-
Structure Studies of $^{13}\text{Be}$ from the $^{12}$Be(d,p) reaction in inverse kinematics on a solid deuteron target
Authors:
J. Kovoor,
K. L. Jones,
J. Hooker,
M. Vostinar,
R. Kanungo,
S. D. Pain,
M. Alcorta,
J. Allen,
C. Andreoiu,
L. Atar,
D. W. Bardayan,
S. S. Bhattacharjee,
D. Blankstein,
C. Burbadge,
S. Burcher,
W. N. Catford,
S. Cha,
K. Chae,
D. Connolly,
B. Davids,
N. E. Esker,
F. H. Garcia,
S. Gillespie,
R. Ghimire,
A. Gula
, et al. (20 additional authors not shown)
Abstract:
The low-lying structure of $^{13}$Be has remained an enigma for decades. Despite numerous experimental and theoretical studies, large inconsistencies remain. Being both unbound, and one neutron away from $^{14}$Be, the heaviest bound beryllium nucleus, $^{13}$Be is difficult to study through simple reactions with weak radioactive ion beams or more complex reactions with stable-ion beams. Here, we…
▽ More
The low-lying structure of $^{13}$Be has remained an enigma for decades. Despite numerous experimental and theoretical studies, large inconsistencies remain. Being both unbound, and one neutron away from $^{14}$Be, the heaviest bound beryllium nucleus, $^{13}$Be is difficult to study through simple reactions with weak radioactive ion beams or more complex reactions with stable-ion beams. Here, we present the results of a study using the $^{12}$Be(d,p)$^{13}$Be reaction in inverse kinematics using a 9.5~MeV per nucleon $^{12}$Be beam from the ISAC-II facility. The solid deuteron target of IRIS was used to achieve an increased areal thickness compared to conventional deuterated polyethylene targets. The Q-value spectrum below -4.4~MeV was analyzed using a Bayesian method with GEANT4 simulations. A three-point angular distribution with the same Q-value gate was fit with a mixture of $s$- and $p$-wave, $s$- and $d$-wave, or pure $p$-wave transfer. The Q-value spectrum was also compared with GEANT simulations obtained using the energies and widths of states reported in four previous works. It was found that our results are incompatible with works that revealed a wide $5/2^+$ resonance but shows better agreement with ones that reported a narrower width.
△ Less
Submitted 15 September, 2023;
originally announced September 2023.
-
Decay Spectroscopy of $^{160}$Eu: Quasiparticle Configurations of Excited States and Structure of $K^π$=$4^+$ Band-heads in $^{160}$Gd
Authors:
D. Yates,
R. Kruecken,
I. Dillmann,
P. E. Garrett,
B. Olaizola,
V. Vedia,
F. A. Ali,
C. Andreoiu,
W. Ashfield,
G. C. Ball,
Z. Beadle,
N. Bernier,
S. S. Bhattacharjee,
H. Bidaman,
V. Bildstein,
D. Bishop,
M. Bowry,
C. Burbadge,
R. Caballero-Folch,
D. Z. Chaney,
D. C. Cross,
A. Diaz Varela,
M. R. Dunlop,
R. Dunlop,
L. J. Evitts
, et al. (23 additional authors not shown)
Abstract:
\noindent \textbf{Background:} Detailed spectroscopy of neutron-rich, heavy, deformed nuclei is of broad interest for nuclear astrophysics and nuclear structure. Nuclei in the r-process path and following freeze-out region impact the resulting r-process abundance distribution, and the structure of nuclei midshell in both proton and neutron number helps to understand the evolution of subshell gaps…
▽ More
\noindent \textbf{Background:} Detailed spectroscopy of neutron-rich, heavy, deformed nuclei is of broad interest for nuclear astrophysics and nuclear structure. Nuclei in the r-process path and following freeze-out region impact the resulting r-process abundance distribution, and the structure of nuclei midshell in both proton and neutron number helps to understand the evolution of subshell gaps and large deformation in these nuclei.
\noindent \textbf{Purpose:} To improve the understanding of the nuclear structure of $^{160}$Gd, specifically the $K^π$=$4^+$ bands, as well as study the $β$-decay of $^{160}$Eu into $^{160}$Gd.
\noindent \textbf{Methods:} High-statistics decay spectroscopy of $^{160}$Gd resulting from the $β$-decay of $^{160}$Eu was collected using the GRIFFIN spectrometer at the TRIUMF-ISAC facility.
\noindent \textbf{Results:} Two new excited states and ten new transitions were observed in $^{160}$Gd. The $β$-decaying half-lives of the low- and high-spin isomer in $^{160}$Eu were determined, and the low-spin state's half-life was measured to be $t_{1/2}=26.0(8)$~s, $\sim$16\% shorter than previous measurements. Lifetimes of the two $K^π$=$4^+$ band-heads in $^{160}$Gd were measured for the first time, as well as $γ$-$γ$ angular correlations and mixing ratios of intense transitions out of those band-heads.
\noindent \textbf{Conclusions:} Lifetimes and mixing ratios suggest that the hexadecapole phonon model of the $K^π$=$4^+$ band-heads in $^{160}$Gd is preferred over a simple two-state strong mixing scenario, although further theoretical calculations are needed to fully understand these states. Additionally, the 1999.0 keV state in $^{160}$Gd heavily populated in $β$-decay is shown to have positive parity, which raises questions regarding the structure of the high-spin $β$-decaying state in $^{160}$Eu.
△ Less
Submitted 18 May, 2023;
originally announced May 2023.
