-
Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer
Authors:
David J. Mercer,
Ryan Winkler,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Krystal I. de Castro,
Eric A. Feissle,
Joseph W. Fowler,
Johnathon D. Gard,
John A. B. Mates,
Daniel G. McNeel,
Nathan J. Ortiz,
Daniel Schmidt,
Katherine A. Schreiber,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Sophie L. Weidenbenner,
Abigail L. Wessels
Abstract:
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter…
▽ More
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.
△ Less
Submitted 8 July, 2022; v1 submitted 6 February, 2022;
originally announced February 2022.
-
Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers
Authors:
Mark Croce,
Daniel Becker,
Katrina E. Koehler,
Joel Ullom
Abstract:
Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma…
▽ More
Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and HPGe data, allowing direct comparison. We present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
New Experimentally Observable Gamma-ray Emissions from 241Am Nuclear Decay
Authors:
Katrina E. Koehler,
Michael D. Yoho,
Matthew H. Carpenter,
Mark P. Croce,
David J. Mercer,
Chandler M. Smith,
Aidan D. Tollefson,
Duc T. Vo,
Michael A. Famiano,
Daniel T. Becker,
Johnathon D. Gard,
J. A. B. Mates,
Nathan J. Ortiz,
Joel N. Ullom,
Abigail L. Wessels,
Douglas A. Bennett,
Daniel R. Schmidt,
Daniel S. Swetz,
Leila R. Vale
Abstract:
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis al…
▽ More
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis algorithms for microcalorimeters.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
First Measurements of Nuclear Detonation Debris with Decay Energy Spectroscopy
Authors:
Mark P. Croce,
Katrina E. Koehler,
Veronika Mocko,
Andrew S. Hoover,
Stosh A. Kozimor,
Daniel R. Schmidt,
Joel N. Ullom
Abstract:
We report the first isotopic composition measurements of trinitite, nuclear detonation debris from the Trinity test, using the novel forensics technique of decay energy spectroscopy (DES). DES measures the unique total decay energy (Q value) of each alpha-decaying isotope in a small radioactive sample embedded in a microcalorimeter detector. We find that DES can measure the major alpha-decaying is…
▽ More
We report the first isotopic composition measurements of trinitite, nuclear detonation debris from the Trinity test, using the novel forensics technique of decay energy spectroscopy (DES). DES measures the unique total decay energy (Q value) of each alpha-decaying isotope in a small radioactive sample embedded in a microcalorimeter detector. We find that DES can measure the major alpha-decaying isotopes in small particles of trinitite with no dissolution or chemical processing. These first measurements demonstrate the potential of DES to provide a radiometric isotopic characterization method with sensitivity and precision to complement traditional forensics techniques.
△ Less
Submitted 22 March, 2021;
originally announced March 2021.
-
Gamma and Decay Energy Spectroscopy Measurements of Trinitite
Authors:
D. J. Mercer,
K. E. Koehler,
M. P. Croce,
A. S. Hoover,
P. A. Hypes,
S. A. Kozimor,
V. Mocko,
P. R. J. Saey
Abstract:
We report gamma ray spectroscopy measurements of trinitite samples and analogous samples obtained from detonation sites in Nevada and Semipalatinsk, as well as in situ measurements of topsoil at the Trinity site. We also report the first isotopic composition measurements of trinitite using the novel forensics technique of decay energy spectroscopy (DES) as a complement to traditional forensics tec…
▽ More
We report gamma ray spectroscopy measurements of trinitite samples and analogous samples obtained from detonation sites in Nevada and Semipalatinsk, as well as in situ measurements of topsoil at the Trinity site. We also report the first isotopic composition measurements of trinitite using the novel forensics technique of decay energy spectroscopy (DES) as a complement to traditional forensics techniques. Our measurements are compared to other published results.
△ Less
Submitted 22 April, 2021; v1 submitted 10 March, 2021;
originally announced March 2021.
-
Measurement of Ac227 Impurity in Ac225 using Decay Energy Spectroscopy
Authors:
Aidan D. Tollefson,
Chandler M. Smith,
Matthew H. Carpenter,
Mark P. Croce,
Michael E. Fassbender,
Katrina E. Koehler,
Laura M. Lilley,
Ellen M. O'Brien,
Daniel R. Schmidt,
Benjamin W. Stein,
Joel N. Ullom,
Michael D. Yoho,
David J. Mercer
Abstract:
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (T…
▽ More
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small change in temperature. By embedding 225Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from alpha decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss herein. Using this technique we measured the EOB 227Ac impurity to be (0.142 +/- 0.005)% for a single production sample. This demonstration has shown that DES can distinguish closely related isotopic features and is a useful tool for quantitative measures.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.
-
Improved Plutonium and Americium Photon Branching Ratios from Microcalorimeter Gamma Spectroscopy
Authors:
Michael D. Yoho,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Johnathon D. Gard,
J. A. Ben Mates,
David J. Mercer,
Nathan J. Ortiz,
Daniel R. Schmidt,
Chandler M. Smith,
Daniel S. Swetz,
Aidan D. Tollefson,
Joel N. Ullom,
Leila R. Vale,
Abigail L. Wessels,
Duc T. Vo
Abstract:
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-h…
▽ More
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium (238Pu,239Pu,241Pu) and 241Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. We show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2{3 for four branching ratios.
△ Less
Submitted 22 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
First Calorimetric Measurement of Electron Capture in ${}^{193}$Pt with a Transition Edge Sensor
Authors:
Katrina E. Koehler,
Michael A. Famiano,
Chris J. Fontes,
Thomas W. Gorczyca,
Michael W. Rabin,
Dan R. Schmidt,
Joel N. Ullom,
Mark P. Croce
Abstract:
The neutrino mass can be extracted from a high statistics, high resolution calorimetric spectrum of electron capture in ${}^{163}$Ho. In order to better understand the shape of the calorimetric electron capture spectrum, a second isotope was measured with a close to ideal absorber-source configuration. ${}^{193}$Pt was created by irradiating a ${}^{192}$Pt-enriched platinum foil in a nuclear react…
▽ More
The neutrino mass can be extracted from a high statistics, high resolution calorimetric spectrum of electron capture in ${}^{163}$Ho. In order to better understand the shape of the calorimetric electron capture spectrum, a second isotope was measured with a close to ideal absorber-source configuration. ${}^{193}$Pt was created by irradiating a ${}^{192}$Pt-enriched platinum foil in a nuclear reactor. This Pt-in-Pt absorber was designed to have a nearly ideal absorber-source configuration. The measured ${}^{193}$Pt calorimetric electron-capture spectrum provides an independent check on the corresponding theoretical calculations, which have thus far been compared only for ${}^{163}$Ho. The first experimental and theoretically-calculated spectra from this ${}^{193}$Pt-in-Pt absorber are presented and overlaid for preliminary comparison of theory with experiment.
△ Less
Submitted 16 March, 2018;
originally announced March 2018.