-
Photothermal gas detection using a miniaturized fiber Fabry-Perot cavity
Authors:
Karol Krzempek,
Piotr Jaworski,
Lukas Tenbrake,
Florian Giefer,
Dieter Meschede,
Sebastian Hofferberth,
Hannes Pfeifer
Abstract:
We demonstrate a robust and miniaturized fiber Fabry-Perot cavity-based sensor for photothermal spectroscopic signal retrieval. The proof-of-concept experiment involved the use of a near-infrared pump laser to detect methane molecules on an isolated overtone 2.3 R(4) transition located at 6057.1 cm-1. The photothermal-related modulation of the gas refractive index was induced at the center of the…
▽ More
We demonstrate a robust and miniaturized fiber Fabry-Perot cavity-based sensor for photothermal spectroscopic signal retrieval. The proof-of-concept experiment involved the use of a near-infrared pump laser to detect methane molecules on an isolated overtone 2.3 R(4) transition located at 6057.1 cm-1. The photothermal-related modulation of the gas refractive index was induced at the center of the interferometer, which was filled with the sample. Subsequently, the phase change of the resonating probe beam was measured as a shift in the reflected beam intensity, which was proportional to the methane concentration. A normalized noise equivalent absorption coefficient of 7.06 x 10-8 cm-1 W Hz-1/2 was achieved, suggesting significant potential for the design of small and versatile gas detectors with excellent detectivity. We discuss future improvements of the proposed photothermal gas detection approach.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.
-
Optical frequency comb Fourier transform spectroscopy of formaldehyde in the 1250 to 1390 cm$^{-1}$ range: experimental line list and improved MARVEL analysis
Authors:
Matthias Germann,
Adrian Hjältén,
Jonathan Tennyson,
Sergei N. Yurchenko,
Iouli E. Gordon,
Christian Pett,
Isak Silander,
Karol Krzempek,
Arkadiusz Hudzikowski,
Aleksander Głuszek,
Grzegorz Soboń,
Aleksandra Foltynowicz
Abstract:
We use optical frequency comb Fourier transform spectroscopy to record high-resolution, low-pressure, room-temperature spectra of formaldehyde (H$_2$$^{12}$C$^{16}$O) in the range of 1250 to 1390 cm$^{-1}$. Through line-by-line fitting, we retrieve line positions and intensities of 747 rovibrational transitions: 558 from the $ν_6$ band, 129 from the $ν_4$ band, and 14 from the $ν_3$ band, as well…
▽ More
We use optical frequency comb Fourier transform spectroscopy to record high-resolution, low-pressure, room-temperature spectra of formaldehyde (H$_2$$^{12}$C$^{16}$O) in the range of 1250 to 1390 cm$^{-1}$. Through line-by-line fitting, we retrieve line positions and intensities of 747 rovibrational transitions: 558 from the $ν_6$ band, 129 from the $ν_4$ band, and 14 from the $ν_3$ band, as well as 46 from four different hot bands. We incorporate the accurate and precise line positions (0.4 MHz median uncertainty) into the MARVEL (measured active vibration-rotation energy levels) analysis of the H$_2$CO spectrum. This increases the number of MARVEL-predicted energy levels by 82 and of rovibrational transitions by 5382, and substantially reduces uncertainties of MARVEL-derived H$_2$CO energy levels over a large range: from pure rotational levels below 200 cm$^{-1}$ up to multiply excited vibrational levels at 6000 cm$^{-1}$. This work is an important step toward filling the gaps in formaldehyde data in the HITRAN database.
△ Less
Submitted 5 October, 2023; v1 submitted 21 June, 2023;
originally announced June 2023.