-
Uncertainty Quantification of Mass Models using Ensemble Bayesian Model Averaging
Authors:
Yukiya Saito,
Iris Dillmann,
Reiner Kruecken,
Matthew R. Mumpower,
Rebecca Surman
Abstract:
Developments in the description of the masses of atomic nuclei have led to various nuclear mass models that provide predictions for masses across the whole chart of nuclides. These mass models play an important role in understanding the synthesis of heavy elements in the rapid neutron capture ($r$-) process. However, it is still a challenging task to estimate the size of uncertainty associated wit…
▽ More
Developments in the description of the masses of atomic nuclei have led to various nuclear mass models that provide predictions for masses across the whole chart of nuclides. These mass models play an important role in understanding the synthesis of heavy elements in the rapid neutron capture ($r$-) process. However, it is still a challenging task to estimate the size of uncertainty associated with the predictions of each mass model. In this work, a method to quantify the mass uncertainty using \textit{ensemble Bayesian model averaging} (EBMA) is introduced. This Bayesian method provides a natural way to perform model averaging, selection, calibration, and uncertainty quantification, by combining the mass models as a mixture of normal distributions, whose parameters are optimized against the experimental data, employing the Markov chain Monte Carlo (MCMC) method using the No-U-Turn sampler (NUTS). The average size of our best uncertainty estimates of neutron separation energies based on the AME2003 data is 0.48 MeV and covers 95% of new data in the AME2020. The uncertainty estimates can also be used to detect outliers with respect to the trend of experimental data and theoretical predictions.
△ Less
Submitted 27 February, 2024; v1 submitted 2 May, 2023;
originally announced May 2023.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Fundamental Symmetries, Neutrons, and Neutrinos (FSNN): Whitepaper for the 2023 NSAC Long Range Plan
Authors:
B. Acharya,
C. Adams,
A. A. Aleksandrova,
K. Alfonso,
P. An,
S. Baeßler,
A. B. Balantekin,
P. S. Barbeau,
F. Bellini,
V. Bellini,
R. S. Beminiwattha,
J. C. Bernauer,
T. Bhattacharya,
M. Bishof,
A. E. Bolotnikov,
P. A. Breur,
M. Brodeur,
J. P. Brodsky,
L. J. Broussard,
T. Brunner,
D. P. Burdette,
J. Caylor,
M. Chiu,
V. Cirigliano,
J. A. Clark
, et al. (154 additional authors not shown)
Abstract:
This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recom…
▽ More
This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recommendations and justifies them in detail.
△ Less
Submitted 6 April, 2023;
originally announced April 2023.
-
Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200
Authors:
S. Li,
I. Ostrovskiy,
Z. Li,
L. Yang,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian
, et al. (65 additional authors not shown)
Abstract:
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial N…
▽ More
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.
△ Less
Submitted 8 May, 2023; v1 submitted 11 March, 2023;
originally announced March 2023.
-
Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the additio…
▽ More
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2νββ$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2νββ$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2ν}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.
△ Less
Submitted 16 October, 2023; v1 submitted 2 March, 2023;
originally announced March 2023.
-
Neutrinoless Double Beta Decay
Authors:
C. Adams,
K. Alfonso,
C. Andreoiu,
E. Angelico,
I. J. Arnquist,
J. A. A. Asaadi,
F. T. Avignone,
S. N. Axani,
A. S. Barabash,
P. S. Barbeau,
L. Baudis,
F. Bellini,
M. Beretta,
T. Bhatta,
V. Biancacci,
M. Biassoni,
E. Bossio,
P. A. Breur,
J. P. Brodsky,
C. Brofferio,
E. Brown,
R. Brugnera,
T. Brunner,
N. Burlac,
E. Caden
, et al. (207 additional authors not shown)
Abstract:
This White Paper, prepared for the Fundamental Symmetries, Neutrons, and Neutrinos Town Meeting related to the 2023 Nuclear Physics Long Range Plan, makes the case for double beta decay as a critical component of the future nuclear physics program. The major experimental collaborations and many theorists have endorsed this white paper.
This White Paper, prepared for the Fundamental Symmetries, Neutrons, and Neutrinos Town Meeting related to the 2023 Nuclear Physics Long Range Plan, makes the case for double beta decay as a critical component of the future nuclear physics program. The major experimental collaborations and many theorists have endorsed this white paper.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Search for MeV Electron Recoils from Dark Matter in EXO-200
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total…
▽ More
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.
△ Less
Submitted 20 February, 2023; v1 submitted 2 July, 2022;
originally announced July 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
Use of Bayesian Optimization to Understand the Structure of Nuclei
Authors:
J. Hooker,
J. Kovoor,
K. L. Jones,
R. Kanungo,
M. Alcorta,
J. Allen,
C. Andreoiu,
L. Atar,
D. W. Bardayan,
S. S. Bhattacharjee,
D. Blankstein,
C. Burbadge,
S. Burcher,
W. N. Catford,
S. Cha,
K. Chae,
D. Connolly,
B. Davids,
N. Esker,
F. H. Garcia,
S. Gillespie,
R. Ghimire,
A. Gula,
G. Hackman,
S. Hallam
, et al. (19 additional authors not shown)
Abstract:
Monte Carlo simulations are widely used in nuclear physics to model experimental systems. In cases where there are significant unknown quantities, such as energies of states, an iterative process of simulating and fitting is often required to describe experimental data. We describe a Bayesian approach to fitting experimental data, designed for data from a $^{12}$Be(d,p) reaction measurement, using…
▽ More
Monte Carlo simulations are widely used in nuclear physics to model experimental systems. In cases where there are significant unknown quantities, such as energies of states, an iterative process of simulating and fitting is often required to describe experimental data. We describe a Bayesian approach to fitting experimental data, designed for data from a $^{12}$Be(d,p) reaction measurement, using simulations made with GEANT4. Q-values from the $^{12}$C(d,p) reaction to well-known states in $^{13}$C are compared with simulations using BayesOpt. The energies of the states were not included in the simulation to reproduce the situation for $^{13}$Be where the states are poorly known. Both cases had low statistics and significant resolution broadening owing to large proton energy losses in the solid deuterium target. Excitation energies of the lowest three excited states in $^{13}$C were extracted to better than 90 keV, paving a way for extracting information on $^{13}$Be.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Proton inelastic scattering reveals deformation in $^8$He
Authors:
M. Holl,
R. Kanungo,
Z. H. Sun,
G. Hagen,
J. A. Lay,
A. M. Moro,
P. Navrátil,
T. Papenbrock,
M. Alcorta,
D. Connolly,
B. Davids,
A. Diaz Varela,
M. Gennari,
G. Hackman,
J. Henderson,
S. Ishimoto,
A. I. Kilic,
R. Krücken,
A. Lennarz,
J. Liang,
J. Measures,
W. Mittig,
O. Paetkau,
A. Psaltis,
S. Quaglioni
, et al. (5 additional authors not shown)
Abstract:
A measurement of proton inelastic scattering of $^8$He at $8.25A$~MeV at TRIUMF shows a resonance at 3.54(6)~MeV with a width of 0.89(11)~MeV. The energy of the state is in good agreement with coupled cluster and no-core shell model with continuum calculations, with the latter successfully describing the measured resonance width as well. Its differential cross section analyzed with phenomenologica…
▽ More
A measurement of proton inelastic scattering of $^8$He at $8.25A$~MeV at TRIUMF shows a resonance at 3.54(6)~MeV with a width of 0.89(11)~MeV. The energy of the state is in good agreement with coupled cluster and no-core shell model with continuum calculations, with the latter successfully describing the measured resonance width as well. Its differential cross section analyzed with phenomenological collective excitation form factor and microscopic coupled reaction channels framework consistently reveals a large deformation parameter $β_2$ = 0.40(3), consistent with no-core shell model predictions of a large neutron deformation. This deformed double-closed shell at the neutron drip-line opens a new paradigm.
