-
Study of polysterene based scintillator ageing in the DANSS experiment
Authors:
DANSS Collaboration,
I. Alekseev,
V. Belov,
A. Bystryakov,
M. Danilov,
D. Filosofov,
M. Fomina,
P. Gorovtsov,
Ye. Iusko,
S. Kazartsev,
A. Kobyakin,
A. Krapiva,
A. Kuznetsov,
N. Mashin,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko
, et al. (8 additional authors not shown)
Abstract:
DANSS is a spectrometer of reactor antineutrino based on plastic scintillator. The sensitive volume of the detector is made of 2500 polystyrene based scintillator plates with wavelength shifting (WLS) fiber readout (strips). We present a study of the strips light yield during 6.5 years of DANSS continuous running. Overall ageing at the rate $0.55 \pm 0.05(syst.)$ % per year is observed that is con…
▽ More
DANSS is a spectrometer of reactor antineutrino based on plastic scintillator. The sensitive volume of the detector is made of 2500 polystyrene based scintillator plates with wavelength shifting (WLS) fiber readout (strips). We present a study of the strips light yield during 6.5 years of DANSS continuous running. Overall ageing at the rate $0.55 \pm 0.05(syst.)$ % per year is observed that is considerably smaller than in other similar experiments. We also observe the WLS fiber attenuation length shortening at the rate $0.26 \pm 0.04(stat.)$ % per year.
△ Less
Submitted 23 November, 2023;
originally announced November 2023.
-
Application of the Duperier method to the analysis of the cosmic muon flux dependence on the meteorological parameters, based on the DANSS detector data
Authors:
I. Alekseev,
V. Belov,
M. Danilov,
D. Filosofov,
M. Fomina,
S. Kazartsev,
A. Kobyakin,
A. Kuznetsov,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
N. Skrobova,
D. Svirida,
E. Tarkovsky,
A. Yakovleva,
E. Yakushev,
I. Zhitnikov
, et al. (1 additional authors not shown)
Abstract:
The detector DANSS is located under n industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~ 50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector DANSS is located under an industrial nuclear r…
▽ More
The detector DANSS is located under n industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~ 50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector DANSS is located under an industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector's sensitive area consists of 2500 plastic scintillator counters, each 100x4x1 cm$^3$ in size, making in total a 1 m$^3$ volume, which is surrounded by a muon veto system and multiple layers of passive shielding. The main goal of the DANSS experiment is to study the antineutrino spectra at different distances from the source. For this purpose the detector is placed on a lifting platform, and the data is collected at three positions: 10.9 m, 11.9 m and 12.9 m from the center of the reactor core. The detector is capable of reconstructing muon tracks passing though the sensitive volume. In this work the barometric, height and temperature correlation coefficients are calculated in three areas of the zenith angle $θ$ using the Duperier approach. These results are based on the muon data collected during four years.
△ Less
Submitted 10 July, 2023;
originally announced July 2023.
-
Optimized scintillation strip design for the DANSS upgrade
Authors:
DANSS Collaboration,
I. Alekseev,
V. Belov,
A. Bystryakov,
M. Danilov,
A. Ershova,
D. Filosofov,
M. Fomina,
S. Kazartsev,
A. Kobyakin,
N. Kozlenko,
A. Kuznetsov,
I. Machikhiliyan,
F. Mamedov,
D. Medvedev,
V. Nesterov,
D. Novinsky,
K. Perminov,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko
, et al. (10 additional authors not shown)
Abstract:
DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile…
▽ More
DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile neutrino exclusion regions. Yet a moderate energy resolution of the detector prevents the further progress in the physics program. The main challenge of the planned upgrade is to achieve the energy resolution of 12% at 1 MeV. The new design of the main sensitive element - the plastic scintillation strip - is the most important step forward. The strip prototypes were manufactured and tested at the pion beam of the PNPI synchrocyclotron. More than twice higher light output together with fairly flat detector response uniformity, longitudinal timing information and other optimizations will surely help to reach the upgrade goal. The paper discusses the drawbacks of the current strip version, outlines the new features of the proposed upgrade, describes the beam test procedure and presents the test results reflecting the advantages of the new strip design in comparison with the currently used version.
△ Less
Submitted 13 April, 2022; v1 submitted 9 December, 2021;
originally announced December 2021.
