-
High-speed and wide-field nanoscale table-top ptychographic EUV imaging and beam characterization with a sCMOS detector
Authors:
Wilhelm Eschen,
Chang Liu,
Daniel S. Penagos Molina,
Robert Klas,
Jens Limpert,
Jan Rothhardt
Abstract:
We present high-speed and wide-field EUV ptychography at 13.5 nm wavelength using a table-top high-order harmonic source. By employing a scientific complementary metal oxide semiconductor (sCMOS) detector the scan time for sub-20 nm high-resolution measurements were significantly reduced by up to a factor of five. The fast frame rate of sCMOS enables wide-field imaging with a field of view of 100…
▽ More
We present high-speed and wide-field EUV ptychography at 13.5 nm wavelength using a table-top high-order harmonic source. By employing a scientific complementary metal oxide semiconductor (sCMOS) detector the scan time for sub-20 nm high-resolution measurements were significantly reduced by up to a factor of five. The fast frame rate of sCMOS enables wide-field imaging with a field of view of 100 μm x 100 μm with an imaging speed of 4.6 Mpix/h. Furthermore, fast EUV wavefront characterization is employed using a combination of the sCMOS detector with orthogonal probe relaxation.
△ Less
Submitted 26 January, 2023;
originally announced February 2023.
-
Visualizing the ultra-structure of microorganisms using table-top extreme ultraviolet imaging
Authors:
Chang Liu,
Wilhelm Eschen,
Lars Loetgering,
Daniel S. Molina,
Robert Klas,
Alexander Iliou,
Michael Steinert,
Sebastian Herkersdorf,
Alexander Kirsche,
Thomas Pertsch,
Falk Hillmann,
Jens Limpert,
Jan Rothhardt
Abstract:
Table-top extreme ultraviolet (EUV) microscopy offers unique opportunities for label-free investigation of biological samples. Here, we demonstrate ptychographic EUV imaging of two dried, unstained model specimens: germlings of a fungus (Aspergillus nidulans), and bacteria (Escherichia coli) cells at 13.5 nm wavelength. We find that the EUV spectral region, which to date has not received much atte…
▽ More
Table-top extreme ultraviolet (EUV) microscopy offers unique opportunities for label-free investigation of biological samples. Here, we demonstrate ptychographic EUV imaging of two dried, unstained model specimens: germlings of a fungus (Aspergillus nidulans), and bacteria (Escherichia coli) cells at 13.5 nm wavelength. We find that the EUV spectral region, which to date has not received much attention for biological imaging, offers sufficient penetration depths for the identification of intracellular features. By implementing a position-correlated ptychography approach, we demonstrate a millimeter-squared field of view enabled by infrared illumination combined with sub-60 nm spatial resolution achieved with EUV illumination on selected regions of interest. The strong element contrast at 13.5 nm wavelength enables the identification of the nanoscale material composition inside the specimens. Our work will advance and facilitate EUV imaging applications and enable further possibilities in life science.
△ Less
Submitted 8 November, 2022;
originally announced November 2022.
-
Enhancement of supercurrent through ferromagnetic materials by interface engineering
Authors:
Swapna Sindhu Mishra,
Robert M. Klaes,
Joshua Willard,
Reza Loloee,
Norman O. Birge
Abstract:
Josephson junctions containing ferromagnetic materials exhibit interesting physics and show promise as circuit elements for superconducting logic and memory. For memory applications, the properties of the junction should be controllable by changing the magnetic configuration inside the junction. To achieve good magnetic switching properties, one should choose a soft magnetic material such as NiFe…
▽ More
Josephson junctions containing ferromagnetic materials exhibit interesting physics and show promise as circuit elements for superconducting logic and memory. For memory applications, the properties of the junction should be controllable by changing the magnetic configuration inside the junction. To achieve good magnetic switching properties, one should choose a soft magnetic material such as NiFe (permalloy); however, NiFe exhibits poor supercurrent transmission in Josephson junctions. In this work we put thin layers of Ni on either side of the NiFe and characterize the magnetic behavior and supercurrent transmission properties of the Ni/NiFe/Ni trilayers as a function of Ni and NiFe thicknesses. Using a Ni thickness of 0.4 nm, we find that the magnetic switching behavior of the trilayers is not severely degraded relative to plain NiFe, while the maximum supercurrent in the $π$-state of the trilayer Josephson junctions is increased by a factor of four relative to that of NiFe junctions. We speculate that the supercurrent enhancement is due to the different spin-dependent transport properties of the Cu/Ni and Cu/NiFe interfaces.