△ Less
Submitted 4 October, 2021;
originally announced October 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
First direct measurement of $^{59}$Cu(p,$α$)$^{56}$Ni: A step towards constraining the Ni-Cu cycle in the Cosmos
Authors:
J. S. Randhawa,
R. Kanungo,
J. Refsgaard,
P. Mohr,
T. Ahn,
M. Alcorta,
C. Andreoiu,
S. S. Bhattacharjee,
B. Davids,
G. Christian,
A. A. Chen,
R. Coleman,
P. Garrett,
G. F. Grinyer,
E. Gyabeng Fuakye,
G. Hackman,
R. Jain,
K. Kapoor,
R. Krücken,
A. Laffoley,
A. Lennarz,
J. Liang,
Z. Meisel,
N. Nikhil,
A. Psaltis
, et al. (12 additional authors not shown)
Abstract:
Reactions on the proton-rich nuclides drive the nucleosynthesis in Core-Collapse Supernovae (CCSNe) and in X-ray bursts (XRBs). CCSNe eject the nucleosynthesis products to the interstellar medium and hence are a potential inventory of p-nuclei, whereas in XRBs nucleosynthesis powers the light curves. In both astrophysical sites the Ni-Cu cycle, which features a competition between $^{59}$Cu(p,$α$)…
▽ More
Reactions on the proton-rich nuclides drive the nucleosynthesis in Core-Collapse Supernovae (CCSNe) and in X-ray bursts (XRBs). CCSNe eject the nucleosynthesis products to the interstellar medium and hence are a potential inventory of p-nuclei, whereas in XRBs nucleosynthesis powers the light curves. In both astrophysical sites the Ni-Cu cycle, which features a competition between $^{59}$Cu(p,$α$)$^{56}$Ni and $^{59}$Cu(p,$γ$)$^{60}$Zn, could potentially halt the production of heavier elements. Here, we report the first direct measurement of $^{59}$Cu(p,$α$)$^{56}$Ni using a re-accelerated $^{59}$Cu beam and cryogenic solid hydrogen target. Our results show that the reaction proceeds predominantly to the ground state of $^{56}$Ni and the experimental rate has been found to be lower than Hauser-Feshbach-based statistical predictions. New results hint that the $νp$-process could operate at higher temperatures than previously inferred and therefore remains a viable site for synthesizing the heavier elements.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
Single-particle structure in neutron-rich Sr isotopes approaching the N = 60 shape transition
Authors:
S. Cruz,
K. Wimmer,
S. S. Bhattacharjee,
P. C. Bender,
G. Hackman,
R. Krücken,
F. Ames,
C. Andreoiu,
R. A. E. Austin,
C. S. Bancroft,
R. Braid,
T. Bruhn,
W. N. Catford,
A. Cheeseman,
A. Chester,
D. S. Cross,
C. Aa. Diget,
T. Drake,
A. B. Garnsworthy,
R. Kanungo,
A. Knapton,
W. Korten,
K. Kuhn,
J. Lassen,
R. Laxdal
, et al. (11 additional authors not shown)
Abstract:
Background: Neutron-rich nuclei around neutron number N = 60 show a dramatic shape transition from spherical ground states to prolate deformation in 98Sr and heavier nuclei. Purpose: The purpose of this study is to investigate the single-particle structure approaching the shape transitional region. Method: The level structures of neutron-rich 93,94,95Sr were studied via the d(94,95,96Sr,t) one-neu…
▽ More
Background: Neutron-rich nuclei around neutron number N = 60 show a dramatic shape transition from spherical ground states to prolate deformation in 98Sr and heavier nuclei. Purpose: The purpose of this study is to investigate the single-particle structure approaching the shape transitional region. Method: The level structures of neutron-rich 93,94,95Sr were studied via the d(94,95,96Sr,t) one-neutron strip** reactions at TRIUMF using a beam energy of 5.5 AMeV. γ-rays emitted from excited states and recoiling charged particles were detected by using the TIGRESS and SHARC arrays, respectively. States were identified by gating on the excitation energy and, if possible, the coincident γ radiation. Results: Triton angular distributions for the reactions populating states in ejectile nuclei 93,94,95Sr were compared with distorted wave Born approximation calculations to assign and revise spin and parity quantum numbers and extract spectroscopic factors. The results were compared with shell model calculations and the reverse (d,p) reactions and good agreement was obtained. Conclusions: The results for the d(94Sr,t)93Sr and d(95Sr,t)94Sr reactions are in good agreement with shell model calculations. A two level mixing analysis for the 0+ states in 94Sr suggest strong mixing of two shapes. For the d(96Sr,t)95Sr reaction the agreement with the shell model is less good. The configuration of the ground state of 96Sr is already more complex than predicted, and therefore indications for the shape transition can already be observed before N = 60.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
Decay Spectroscopy of $^{129}$Cd
Authors:
Y. Saito,
I. Dillmann,
R. Krücken,
N. Bernier,
G. C. Ball,
M. Bowry,
C. Andreoiu,
H. Bidaman,
V. Bildstein,
P. Boubel,
C. Burbadge,
R. Caballero-Folch,
M. R. Dunlop,
R. Dunlop,
L. J. Evitts,
F. H. Garcia,
A. B. Garnsworthy,
P. E. Garrett,
H. Grawe,
G. Hackman,
S. Hallam,
J. Henderson,
S. Ilyushkin,
A. Jungclaus,
D. Kisliuk
, et al. (20 additional authors not shown)
Abstract:
