An optically pumped magnetic gradiometer for the detection of human biomagnetism
Authors:
Harry Cook,
Yulia Bezsudnova,
Lari M. Koponen,
Ole Jensen,
Giovanni Barontini,
Anna U. Kowalczyk
Abstract:
We realise an intrinsic optically pumped magnetic gradiometer based on non-linear magneto-optical rotation. We show that our sensor can reach a gradiometric sensitivity of 18 $\text{fT}/\text{cm}/\sqrt{\text{Hz}}$ and can reject common mode homogeneous magnetic field noise with up to 30 dB attenuation. We demonstrate that our magnetic field gradiometer is sufficiently sensitive and resilient to be…
▽ More
We realise an intrinsic optically pumped magnetic gradiometer based on non-linear magneto-optical rotation. We show that our sensor can reach a gradiometric sensitivity of 18 $\text{fT}/\text{cm}/\sqrt{\text{Hz}}$ and can reject common mode homogeneous magnetic field noise with up to 30 dB attenuation. We demonstrate that our magnetic field gradiometer is sufficiently sensitive and resilient to be employed in biomagnetic applications. In particular, we are able to record the auditory evoked response of the human brain, and to perform real-time magnetocardiography in the presence of external magnetic field disturbances. Our gradiometer provides complementary capabilities in human biomagnetic sensing to optically pumped magnetometers, and opens new avenues in the detection of human biomagnetism.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Double-containment coil with enhanced winding mounting for transcranial magnetic stimulation with reduced acoustic noise
Authors:
Lari M. Koponen,
Stefan M. Goetz,
Angel V. Peterchev
Abstract:
Objective: This work aims to reduce the acoustic noise level of transcranial magnetic stimulation (TMS) coils. TMS requires high currents (several thousand amperes) to be pulsed through the coil, which generates a loud acoustic impulse whose peak sound pressure level (SPL) can exceed 130 dB(Z). This sound poses a risk to hearing and elicits unwanted neural activation of auditory brain circuits. Me…
▽ More
Objective: This work aims to reduce the acoustic noise level of transcranial magnetic stimulation (TMS) coils. TMS requires high currents (several thousand amperes) to be pulsed through the coil, which generates a loud acoustic impulse whose peak sound pressure level (SPL) can exceed 130 dB(Z). This sound poses a risk to hearing and elicits unwanted neural activation of auditory brain circuits. Methods: We propose a new double-containment coil with enhanced winding mounting (DCC), which utilizes acoustic impedance mismatch to contain and dissipate the impulsive sound within an air-tight outer casing. The coil winding is potted in a rigid block, which is mounted to the outer casing by its acoustic nodes that are subject to minimum vibration during the pulse. The rest of the winding block is isolated from the casing by an air gap, and sound is absorbed by foam within the casing. The casing thickness under the winding center is minimized to maximize the coil electric field output. Results: Compared to commercial figure-of-eight TMS coils, the DCC prototype has 10-33 dB(Z) lower SPL at matched stimulation strength, whilst providing 22% higher maximum stimulation strength than equally focal commercial coils. Conclusion: The DCC design greatly reduces the acoustic noise of TMS while increasing the achievable stimulation strength. Significance: The acoustic noise reduction from our coil design is comparable to that provided by typical hearing protection devices. This coil design approach can enhance hearing safety and reduce auditory co-activations in the brain and other detrimental effects of TMS sound.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.