-
MPGDs for TPCs at future lepton colliders
Authors:
Alain Bellerive,
Jochen Kaminski,
Peter M. Lewis,
Paul Colas,
Ralf Diener,
Peter Kluit,
Ronald Dean Settles,
Jan Timmermans,
Maxim Titov,
Andreas Loschcke Centeno,
Christian Wessel,
Oskar Hartbrich,
Sven Vahsen,
Carlos Marinas,
Huiron Qi,
Zhiyong Zhang
Abstract:
This submission will focus on advancements and advantages of Micro Pattern Gas Detector (MPGD) technologies and their applications to the construction of a dedicated Time Projection Chamber (TPC) that can serve as an excellent main tracker for any multipurpose detector that can be foreseen to operate at a future lepton collider. The first portion of the report will be the executive summary. It wil…
▽ More
This submission will focus on advancements and advantages of Micro Pattern Gas Detector (MPGD) technologies and their applications to the construction of a dedicated Time Projection Chamber (TPC) that can serve as an excellent main tracker for any multipurpose detector that can be foreseen to operate at a future lepton collider. The first portion of the report will be the executive summary. It will be followed by sections detailing the applications of MPGDs specifically to the construction of the LCTPC for the ILD at ILC, for a possible upgrade of the Belle II detector at SuperKEKB and for the design of a TPC for a detector at CEPC. MPGD technologies offer synergies with other detector R&D and several application domains; a few examples will be provided in the context of the ongoing Snowmass long range planning exercise in the USA. Links to industrial partnership and work with institutions in the USA will be highlighted when appropriate.
△ Less
Submitted 15 March, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Performance of the GridPix detector quad
Authors:
Cornelis Ligtenberg,
Yevgen Bilevych,
Klaus Desch,
Harry van der Graaf,
Markus Gruber,
Fred Hartjes,
Kevin Heijhoff,
Jochen Kaminski,
Peter M. Kluit,
Naomi van der Kolk,
Gerhard Raven,
Tobias Schiffer,
Jan Timmermans
Abstract:
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation elec…
▽ More
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation electrons, which enable to make a precise track position measurement. A quad module was installed in a small time projection chamber and measurements of 2.5 GeV electrons were performed at the ELSA accelerator in Bonn, where a silicon telescope was used to provide a reference track. The error on the track position measurement, both in the pixel plane and drift direction, is dominated by diffusion. The quad was designed to have minimum electrical field inhomogeneities and distortions, achieving systematics of better than 13 $μ$m in the pixel plane. The resolution of the setup is 41 $μ$m, where the total systematic error of the quad detector is 24 $μ$m.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
Performance of a GridPix TPC readout based on the Timepix3 chip
Authors:
C. Ligtenberg,
K. Heijhoff,
Y. Bilevych,
K. Desch,
H. van der Graaf,
M. Gruber,
F. Hartjes,
J. Kaminski,
N. van der Kolk,
P. M. Kluit,
G. Raven,
L. Scharenberg,
T. Schiffer,
S. Schmidt,
J. Timmermans
Abstract:
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the reado…
▽ More
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the readout plane is dominated by diffusion. Systematic uncertainties are limited to below 10 $μ$m. The GridPix can detect single ionization electrons with high efficiency, which allows for energy loss measurements and particle identification. From a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m. Using the same type of chips, a Quad module was developed that can be tiled to cover a TPC readout plane at the ILC. Simulation studies show that a pixel readout can improve the momentum resolution of a TPC at the ILC by about 20%.
△ Less
Submitted 5 February, 2019;
originally announced February 2019.
-
Performance of a GridPix detector based on the Timepix3 chip
Authors:
C. Ligtenberg,
K. Heijhoff,
Y. Bilevych,
K. Desch,
H. van der Graaf,
F. Hartjes,
J. Kaminski,
P. M. Kluit,
G. Raven,
T. Schiffer,
J. Timmermans
Abstract:
A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification grid. Its performance is studied in a test beam with 2.5 GeV electrons. The GridPix detector detects single ionization electrons with high efficiency. The Timepix…
▽ More
A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification grid. Its performance is studied in a test beam with 2.5 GeV electrons. The GridPix detector detects single ionization electrons with high efficiency. The Timepix3 chip allowed for high sample rates and time walk corrections. Diffusion is found to be the dominating error on the track position measurement both in the pixel plane and in the drift direction, and systematic distortions in the pixel plane are below 10 $μ$m. Using a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m.
△ Less
Submitted 22 August, 2018; v1 submitted 14 August, 2018;
originally announced August 2018.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.
-
The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit
Authors:
M. Campbell,
M. Chefdeville,
P. Colas,
A. P. Colijn,
A. Fornaini,
Y. Giomataris,
H. van der Graaf,
E. H. M Heijne,
P. Kluit,
X. Llopart,
J. Schmitz,
J. Timmermans,
J. L. Visschers
Abstract:
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames cont…
▽ More
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames containing 2D images with tracks from cosmic muons. Along these tracks, electron clusters were observed, as well as delta-rays.
△ Less
Submitted 9 September, 2004;
originally announced September 2004.