Excited states of $^{129}$In populated following the $β$-decay of $^{129}$Cd were experimentally studied with the GRIFFIN spectrometer at the ISAC facility of TRIUMF, Canada. A 480-MeV proton beam was im**ed on a uranium carbide target and $^{129}$Cd was extracted using the Ion Guide Laser Ion Source (IG-LIS). $β$- and $γ$-rays following the decay of $^{129}$Cd were detected with the GRIFFIN spe…
▽ More
Excited states of $^{129}$In populated following the $β$-decay of $^{129}$Cd were experimentally studied with the GRIFFIN spectrometer at the ISAC facility of TRIUMF, Canada. A 480-MeV proton beam was im**ed on a uranium carbide target and $^{129}$Cd was extracted using the Ion Guide Laser Ion Source (IG-LIS). $β$- and $γ$-rays following the decay of $^{129}$Cd were detected with the GRIFFIN spectrometer comprising the plastic scintillator SCEPTAR and 16 high-purity germanium (HPGe) clover-type detectors. %, along with the $β$-particles were detected with SCEPTAR. From the $β$-$γ$-$γ$ coincidence analysis, 32 new transitions and 7 new excited states were established, expanding the previously known level scheme of $^{129}$In. The $\log ft$ values deduced from the $β$-feeding intensities suggest that some of the high-lying states were populated by the $ν0 g_{7/2} \rightarrow π0 g_{9/2}$ allowed Gamow-Teller (GT) transition, which indicates that the allowed GT transition is more dominant in the $^{129}$Cd decay than previously reported. Observation of fragmented Gamow-Teller strengths is consistent with theoretical calculations.
△ Less
Submitted 6 August, 2020;
originally announced August 2020.
-
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic
Authors:
C. Galbiati,
A. Abba,
P. Agnes,
P. Amaudruz,
M. Arba,
F. Ardellier-Desages,
C. Badia,
G. Batignani,
G. Bellani,
G. Bianchi,
D. Bishop,
V. Bocci,
W. Bonivento,
B. Bottino,
M. Bouchard,
S. Brice,
G. Buccino,
S. Bussino,
A. Caminata,
A. Capra,
M. Caravati,
M. Carlini,
L. Carrozzi,
J. M. Cela,
B. Celano
, et al. (123 additional authors not shown)
Abstract:
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equ…
▽ More
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.
△ Less
Submitted 10 April, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.
-
Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory
Authors:
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (83 additional authors not shown)
Abstract:
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source d…
▽ More
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.
△ Less
Submitted 7 May, 2020; v1 submitted 31 January, 2020;
originally announced February 2020.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Single-Particle Structure of Neutron-Rich Sr Isotopes Via d( 94,95,96 Sr, p) Reactions
Authors:
S. Cruz,
K. Wimmer,
P. C. Bender,
R. Krücken,
G. Hackman,
F. Ames,
C. Andreoiu,
R. A. E. Austin,
C. S. Bancroft,
R. Braid,
T. Bruhn,
W. N. Catford,
A. Cheeseman,
A. Chester,
D. S. Cross,
C. Aa. Diget,
T. Drake,
A. B. Garnsworthy,
R. Kanungo,
A. Knapton,
W. Korten,
K. Kuhn,
J. Lassen,
R. Laxdal,
M. Marchetto
, et al. (10 additional authors not shown)
Abstract:
The region around neutron number N = 60 in the neutron-rich Sr and Zr nuclei is one of the most dramatic examples of a ground state shape transition from (near) spherical below N = 60 to strongly deformed shapes in the heavier isotopes. The single-particle structure of 95-97Sr approaching the ground state shape transition at 98 Sr has been investigated via single-neutron transfer reactions using t…
▽ More
The region around neutron number N = 60 in the neutron-rich Sr and Zr nuclei is one of the most dramatic examples of a ground state shape transition from (near) spherical below N = 60 to strongly deformed shapes in the heavier isotopes. The single-particle structure of 95-97Sr approaching the ground state shape transition at 98 Sr has been investigated via single-neutron transfer reactions using the (d, p) reaction in inverse kinematics. These reactions selectively populate states with a large overlap of the projectile ground state coupled to a neutron in a single-particle orbital. Radioactive 94,95,96Sr nuclei with energies of 5.5 AMeV were used to bombard a CD 2 target. Recoiling light charged particles and γ rays were detected using a quasi-4π silicon strip detector array and a 12 element Ge array. The excitation energy of states populated was reconstructed employing the missing mass method combined with γ-ray tagging and differential cross sections for final states were extracted. A reaction model analysis of the angular distributions allowed for firm spin assignments to be made for the low-lying 352, 556 and 681 keV excited states in 95Sr and a constraint has been placed on the spin of the higher-lying 1666 keV state. Angular distributions have been extracted for 10 states populated in the d(95Sr,p)96Sr reaction, and constraints have been provided for the spins and parities of several final states. Results are compared to shell model calculations in several model spaces and the structure of low-lying states in 94Sr and 95Sr is well-described. The spectroscopic strength of the 0+ and 2 states in 96Sr is significantly more fragmented than predicted.
△ Less
Submitted 2 November, 2019;
originally announced November 2019.
