Skip to main content

Showing 1–14 of 14 results for author: Knappe, S

.
  1. Correcting heading errors in optically pumped magnetometers through microwave interrogation

    Authors: Christopher Kiehl, Thanmay S. Menon, Dawson P. Hewatt, Svenja Knappe, Tobias Thiele, Cindy A. Regal

    Abstract: We demonstrate how to measure in situ for heading errors of optically pumped magnetometers (OPMs) in the challenging parameter regime of compact vapor cells with imperfect optical pum** and high buffer gas pressure. For this, we utilize microwave-driven Ramsey and Rabi frequency spectroscopy (FS) to independently characterize scalar heading errors in free induction decay (FID) signals. Both of t… ▽ More

    Submitted 5 July, 2024; v1 submitted 17 October, 2023; originally announced October 2023.

    Comments: 24 pages + 26 figures

    Journal ref: Phys. Rev. Applied 22, 014005 (2024)

  2. arXiv:2208.00120  [pdf, other

    physics.atom-ph

    Coherence of Rabi oscillations with spin exchange

    Authors: Chris Kiehl, Daniel Wagner, Ting-Wei Hsu, Svenja Knappe, Cindy A. Regal, Tobias Thiele

    Abstract: Rabi measurements in atomic vapor cells are of current interest in a range of microwave imaging and sensing experiments, but are increasingly in a parameter space outside of theoretical studies of coherence defined by spin-exchange collisions. Here, we study the coherence of Rabi oscillations in vapor cells by employing continuous non-destructive readout of the hyperfine manifold of $^{87}$Rb usin… ▽ More

    Submitted 29 July, 2022; originally announced August 2022.

    Comments: 6 pages, 4 figures + supplementary 15 pages, 6 figures

  3. arXiv:2105.02316  [pdf, other

    physics.ins-det physics.bio-ph physics.med-ph

    A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding

    Authors: Richard J. Clancy, Vladislav Gerginov, Orang Alem, Stephen Becker, Svenja Knappe

    Abstract: Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background fields making them ideally suited for brain imaging applications in unshielded environments. Despite a flurry of activity around the topic, questions remain co… ▽ More

    Submitted 5 May, 2021; originally announced May 2021.

    Comments: 18 pages, 9 figures

    Journal ref: Physics in Medicine and Biology, vol 66 175030, Sept 2021

  4. arXiv:1909.10921  [pdf, ps, other

    math-ph hep-th

    Stratified structure of the observable algebra of Hamiltonian lattice gauge theory

    Authors: Sebastian Knappe, Gerd Rudolph, Matthias Schmidt

    Abstract: We consider Kaehler quantized models whose underlying classical phase space has a stratified structure induced from the Hamiltonian action of a compact Lie group. We show how to implement the classical stratification on the level of the C*-algebra of observables and discuss the relation to the costratification (in the sense of Huebschmann) of the physical Hilbert space. Our analysis is based on th… ▽ More

    Submitted 9 January, 2020; v1 submitted 23 September, 2019; originally announced September 2019.

    Comments: Added new section on motivation and background, corrected and revised argument in sections 3.2 and 4.2 (revised version), added comments on the definition of stratified C*-algebra and on the role of the algebra R in section 4.2 (revised version). arXiv admin note: text overlap with arXiv:1803.11077, arXiv:1702.01047

  5. arXiv:1701.03236  [pdf, other

    physics.ins-det physics.atom-ph

    A microfabricated optically-pumped magnetic gradiometer

    Authors: Dong Sheng, Abigail R. Perry, Sean P. Krzyzewski, Shawn Geller, John Kitching, Svenja Knappe

    Abstract: We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can mea… ▽ More

    Submitted 12 January, 2017; originally announced January 2017.

    Comments: Accepted by APL

    Journal ref: Appl. Phys. Lett. 110, 031106 (2017)

  6. arXiv:1404.0374  [pdf

    physics.ins-det physics.atom-ph

    An optically modulated zero-field atomic magnetometer with suppressed spin-exchange broadening

    Authors: Ricardo Jimenez-Martinez, Svenja Knappe, John Kitching

    Abstract: We demonstrate an optically pumped $^{87}$Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the $^{87}$Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-ba… ▽ More

    Submitted 1 April, 2014; originally announced April 2014.

  7. arXiv:1401.1659  [pdf

    physics.atom-ph physics.optics quant-ph

    The hyperfine Paschen-Back Faraday effect

    Authors: Mark A Zentile, Rebecca Andrews, Lee Weller, Svenja Knappe, Charles S Adams, Ifan G Hughes

    Abstract: We investigate experimentally and theoretically the Faraday effect in an atomic medium in the hyperfine Paschen-Back regime, where the Zeeman interaction is larger than the hyperfine splitting. We use a small permanent magnet and a micro-fabricated vapour cell, giving magnetic fields of the order of a Tesla. We show that for low absorption and small rotation angles, the refractive index is well ap… ▽ More

    Submitted 26 March, 2014; v1 submitted 8 January, 2014; originally announced January 2014.

