Dynamic Transition From Regular to Mach Reflection Over a Moving Wedge
Authors:
Lubna Margha,
Ahmed A. Hamada,
Doyle D. Knight,
Ahmed Eltaweel
Abstract:
The transition between the Regular Reflection (RR) and Mach Reflection (MR) phenomenon impacts the design of the supersonic and hypersonic air-breathing vehicles. The aim of this paper is to numerically investigate the dynamic transition from RR to MR of unsteady supersonic flow over a two-dimensional wedge, whose trailing edge moves along the $x$-direction upstream with a velocity, $V(t)$ at a fr…
▽ More
The transition between the Regular Reflection (RR) and Mach Reflection (MR) phenomenon impacts the design of the supersonic and hypersonic air-breathing vehicles. The aim of this paper is to numerically investigate the dynamic transition from RR to MR of unsteady supersonic flow over a two-dimensional wedge, whose trailing edge moves along the $x$-direction upstream with a velocity, $V(t)$ at a free-stream Mach number of $M_{\infty}=3$. The simulation is conducted using the unsteady compressible inviscid flow solver, which is implemented in OpenFOAM\textsuperscript{\textregistered}, the open-source CFD tool. Further, the wedge motion is applied by moving the mesh boundary, performing the Arbitrary Lagrangian-Eulerian (ALE) technique. In addition, the sonic and detachment criteria are used to define the dynamic transition from RR to MR during the increase of the wedge angle. Different reduced frequencies, $κ$, in the range of $[0.1-2]$ for the moving wedge are applied to study the lag in the dynamic transition from the steady-state condition. The results show that the critical value of $κ=0.4$ distinguishes between the rapid and gradual lag in the transition from RR to MR. In addition, the transition from RR to MR occurs above the Dual Solution Domain (DSD), since the shock is curved downstream during the rapid motion of the wedge.
△ Less
Submitted 28 February, 2023;
originally announced February 2023.
HyperSLICE: HyperBand optimized Spiral for Low-latency Interactive Cardiac Examination
Authors:
Dr. Olivier Jaubert,
Dr. Javier Montalt-Tordera,
Dr. Daniel Knight,
Pr. Simon Arridge,
Dr. Jennifer Steeden,
Pr. Vivek Muthurangu
Abstract:
PURPOSE: Interactive cardiac magnetic resonance imaging is used for fast scan planning and MR guided interventions. However, the requirement for real-time acquisition and near real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for…
▽ More
PURPOSE: Interactive cardiac magnetic resonance imaging is used for fast scan planning and MR guided interventions. However, the requirement for real-time acquisition and near real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for low-latency reconstruction (deep artifact suppression). METHODS: A variable density spiral trajectory was parametrized and optimized via HyperBand to provide the best candidate trajectory for rapid deep artifact suppression. Training data consisted of 692 breath-held CINEs. The developed interactive sequence was tested in simulations and prospectively in 13 subjects (10 for image evaluation, 2 during catheterization, 1 during exercise). In the prospective study, the optimized framework -HyperSLICE- was compared to conventional Cartesian real-time, and breath-hold CINE imaging in terms quantitative and qualitative image metrics. Statistical differences were tested using Friedman chi-squared tests with post-hoc Nemenyi test (p<0.05). RESULTS: In simulations the NRMSE, pSNR, SSIM and LAPE were all statistically significantly higher using optimized spiral compared to radial and uniform spiral sampling, particularly after scan plan changes (SSIM: 0.71 vs 0.45 and 0.43). Prospectively, HyperSLICE enabled a higher spatial and temporal resolution than conventional Cartesian real-time imaging. The pipeline was demonstrated in patients during catheter pull back showing sufficiently fast reconstruction for interactive imaging. CONCLUSION: HyperSLICE enables high spatial and temporal resolution interactive imaging. Optimizing the spiral sampling enabled better overall image quality and superior handling of image transitions compared to radial and uniform spiral trajectories.
△ Less
Submitted 16 June, 2023; v1 submitted 6 February, 2023;
originally announced February 2023.