-
Time Assignment System and Its Performance aboard the Hitomi Satellite
Authors:
Yukikatsu Terada,
Sunao Yamaguchi,
Shigenobu Sugimoto,
Taku Inoue,
Souhei Nakaya,
Maika Murakami,
Seiya Yabe,
Kenya Oshimizu,
Mina Ogawa,
Tadayasu Dotani,
Yoshitaka Ishisaki,
Kazuyo Mizushima,
Takashi Kominato,
Hiroaki Mine,
Hiroki Hihara,
Kaori Iwase,
Tomomi Kouzu,
Makoto S. Tashiro,
Chikara Natsukari,
Masanobu Ozaki,
Motohide Kokubun,
Tadayuki Takahashi,
Satoko Kawakami,
Masaru Kasahara,
Susumu Kumagai
, et al. (2 additional authors not shown)
Abstract:
Fast timing capability in X-ray observation of astrophysical objects is one of the key properties for the ASTRO-H (Hitomi) mission. Absolute timing accuracies of 350 micro second or 35 micro second are required to achieve nominal scientific goals or to study fast variabilities of specific sources. The satellite carries a GPS receiver to obtain accurate time information, which is distributed from t…
▽ More
Fast timing capability in X-ray observation of astrophysical objects is one of the key properties for the ASTRO-H (Hitomi) mission. Absolute timing accuracies of 350 micro second or 35 micro second are required to achieve nominal scientific goals or to study fast variabilities of specific sources. The satellite carries a GPS receiver to obtain accurate time information, which is distributed from the central onboard computer through the large and complex SpaceWire network. The details on the time system on the hardware and software design are described. In the distribution of the time information, the propagation delays and jitters affect the timing accuracy. Six other items identified within the timing system will also contribute to absolute time error. These error items have been measured and checked on ground to ensure the time error budgets meet the mission requirements. The overall timing performance in combination with hardware performance, software algorithm, and the orbital determination accuracies, etc, under nominal conditions satisfies the mission requirements of 35 micro second. This work demonstrates key points for space-use instruments in hardware and software designs and calibration measurements for fine timing accuracy on the order of microseconds for mid-sized satellites using the SpaceWire (IEEE1355) network.
△ Less
Submitted 14 December, 2017; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Sub-MeV Band Observation of a Hard Burst from AXP 1E 1547.0-5408 with the Suzaku Wide-band All-sky Monitor
Authors:
Tetsuya Yasuda,
Wataru B. Iwakiri,
Makoto S. Tashiro,
Yukikatsu Terada,
Tomomi Kouzu,
Teruaki Enoto,
Yu** E. Nakagawa,
Aya Bamba,
Yuji Urata,
Kazutaka Yamaoka,
Masanori Ohno,
Sinpei Shibata,
Kazuo Makishima,
The Suzaku-WAM team
Abstract:
The 2.1-s anomalous X-ray pulsar 1E 1547.0-5408 exhibited an X-ray outburst on 2009 January 22, emitting a large number of short bursts. The wide-band all- sky monitor (WAM) on-board Suzaku detected at least 254 bursts in the 160keV-6.2MeV band over the period of January 22 00:57-17:02 UT from the direction of 1E 1547.0-5408. One of these bursts, which occurred at 06:45:13, produced the brightest…
▽ More
The 2.1-s anomalous X-ray pulsar 1E 1547.0-5408 exhibited an X-ray outburst on 2009 January 22, emitting a large number of short bursts. The wide-band all- sky monitor (WAM) on-board Suzaku detected at least 254 bursts in the 160keV-6.2MeV band over the period of January 22 00:57-17:02 UT from the direction of 1E 1547.0-5408. One of these bursts, which occurred at 06:45:13, produced the brightest fluence in the 0.5-6.2MeV range, with an averaged 0.16-6.2MeV flux and extrapolated 25 keV-2 MeV fluence of about 3x10-6 erg cm-2 s-1 and about 3x10-4 erg cm-2, respectively. After pile-up corrections, the time-resolved WAM spectra of this burst were well-fitted in the 0.16-6.2MeV range by two-component models; specifically, a blackbody plus an optically thin thermal bremsstrahlung or a combination of a blackbody and a power-law component with an exponential cutoff. These results are compared with previous works reporting the persistent emission and weaker short bursts followed by the same outburst.
△ Less
Submitted 27 February, 2015; v1 submitted 17 February, 2015;
originally announced February 2015.