-
Observation of the temperature and barometric effects on the cosmic muon flux by the DANSS detector
Authors:
DANSS Collaboration,
I. Alekseev,
V. Belov,
V. Brudanin,
A. Bystryakov,
M. Danilov,
V. Egorov,
D. Filosofov,
M. Fomina,
S. Kazartsev,
A. Kobyakin,
A. Kuznetsov,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
N. Skrobova,
A. Starostin,
D. Svirida
, et al. (4 additional authors not shown)
Abstract:
The DANSS detector is located directly below a commercial reactor core at the Kalinin Nuclear Power Plant. Such a position provides an overburden about 50 m.w.e. in vertical direction. In terms of the cosmic rays it occupies an intermediate position between surface and underground detectors. The sensitive volume of the detector is a cubic meter of plastic scintillator with fine segmentation and co…
▽ More
The DANSS detector is located directly below a commercial reactor core at the Kalinin Nuclear Power Plant. Such a position provides an overburden about 50 m.w.e. in vertical direction. In terms of the cosmic rays it occupies an intermediate position between surface and underground detectors. The sensitive volume of the detector is a cubic meter of plastic scintillator with fine segmentation and combined PMT and SiPM readout, surrounded by multilayer passive and active shielding. The detector can reconstruct muon tracks passing through its sensitive volume. The main physics goal of the DANSS experiment implies the antineutrino spectra measurements at various distances from the source. This is achieved by means of a lifting platform so that the data is taken in three positions - 10.9, 11.9 and 12.9 meters from the reactor core. The muon data were collected for nearly four calendar years. The overburden parameters $\langle E_{thr}\cosθ\rangle$ and $\langle E_{thr} \rangle$, as well as the temperature and barometric correlation coefficients are evaluated separately for the three detector positions and, in each position, in three ranges of the zenith angle - for nearly vertical muons with $\cosθ>0.9$, for nearly horizontal muons with $\cosθ<0.36$, and for the whole upper hemisphere.
△ Less
Submitted 30 May, 2022; v1 submitted 7 December, 2021;
originally announced December 2021.
-
Search for sterile neutrinos at the DANSS experiment
Authors:
I. Alekseev,
V. Belov,
V. Brudanin,
M. Danilov,
V. Egorov,
D. Filosofov,
M. Fomina,
Z. Hons,
S. Kazartsev,
A. Kobyakin,
A. Kuznetsov,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
A. Olshevsky,
N. Pogorelov,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
N. Skrobova
, et al. (6 additional authors not shown)
Abstract:
DANSS is a highly segmented 1~m${}^3$ plastic scintillator detector. Its 2500 one meter long scintillator strips have a Gd-loaded reflective cover. The DANSS detector is placed under an industrial 3.1~$\mathrm{GW_{th}}$ reactor of the Kalinin Nuclear Power Plant 350~km NW from Moscow. The distance to the core is varied on-line from 10.7~m to 12.7~m. The reactor building provides about 50~m water-e…
▽ More
DANSS is a highly segmented 1~m${}^3$ plastic scintillator detector. Its 2500 one meter long scintillator strips have a Gd-loaded reflective cover. The DANSS detector is placed under an industrial 3.1~$\mathrm{GW_{th}}$ reactor of the Kalinin Nuclear Power Plant 350~km NW from Moscow. The distance to the core is varied on-line from 10.7~m to 12.7~m. The reactor building provides about 50~m water-equivalent shielding against the cosmic background. DANSS detects almost 5000 $\widetildeν_e$ per day at the closest position with the cosmic background less than 3$\%$. The inverse beta decay process is used to detect $\widetildeν_e$. Sterile neutrinos are searched for assuming the $4ν$ model (3 active and 1 sterile $ν$). The exclusion area in the $Δm_{14}^2,\sin^22θ_{14}$ plane is obtained using a ratio of positron energy spectra collected at different distances. Therefore results do not depend on the shape and normalization of the reactor $\widetildeν_e$ spectrum, as well as on the detector efficiency. Results are based on 966 thousand antineutrino events collected at 3 distances from the reactor core. The excluded area covers a wide range of the sterile neutrino parameters up to $\sin^22θ_{14}<0.01$ in the most sensitive region.
△ Less
Submitted 14 November, 2018; v1 submitted 11 April, 2018;
originally announced April 2018.
