-
Injection and capture of antiprotons in a Penning-Malmberg trap using a drift tube accelerator and degrader foil
Authors:
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
M. Hori,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Maeckel,
S. Migliorati,
D. J. Murtagh,
Y. Nagata
, et al. (11 additional authors not shown)
Abstract:
The Antiproton Decelerator (AD) at CERN provides antiproton bunches with a kinetic energy of 5.3 MeV. The Extra-Low ENergy Antiproton ring at CERN, commissioned at the AD in 2018, now supplies a bunch of electron-cooled antiprotons at a fixed energy of 100 keV. The MUSASHI antiproton trap was upgraded by replacing the radio-frequency quadrupole decelerator with a pulsed drift tube to re-accelerate…
▽ More
The Antiproton Decelerator (AD) at CERN provides antiproton bunches with a kinetic energy of 5.3 MeV. The Extra-Low ENergy Antiproton ring at CERN, commissioned at the AD in 2018, now supplies a bunch of electron-cooled antiprotons at a fixed energy of 100 keV. The MUSASHI antiproton trap was upgraded by replacing the radio-frequency quadrupole decelerator with a pulsed drift tube to re-accelerate antiprotons and optimize the injection energy into the degrader foils. By increasing the beam energy to 119 keV, a cooled antiproton accumulation efficiency of (26 +- 6)% was achieved.
△ Less
Submitted 11 June, 2024; v1 submitted 14 March, 2024;
originally announced March 2024.
-
Upgrade of the positron system of the ASACUSA-Cusp experiment
Authors:
A. Lanz,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
D. J. Murtagh,
A. Nanda,
L. Nowak
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator a…
▽ More
The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator and therefore decreasing the number of transfer cycles, the contamination of the vacuum has been reduced. Further to this, a new rare gas moderator and buffer gas trap, previously used at the Aarhus University, were installed. Measurements from Aarhus suggested that the number of positrons could be increased by a factor of four in comparison to the old system used at CERN. This would mean a reduction of the time needed for accumulating a sufficient number of positrons (of the order of a few million) for an antihydrogen production cycle. Initial tests have shown that the new system yields a comparable number of positrons to the old system.
△ Less
Submitted 14 July, 2023; v1 submitted 12 July, 2023;
originally announced July 2023.
-
Slow positron production and storage for the ASACUSA-Cusp experiment
Authors:
D. J. Murtagh,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Mal\-bru\-not,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
A. Nanda,
L. Nowak
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in po…
▽ More
The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in positron accumulation by a factor of ($52\pm3)$
△ Less
Submitted 22 June, 2023;
originally announced June 2023.
-
SDR, EVC, and SDREVC: Limitations and Extensions
Authors:
E. D. Hunter,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
D. J. Murtagh,
A. Nanda,
L. Nowak
, et al. (12 additional authors not shown)
Abstract:
Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrat…
▽ More
Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrate (2) an alternative to SDREVC, using e-kick instead of EVC and (3) an upper limit for how much plasma can be cooled to T < 20 K using EVC. This limit depends on the space charge, not on the number of particles or the plasma density.
△ Less
Submitted 3 June, 2023; v1 submitted 1 June, 2023;
originally announced June 2023.
-
Upgrade of ASACUSA's Antihydrogen Detector
Authors:
V. Kraxberger,
C. Amsler,
H. Breuker,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kletzl,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
S. Migliorati,
D. J. Murtagh,
Y. Nagata,
A. Nanda
, et al. (13 additional authors not shown)
Abstract:
The goal of the ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) CUSP experiment at CERN's Antiproton Decelerator is to measure the ground state hyperfine splitting of antihydrogen in order to test whether CPT invariance is broken.
The ASACUSA hodoscope is a detector consisting of two layers of 32 plastic scintillator bars individually read out by two serially connected silico…
▽ More
The goal of the ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) CUSP experiment at CERN's Antiproton Decelerator is to measure the ground state hyperfine splitting of antihydrogen in order to test whether CPT invariance is broken.
The ASACUSA hodoscope is a detector consisting of two layers of 32 plastic scintillator bars individually read out by two serially connected silicon photo multipliers (SiPMs) on each end. Two additional layers for position resolution along the beam axis were scintillator fibres, which will now be replaced by scintillating tiles placed onto the existing bars and also read out by SiPMs. If the antiproton of antihydrogen annihilates in the center of the hodoscope, particles (mostly pions) are produced and travel through the various layers of the detector and produce signals.
The hodoscope was successfully used during the last data taking period at CERN. The necessary time resolution to discriminate between particles travelling through the detector from outside and particles produced in the center of the detector was achieved by the use of waveform digitisers and software constant fraction discrimination. The disadvantage of this readout scheme was the slow readout speed, which was improved by two orders of magnitude. This was done by omitting the digitisers and replacing them with TDCs reading out the digital time-over-threshold (ToT) signal using leading edge discrimination.
△ Less
Submitted 24 October, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
Cyclotron cooling to cryogenic temperature in a Penning-Malmberg trap with a large solid angle acceptance
Authors:
C. Amsler,
H. Breuker,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kletzl,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
S. Migliorati,
D. J. Murtagh,
Y. Nagata,
A. Nanda
, et al. (13 additional authors not shown)
Abstract:
Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, res…
▽ More
Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
Minimizing plasma temperature for antimatter mixing experiments
Authors:
E. D. Hunter,
C. Amsler,
H. Breuker,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
Y. Kanai,
C. Killian,
V. Kletzl,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
S. Migliorati,
D. J. Murtagh,
Y. Nagata
, et al. (15 additional authors not shown)
Abstract:
The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental g…
▽ More
The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental groups observe that such plasmas reach equilibrium at a temperature well above the temperature of the surrounding electrodes. This problem is typically attributed to electronic noise and plasma expansion, which heat the plasma. The present work reports anomalous heating far beyond what can be attributed to those two sources. The heating seems to be a result of the axially open trap geometry, which couples the plasma to the external (300 K) environment via microwave radiation.
△ Less
Submitted 2 February, 2022; v1 submitted 4 January, 2022;
originally announced January 2022.