Large-scale detector testing for the GAPS Si(Li) Tracker
Authors:
Mengjiao Xiao,
Achim Stoessl,
Brandon Roach,
Cory Gerrity,
Ian Bouche,
Gabriel Bridges,
Philip von Doetinchem,
Charles J. Hailey,
Derik Kraych,
Anika Katt,
Michael Law,
Alexander Lowell,
Evan Martinez,
Kerstin Perez,
Maggie Reed,
Chelsea Rodriguez,
Nathan Saffold,
Ceaser Stringfield,
Hershel Weiner,
Kelsey Yee
Abstract:
Lithium-drifted silicon [Si(Li)] has been used for decades as an ionizing radiation detector in nuclear, particle, and astrophysical experiments, though such detectors have frequently been limited to small sizes (few cm$^2$) and cryogenic operating temperatures. The 10-cm-diameter Si(Li) detectors developed for the General Antiparticle Spectrometer (GAPS) balloon-borne dark matter experiment are n…
▽ More
Lithium-drifted silicon [Si(Li)] has been used for decades as an ionizing radiation detector in nuclear, particle, and astrophysical experiments, though such detectors have frequently been limited to small sizes (few cm$^2$) and cryogenic operating temperatures. The 10-cm-diameter Si(Li) detectors developed for the General Antiparticle Spectrometer (GAPS) balloon-borne dark matter experiment are novel particularly for their requirements of low cost, large sensitive area (~10 m$^2$ for the full 1440-detector array), high temperatures (near -40$\,^\circ$C), and energy resolution below 4 keV FWHM for 20--100-keV x-rays. Previous works have discussed the manufacturing, passivation, and small-scale testing of prototype GAPS Si(Li) detectors. Here we show for the first time the results from detailed characterization of over 1100 flight detectors, illustrating the consistent intrinsic low-noise performance of a large sample of GAPS detectors. This work demonstrates the feasibility of large-area and low-cost Si(Li) detector arrays for next-generation astrophysics and nuclear physics applications.
△ Less
Submitted 7 September, 2023; v1 submitted 29 April, 2023;
originally announced May 2023.
-
Statistical investigation of the large-area Si(Li) detectors mass-produced for the GAPS experiment
Authors:
M. Kozai,
K. Tokunaga,
H. Fuke,
M. Yamada,
C. J. Hailey,
C. Kato,
D. Kraych,
M. Law,
E. Martinez,
K. Munakata,
K. Perez,
F. Rogers,
N. Saffold,
Y. Shimizu,
K. Tokuda,
M. Xiao
Abstract:
The lithium-drifted silicon (Si(Li)) detector developed for the General Antiparticle Spectrometer (GAPS) experiment features a thick (~2.2 mm) sensitive layer, large (10 cm) diameter, and excellent energy resolution (~4 keV for 20-100 keV X-rays) at a relatively high operating temperature (approximately -40C). Mass production of GAPS Si(Li) detectors has been performed to construct a large-volume…
▽ More
The lithium-drifted silicon (Si(Li)) detector developed for the General Antiparticle Spectrometer (GAPS) experiment features a thick (~2.2 mm) sensitive layer, large (10 cm) diameter, and excellent energy resolution (~4 keV for 20-100 keV X-rays) at a relatively high operating temperature (approximately -40C). Mass production of GAPS Si(Li) detectors has been performed to construct a large-volume silicon tracker for GAPS. We achieved the first success of the mass production of large-area Si(Li) detectors with a high (~90%) yield rate. Valuable datasets related to detector fabrication, such as detector performance and manufacturing parameters, were recorded and collected during the mass production. This study analyzes the datasets using statistical methods with the aim of comprehensively examining the mass production and to gain valuable insight into the fabrication method. Sufficient uniformities of the performance parameters (leakage current and capacitance) between detectors and strips are found, demonstrating high-quality and stable mass production. We also search for correlations between detector performance and manufacturing parameters by using data-mining techniques. Conventional multivariate analysis (multiple regression analysis) and machine-learning techniques (regression tree analysis) are complementarily used, and it is found that the Li-drift process makes a significant contribution to the performance parameters of the finished detectors. Detailed investigation of the drift process is performed using environmental data, and physical interpretations are presented. Our results provide valuable insight into the fabrication methods for this kind of large-area Si(Li) detector, and encourages future projects that require large-volume silicon trackers.
△ Less
Submitted 1 May, 2022; v1 submitted 11 November, 2021;
originally announced November 2021.
-
Passivation of Si(Li) detectors operated above cryogenic temperatures for space-based applications
Authors:
Nathan Saffold,
Field Rogers,
Mengjiao Xiao,
Radhika Bhatt,
Tyler Erjavec,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Derik Kraych,
Evan Martinez,
Cianci Melo-Carrillo,
Kerstin Perez,
Chelsea Rodriguez,
Yuki Shimizu,
Brian Smallshaw
Abstract:
This work evaluates the viability of polyimide and parylene-C for passivation of lithium-drifted silicon (Si(Li)) detectors. The passivated Si(Li) detectors will form the particle tracker and X-ray detector of the General Antiparticle Spectrometer (GAPS) experiment, a balloon-borne experiment optimized to detect cosmic antideuterons produced in dark matter annihilations or decays. Successful passi…
▽ More
This work evaluates the viability of polyimide and parylene-C for passivation of lithium-drifted silicon (Si(Li)) detectors. The passivated Si(Li) detectors will form the particle tracker and X-ray detector of the General Antiparticle Spectrometer (GAPS) experiment, a balloon-borne experiment optimized to detect cosmic antideuterons produced in dark matter annihilations or decays. Successful passivation coatings were achieved by thermally curing polyimides, and the optimized coatings form an excellent barrier against humidity and organic contamination. The passivated Si(Li) detectors deliver $\lesssim\,4$ keV energy resolution (FWHM) for 20$-$100 keV X-rays while operating at temperatures of $-$35 to $-45\,^{\circ}$C. This is the first reported successful passivation of Si(Li)-based X-ray detectors operated above cryogenic temperatures.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.