-
LRP2020: The cosmic origin and evolution of the elements
Authors:
Rodrigo Fernández,
Falk Herwig,
Samar Safi-Harb,
Iris Dillmann,
Kim A. Venn,
Benoit Côté,
Craig O. Heinke,
Erik Rosolowsky,
Tyrone E. Woods,
Daryl Haggard,
Luis Lehner,
John J. Ruan,
Daniel M. Siegel,
Jo Bovy,
Alan A. Chen,
Andrew Cumming,
Barry Davids,
Maria R. Drout,
Reiner Krüecken
Abstract:
The origin of many elements of the periodic table remains an unsolved problem. While many nucleosynthetic channels are broadly understood, significant uncertainties remain regarding certain groups of elements such as the intermediate and rapid neutron-capture processes, the p-process, or the origin of odd-Z elements in the most metal-poor stars. Canada has a long tradition of leadership in nuclear…
▽ More
The origin of many elements of the periodic table remains an unsolved problem. While many nucleosynthetic channels are broadly understood, significant uncertainties remain regarding certain groups of elements such as the intermediate and rapid neutron-capture processes, the p-process, or the origin of odd-Z elements in the most metal-poor stars. Canada has a long tradition of leadership in nuclear astrophysics, dating back to the work of Alastair Cameron in the 1950s. Recent faculty hires have further boosted activity in the field, including transient observation and theory, survey science on galactic nucleosynthesis, and nuclear experiments. This white paper contains a brief overview of recent activity in the community, highlighting strengths in each sub-field, and provides recommendations to improve interdisciplinary collaboration. Sustaining Canadian leadership in the next decade will require, on the observational side, access to transient and non-transient surveys like LSST, SKA, or MSE, support for target-of-opportunity observing in current and future Canadian telescopes, and participation in next-generation X-ray telescopes such as ATHENA. State-of-the-art theoretical predictions will require an ambitious succession plan for the Niagara supercomputer to support large parallel jobs. We propose a funding instrument for postdoctoral training that reflects the interdisciplinary nature of nuclear astrophysics research, and the creation of a national collaborative funding program that allows for joint projects and workshop organization.
△ Less
Submitted 21 October, 2019;
originally announced October 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Simulation of charge readout with segmented tiles in nEXO
Authors:
Z. Li,
W. R. Cen,
A. Robinson,
D. C. Moore,
L. J. Wen,
A. Odian,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland
, et al. (128 additional authors not shown)
Abstract:
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neu…
▽ More
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated $0νββ$ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the $0νββ$ signal from backgrounds. The estimated half-life sensitivity for $0νββ$ decay is improved by $\sim$20$~(32)\%$ with the multi-variate~(deep neural network) methods considered here, relative to the sensitivity estimated in the nEXO pre-conceptual design report.
△ Less
Submitted 11 October, 2019; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Search for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset
Authors:
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (77 additional authors not shown)
Abstract:
A search for neutrinoless double-beta decay ($0νββ$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0νββ$ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4$\pm$3.0% and the energy resolution of the detector at the Q-value of $^{136}$Xe $0νββ$ has been improved from…
▽ More
A search for neutrinoless double-beta decay ($0νββ$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0νββ$ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4$\pm$3.0% and the energy resolution of the detector at the Q-value of $^{136}$Xe $0νββ$ has been improved from $σ/E=1.23\%$ to $1.15\pm0.02\%$ with the upgraded detector. Accounting for the new data, the median 90% confidence level $0νββ$ half-life sensitivity for this analysis is $5.0 \cdot 10^{25}$ yr with a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $3.5\cdot10^{25}$ yr at the 90% confidence level.
△ Less
Submitted 18 October, 2019; v1 submitted 6 June, 2019;
originally announced June 2019.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Weakly Bound Neutron-Rich Nuclei and Cosmic Phenomena
Authors:
Ushasi Datta,
A. Rahaman,
S. Chakraborty,
B. K. Agrawal,
T. Aumann,
K. Boretzky,
C. Caesar,
H. Emling,
H. Geissel,
C. Langer,
T. Le Bleis,
Y. Leifels,
J. Marganiec,
G. Münzenberg,
C. Nociforo,
R. Plag,
R. Reinferth,
V. Ricciardi,
D. Rossi,
C. Scheidenberger,
H. Simon,
S. Typel,
V. Volkov,
F. Wamers,
J. S. Winfield
, et al. (16 additional authors not shown)
Abstract:
The single particle and bulk properties of the neutron-rich nuclei constrain fundamental issues in nuclear physics and nuclear astrophysics like the limits of existence of quantum many body systems (atomic nuclei), the equation of state of neutron-rich matter, neutron star, nucleosynthesis, evolution of stars, neutron star merging etc.. The state of the art of Coulomb breakup of the neutron-rich n…
▽ More
The single particle and bulk properties of the neutron-rich nuclei constrain fundamental issues in nuclear physics and nuclear astrophysics like the limits of existence of quantum many body systems (atomic nuclei), the equation of state of neutron-rich matter, neutron star, nucleosynthesis, evolution of stars, neutron star merging etc.. The state of the art of Coulomb breakup of the neutron-rich nuclei has been used to explore those properties. Unambiguous information on detailed components of the ground-state wave-function along with quantum numbers of the valence neutron of the nuclei have been obtained from the measurement of threshold strength along with the $γ$-rays spectra of the core following Coulomb breakup. The shape of this threshold strength is a finger-print of the quantum numbers of the nucleon. We investigated the ground-state properties of the neutron-rich Na, Mg, Al nuclei around N $\sim$ 20 using this method at GSI, Darmstadt. Very clear evidence has been observed for melting and merging of long cherished magic shell gaps at N = 20, 28. The evanescent neutron-rich nuclei imprint their existence in stellar explosive scenarios (r-process etc.). Coulomb dissociation (CD) is one of the important indirect measurements of the capture cross-section which may provide valuable input to the model for star evolution process, particularly the r-process.
Some valuable bulk properties of the neutron-rich nuclei like the density dependent symmetry energy,neutron skin etc. play a key role in understanding cosmic phenomena and these properties have been studied via electromagnetic excitation. Preliminary results of electromagnetic excitation of the neutron-rich nucleus, $^{32}$Mg are presented.
△ Less
Submitted 13 November, 2018; v1 submitted 21 October, 2018;
originally announced October 2018.