-
DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator
Authors:
I. Alekseev,
V. Belov,
V. Brudanin,
M. Danilov,
V. Egorov,
D. Filosofov,
M. Fomina,
Z. Hons,
S. Kazartsev,
A. Kobyakin,
A. Kuznetsov,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
A. Olshevsky,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
N. Skrobova,
A. Starostin
, et al. (6 additional authors not shown)
Abstract:
The DANSS project is aimed at creating a relatively compact neutrino spectrometer which does not contain any flammable or other dangerous liquids and may therefore be located very close to the core of an industrial power reactor. As a result, it is expected that high neutrino flux would provide about 15,000 IBD interactions per day in the detector with a sensitive volume of 1 m$^3$. High segmentat…
▽ More
The DANSS project is aimed at creating a relatively compact neutrino spectrometer which does not contain any flammable or other dangerous liquids and may therefore be located very close to the core of an industrial power reactor. As a result, it is expected that high neutrino flux would provide about 15,000 IBD interactions per day in the detector with a sensitive volume of 1 m$^3$. High segmentation of the plastic scintillator will allow to suppress a background down to a 1% level. Numerous tests performed with a simplified pilot prototype DANSSino under a 3 GW$_{th}$ reactor of the Kalinin NPP have demonstrated operability of the chosen design. The DANSS detector surrounded with a composite shield is movable by means of a special lifting gear, varying the distance to the reactor core in a range from 10 m to 12 m. Due to this feature, it could be used not only for the reactor monitoring, but also for fundamental research including short-range neutrino oscillations to the sterile state. Supposing one-year measurement, the sensitivity to the oscillation parameters is expected to reach a level of $sin^2(2θ)$ ~ 0.005 with $Δm^2 \subset (0.02-5.0)$ eV$^2$.
△ Less
Submitted 11 October, 2016; v1 submitted 9 June, 2016;
originally announced June 2016.
-
Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
Authors:
D. Yu. Akimov,
V. V. Afanasyev,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
Yu. V. Efremenko,
D. A. Egorov,
A. V. Etenko,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin,
A. M. Konovalov,
A. G. Kovalenko,
A. V. Kuchenkov,
A. V. Kumpan,
Yu. A. Melikyan,
R. I. Nikolaev,
D. G. Rudik,
V. V. Sosnovtsev
, et al. (1 additional authors not shown)
Abstract:
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predicti…
▽ More
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predictions. Decay time of scintillation at 2.82 keV is measured to be 25 +/- 3 ns at the electric field of 3.75 kV/cm.
△ Less
Submitted 8 August, 2014;
originally announced August 2014.
-
DANSSino: a pilot version of the DANSS neutrino detector
Authors:
I. Alekseev,
V. Belov,
V. Brudanin,
M. Danilov,
V. Egorov,
D. Filosofov,
M. Fomina,
Z. Hons,
A. Kobyakin,
D. Medvedev,
R. Mizuk,
E. Novikov,
A. Olshevsky,
S. Rozov,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
A. Starostin,
D. Svirida,
E. Tarkovsky,
I. Tikhomirov,
E. Yakushev
, et al. (2 additional authors not shown)
Abstract:
DANSSino is a reduced pilot version of a solid-state detector of reactor antineutrinos (to be created within the DANSS project and installed under the industrial 3 GW(th) reactor of the Kalinin Nuclear Power Plant -- KNPP). Numerous tests performed at a distance of 11 m from the reactor core demonstrate operability of the chosen design and reveal the main sources of the background. In spite of its…
▽ More
DANSSino is a reduced pilot version of a solid-state detector of reactor antineutrinos (to be created within the DANSS project and installed under the industrial 3 GW(th) reactor of the Kalinin Nuclear Power Plant -- KNPP). Numerous tests performed at a distance of 11 m from the reactor core demonstrate operability of the chosen design and reveal the main sources of the background. In spite of its small size (20x20x100 ccm), the pilot detector turned out to be quite sensitive to reactor antineutrinos, detecting about 70 IBD events per day with the signal-to-background ratio about unity.
△ Less
Submitted 28 November, 2013; v1 submitted 14 May, 2013;
originally announced May 2013.