    Comments: 8 pages, 4 figures

    Journal ref: J. Phys. B: At. Mol. Opt. Phys. 47, 075005 (2014)

  8. arXiv:1401.0068  [pdf

    physics.ins-det physics.atom-ph

    Optical hyperpolarization and NMR detection of $^{129}$Xe on a microfluidic chip

    Authors: Ricardo Jimenez-Martinez, Daniel J. Kennedy, Michael Rosenbluh, Elizabeth A. Donley, Svenja Knappe, Scott J. Seltzer, Hattie L. Ring, Vikram S. Bajaj, John Kitching

    Abstract: Optically hyperpolarized $^{129}$Xe gas has become a powerful contrast agent in nuclear magnetic resonance (NMR) spectroscopy and imaging, with applications ranging from studies of the human lung to the targeted detection of biomolecules. Equally attractive is its potential use to enhance the sensitivity of microfluidic NMR experiments, in which small sample volumes yield poor sensitivity. Unfortu… ▽ More

    Submitted 30 December, 2013; originally announced January 2014.

  9. arXiv:1208.1879  [pdf, ps, other

    physics.atom-ph quant-ph

    Absolute absorption and dispersion of a rubidium vapour in the hyperfine Paschen-Back regime

    Authors: Lee Weller, Kathrin S. Kleinbach, Mark A. Zentile, Svenja Knappe, Charles S. Adams, Ifan G. Hughes

    Abstract: Here we report on measurements of the absolute absorption and dispersion properties of an isotopically pure 87Rb vapour for magnetic fields up to and including 0.6 T. We discuss the various regimes that arise when the hyperfine and Zeeman interactions have different magnitudes, and show that we enter the hyperfine Paschen- Back regime for fields greater than 0.33 T on the Rb D2 line. The experimen… ▽ More

    Submitted 9 August, 2012; originally announced August 2012.

    Journal ref: J. Phys. B: At. Mol. Opt. Phys. 45 215005 (2012)

  10. arXiv:1206.0214  [pdf, ps, other

    physics.atom-ph

    An optical isolator using an atomic vapor in the hyperfine Paschen-Back regime

    Authors: L. Weller, K. S. Kleinbach, M. A. Zentile, S. Knappe, I. G. Hughes, C. S. Adams

    Abstract: A light, compact optical isolator using an atomic vapor in the hyperfine Paschen-Back regime is presented. Absolute transmission spectra for experiment and theory through an isotopically pure 87Rb vapor cell show excellent agreement for fields of 0.6 T. We show π/4 rotation for a linearly polarized beam in the vicinity of the D2 line and achieve an isolation of 30 dB with a transmission > 95 %.

    Submitted 1 June, 2012; originally announced June 2012.

    Journal ref: Optics Letters, Vol. 37, Issue 16, pp. 3405-3407 (2012)

  11. arXiv:1107.1913  [pdf, ps, other

    physics.atom-ph physics.ins-det

    Detection of a single cobalt microparticle with a microfabricated atomic magnetometer

    Authors: Daniel Maser, Saurabh Pandey, Hattie Ring, Micah P. Ledbetter, Svenja Knappe, John Kitching, Dmitry Budker

    Abstract: We present magnetic detection of a single, 2 μm diameter cobalt microparticle using an atomic magnetometer based on a microfabricated vapor cell. These results represent an improvement by a factor of 105 in terms of the detected magnetic moment over previous work using atomic magnetometers to detect magnetic microparticles. The improved sensitivity is due largely to the use of small vapor cells. I… ▽ More

    Submitted 12 July, 2011; v1 submitted 10 July, 2011; originally announced July 2011.

    Comments: 3 pages, 3 figures

  12. arXiv:1102.5378  [pdf

    physics.chem-ph physics.atom-ph

    Parahydrogen enhanced zero-field nuclear magnetic resonance

    Authors: Thomas Theis, Paul Ganssle, Gwendal Kervern, Svenja Knappe, John Kitching, Micah Ledbetter, Dmitry Budker, Alex Pines

    Abstract: Nuclear magnetic resonance (NMR), conventionally detected in multi-tesla magnetic fields, is a powerful analytical tool for the determination of molecular identity, structure, and function. With the advent of prepolarization methods and alternative detection schemes using atomic magnetometers or superconducting quantum interference devices (SQUIDs), NMR in very low- (~earth's field), and even zero… ▽ More

    Submitted 25 February, 2011; originally announced February 2011.

    Comments: 19 pages, 4 figures

  13. arXiv:1012.3522  [pdf, ps, other

    physics.atom-ph

    Small-sized Dichroic Atomic Vapor Laser Lock (DAVLL)

    Authors: Changmin Lee, G. Z. Iwata, E. Corsini, J. M. Higbie, S. Knappe, M. P. Ledbetter, D. Budker

    Abstract: Two, lightweight diode laser frequency stabilization systems designed for experiments in the field are described. A significant reduction in size and weight in both models supports the further miniaturization of measurement devices in the field. Similar to a previous design, magnetic-field lines are contained within a magnetic shield enclosing permanent magnets and a Rb cell, so that these DAVLL s… ▽ More

    Submitted 21 July, 2012; v1 submitted 16 December, 2010; originally announced December 2010.

    Comments: 13 pages, 11 figures, published version

    Journal ref: Rev. Sci. Instrum. 82, 043107 (2011)

  14. Optical detection of NMR J-spectra at zero magnetic field

    Authors: M. P. Ledbetter, C. W. Crawford, A. Pines, D. E. Wemmer, S. Knappe, J. Kitching, D. Budker

    Abstract: Scalar couplings of the form J I_1 \cdot I_2 between nuclei impart valuable information about molecular structure to nuclear magnetic-resonance spectra. Here we demonstrate direct detection of J-spectra due to both heteronuclear and homonuclear J-coupling in a zero-field environment where the Zeeman interaction is completely absent. We show that characteristic functional groups exhibit distinct… ▽ More

    Submitted 26 January, 2009; originally announced January 2009.

    Comments: 15 pages, 4 Figures