Development of crystal optics for Multi-Projection X-ray Imaging for synchrotron and XFEL sources
Authors:
Valerio Bellucci,
Sarlota Birnsteinova,
Tokushi Sato,
Romain Letrun,
Jayanath C. P. Koliyadu,
Chan Kim,
Gabriele Giovanetti,
Carsten Deiter,
Liubov Samoylova,
Ilia Petrov,
Luis Lopez Morillo,
Rita Graceffa,
Luigi Adriano,
Helge Huelsen,
Heiko Kollmann,
Thu Nhi Tran Calliste,
Dusan Korytar,
Zdenko Zaprazny,
Andrea Mazzolari,
Marco Romagnoni,
Eleni Myrto Asimakopoulou,
Zisheng Yao,
Yuhe Zhang,
Jozef Ulicny,
Alke Meents
, et al. (5 additional authors not shown)
Abstract:
X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of indust…
▽ More
X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. Indeed, the speed of traditional tomography is limited by the shear forces caused by rotation, to a maximum of 1000 Hz in state-of-the-art tomography. Moreover, the shear forces can disturb the phenomena in observation, in particular with soft samples or sensitive phenomena such as fluid dynamics. XMPI is based on splitting an X-ray beam to generate multiple simultaneous views of the sample, therefore eliminating the need for rotation. The achievable performances depend on the characteristics of the X-ray source, the detection system, and the X-ray optics used to generate the multiple views. The increase in power density of the X-ray sources around the world now enables 3D imaging with sampling speeds in the kilohertz range at synchrotrons and megahertz range at X-ray Free-Electron Lasers (XFELs). Fast detection systems are already available, and 2D MHz imaging was already demonstrated at synchrotron and XFEL. In this work, we explore the properties of X-ray splitter optics and XMPI schemes that are compatible with synchrotron insertion devices and XFEL X-ray beams. We describe two possible schemes designed to permit large samples and complex sample environments. Then, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
-
3D-Printed Sheet Jet for Stable Megahertz Liquid Sample Delivery at X-ray Free Electron Lasers
Authors:
Patrick E. Konold,
Tong You,
Johan Bielecki,
Joana Valerio,
Marco Kloos,
Daniel Westphal,
Alfredo Bellisario,
Tej Varma,
August Wolter,
Jayanath C. P. Koliyadu,
Faisal H. M. Koua,
Romain Letrun,
Adam Round,
Tokushi Sato,
Petra Mésźaros,
Leonardo Monrroy,
Jennifer Mutisya,
Szabolcs Bódizs,
Taru Larkiala,
Amke Nimmrich,
Roberto Alvarez,
Richard Bean,
Tomas Ekeberg,
Richard A. Kirian,
Sebastian Westenhoff
, et al. (1 additional authors not shown)
Abstract:
X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a b…
▽ More
X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves a high-speed liquid jet, capable of kee** up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the X-ray pointing related problems. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. They are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although they have seen increasing use for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, we demonstrate liquid sheet jet sample injection at the European XFEL. We evaluate several aspects of its performance relative to a conventional liquid jet including thickness profile, stability, and radiation-induced explosion dynamics at high repetition rates. The sheet jet exhibits superior performance across these critical experimental parameters. Its minute thickness also suggests ultrafast single-particle solution scattering is a possibility.
△ Less
Submitted 13 June, 2023;
originally announced June 2023.
-
Megahertz X-ray Multi-projection imaging
Authors:
Pablo Villanueva-Perez,
Valerio Bellucci,
Yuhe Zhang,
Sarlota Birnsteinova,
Rita Graceffa,
Luigi Adriano,
Eleni Myrto Asimakopoulou,
Ilia Petrov,
Zisheng Yao,
Marco Romagnoni,
Andrea Mazzolari,
Romain Letrun,
Chan Kim,
Jayanath C. P. Koliyadu,
Carsten Deiter,
Richard Bean,
Gabriele Giovanetti,
Luca Gelisio,
Tobias Ritschel,
Adrian Mancuso,
Henry N. Chapman,
Alke Meents,
Tokushi Sato,
Patrik Vagovic
Abstract:
X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz…
▽ More
X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz (MHz) X-ray multi-projection imaging (MHz-XMPI), a technique capable of recording volumetric information at MHz rates and micrometer resolution without scanning the sample. We achieved this by harnessing the unique megahertz pulse structure and intensity of the European X-ray Free-electron Laser with a combination of novel detection and reconstruction approaches that do not require sample rotations. Our approach enables generating multiple X-ray probes that simultaneously record several angular projections for each pulse in the megahertz pulse burst. We provide a proof-of-concept demonstration of the MHz-XMPI technique's capability to probe 4D (3D+time) information on stochastic phenomena and non-reproducible processes three orders of magnitude faster than state-of-the-art time-resolved X-ray tomography, by generating 3D movies of binary droplet collisions. We anticipate that MHz-XMPI will enable in-situ and operando studies that were impossible before, either due to the lack of temporal resolution or because the systems were opaque (such as for MHz imaging based on optical microscopy).
