Skip to main content

Showing 1–11 of 11 results for author: Koulouri, A

.
  1. arXiv:2106.03489  [pdf, other

    math.NA

    Conditionally Exponential Prior in Focal Near- and Far-Field EEG Source Localization via Randomized Multiresolution Scanning (RAMUS)

    Authors: Joonas Lahtinen, Alexandra Koulouri, Atena Rezaei, Sampsa Pursiainen

    Abstract: In this paper, we focus on the inverse problem of reconstructing distributional brain activity with cortical and weakly detectable deep components in non-invasive Electroencephalography. In particular, we aim to generalize the previously extensively used conditionally Gaussian prior (CGP) formalism to achieve distributional reconstructions with higher focality. For this purpose, we introduce as a… ▽ More

    Submitted 15 March, 2022; v1 submitted 7 June, 2021; originally announced June 2021.

    Comments: 23 pages, 16 figures, submitted to Journal of Mathematical Imaging and Vision

    MSC Class: 65M32 (Primary) 78A46; 35R30 (Secondary ACM Class: G.1.8

  2. arXiv:2105.05360  [pdf, other

    physics.ao-ph stat.ML

    Real-time Ionospheric Imaging of S4 Scintillation from Limited Data with Parallel Kalman Filters and Smoothness

    Authors: Alexandra Koulouri

    Abstract: In this paper, we propose a Bayesian framework to create two dimensional ionospheric images of high spatio-temporal resolution to monitor ionospheric irregularities as measured by the S4 index. Here, we recast the standard Bayesian recursive filtering for a linear Gaussian state-space model, also referred to as the Kalman filter, first by augmenting the (pierce point) observation model with connec… ▽ More

    Submitted 11 May, 2021; originally announced May 2021.

  3. arXiv:2007.05636  [pdf, ps, other

    math.OC eess.SP math.NA

    Adaptive Superresolution in Deconvolution of Sparse Peaks

    Authors: Alexandra Koulouri, Pia Heins, Martin Burger

    Abstract: The aim of this paper is to investigate superresolution in deconvolution driven by sparsity priors. The observed signal is a convolution of an original signal with a continuous kernel.With the prior knowledge that the original signal can be considered as a sparse combination of Dirac delta peaks, we seek to estimate the positions and amplitudes of these peaks by solving a finite dimensional convex… ▽ More

    Submitted 10 July, 2020; originally announced July 2020.

    Comments: It can help to improve super-resolution algorithms that use sparsity constraints

  4. Randomized Multiresolution Scanning in Focal and Fast E/MEG Sensing of Brain Activity with a Variable Depth

    Authors: Atena Rezaei, Alexandra Koulouri, Sampsa Pursiainen

    Abstract: We focus on electromagnetoencephalography imaging of the neural activity and, in particular, finding a robust estimate for the primary current distribution via the hierarchical Bayesian model (HBM). Our aim is to develop a reasonably fast maximum a posteriori (MAP) estimation technique which would be applicable for both superficial and deep areas without specific a priori knowledge of the number o… ▽ More

    Submitted 21 February, 2020; v1 submitted 11 February, 2020; originally announced February 2020.

    Comments: Brain Topogr (2020)

    MSC Class: 65Kxx; 92-04; 41-04 ACM Class: G.1.6; G.4; J.3; J.2; I.6.5

  5. arXiv:2002.00066  [pdf, other

    cs.LG eess.SP stat.AP stat.ML

    Simultaneous Skull Conductivity and Focal Source Imaging from EEG Recordings with the help of Bayesian Uncertainty Modelling

    Authors: Alexandra Koulouri, Ville Rimpilainen

    Abstract: The electroencephalography (EEG) source imaging problem is very sensitive to the electrical modelling of the skull of the patient under examination. Unfortunately, the currently available EEG devices and their embedded software do not take this into account; instead, it is common to use a literature-based skull conductivity parameter. In this paper, we propose a statistical method based on the Bay… ▽ More

    Submitted 31 January, 2020; originally announced February 2020.