-
Registration of reactor neutrinos with the highly segmented plastic scintillator detector DANSSino
Authors:
V. Belov,
V. Brudanin,
M. Danilov,
V. Egorov,
M. Fomina,
A. Kobyakin,
V. Rusinov,
M. Shirchenko,
Yu. Shitov,
A. Starostin,
I. Zhitnikov
Abstract:
DANSSino is a simplified pilot version of a solid-state detector of reactor antineutrino (it is being created within the DANSS project and will be installed close to an industrial nuclear power reactor). Numerous tests performed under a 3 GW(th) reactor of the Kalinin NPP at a distance of 11 m from the core demonstrate operability of the chosen design and reveal the main sources of the background.…
▽ More
DANSSino is a simplified pilot version of a solid-state detector of reactor antineutrino (it is being created within the DANSS project and will be installed close to an industrial nuclear power reactor). Numerous tests performed under a 3 GW(th) reactor of the Kalinin NPP at a distance of 11 m from the core demonstrate operability of the chosen design and reveal the main sources of the background. In spite of its small size (20x20x100 ccm), the pilot detector turned out to be quite sensitive to reactor neutrinos, detecting about 70 IBD events per day with the signal-to-background ratio about unity.
△ Less
Submitted 16 May, 2013; v1 submitted 12 April, 2013;
originally announced April 2013.
-
Measurement and simulation of the muon-induced neutron yield in lead
Authors:
L. Reichhart,
A. Lindote,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy
, et al. (14 additional authors not shown)
Abstract:
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well…
▽ More
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well the measured capture times and multiplicities and, within the dynamic range of the instrumentation, the spectrum of energy deposits. By comparing measurements with simulations of neutron capture rates a neutron yield in lead of (5.78^{+0.21}_{-0.28}) x 10^{-3} neutrons/muon/(g/cm^{2}) has been obtained. Absolute agreement between simulation and data is of order 25%. Consequences for deep underground rare event searches are discussed.
△ Less
Submitted 4 November, 2013; v1 submitted 18 February, 2013;
originally announced February 2013.
-
Perspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector
Authors:
RED Collaboration,
D. Yu. Akimov,
I. S. Alexandrov,
V. I. Aleshin,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
A. S. Chepurnov,
M. V. Danilov,
A. V. Derbin,
V. V. Dmitrenko,
A. G. Dolgolenko,
D. A. Egorov,
Yu. V. Efremenko,
A. V. Etenko,
M. B. Gromov,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kantserov,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin
, et al. (21 additional authors not shown)
Abstract:
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites…
▽ More
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites have advantages as well as limitations. However the experiment looks feasible at either location. Preliminary design of the detector and supporting R&D program are discussed.
△ Less
Submitted 9 December, 2012;
originally announced December 2012.
-
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Authors:
V. N. Solovov,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (11 additional authors not shown)
Abstract:
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the…
▽ More
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
△ Less
Submitted 26 September, 2012; v1 submitted 7 December, 2011;
originally announced December 2011.
-
Performance data from the ZEPLIN-III second science run
Authors:
P. Majewski,
V. N. Solovov,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (10 additional authors not shown)
Abstract:
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the…
▽ More
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the instrument performance with emphasis on the position and energy reconstruction algorithm and summarise the final science results.
△ Less
Submitted 30 November, 2011;
originally announced December 2011.
-
Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator
Authors:
L. Reichhart,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling
, et al. (12 additional authors not shown)
Abstract:
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (…
▽ More
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (UPS-923A) is presented, exploring recoil energies between 125 keV and 850 keV. Monte Carlo simulations, incorporating light collection efficiency and energy resolution effects, are used to generate neutron scattering spectra which are matched to observed distributions of scintillation signals to parameterise the energy-dependent quenching factor. At energies above 300 keV the dependence is reasonably described using the semi-empirical formulation of Birks and a kB factor of (0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured quenching factor falls more steeply than predicted by the Birks formalism.
△ Less
Submitted 9 November, 2011;
originally announced November 2011.
-
WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling
, et al. (12 additional authors not shown)
Abstract:
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 ke…
▽ More
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 keV, which is compatible with background expectations. This allows the exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass with 90% confidence. Combined with data from the first run, this result improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its conclusion at Boulby, having deployed and exploited successfully three liquid xenon experiments of increasing reach.
△ Less
Submitted 16 December, 2011; v1 submitted 21 October, 2011;
originally announced October 2011.
-
Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
Authors:
E. Santos,
B. Edwards,
V. Chepel,
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
L. DeViveiros,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these…
▽ More
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of $\sim$3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Authors:
F. Neves,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. Preece
, et al. (12 additional authors not shown)
Abstract:
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d…
▽ More
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.