△ Less
Submitted 19 May, 2023;
originally announced May 2023.
-
Ultrasound cavitation and exfoliation dynamics of 2D materials re-vealed in operando by X-ray free electron laser megahertz imaging
Authors:
Kang Xiang,
Shi Huang,
Hongyuan Song,
Vasilii Bazhenov,
Valerio Bellucci,
Sarlota Birnsteinova,
Raphael de Wijn,
Jayanath C. P. Koliyadu,
Faisal H. M. Koua,
Adam Round,
Ekaterina Round,
Abhisakh Sarma,
Tokushi Sato,
Marcin Sikorski,
Yuhe Zhang,
Eleni Myrto Asimakopoulou,
Pablo Villanueva-Perez,
Kyriakos Porfyrakis,
Iakovos Tzanakis,
Dmitry G. Eskin,
Nicole Grobert,
Adrian Mancuso,
Richard Bean,
Patrik Vagovic,
Jiawei Mi
Abstract:
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simul…
▽ More
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simultaneously, most theories reported to date still remain elusive. Here, using the ultra-short X-ray Free Electron Laser pulses (~25ps) with a unique pulse train structure, we applied MHz X-ray Microscopy and machine-learning technique to reveal unambiguously the full cycles of the ultrasound cavitation and graphite layer exfoliation dynamics with sub-microsecond and micrometer resolution. Cyclic fatigue shock wave impacts produced by ultrasound cloud implosion were identified as the dominant mechanism to deflect and exfoliate graphite layers mechanically. For the graphite flakes, exfoliation rate as high as ~5 angstroms per shock wave impact was observed. For the HOPG graphite, the highest exfoliation rate was ~0.15 angstroms per impact. These new findings are scientifically and technologically important for develo** industrial upscaling strategies for ultrasonic exfoliation of 2D materials.
△ Less
Submitted 23 June, 2023; v1 submitted 15 May, 2023;
originally announced May 2023.
-
Online dynamic flat-field correction for MHz Microscopy data at European XFEL
Authors:
Sarlota Birnsteinova,
Danilo E. Ferreira de Lima,
Egor Sobolev,
Henry J. Kirkwood,
Valerio Bellucci,
Richard J. Bean,
Chan Kim,
Jayanath C. P. Koliyadu,
Tokushi Sato,
Fabio Dall'Antonia,
Eleni Myrto Asimakopoulou,
Zisheng Yao,
Khachiwan Buakor,
Yuhe Zhang,
Alke Meents,
Henry N. Chapman,
Adrian P. Mancuso,
Pablo Villanueva-Perez,
Patrik Vagovic
Abstract:
The X-ray microscopy technique at the European X-ray free-electron laser (EuXFEL), operating at a MHz repetition rate, provides superior contrast and spatial-temporal resolution compared to typical microscopy techniques at other X-ray sources. In both online visualization and offline data analysis for microscopy experiments, baseline normalization is essential for further processing steps such as…
▽ More
The X-ray microscopy technique at the European X-ray free-electron laser (EuXFEL), operating at a MHz repetition rate, provides superior contrast and spatial-temporal resolution compared to typical microscopy techniques at other X-ray sources. In both online visualization and offline data analysis for microscopy experiments, baseline normalization is essential for further processing steps such as phase retrieval and modal decomposition. In addition, access to normalized projections during data acquisition can play an important role in decision-making and improve the quality of the data. However, the stochastic nature of XFEL sources hinders the use of existing flat-flied normalization methods during MHz X-ray microscopy experiments. Here, we present an online dynamic flat-field correction method based on principal component analysis of dynamically evolving flat-field images. The method is used for the normalization of individual X-ray projections and has been implemented as an online analysis tool at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument of EuXFEL.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.