-
A methane line list with sub-MHz accuracy in the 1250 to 1380 cm-1 range from optical frequency comb Fourier transform spectroscopy
Authors:
Matthias Germann,
Adrian Hjältén,
Vincent Boudon,
Cyril Richard,
Karol Krzempek,
Arkadiusz Hudzikowski,
Aleksander Głuszek,
Grzegorz Soboń,
Aleksandra Foltynowicz
Abstract:
We use a Fourier transform spectrometer based on a difference frequency generation optical frequency comb to measure high-resolution, low-pressure, room-temperature spectra of methane in the 1250 - 1380 cm$^{-1}$ range. From these spectra, we retrieve line positions and intensities of 678 lines of two isotopologues: 157 lines from the $^{12}$CH${_4}$ $ν$${_4}$ fundamental band, 131 lines from the…
▽ More
We use a Fourier transform spectrometer based on a difference frequency generation optical frequency comb to measure high-resolution, low-pressure, room-temperature spectra of methane in the 1250 - 1380 cm$^{-1}$ range. From these spectra, we retrieve line positions and intensities of 678 lines of two isotopologues: 157 lines from the $^{12}$CH${_4}$ $ν$${_4}$ fundamental band, 131 lines from the $^{13}$CH${_4}$ $ν$${_4}$ fundamental band, as well as 390 lines from two $^{12}$CH${_4}$ hot bands, $ν$${_2}$ + $ν$${_4}$ - $ν$${_2}$ and 2$ν$${_4}$ - $ν$${_4}$. For another 165 lines from the $^{12}$CH${_4}$ $ν$${_4}$ fundamental band we retrieve line positions only. The uncertainties of the line positions range from 0.19 to 2.3 MHz, and their median value is reduced by a factor of 18 and 59 compared to the previously available data for the $^{12}$CH${_4}$ fundamental and hot bands, respectively, obtained from conventional FTIR absorption measurements. The new line positions are included in the global models of the spectrum of both methane isotopologues, and the fit residuals are reduced by a factor of 8 compared to previous absorption data, and 20 compared to emission data. The experimental line intensities have relative uncertainties in the range of 1.5 - 7.7%, similar to those in the previously available data; 235 new $^{12}$CH${_4}$ line intensities are included in the global model.
△ Less
Submitted 13 April, 2022;
originally announced April 2022.
-
Optical Frequency Comb Fourier Transform Spectroscopy of $^{14}$N$_2$$^{16}$O at 7.8 μm
Authors:
Adrian Hjältén,
Matthias Germann,
Karol Krzempek,
Arkadiusz Hudzikowski,
Aleksander Głuszek,
Dorota Tomaszewska,
Grzegorz Soboń,
Aleksandra Foltynowicz
Abstract:
We use a Fourier transform spectrometer based on a compact mid-infrared difference frequency generation comb source to perform broadband high-resolution measurements of nitrous oxide, $^{14}$N$_2$$^{16}$O, and retrieve line center frequencies of the $ν$$_1$ fundamental band and the $ν$$_1$ + $ν$$_2$ - $ν$$_2$ hot band. The spectrum spans 90 cm$^{-1}$ around 1285 cm$^{-1}$ with a sample point spaci…
▽ More
We use a Fourier transform spectrometer based on a compact mid-infrared difference frequency generation comb source to perform broadband high-resolution measurements of nitrous oxide, $^{14}$N$_2$$^{16}$O, and retrieve line center frequencies of the $ν$$_1$ fundamental band and the $ν$$_1$ + $ν$$_2$ - $ν$$_2$ hot band. The spectrum spans 90 cm$^{-1}$ around 1285 cm$^{-1}$ with a sample point spacing of 3 ${\times}$ 10$^{-4}$ cm$^{-1}$ (9 MHz). We report line positions of 72 lines in the $ν$$_1$ fundamental band between P(37) and R(38), and 112 lines in the $ν$$_1$ + $ν$$_2$ - $ν$$_2$ hot band (split into two components with e/f rotationless parity) between P(34) and R(33), with uncertainties in the range of 90-600 kHz. We derive upper state constants of both bands from a fit of the effective ro-vibrational Hamiltonian to the line center positions. For the fundamental band, we observe excellent agreement in the retrieved line positions and upper state constants with those reported in a recent study by AlSaif et al. using a comb-referenced quantum cascade laser [J Quant Spectrosc Radiat Transf, 2018;211:172-178]. We determine the origin of the hot band with precision one order of magnitude better than previous work based on FTIR measurements by Toth [http://mark4sun.jpl.nasa.gov/n2o.html], which is the source of the HITRAN2016 data for these bands.
△ Less
Submitted 4 May, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.