-
Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage
Authors:
H. Akatsuka,
T. Andalib,
B. Bell,
J. Berean-Dutcher,
N. Bernier,
C. P. Bidinosti,
C. Cude-Woods,
S. A. Currie,
C. A. Davis,
B. Franke,
R. Gaur,
P. Giampa,
S. Hansen-Romu,
M. T. Hassan,
K. Hatanaka,
T. Higuchi,
C. Gibson,
G. Ichikawa,
I. Ide,
S. Imajo,
T. M. Ito,
B. Jamieson,
S. Kawasaki,
M. Kitaguchi,
W. Klassen
, et al. (29 additional authors not shown)
Abstract:
Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suite…
▽ More
Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $η$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${η=3.5(5)\cdot10^{-4}}$.
△ Less
Submitted 7 February, 2023; v1 submitted 10 August, 2022;
originally announced August 2022.
-
The Precision nEDM Measurement with UltraCold Neutrons at TRIUMF
Authors:
Ryohei Matsumiya,
Hiroaki Akatsuka,
Chris P. Bidinosti,
Charles A. Davis,
Beatrice Franke,
Derek Fujimoto,
Michael T. W. Gericke,
Pietro Giampa,
Robert Golub,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Takashi Higuchi,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Wolfgang Klassen,
Emma Klemets,
Akira Konaka,
Elie Korkmaz,
Ekaterina Korobkina,
Florian Kuchler,
Maedeh Lavvaf
, et al. (23 additional authors not shown)
Abstract:
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using su…
▽ More
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
A Highly Drift-stable Atomic Magnetometer for Fundamental Physics Experiments
Authors:
M. Rosner,
D. Beck,
P. Fierlinger,
H. Filter,
C. Klau,
F. Kuchler,
P. Rößner,
M. Sturm,
D. Wurm,
Z. Sun
Abstract:
We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this is the most stable magnetic field measurement to date. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell-Bloom configuration a hig…
▽ More
We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this is the most stable magnetic field measurement to date. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell-Bloom configuration a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 muT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pum** and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pum** and probing and thus ensures a systematically highly clean measurement. Due to the residual offset of the sensor of < 15 pT together with the cross-talk free operation of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.
△ Less
Submitted 1 February, 2022; v1 submitted 18 January, 2022;
originally announced January 2022.
-
New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection
Authors:
N. Sachdeva,
I. Fan,
E. Babcock,
M. Burghoff,
T. E. Chupp,
S. Degenkolb,
P. Fierlinger,
S. Haude,
E. Kraegeloh,
W. Kilian,
S. Knappe-Grüneberg,
F. Kuchler,
T. Liu,
M. Marino,
J. Meinel,
K. Rolfs,
Z. Salhi,
A. Schnabel,
J. T. Singh,
S. Stuiber,
W. A. Terrano,
L. Trahms,
J. Voigt
Abstract:
We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement camp…
▽ More
We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is $d_A(^{129}\mathrm{Xe}) = (1.4 \pm 6.6_\mathrm{stat} \pm 2.0_\mathrm{syst})\times10^{-28}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 1.4 \times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of five more sensitive than the limit set in 2001.
△ Less
Submitted 26 September, 2019;
originally announced September 2019.
-
A fast-switching magnet serving a spallation-driven ultracold neutron source
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
M. J. Barnes,
B. Bell,
C. P. Bidinosti,
Y. Bylinsky,
J. Chak,
M. Das,
C. A. Davis,
F. Fischer,
B. Franke,
M. T. W. Gericke,
P. Giampa,
M. Hahn,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
K. Katsika,
S. Kawasaki,
T. Kikawa,
W. Klassen,
A. Konaka
, et al. (25 additional authors not shown)
Abstract:
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical oper…
▽ More
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical operation mode of the TRIUMF cyclotron which delivers nearly continuous beam to multiple users. To enable the creation of the UCN facility, a beam-sharing arrangement with another facility was made. The beam sharing is accomplished by the fast-switching (kicker) magnet which is ramped in 50~$μ$s to a current of 193~A, held there for approximately 1~ms, then ramped down in the same short period of time. This achieves a 12~mrad deflection which is sufficient to switch the proton beam between the two facilities. The kicker magnet relies on a high-current, low-inductance coil connected to a fast-switching power supply that is based on insulated-gate bipolar transistors (IGBTs). The design and performance of the kicker magnet system and initial beam delivery results are reported.