-
Half-Lives of Neutron Rich $^{130}$Cd and $^{131}$In
Authors:
R. Dunlop,
C. E. Svensson,
C. Andreoiu,
G. C. Ball,
N. Bernier,
V. Bildstein,
H. Bidaman,
P. Boubel,
C. Burbadge,
R. Caballero-Folch,
I. Dillmann,
M. R. Dunlop,
L. J. Evitts,
F. H. Garcia,
A. B. Garnsworthy,
P. E. Garrett,
G. Hackman,
S. Hallam,
J. Henderson,
S. Ilyushkin,
A. Jungclaus,
R. Krücken,
J. Lassen,
R. Li,
E. MacConnachie
, et al. (18 additional authors not shown)
Abstract:
The half-lives of isotopes around the $N=82$ shell closure are an important ingredient in astrophysical simulations and strongly influence the magnitude of the second $r$-process abundance peak in the $A\sim130$ region. The most neutron-rich $N=82$ nuclei are not accessible to the current generation of radioactive beam facilities and $r$-process simulations must therefore rely on calculations of t…
▽ More
The half-lives of isotopes around the $N=82$ shell closure are an important ingredient in astrophysical simulations and strongly influence the magnitude of the second $r$-process abundance peak in the $A\sim130$ region. The most neutron-rich $N=82$ nuclei are not accessible to the current generation of radioactive beam facilities and $r$-process simulations must therefore rely on calculations of the half-lives of the isotopes involved. Half-life measurements of the experimentally accessible nuclei in this region are important in order to benchmark these calculations. The half-life of $^{130}$Cd is particularly important as it is used to tune the Gamow-Teller quenching in shell-model calculations for the $β$ decay of other nuclei in this region. In this work, the GRIFFIN $γ$-ray spectrometer at the TRIUMF-ISAC facility was used to measure the half-life of $^{130}_{~48}$Cd$_{82}$ to be $T_{1/2}= 126(4)$ ms. In addition, the half-lives of the three $β$ decaying states of $^{131}_{~49}$In$_{82}$ were measured to be $T_{1/2}(1/2^-)=328(15)$ ms, $T_{1/2}(9/2^+)=265(8)$ ms, and $T_{1/2}(21/2^+)=323(50)$ ms, respectively, providing an important benchmark for half-life calculations in this region.
△ Less
Submitted 16 October, 2018;
originally announced October 2018.
-
High-resolution (p,t) reaction measurements as spectroscopic tests of {\it ab-initio} theory in the mid $pf$-shell
Authors:
K. G. Leach,
J. D. Holt,
P. E. Garrett,
S. R. Stroberg,
G. C. Ball,
P. C. Bender,
V. Bildstein,
A. Diaz Varela,
R. Dunlop,
T. Faestermann,
B. Hadinia,
R. Hertenberger,
D. S. Jamieson,
B. Jigmeddorj,
R. Krücken,
A. T. Laffoley,
A. J. Radich,
E. T. Rand,
C. E. Svensson,
S. Triambak,
H. -F. Wirth
Abstract:
Detailed spectroscopic measurements of excited states in $^{50}$Cr and $^{62}$Zn were performed using 24~MeV (p,t) transfer reactions on $^{52}$Cr and $^{64}$Zn, respectively. In total, forty-five states in $^{50}$Cr and sixty-seven states in $^{62}$Zn were observed up to excitation energies of 5.5~MeV, including several previously unobserved states. These experimental results are compared to {\it…
▽ More
Detailed spectroscopic measurements of excited states in $^{50}$Cr and $^{62}$Zn were performed using 24~MeV (p,t) transfer reactions on $^{52}$Cr and $^{64}$Zn, respectively. In total, forty-five states in $^{50}$Cr and sixty-seven states in $^{62}$Zn were observed up to excitation energies of 5.5~MeV, including several previously unobserved states. These experimental results are compared to {\it ab-initio} shell-model calculations using chiral effective field theory ($χ$-EFT) with the valence-space in-medium similarity renormalization group (VS-IMSRG) method. This comparison demonstrates good agreement in the level orderings with these new theoretical methods, albeit with a slight over binding in the calculations. This work is part of a continued push to benchmark {\it ab-initio} theoretical techniques to nuclear structure data in $0^+\rightarrow0^+$ superallowed Fermi $β$ decay systems.
△ Less
Submitted 28 September, 2018;
originally announced October 2018.
-
The GRIFFIN Facility for Decay-Spectroscopy Studies at TRIUMF-ISAC
Authors:
A. B. Garnsworthy,
C. E. Svensson,
M. Bowry,
R. Dunlop,
A. D. MacLean,
B. Olaizola,
J. K. Smith,
F. A. Ali,
C. Andreoiu,
J. E. Ash,
W. H. Ashfield,
G. C. Ball,
T. Ballast,
C. Bartlett,
Z. Beadle,
P. C. Bender,
N. Bernier,
S. S. Bhattacharjee,
H. Bidaman,
V. Bildstein,
D. Bishop,
P. Boubel,
R. Braid,
D. Brennan,
T. Bruhn
, et al. (79 additional authors not shown)
Abstract:
Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new high-efficiency $γ$-ray spectrometer designed for use in decay spectroscopy experiments with low-energy radioactive ion beams provided by TRIUMF's Isotope Separator and Accelerator (ISAC-I) facility. GRIFFIN is composed of sixteen Compton-suppressed large-volume clover-type high-purity germanium (HPGe) $γ$-ray det…
▽ More
Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new high-efficiency $γ$-ray spectrometer designed for use in decay spectroscopy experiments with low-energy radioactive ion beams provided by TRIUMF's Isotope Separator and Accelerator (ISAC-I) facility. GRIFFIN is composed of sixteen Compton-suppressed large-volume clover-type high-purity germanium (HPGe) $γ$-ray detectors combined with a suite of ancillary detection systems and coupled to a custom digital data acquisition system. The infrastructure and detectors of the spectrometer as well as the performance characteristics and the analysis techniques applied to the experimental data are described.
△ Less
Submitted 6 December, 2018; v1 submitted 17 September, 2018;
originally announced September 2018.
