and 19 MeV. A Monte Carlo simulation of t…
▽ More
A large area plastic scintillator detector array(~ 1 m x1m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using radioactive sources and for mono-energetic neutrons using the 7Li(p,n1)7Be*(0.429 MeV) reaction at proton energies between 6.3 and 19 MeV. A Monte Carlo simulation of the energy dependent efficiency of the array for neutron detection is in agreement with the 7Li(p,n1) measurements. The array has been used to measure the neutron spectrum, in the energy range of 4-12 MeV, in the reaction 12C+ 93Nb at E(12C)= 40 MeV. This is in reasonable agreement with a statistical model calculation.
△ Less
Submitted 4 September, 2008;
originally announced September 2008.