△ Less
Submitted 4 June, 2011;
originally announced June 2011.
-
Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
Authors:
M. Horn,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
C. Ghag,
A. Hollingsworth,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (11 additional authors not shown)
Abstract:
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r…
▽ More
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is found, together with a rising ionisation yield; both are in good agreement with the latest independent measurements. The analysis method is applied to both the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
△ Less
Submitted 17 October, 2011; v1 submitted 3 June, 2011;
originally announced June 2011.
-
Radioactivity Backgrounds in ZEPLIN-III
Authors:
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel. A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy. F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (10 additional authors not shown)
Abstract:
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level…
▽ More
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05$\pm$0.5 nuclear recoils with energy 5-50 keV per year, which translates to an expectation of 0.4 events in a 1-year dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from $β$ activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter $γ$-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of $\sim 1 \times 10^{-8}$ pb$\cdot$year to the scalar WIMP-nucleon elastic cross-section, as originally conceived.
△ Less
Submitted 12 August, 2011; v1 submitted 18 April, 2011;
originally announced April 2011.
-
Performance of the veto detector incorporated into the ZEPLIN-III experiment
Authors:
C. Ghag,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
K. Lyons,
P. Majewski,
A. St,
J. Murphy,
F. Neves
, et al. (14 additional authors not shown)
Abstract:
The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of…
▽ More
The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of operation in coincidence with ZEPLIN-III are presented. With fully automated operation and calibration, the veto system has maintained high stability and achieves near unity live time relative to ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60% of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be misidentified as WIMPs. This tagging efficiency reduces the expected untagged nuclear recoil background from neutrons during science data taking to a very low rate of ~0.2 events per year in the WIMP acceptance region. Additionally, the veto detector provides rejection of 28% of gamma-ray induced background events, allowing the sampling of the dominant source of background in ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will not be tagged by the veto detector, and tags due to gamma-rays and neutrons are separable, this population of multiple scatter events may be characterised without biasing the analysis of candidate WIMP signals in the data.
△ Less
Submitted 1 May, 2011; v1 submitted 2 March, 2011;
originally announced March 2011.
-
The ZEPLIN-III Anti-Coincidence Veto Detector
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim…
▽ More
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim has been to achieve a veto detector of low threshold and high efficiency without the creation of additional background in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of the components have been made, including radioactivity levels and performance characteristics. These have been used to inform a complete end-to-end Monte Carlo simulation that has then been used to calculate the expected performance of the new instrument, both operating alone and as an anti-coincidence detector for ZEPLIN-III. The veto device will be capable of rejecting over 65% of coincident nuclear recoil events from neutron background in the energy range of interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4 to ~0.14 events per year in the WIMP acceptance region, a significant factor in the event of a non-zero observation. Furthermore, in addition to providing valuable diagnostic capabilities, the veto is capable of tagging over 15% for gamma-ray rejection, all whilst contributing no significant additional background. In conjunction with the replacement of the internal ZEPLIN-III photomultiplier array, the new veto is expected to improve significantly the sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
△ Less
Submitted 27 April, 2010; v1 submitted 23 April, 2010;
originally announced April 2010.
-
Limits on inelastic dark matter from ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
R. Cashmore,
V. Chepel,
A. Currie,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
I. Liubarsky
, et al. (21 additional authors not shown)
Abstract:
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under…
▽ More
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under standard halo assumptions a small region of parameter space consistent, at 99% CL, with causing the 1.17 ton.year DAMA modulation signal is allowed at 90% CL: it is in the mass range 45-60 GeV with a minimum CL of 88%, again derived from the maximum patch. This is the tightest constraint on that explanation of the DAMA result yet presented using a xenon target.
△ Less
Submitted 1 April, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
Calibration of Photomultiplier Arrays
Authors:
F. Neves,
V. Chepel,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
B. Edwards,
C. Ghag,
M. Horn,
A. J. Hughes,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (9 additional authors not shown)
Abstract:
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields,…
▽ More
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields, etc) are exactly matched between calibration and science acquisitions. This is of particular importance in low background experiments such as ZEPLIN-III, where methods involving the use of external light sources for calibration are severely constrained.
△ Less
Submitted 15 May, 2009;
originally announced May 2009.