-
Shape Coexistence and Mixing of Low-Lying $0^+$ States in $^{96}$Sr
Authors:
S. Cruz,
P. C. Bender,
R. Krücken,
K. Wimmer,
F. Ames,
C. Andreoiu,
R. A. E. Austin,
C. S. Bancroft,
R. Braid,
T. Bruhn,
W. N. Catford,
A. Cheeseman,
A. Chester,
D. S. Cross,
C. Aa. Diget,
T. Drake,
A. B. Garnsworthy,
G. Hackman,
R. Kanungo,
A. Knapton,
W. Korten,
K. Kuhn,
J. Lassen,
R. Laxdal,
M. Marchetto
, et al. (10 additional authors not shown)
Abstract:
The low energy excited $0_{2,3}^+$ states in $^{96}$Sr are amongst the most prominent examples of shape coexistence across the nuclear landscape. In this work, the neutron $[2s_{1/2}]^2$ content of the $0_{1,2,3}^+$ states in $^{96}$Sr was determined by means of the d($^{95}$Sr,p) transfer reaction at the TRIUMF-ISAC2 facility using the SHARC and TIGRESS arrays. Spectroscopic factors of 0.19(3) an…
▽ More
The low energy excited $0_{2,3}^+$ states in $^{96}$Sr are amongst the most prominent examples of shape coexistence across the nuclear landscape. In this work, the neutron $[2s_{1/2}]^2$ content of the $0_{1,2,3}^+$ states in $^{96}$Sr was determined by means of the d($^{95}$Sr,p) transfer reaction at the TRIUMF-ISAC2 facility using the SHARC and TIGRESS arrays. Spectroscopic factors of 0.19(3) and 0.22(3) were extracted for the $^{96}$Sr ground and 1229~keV $0^+$ states, respectively, by fitting the experimental angular distributions to DWBA reaction model calculations. A detailed analysis of the $γ$-decay of the isomeric $0_3^+$ state was used to determine a spectroscopic factor of 0.33(13). The experimental results are compared to shell model calculations, which predict negligible spectroscopic strength for the excited $0^+$ states in $^{96}$Sr. The strengths of the excited $0_{2,3}^+$ states were also analyzed within a two-level mixing model and are consistent with a mixing strength of $a^2$=0.40(14) and a difference in intrinsic deformations of $|Δβ|=0.31(3)$. These results suggest coexistence of three different configurations in $^{96}$Sr and strong shape mixing of the two excited $0^+$ states.
△ Less
Submitted 16 September, 2018;
originally announced September 2018.
-
In-beam internal conversion electron spectroscopy with the SPICE detector
Authors:
M. Moukaddam,
J. Smallcombe,
L. J. Evitts,
A. B. Garnsworthy,
C. Andreoiu,
G. C. Ball,
J. Berean-Dutcher,
D. Bishop,
C. Bolton,
R. Caballero-Folch,
M. Constable,
D. S. Cross,
T. E. Drake,
R. Dunlop,
P. E. Garrett,
S. Georges,
G. Hackman,
S. Hallam,
J. Henderson,
R. Henderson,
R. Krücken,
L. Kurchaninov,
A. Kurkjian,
B. Olaizola,
E. O'Sullivan
, et al. (14 additional authors not shown)
Abstract:
The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $γ$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined wi…
▽ More
The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $γ$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined with TIGRESS, enables in-beam $γ$-ray and internal conversion electron spectroscopy to be performed with stable and radioactive ion beams. Technical aspects of the device, capabilities, and initial performance are presented.
△ Less
Submitted 8 August, 2018;
originally announced August 2018.
-
Study of Silicon Photomultiplier Performance in External Electric Fields
Authors:
X. L. Sun,
T. Tolba,
G. F. Cao,
P. Lv,
L. J. Wen,
A. Odian,
F. Vachon,
A. Alamre,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois
, et al. (127 additional authors not shown)
Abstract:
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estima…
▽ More
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before drop** abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
Authors:
A. Jamil,
T. Ziegler,
P. Hufschmidt,
G. Li,
L. Lupin-Jimenez,
T. Michel,
I. Ostrovskiy,
F. Retière,
J. Schneider,
M. Wagenpfeil,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers
, et al. (118 additional authors not shown)
Abstract:
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting t…
▽ More
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
△ Less
Submitted 13 March, 2019; v1 submitted 6 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
Authors:
S. Delaquis,
M. J. Jewell,
I. Ostrovskiy,
M. Weber,
T. Ziegler,
J. Dalmasson,
L. J. Kaufman,
T. Richards,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels
, et al. (69 additional authors not shown)
Abstract:
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what…
▽ More
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.
△ Less
Submitted 30 August, 2018; v1 submitted 25 April, 2018;
originally announced April 2018.
-
Search for nucleon decays with EXO-200
Authors:
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (70 additional authors not shown)
Abstract:
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
△ Less
Submitted 11 April, 2018; v1 submitted 20 October, 2017;
originally announced October 2017.
-
Characterization of an Ionization Readout Tile for nEXO
Authors:
nEXO Collaboration,
M. Jewell,
A. Schubert,
W. R. Cen,
J. Dalmasson,
R. DeVoe,
L. Fabris,
G. Gratta,
A. Jamil,
G. Li,
A. Odian,
M. Patel,
A. Pocar,
D. Qiu,
Q. Wang,
L. J. Wen,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky
, et al. (120 additional authors not shown)
Abstract:
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale n…
▽ More
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.
△ Less
Submitted 19 January, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
Authors:
nEXO Collaboration,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
M. Côté,
A. Craycraft,
W. Cree,
J. Dalmasson
, et al. (121 additional authors not shown)
Abstract:
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by…
▽ More
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.
△ Less
Submitted 19 October, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector
Authors:
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (68 additional authors not shown)
Abstract:
Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cry…
▽ More
Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between $0νββ$ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level $0νββ$ half-life sensitivity after combining with the full data set acquired before the upgrade has increased 2-fold to $3.7 \times 10^{25}$ yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $1.8\times10^{25}$ yr at the 90% confidence level.
△ Less
Submitted 26 February, 2018; v1 submitted 27 July, 2017;
originally announced July 2017.