  6. arXiv:2001.11830  [pdf, other

    physics.med-ph

    Electrical Impedance Tomography with Box Constraint for Skull Conductivity Estimation

    Authors: Ville Rimpilainen, Theodoros Samaras, Alexandra Koulouri

    Abstract: Unknown electric conductivities of human tissues is a common issue in medical engineering. Electrical impedance tomography (EIT) is an imaging modality that can be used to determine these conductivities in vivo from boundary measurements. In this paper, we demonstrate that local conductivity values of different skull segments can be solved from EIT measurements with the help of a box constraint. B… ▽ More

    Submitted 31 January, 2020; originally announced January 2020.

  7. arXiv:2001.02198  [pdf, ps, other

    stat.AP

    Position Dilution of Precision: a Bayesian point of view

    Authors: Alexandra Koulouri, Ville Rimpiläinen, Nathan D. Smith

    Abstract: The expected position error in many cases is far from feasible to be estimated experimentally using real satellite measurements which makes the model-based position dilution of precision (PDOP) crucial in positioning and navigation applications. In the following text we derive the relationship between PDOP and position error and we explain that this relationship holds as long as the model for the… ▽ More

    Submitted 28 January, 2020; v1 submitted 5 January, 2020; originally announced January 2020.

  8. Methodology to estimate ionospheric scintillation risk maps and their contribution to position dilution of precision on the ground

    Authors: Alexandra Koulouri, Nathan D. Smith, Bruno C. Vani, Ville Rimpilainen, Ivan Astin, Biagio Forte

    Abstract: Satellite-based communications, navigation systems and many scientific instruments rely on observations of trans-ionospheric signals. The quality of these signals can be deteriorated by ionospheric scintillation which can have detrimental effects on the mentioned applications. Therefore, monitoring of ionospheric scintillation and quantifying its effect on the ground are of significant interest. I… ▽ More

    Submitted 5 February, 2020; v1 submitted 19 November, 2019; originally announced November 2019.

    Comments: Keywords: Ionospheric scintillation risk, dilution of precision, statistics error covariances, weights, South America, S4 index, GNSS positioning uncertainty

  9. arXiv:1705.00708  [pdf, other

    q-bio.QM

    Overcoming the ill-posedness through discretization in vector tomography: Reconstruction of irrotational vector fields

    Authors: Alexandra Koulouri

    Abstract: Vector tomography methods intend to reconstruct and visualize vector fields in restricted domains by measuring line integrals of projections of these vector fields. Here, we deal with the reconstruction of irrotational vector functions from boundary measurements. As the majority of inverse problems, vector field recovery is an ill posed in the continuous domain and therefore further assumptions, m… ▽ More

    Submitted 27 April, 2017; originally announced May 2017.

    Comments: Technical report

  10. arXiv:1703.09044  [pdf, other

    physics.med-ph physics.comp-ph

    Prior Variances and Depth Un-Biased Estimators in EEG Focal Source Imaging

    Authors: Alexandra Koulouri, Ville Rimpiläinen, Mike Brookes, Jari P Kaipio

    Abstract: In electroencephalography (EEG) source imaging, the inverse source estimates are depth biased in such a way that their maxima are often close to the sensors. This depth bias can be quantified by inspecting the statistics (mean and co-variance) of these estimates. In this paper, we find weighting factors within a Bayesian framework for the used L1/L2 sparsity prior that the resulting maximum a post… ▽ More

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 4 pages, 3 figures, European Medical and Biological Engineering Conference

  11. arXiv:1703.09031  [pdf, other

    physics.med-ph physics.comp-ph

    Bayesian Modelling of Skull Conductivity Uncertainties in EEG Source Imaging

    Authors: Ville Rimpiläinen, Alexandra Koulouri, Felix Lucka, Jari P Kaipio, Carsten H Wolters

    Abstract: Knowing the correct skull conductivity is crucial for the accuracy of EEG source imaging, but unfortunately, its true value, which is inter- and intra-individually varying, is difficult to determine. In this paper, we propose a statistical method based on the Bayesian approximation error approach to compensate for source imaging errors related to erroneous skull conductivity. We demonstrate the po… ▽ More

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 4 pages, 2 figures, European Medical and Biological Engineering Conference