△ Less
Submitted 11 August, 2019; v1 submitted 21 May, 2019;
originally announced May 2019.
-
A new measurement of the permanent electric dipole moment of $^{129}$Xe using $^{3}$He comagnetometry and SQUID detection
Authors:
N. Sachdeva,
I. Fan,
E. Babcock,
M. Burghoff,
T. E. Chupp,
S. Degenkolb,
P. Fierlinger,
E. Kraegeloh,
W. Kilian,
S. Knappe-Grüneberg,
F. Kuchler,
T. Liu,
M. Marino,
J. Meinel,
Z. Salhi,
A. Schnabel,
J. T. Singh,
S. Stuiber,
W. A. Terrano,
L. Trahms,
J. Voigt
Abstract:
We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systemat…
▽ More
We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systematic effects is $d_A(^{129}\mathrm{Xe}) = (0.26 \pm 2.33_\mathrm{stat} \pm 0.72_\mathrm{syst})\times10^{-27}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 4.81\times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of 1.4 more sensitive than the previous limit.
△ Less
Submitted 7 February, 2019;
originally announced February 2019.
-
A beamline for fundamental neutron physics at TRIUMF
Authors:
S. Ahmed,
T. Andalib,
M. J. Barnes,
C. B. Bidinosti,
Y. Bylinsky,
J. Chak,
M. Das,
C. A. Davis,
B. Franke,
M. T. W. Gericke,
P. Giampa,
M. Hahn,
S. Hansen-Romu,
K. Hatanaka,
B. Jamieson,
D. Jones,
K. Katsika,
S. Kawasaki,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
L. Kurchaninov,
M. Lang,
L. Lee
, et al. (22 additional authors not shown)
Abstract:
This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has…
▽ More
This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has been successfully commissioned and operated with a beam current up to 10 microA, facilitating first large-scale UCN production in Canada.
△ Less
Submitted 26 December, 2018; v1 submitted 1 October, 2018;
originally announced October 2018.
-
First ultracold neutrons produced at TRIUMF
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
B. Bell,
C. P. Bidinosti,
E. Cudmore,
M. Das,
C. A. Davis,
B. Franke,
M. Gericke,
P. Giampa,
P. Gnyp,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
S. Kawasaki,
T. Kikawa,
M. Kitaguchi,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
M. Lang
, et al. (28 additional authors not shown)
Abstract:
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this so…
▽ More
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.
△ Less
Submitted 16 December, 2018; v1 submitted 10 September, 2018;
originally announced September 2018.
-
Frequency shifts in noble-gas magnetometers
Authors:
William A. Terrano,
Jonas Meinel,
Natasha Sachdeva,
Timothy E. Chupp,
Skyler Degenkolb,
Peter Fierlinger,
Florian Kuchler,
Jaideep T. Singh
Abstract:
Polarized nuclei are a powerful tool in nuclear spin studies and in searches for beyond-the-standard model physics. Noble-gas comagnetometer systems, which compare two nuclear species, have thus far been limited by anomalous frequency variations of unknown origin. We studied the self-interactions in a $^3$He-$^{129}$Xe system by independently addressing, controlling and measuring the influence of…
▽ More
Polarized nuclei are a powerful tool in nuclear spin studies and in searches for beyond-the-standard model physics. Noble-gas comagnetometer systems, which compare two nuclear species, have thus far been limited by anomalous frequency variations of unknown origin. We studied the self-interactions in a $^3$He-$^{129}$Xe system by independently addressing, controlling and measuring the influence of each component of the nuclear spin polarization. Our results directly rule out prior explanations of the shifts, and demonstrate experimentally that they can be explained by species dependent self-interactions. We also report the first gas phase frequency shift induced by $^{129}$Xe on $^3$He.