-
The nuclear force imprints revealed on the elastic scattering of protons with $^{10}$C
Authors:
A. Kumar,
R. Kanungo,
A. Calci,
P. Navratil,
A. Sanetullaev,
M. Alcorta,
V. Bildstein,
G. Christian,
B. Davids,
J. Dohet-Eraly,
J. Fallis,
A. T. Gallant,
G. Hackman,
B. Hadinia,
G. Hupin,
S. Ishimoto,
R. Krücken,
A. T. Laffoley,
J. Lighthall,
D. Miller,
S. Quaglioni,
J. S. Randhawa,
E. T. Rand,
A. Rojas,
R. Roth
, et al. (4 additional authors not shown)
Abstract:
How does nature hold together protons and neutrons to form the wide variety of complex nuclei in the universe? Describing many-nucleon systems from the fundamental theory of quantum chromodynamics has been the greatest challenge in answering this question. The chiral effective field theory description of the nuclear force now makes this possible but requires certain parameters that are not uniquel…
▽ More
How does nature hold together protons and neutrons to form the wide variety of complex nuclei in the universe? Describing many-nucleon systems from the fundamental theory of quantum chromodynamics has been the greatest challenge in answering this question. The chiral effective field theory description of the nuclear force now makes this possible but requires certain parameters that are not uniquely determined. Defining the nuclear force needs identification of observables sensitive to the different parametrizations. From a measurement of proton elastic scattering on $^{10}$C at TRIUMF and ab initio nuclear reaction calculations we show that the shape and magnitude of the measured differential cross section is strongly sensitive to the nuclear force prescription.
△ Less
Submitted 15 May, 2017;
originally announced May 2017.
-
Critical assessment of nuclear sensitivity metrics for the r-process
Authors:
Zachary Shand,
Rachid Ouyed,
Nico Koning,
Iris Dillmann,
Reiner Krücken,
Prashanth Jaikumar
Abstract:
Any simulation of the r-process is affected by uncertainties in our present knowledge of nuclear physics quantities and astrophysical conditions. It is common to quantify the impact of these uncertainties through a global sensitivity metric, which is then used to identify specific nuclides that would be most worthwhile to measure experimentally. Using descriptive statistics, we assess a set of met…
▽ More
Any simulation of the r-process is affected by uncertainties in our present knowledge of nuclear physics quantities and astrophysical conditions. It is common to quantify the impact of these uncertainties through a global sensitivity metric, which is then used to identify specific nuclides that would be most worthwhile to measure experimentally. Using descriptive statistics, we assess a set of metrics used in previous sensitivity studies, as well as a new logarithmic measure. For certain neutron-rich nuclides lying near the r-process path for the typical hot-wind scenario, we find opposing conclusions on their relative sensitivity implied by different metrics, although they all generally agree which ones are the most sensitive nuclei. The underlying reason is that sensitivity metrics which simply sum over variations in the r-process distribution depend on the scaling used in the baseline, which often varies between simulations. We show that normalization of the abundances causes changes in the reported sensitivity factors and recommend reporting a minimized F statistic in addition to a scale estimation for rough calibration to be used when comparing tables of sensitivity factors from different studies.
△ Less
Submitted 28 April, 2017;
originally announced May 2017.
-
Searches for Double Beta Decay of $^{134}$Xe with EXO-200
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian
, et al. (69 additional authors not shown)
Abstract:
Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of $\text{T}_{1/2}^{2νβ\!β}>8.7\cdot10^{20}\text{ yr}$ and $\text{T}_{1/2}^{0νβ\!β}>1.1\cdot10^{23}\text{ yr}$ at 90% confidence level were derive…
▽ More
Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of $\text{T}_{1/2}^{2νβ\!β}>8.7\cdot10^{20}\text{ yr}$ and $\text{T}_{1/2}^{0νβ\!β}>1.1\cdot10^{23}\text{ yr}$ at 90% confidence level were derived, with corresponding half-life sensitivities of $1.2\cdot10^{21}\text{ yr}$ and $1.9\cdot10^{23}\text{ yr}$. These limits exceed those in the literature for $^{134}$Xe, improving by factors of nearly $10^{5}$ and 2 for the two antineutrino and neutrinoless modes, respectively.
△ Less
Submitted 6 November, 2017; v1 submitted 17 April, 2017;
originally announced April 2017.
-
Trace radioactive impurities in final construction materials for EXO-200
Authors:
D. S. Leonard,
D. Auty,
T. Didberidze,
R. Gornea,
P. Grinberg,
R. MacLellan,
B. Methven,
A. Piepke,
J. -L. Vuilleumier,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree
, et al. (76 additional authors not shown)
Abstract:
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of…
▽ More
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.
△ Less
Submitted 31 March, 2017;
originally announced March 2017.
-
Analysis of pion production data measured by HADES in proton-proton collisions at 1.25 GeV
Authors:
G. Agakishiev,
A. Balanda,
D. Belver,
A. Belyaev,
J. C. Berger-Chen,
A. Blanco,
M. Böhmer,
J. L. Boyard,
P. Cabanelas,
S. Chernenko,
A. Dybczak,
E. Epple,
L. Fabbietti,
O. Fateev,
P. Finocchiaro,
P. Fonte,
J. Friese,
I. Fröhlich,
T. Galatyuk,
J. A. Garzón,
R. Gernhäuser,
K. Göbel,
M. Golubeva,
D. González-Díaz,
F. Guber
, et al. (75 additional authors not shown)
Abstract:
Baryon resonance production in proton-proton collisions at a kinetic beam energy of 1.25 GeV is investigated. The multi-differential data were measured by the HADES collaboration. Exclusive channels with one pion in the final state ($npπ^{+}$ and $ppπ^{0}$) were put to extended studies based on various observables in the framework of a one-pion exchange model and with solutions obtained within the…
▽ More
Baryon resonance production in proton-proton collisions at a kinetic beam energy of 1.25 GeV is investigated. The multi-differential data were measured by the HADES collaboration. Exclusive channels with one pion in the final state ($npπ^{+}$ and $ppπ^{0}$) were put to extended studies based on various observables in the framework of a one-pion exchange model and with solutions obtained within the framework of a partial wave analysis (PWA) of the Bonn-Gatchina group. The results of the PWA confirm the dominant contribution of the $Δ$(1232), yet with a sizable impact of the $N$(1440) and non-resonant partial waves.
△ Less
Submitted 24 March, 2017;
originally announced March 2017.