Model-based aberration corrected microscopy inside a glass tube
Authors:
D. W. S. Cox,
T. Knop,
I. M. Vellekoop
Abstract:
Microscope objectives achieve near diffraction-limited performance only when used under the conditions they are designed for. In non-standard geometries, such as thick cover slips or curved surfaces, severe aberrations arise, inevitably impairing high-resolution imaging. Correcting such large aberrations using standard adaptive optics can be challenging: existing solutions are either not suited fo…
▽ More
Microscope objectives achieve near diffraction-limited performance only when used under the conditions they are designed for. In non-standard geometries, such as thick cover slips or curved surfaces, severe aberrations arise, inevitably impairing high-resolution imaging. Correcting such large aberrations using standard adaptive optics can be challenging: existing solutions are either not suited for strong aberrations, or require extensive feedback measurements, consequently taking a significant portion of the photon budget. We demonstrate that it is possible to pre-compute the corrections needed for high-resolution imaging inside a glass tube based on a priori information only. Our ray-tracing based method achieved over an order of magnitude increase in image contrast without the need for a feedback signal.
△ Less
Submitted 22 November, 2023;
originally announced November 2023.
Model-based wavefront sha** microscopy
Authors:
Abhilash Thendiyammal,
Gerwin Osnabrugge,
Tom Knop,
Ivo M. Vellekoop
Abstract:
Wavefront sha** is increasingly being used in modern microscopy to obtain distortion-free, high-resolution images deep inside inhomogeneous media. Wavefront sha** methods typically rely on the presence of a 'guidestar' in order to find the optimal wavefront to mitigate the scattering of light. However, this condition cannot be satisfied in most biomedical applications. Here, we introduce a nov…
▽ More
Wavefront sha** is increasingly being used in modern microscopy to obtain distortion-free, high-resolution images deep inside inhomogeneous media. Wavefront sha** methods typically rely on the presence of a 'guidestar' in order to find the optimal wavefront to mitigate the scattering of light. However, this condition cannot be satisfied in most biomedical applications. Here, we introduce a novel, guidestar-free wavefront sha** method in which the optimal wavefront is computed using a digital model of the sample. The refractive index model of the sample, that serves as the input for the computation, is constructed in-situ by the microscope itself. In a proof of principle imaging experiment, we demonstrate a large improvement in the two-photon fluorescence signal through a diffuse medium, outperforming the state-of-the-art wavefront sha** techniques by a factor of 21.
△ Less
Submitted 12 February, 2020;
originally announced February 2020.