-
Anatomically informed Bayesian spatial priors for fMRI analysis
Authors:
David Abramian,
Per Sidén,
Hans Knutsson,
Mattias Villani,
Anders Eklund
Abstract:
Existing Bayesian spatial priors for functional magnetic resonance imaging (fMRI) data correspond to stationary isotropic smoothing filters that may oversmooth at anatomical boundaries. We propose two anatomically informed Bayesian spatial models for fMRI data with local smoothing in each voxel based on a tensor field estimated from a T1-weighted anatomical image. We show that our anatomically inf…
▽ More
Existing Bayesian spatial priors for functional magnetic resonance imaging (fMRI) data correspond to stationary isotropic smoothing filters that may oversmooth at anatomical boundaries. We propose two anatomically informed Bayesian spatial models for fMRI data with local smoothing in each voxel based on a tensor field estimated from a T1-weighted anatomical image. We show that our anatomically informed Bayesian spatial models results in posterior probability maps that follow the anatomical structure.
△ Less
Submitted 18 October, 2019;
originally announced October 2019.
-
Orientationally-averaged diffusion-attenuated magnetic resonance signal for locally-anisotropic diffusion
Authors:
Magnus Herberthson,
Cem Yolcu,
Hans Knutsson,
Carl-Fredrik Westin,
Evren Özarslan
Abstract:
Diffusion-attenuated MR signal for heterogeneous media has been represented as a sum of signals from anisotropic Gaussian sub-domains. Any effect of macroscopic (global or ensemble) anisotropy in the signal can be removed by averaging the signal values obtained by differently oriented experimental schemes. The resulting average signal is identical to what one would get if the micro-domains are iso…
▽ More
Diffusion-attenuated MR signal for heterogeneous media has been represented as a sum of signals from anisotropic Gaussian sub-domains. Any effect of macroscopic (global or ensemble) anisotropy in the signal can be removed by averaging the signal values obtained by differently oriented experimental schemes. The resulting average signal is identical to what one would get if the micro-domains are isotropically (e.g., randomly) distributed, which is the case for "powdered" specimens. We provide exact expressions for the orientationally-averaged signal obtained via general gradient waveforms when the microdomains are characterized by a general diffusion tensor possibly featuring three distinct eigenvalues. Our results are expected to be useful in not only multidimensional diffusion MR but also solid-state NMR spectroscopy due to the mathematical similarities in the two fields.
△ Less
Submitted 27 December, 2018;
originally announced December 2018.
-
Generating Diffusion MRI scalar maps from T1 weighted images using generative adversarial networks
Authors:
Xuan Gu,
Hans Knutsson,
Markus Nilsson,
Anders Eklund
Abstract:
Diffusion magnetic resonance imaging (diffusion MRI) is a non-invasive microstructure assessment technique. Scalar measures, such as FA (fractional anisotropy) and MD (mean diffusivity), quantifying micro-structural tissue properties can be obtained using diffusion models and data processing pipelines. However, it is costly and time consuming to collect high quality diffusion data. Here, we theref…
▽ More
Diffusion magnetic resonance imaging (diffusion MRI) is a non-invasive microstructure assessment technique. Scalar measures, such as FA (fractional anisotropy) and MD (mean diffusivity), quantifying micro-structural tissue properties can be obtained using diffusion models and data processing pipelines. However, it is costly and time consuming to collect high quality diffusion data. Here, we therefore demonstrate how Generative Adversarial Networks (GANs) can be used to generate synthetic diffusion scalar measures from structural T1-weighted images in a single optimized step. Specifically, we train the popular CycleGAN model to learn to map a T1 image to FA or MD, and vice versa. As an application, we show that synthetic FA images can be used as a target for non-linear registration, to correct for geometric distortions common in diffusion MRI.
△ Less
Submitted 9 April, 2019; v1 submitted 5 October, 2018;
originally announced October 2018.
-
Reply to Chen et al.: Parametric methods for cluster inference perform worse for two-sided t-tests
Authors:
Anders Eklund,
Hans Knutsson,
Thomas E. Nichols
Abstract:
One-sided t-tests are commonly used in the neuroimaging field, but two-sided tests should be the default unless a researcher has a strong reason for using a one-sided test. Here we extend our previous work on cluster false positive rates, which used one-sided tests, to two-sided tests. Briefly, we found that parametric methods perform worse for two-sided t-tests, and that non-parametric methods pe…
▽ More
One-sided t-tests are commonly used in the neuroimaging field, but two-sided tests should be the default unless a researcher has a strong reason for using a one-sided test. Here we extend our previous work on cluster false positive rates, which used one-sided tests, to two-sided tests. Briefly, we found that parametric methods perform worse for two-sided t-tests, and that non-parametric methods perform equally well for one-sided and two-sided tests.