-
Spectral Variation of the Hard X-ray Emission from the Crab Nebula with the Suzaku Hard X-ray Detector
Authors:
Tomomi Kouzu,
Makoto S. Tashiro,
Yukikatsu Terada,
Shin'ya Yamada,
Aya Bamba,
Teruaki Enoto,
Koji Mori,
Yasushi Fukazawa,
Kazuo Makishima
Abstract:
The Crab Nebula is one of the brightest and most stable sources in the X-ray sky. Year-scale flux variation from the object was recently revealed in the hard X-ray band by four satellites. This marked the first detection of year-scale variability from pulsar wind nebulae in the hard X-ray band. The Crab Nebula has been observed at least once a year for calibration purposes with the Suzaku Hard X-r…
▽ More
The Crab Nebula is one of the brightest and most stable sources in the X-ray sky. Year-scale flux variation from the object was recently revealed in the hard X-ray band by four satellites. This marked the first detection of year-scale variability from pulsar wind nebulae in the hard X-ray band. The Crab Nebula has been observed at least once a year for calibration purposes with the Suzaku Hard X-ray Detector (HXD) since its launch in 2005. In order to investigate possible spectral changes as well as flux variation, the archival data of the HXD were analyzed. The flux variation reported by other instruments was confirmed in the 25 -- 100 keV band by the HXD in a few percent level, but flux above 100 keV did not follow the trend in variation below 100 keV. The hardness ratios produced utilizing the PIN and GSO sensors installed in the HXD exhibit significant scattering, thereby indicating spectral variations in the hard X-ray. The spectral changes are quantified by spectral fitting with a broken power-law model. The difference between the two photon indexes of the broken power-law model in harder and softer energy bands is in the range of < 2.54. Taking into account flux variation of 6.3% and spectral variation time-scale of a few days, multi components of the broken power-law-shaped synchrotron emission with different cooling times are suggested.
△ Less
Submitted 28 March, 2013;
originally announced March 2013.
-
Search for Diffuse X-rays from the Bow Shock Region of Runaway Star BD+43$^\circ$3654 with Suzaku
Authors:
Yukikatsu Terada,
Makoto S. Tashiro,
Aya Bamba,
Ryo Yamazaki,
Tomomi Kouzu,
Shu Koyama,
Hiromi Seta
Abstract:
The bow shocks of runaway stars with strong stellar winds of over 2000 km s$^{-1}$ can serve as particle acceleration sites. The conversion from stellar wind luminosity into particle acceleration power has an efficiency of the same order of magnitude as those in supernova remnants, based on the radio emission from the bow shock region of runaway star BD+43$^\circ$3654 \citep{Benaglia10}.If this ob…
▽ More
The bow shocks of runaway stars with strong stellar winds of over 2000 km s$^{-1}$ can serve as particle acceleration sites. The conversion from stellar wind luminosity into particle acceleration power has an efficiency of the same order of magnitude as those in supernova remnants, based on the radio emission from the bow shock region of runaway star BD+43$^\circ$3654 \citep{Benaglia10}.If this object exhibits typical characteristics, then runaway star systems can contribute a non-negligible fraction of Galactic cosmic-ray electrons. To constrain the maximum energy of accelerated particles from measurements of possible non-thermal emissions in the X-ray band, Suzaku observed BD+43$^\circ$3654 in April 2011 with an exposure of 99 ks. Because the onboard instruments have a stable and low background level, Suzaku detected a possible enhancement over the background of $7.6\pm 3.4$ cnt arcmin$^{-2}$ at the bow shock region, where the error represents the 3 sigma statistics only. However, the excess is not significant within the systematic errors of non-X-ray and cosmic-ray backgrounds of the X-ray Imaging Spectrometer, which are $\pm 6.0$ and $\pm 34$ cnt arcmin$^{-2}$, respectively, and the 3-sigma upper limit in the X-ray luminosity from the shock region, which is $1.1 \times 10^{32}$ erg s$^{-1}$ per 41.2 arcmin$^2$ in the 0.5 to 10 keV band. This result leads to three conclusions: (1) a shock-heating process is inefficient on this system; (2) the maximum energy of electrons does not exceed $\sim$ 10 TeV, corresponding to a Lorentz factor of less than $10^7$; and (3) the magnetic field in the shock acceleration site might not be as turbulent as those in pulsar wind nebulae and supernova remnants.
△ Less
Submitted 23 July, 2012;
originally announced July 2012.
