A hybrid solution for simultaneous transfer of ultrastable optical frequency, RF frequency and UTC time-tags over optical fiber
Authors:
P. Krehlik,
H. Schnatz,
L. Sliwczynski
Abstract:
We describe a fiber-optic solution for simultaneous distribution of all signals generated at todays most advanced time and frequency laboratories, i.e. an ultrastable optical reference frequency derived from an optical atomic clock, a radio frequency precisely linked to a realization of the SI-Second, and a realization of an atomic timescale, being the local representation of the virtual, global U…
▽ More
We describe a fiber-optic solution for simultaneous distribution of all signals generated at todays most advanced time and frequency laboratories, i.e. an ultrastable optical reference frequency derived from an optical atomic clock, a radio frequency precisely linked to a realization of the SI-Second, and a realization of an atomic timescale, being the local representation of the virtual, global UTC timescale. In our solution both the phase of the optical carrier and the delay of electrical signals (10 MHz frequency reference and one pulse-per-second time tags) are stabilized against environmental perturbations influencing the fiber link instability and accuracy. We experimentally demonstrate optical transfer stabilities of 5e-18 and 2e-15 for 100 s averaging period, for optical carrier and 10 MHz signals, respectively.
△ Less
Submitted 6 June, 2017;
originally announced June 2017.
-
Fibre-optic delivery of time and frequency to VLBI station
Authors:
P. Krehlik,
Ł. Buczek,
J. Kołodziej,
M. Lipiński,
Ł. Śliwczyński,
J. Nawrocki,
P. Nogaś,
A. Marecki,
E. Pazderski,
P. Ablewski,
M. Bober,
R. Ciuryło,
A. Cygan,
D. Lisak,
P. Masłowski,
P. Morzyński,
M. Zawada,
R. M. Campbell,
J. Pieczerak,
A. Binczewski,
K. Turza
Abstract:
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabi…
▽ More
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabilized, long-distance fibre-optic link. The T&F reference signals, traceable to international atomic timescale (TAI), are delivered to the VLBI station from a dedicated timekee** laboratory. Moreover, we describe a proof-of-concept experiment where the VLBI station is synchronized to a remote strontium optical lattice clock during the observation.
△ Less
Submitted 7 July, 2017; v1 submitted 28 March, 2017;
originally announced March 2017.
-
Absolute measurement of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ clock transition in neutral ${}^{88}$Sr over the 330 km-long stabilized fibre optic link
Authors:
Piotr Morzynski,
Marcin Bober,
Dobroslawa Bartoszek-Bober,
Jerzy Nawrocki,
Przemyslaw Krehlik,
Lukasz Sliwczynski,
Marcin Lipinski,
Piotr Maslowski,
Agata Cygan,
Piotr Dunst,
Michal Garus,
Daniel Lisak,
Jerzy Zachorowski,
Wojciech Gawlik,
Czeslaw Radzewicz,
Roman Ciurylo,
Michal Zawada
Abstract:
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fi…
▽ More
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fibre optical link. The result was verified by series of measurements on two independent optical lattice clocks and agrees with recommendation of Bureau International des Poids et Mesures.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.