△ Less
Submitted 5 October, 2018;
originally announced October 2018.
-
Cluster Failure Revisited: Impact of First Level Design and Data Quality on Cluster False Positive Rates
Authors:
Anders Eklund,
Hans Knutsson,
Thomas E Nichols
Abstract:
Methodological research rarely generates a broad interest, yet our work on the validity of cluster inference methods for functional magnetic resonance imaging (fMRI) created intense discussion on both the minutia of our approach and its implications for the discipline. In the present work, we take on various critiques of our work and further explore the limitations of our original work. We address…
▽ More
Methodological research rarely generates a broad interest, yet our work on the validity of cluster inference methods for functional magnetic resonance imaging (fMRI) created intense discussion on both the minutia of our approach and its implications for the discipline. In the present work, we take on various critiques of our work and further explore the limitations of our original work. We address issues about the particular event-related designs we used, considering multiple event types and randomisation of events between subjects. We consider the lack of validity found with one-sample permutation (sign flip**) tests, investigating a number of approaches to improve the false positive control of this widely used procedure. We found that the combination of a two-sided test and cleaning the data using ICA FIX resulted in nominal false positive rates for all datasets, meaning that data cleaning is not only important for resting state fMRI, but also for task fMRI. Finally, we discuss the implications of our work on the fMRI literature as a whole, estimating that at least 10% of the fMRI studies have used the most problematic cluster inference method (P = 0.01 cluster defining threshold), and how individual studies can be interpreted in light of our findings. These additional results underscore our original conclusions, on the importance of data sharing and thorough evaluation of statistical methods on realistic null data.
△ Less
Submitted 15 June, 2018; v1 submitted 9 April, 2018;
originally announced April 2018.
-
Bayesian uncertainty quantification in linear models for diffusion MRI
Authors:
Jens Sjölund,
Anders Eklund,
Evren Özarslan,
Magnus Herberthson,
Maria Bånkestad,
Hans Knutsson
Abstract:
Diffusion MRI (dMRI) is a valuable tool in the assessment of tissue microstructure. By fitting a model to the dMRI signal it is possible to derive various quantitative features. Several of the most popular dMRI signal models are expansions in an appropriately chosen basis, where the coefficients are determined using some variation of least-squares. However, such approaches lack any notion of uncer…
▽ More
Diffusion MRI (dMRI) is a valuable tool in the assessment of tissue microstructure. By fitting a model to the dMRI signal it is possible to derive various quantitative features. Several of the most popular dMRI signal models are expansions in an appropriately chosen basis, where the coefficients are determined using some variation of least-squares. However, such approaches lack any notion of uncertainty, which could be valuable in e.g. group analyses. In this work, we use a probabilistic interpretation of linear least-squares methods to recast popular dMRI models as Bayesian ones. This makes it possible to quantify the uncertainty of any derived quantity. In particular, for quantities that are affine functions of the coefficients, the posterior distribution can be expressed in closed-form. We simulated measurements from single- and double-tensor models where the correct values of several quantities are known, to validate that the theoretically derived quantiles agree with those observed empirically. We included results from residual bootstrap for comparison and found good agreement. The validation employed several different models: Diffusion Tensor Imaging (DTI), Mean Apparent Propagator MRI (MAP-MRI) and Constrained Spherical Deconvolution (CSD). We also used in vivo data to visualize maps of quantitative features and corresponding uncertainties, and to show how our approach can be used in a group analysis to downweight subjects with high uncertainty. In summary, we convert successful linear models for dMRI signal estimation to probabilistic models, capable of accurate uncertainty quantification.
△ Less
Submitted 19 February, 2018; v1 submitted 16 November, 2017;
originally announced November 2017.
-
Reply to Cox et al. and Kessler et al.: Data and code sharing is the way forward for fMRI
Authors:
Anders Eklund,
Thomas Nichols,
Hans Knutsson
Abstract:
We are glad that our paper has generated intense discussions in the fMRI field, on how to analyze fMRI data and how to correct for multiple comparisons. The goal of the paper was not to disparage any specific fMRI software, but to point out that parametric statistical methods are based on a number of assumptions that are not always valid for fMRI data, and that non-parametric statistical methods a…
▽ More
We are glad that our paper has generated intense discussions in the fMRI field, on how to analyze fMRI data and how to correct for multiple comparisons. The goal of the paper was not to disparage any specific fMRI software, but to point out that parametric statistical methods are based on a number of assumptions that are not always valid for fMRI data, and that non-parametric statistical methods are a good alternative. Through AFNIs introduction of non-parametric statistics in the function 3dttest++, the three most common fMRI softwares now all support non-parametric group inference (SPM through the toolbox SnPM, and FSL through the function randomise).
