-
Optimized detection modality for double resonance alignment based optical magnetometer
Authors:
A. Akbar,
M. Kozbiál,
L. Elson,
A. Meraki,
J. Kolodyński,
K. Jensen
Abstract:
In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on multipole moments description. Experiments are carried out using a room-temperature paraffin-coated Caesiu…
▽ More
In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on multipole moments description. Experiments are carried out using a room-temperature paraffin-coated Caesium vapour cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization rotation detection mode yields larger signals and better sensitivity than absorption measurement of light.
△ Less
Submitted 8 March, 2024;
originally announced March 2024.
-
Spin noise spectroscopy of an alignment-based atomic magnetometer
Authors:
Marcin Kozbial,
Lucy Elson,
Lucas M. Rushton,
Ali Akbar,
Adil Meraki,
Kasper Jensen,
Jan Kolodynski
Abstract:
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pum** with circular or linear polarized light, r…
▽ More
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pum** with circular or linear polarized light, respectively. Characterisation of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pum**-probing beam. By varying the strength of the noise applied as well as the linear-polarisation angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding line-widths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks.
△ Less
Submitted 9 December, 2023;
originally announced December 2023.
-
Zero-field optical magnetometer based on spin-alignment
Authors:
Adil Meraki,
Lucy Elson,
Nok Ho,
Ali Akbar,
Marcin Koźbiał,
Jan Kołodyński,
Kasper Jensen
Abstract:
Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-al…
▽ More
Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero-field. A novel approach is introduced, which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.