△ Less
Submitted 8 February, 2019; v1 submitted 29 July, 2018;
originally announced July 2018.
-
A large-scale magnetic shield with 10^6 dam** at mHz frequencies
Authors:
I. Altarev,
M. Bales,
D. H. Beck,
T. Chupp,
K. Fierlinger,
P. Fierlinger,
F. Kuchler,
T. Lins,
M. G. Marino,
B. Niessen,
G. Petzoldt,
J. T. Singh,
U. Schläpfer,
A. Schnabel,
R. Stoepler,
S. Stuiber,
M. Strum,
B. Taubenheim,
J. Voigt
Abstract:
We present a magnetically shielded environment with a dam** factor larger than one million at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an improvement of the state of the art in dam** the difficult regime of very low-frequency distortions by more than an order of magnitude. This technology enabl…
▽ More
We present a magnetically shielded environment with a dam** factor larger than one million at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an improvement of the state of the art in dam** the difficult regime of very low-frequency distortions by more than an order of magnitude. This technology enables a new generation of high precision measurements in fundamental physics and metrology, including searches for new physics far beyond the reach of accelerator-based experiments. We discuss the technical realization of the shield with its improvements in design.
△ Less
Submitted 23 May, 2015; v1 submitted 30 January, 2015;
originally announced January 2015.
-
A magnetically shielded room with ultra low residual field and gradient
Authors:
I. Altarev,
E. Babcock,
D. Beck,
M. Burghoff,
S. Chesnevskaya,
T. Chupp,
S. Degenkolb,
I. Fan,
P. Fierlinger,
A. Frei,
E. Gutsmiedl,
S. Knappe-Grüneberg,
F. Kuchler,
T. Lauer,
P. Link,
T. Lins,
M. Marino,
J. McAndrew,
B. Niessen,
S. Paul,
G. Petzoldt,
U. Schläpfer,
A. Schnabel,
S. Sharma,
J. Singh
, et al. (7 additional authors not shown)
Abstract:
A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental p…
▽ More
A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus.
△ Less
Submitted 24 March, 2014;
originally announced March 2014.
-
New constraints on Lorentz invariance violation from the neutron electric dipole moment
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
P. G. Harris,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
A. Kozela,
F. Kuchler,
B. Lauss,
T. Lefort,
Y. Lemière
, et al. (18 additional authors not shown)
Abstract:
We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrai…
▽ More
We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrain such a modulation to $d_{12} < 15 \times 10^{-25} \ e\,{\rm cm}$ and $d_{24} < 10 \times 10^{-25} \ e\,{\rm cm}$ at 95~\% C.L. The result translates into a limit on the energy scale for this type of Lorentz violation effect at the level of ${\cal E}_{LV} > 10^{10}$~GeV.
△ Less
Submitted 25 June, 2010;
originally announced June 2010.
-
Neutron to Mirror-Neutron Oscillations in the Presence of Mirror Magnetic Fields
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
K. Bodek,
M. Daum,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
E. Gutsmiedl,
P. G. Harris,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
P. Knowles,
A. Kozela,
F. Kuchler,
M. Kuźniak,
T. Lauer,
B. Lauss
, et al. (21 additional authors not shown)
Abstract:
We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 1…
▽ More
We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 12.0 s at 95% C.L. for any B' between 0 and 12.5 uT.
△ Less
Submitted 18 August, 2009; v1 submitted 26 May, 2009;
originally announced May 2009.
-
Test of Lorentz invariance with spin precession of ultracold neutrons
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
E. Gutsmiedl,
P. G. Harris,
W. Heil,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
P. Knowles,
A. Kozela,
F. Kuchler,
M. Kuźniak
, et al. (21 additional authors not shown)
Abstract:
A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This resu…
▽ More
A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron $|g_n| < 0.3 $eV/$c^2$ m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit $|g_n| < 3 \times 10^{-4} $eV/$c^2 $m.
△ Less
Submitted 23 July, 2009; v1 submitted 20 May, 2009;
originally announced May 2009.