-
Improvements in calibration of GSO scintillators in the Suzaku Hard X-ray Detector
Authors:
Shin'ya Yamada,
Kazuo Makishima,
Kazuhiro Nakazawa,
Motohide Kokubun,
Madoka Kawaharada,
Takao Kitaguchi,
Shin Watanabe,
Hiromitsu Takahashi,
Hirofumi Noda,
Hiroyuki Nishioka,
Kazuyoshi Hiragi,
Katsuhiro Hayashi,
Kenta Nakajima,
Makoto Tashiro,
Makoto Sasano,
Sho Nishino,
Shunsuke Torii,
Soki Sakurai,
Tadayuki Takahashi,
Tsunefumi Mizuno,
Teruaki Enoto,
Takayuki Yuasa,
Takaaki Tanaka,
Tomomi Kouzu,
Toshio Nakano
, et al. (5 additional authors not shown)
Abstract:
Improvements of in-orbit calibration of GSO scintillators in the Hard X-ray Detector on board Suzaku are reported. To resolve an apparent change of the energy scale of GSO which appeared across the launch for unknown reasons, consistent and thorough re-analyses of both pre-launch and in-orbit data have been performed. With laboratory experiments using spare hardware, the pulse height offset, corre…
▽ More
Improvements of in-orbit calibration of GSO scintillators in the Hard X-ray Detector on board Suzaku are reported. To resolve an apparent change of the energy scale of GSO which appeared across the launch for unknown reasons, consistent and thorough re-analyses of both pre-launch and in-orbit data have been performed. With laboratory experiments using spare hardware, the pulse height offset, corresponding to zero energy input, was found to change by ~0.5 of the full analog voltage scale, depending on the power supply. Furthermore, by carefully calculating all the light outputs of secondaries from activation lines used in the in-orbit gain determination, their energy deposits in GSO were found to be effectively lower, by several percent, than their nominal energies. Taking both these effects into account, the in-orbit data agrees with the on-ground measurements within ~5%, without employing the artificial correction introduced in the previous work (Kokubun et al. 2007). With this knowledge, we updated the data processing, the response, and the auxiliary files of GSO, and reproduced the HXD-PIN and HXD-GSO spectra of the Crab Nebula over 12-300 keV by a broken powerlaw with a break energy of ~110 keV.
△ Less
Submitted 25 July, 2011;
originally announced July 2011.
-
Suzaku X-Ray Imaging and Spectroscopy of Cassiopeia A
Authors:
Y. Maeda,
Y. Uchiyama,
A. Bamba,
H. Kosugi,
H. Tsunemi,
E. A. Helder,
J. Vink,
N. Kodaka,
Y. Terada,
Y. Fukazawa,
J. Hiraga,
J. P. Hughes,
M. Kokubun,
T. Kouzu,
H. Matsumoto,
E. Miyata,
R. Nakamura,
S. Okada,
K. Someya,
T. Tamagawa,
K. Tamura,
K. Totsuka,
Y. Tsuboi,
Y. Ezoe,
S. S. Holt
, et al. (4 additional authors not shown)
Abstract:
Suzaku X-ray observations of a young supernova remnant, Cassiopeia A, were carried out. K-shell transition lines from highly ionized ions of various elements were detected, including Chromium (Cr-Kalpha at 5.61 keV). The X-ray continuum spectra were modeled in the 3.4--40 keV band, summed over the entire remnant, and were fitted with a simplest combination of the thermal bremsstrahlung and the n…
▽ More
Suzaku X-ray observations of a young supernova remnant, Cassiopeia A, were carried out. K-shell transition lines from highly ionized ions of various elements were detected, including Chromium (Cr-Kalpha at 5.61 keV). The X-ray continuum spectra were modeled in the 3.4--40 keV band, summed over the entire remnant, and were fitted with a simplest combination of the thermal bremsstrahlung and the non-thermal cut-off power-law models. The spectral fits with this assumption indicate that the continuum emission is likely to be dominated by the non-thermal emission with a cut-off energy at > 1 keV. The thermal-to-nonthermal fraction of the continuum flux in the 4-10 keV band is best estimated as ~0.1. Non-thermal-dominated continuum images in the 4--14 keV band were made. The peak of the non-thermal X-rays appears at the western part. The peak position of the TeV gamma-rays measured with HEGRA and MAGIC is also shifted at the western part with the 1-sigma confidence. Since the location of the X-ray continuum emission was known to be presumably identified with the reverse shock region, the possible keV-TeV correlations give a hint that the accelerated multi-TeV hadrons in Cassiopeia A are dominated by heavy elements in the reverse shock region.
△ Less
Submitted 26 December, 2009;
originally announced December 2009.