△ Less
Submitted 28 March, 2017;
originally announced March 2017.
-
A defense of using resting state fMRI as null data for estimating false positive rates
Authors:
Thomas E. Nichols,
Anders Eklund,
Hans Knutsson
Abstract:
A recent Editorial by Slotnick (2017) reconsiders the findings of our paper on the accuracy of false positive rate control with cluster inference in fMRI (Eklund et al, 2016), in particular criticising our use of resting state fMRI data as a source for null data in the evaluation of task fMRI methods. We defend this use of resting fMRI data, as while there is much structure in this data, we argue…
▽ More
A recent Editorial by Slotnick (2017) reconsiders the findings of our paper on the accuracy of false positive rate control with cluster inference in fMRI (Eklund et al, 2016), in particular criticising our use of resting state fMRI data as a source for null data in the evaluation of task fMRI methods. We defend this use of resting fMRI data, as while there is much structure in this data, we argue it is representative of task data noise and as such analysis software should be able to accommodate this noise. We also discuss a potential problem with Slotnick's own method.
△ Less
Submitted 18 January, 2017; v1 submitted 11 January, 2017;
originally announced January 2017.
-
Gaussian process regression can turn non-uniform and undersampled diffusion MRI data into diffusion spectrum imaging
Authors:
Jens Sjölund,
Anders Eklund,
Evren Özarslan,
Hans Knutsson
Abstract:
We propose to use Gaussian process regression to accurately estimate the diffusion MRI signal at arbitrary locations in q-space. By estimating the signal on a grid, we can do synthetic diffusion spectrum imaging: reconstructing the ensemble averaged propagator (EAP) by an inverse Fourier transform. We also propose an alternative reconstruction method guaranteeing a nonnegative EAP that integrates…
▽ More
We propose to use Gaussian process regression to accurately estimate the diffusion MRI signal at arbitrary locations in q-space. By estimating the signal on a grid, we can do synthetic diffusion spectrum imaging: reconstructing the ensemble averaged propagator (EAP) by an inverse Fourier transform. We also propose an alternative reconstruction method guaranteeing a nonnegative EAP that integrates to unity. The reconstruction is validated on data simulated from two Gaussians at various crossing angles. Moreover, we demonstrate on non-uniformly sampled in vivo data that the method is far superior to linear interpolation, and allows a drastic undersampling of the data with only a minor loss of accuracy. We envision the method as a potential replacement for standard diffusion spectrum imaging, in particular when acquistion time is limited.
△ Less
Submitted 9 November, 2016;
originally announced November 2016.
-
Can parametric statistical methods be trusted for fMRI based group studies?
Authors:
Anders Eklund,
Thomas Nichols,
Hans Knutsson
Abstract:
The most widely used task fMRI analyses use parametric methods that depend on a variety of assumptions. While individual aspects of these fMRI models have been evaluated, they have not been evaluated in a comprehensive manner with empirical data. In this work, a total of 2 million random task fMRI group analyses have been performed using resting state fMRI data, to compute empirical familywise err…
▽ More
The most widely used task fMRI analyses use parametric methods that depend on a variety of assumptions. While individual aspects of these fMRI models have been evaluated, they have not been evaluated in a comprehensive manner with empirical data. In this work, a total of 2 million random task fMRI group analyses have been performed using resting state fMRI data, to compute empirical familywise error rates for the software packages SPM, FSL and AFNI, as well as a standard non-parametric permutation method. While there is some variation, for a nominal familywise error rate of 5% the parametric statistical methods are shown to be conservative for voxel-wise inference and invalid for cluster-wise inference; in particular, cluster size inference with a cluster defining threshold of p = 0.01 generates familywise error rates up to 60%. We conduct a number of follow up analyses and investigations that suggest the cause of the invalid cluster inferences is spatial auto correlation functions that do not follow the assumed Gaussian shape. By comparison, the non-parametric permutation test, which is based on a small number of assumptions, is found to produce valid results for voxel as well as cluster wise inference. Using real task data, we compare the results between one parametric method and the permutation test, and find stark differences in the conclusions drawn between the two using cluster inference. These findings speak to the need of validating the statistical methods being used in the neuroimaging field.
△ Less
Submitted 5 November, 2015;
originally announced November 2015.