△ Less
Submitted 15 July, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Material-specific high-resolution table-top extreme ultraviolet microscopy
Authors:
Wilhelm Eschen,
Lars Loetgering,
Vittoria Schuster,
Robert Klas,
Alexander Kirsche,
Lutz Berthold,
Michael Steinert,
Thomas Pertsch,
Herbert Gross,
Michael Krause,
Jens Limpert,
Jan Rothhardt
Abstract:
Microscopy with extreme ultraviolet (EUV) radiation holds promise for high-resolution imaging with excellent material contrast, due to the short wavelength and numerous element-specific absorption edges available in this spectral range. At the same time, EUV radiation has significantly larger penetration depths than electrons. It thus enables a nano-scale view into complex three-dimensional struct…
▽ More
Microscopy with extreme ultraviolet (EUV) radiation holds promise for high-resolution imaging with excellent material contrast, due to the short wavelength and numerous element-specific absorption edges available in this spectral range. At the same time, EUV radiation has significantly larger penetration depths than electrons. It thus enables a nano-scale view into complex three-dimensional structures that are important for material science, semiconductor metrology, and next-generation nano-devices. Here, we present high-resolution and material-specific microscopy at 13.5 nm wavelength. We combine a highly stable, high photon-flux, table-top EUV source with an interferometrically stabilized ptychography setup. By utilizing structured EUV illumination, we overcome the limitations of conventional EUV focusing optics and demonstrate high-resolution microscopy at a half-pitch lateral resolution of 16 nm. Moreover, we propose mixed-state orthogonal probe relaxation ptychography, enabling robust phase-contrast imaging over wide fields of view and long acquisition times. In this way, the complex transmission of an integrated circuit is precisely reconstructed, allowing for the classification of the material composition of mesoscopic semiconductor systems.
△ Less
Submitted 24 December, 2021;
originally announced December 2021.
-
Table-top interferometry on extreme time and wavelength scales
Authors:
S. Skruszewicz,
A. Przystawik,
D. Schwickert,
M. Sumfleth,
M. Namboodiri,
V. Hilbert,
R. Klas,
P. Gierschke,
V. Schuster,
A. Vorobiov,
C. Haunhorst,
D. Kip,
J. Limpert,
J. Rothhardt,
T. Laarmann
Abstract:
High-resolution Fourier-transform spectroscopy using table-top sources in the extreme ultraviolet (XUV) spectral range is still in its infancy. In this contribution a significant advance is presented based on a Michelson-type all-reflective split-and-delay autocorrelator operating in a quasi amplitude splitting mode. The autocorrelator works under a grazing incidence angle in a broad spectral rang…
▽ More
High-resolution Fourier-transform spectroscopy using table-top sources in the extreme ultraviolet (XUV) spectral range is still in its infancy. In this contribution a significant advance is presented based on a Michelson-type all-reflective split-and-delay autocorrelator operating in a quasi amplitude splitting mode. The autocorrelator works under a grazing incidence angle in a broad spectral range $\mathrm{(10\,nm - 1\,μm)}$ providing collinear propagation of both pulse replicas and thus a constant phase difference across the beam profile. The compact instrument allows for XUV pulse autocorrelation measurements in the time domain with a single-digit attosecond precision resulting in a resolution of $\mathrm{E/ΔE=2000}$. Its performance for spectroscopic applications is demonstrated by characterizing a very sharp electronic transition at $\mathrm{26.6\,eV}$ in Ar gas induced by the $\mathrm{11^{th}}$ harmonic of a frequency-doubled Yb-fiber laser leading to the characteristic $\mathrm{3s3p^{6}4p^{1}P^{1}}$ Fano-resonance of Ar atoms. We benchmark our time-domain interferometry results with a high-resolution XUV grating spectrometer and find an excellent agreement. The common-path interferometer opens up new opportunities for short-wavelength femtosecond and attosecond pulse metrology and dynamic studies on extreme time scales in various research fields.
△ Less
Submitted 29 October, 2021; v1 submitted 1 June, 2021;
originally announced June 2021.
-
Investigation of spatiotemporal output beam profile instabilities from differentially pumped capillaries
Authors:
Martin Gebhardt,
Emmanuel B. Amuah,
Robert Klas,
Henning Stark,
Joachim Buldt,
Albrecht Steinkopff,
Jens Limpert
Abstract:
Differentially pumped capillaries, i.e., capillaries operated in a pressure gradient environment, are widely used for nonlinear pulse compression. In this work, we show that strong pressure gradients and high gas throughputs can cause spatiotemporal instabilities of the output beam profile. The instabilities occur with a sudden onset as the flow evolves from laminar to turbulent. Based on the expe…
▽ More
Differentially pumped capillaries, i.e., capillaries operated in a pressure gradient environment, are widely used for nonlinear pulse compression. In this work, we show that strong pressure gradients and high gas throughputs can cause spatiotemporal instabilities of the output beam profile. The instabilities occur with a sudden onset as the flow evolves from laminar to turbulent. Based on the experimental and numerical results, we derive guidelines to predict the onset of those instabilities and discuss possible applications in the context of nonlinear flow dynamics.
△ Less
Submitted 25 February, 2021;
originally announced February 2021.
-
Temporal contrast enhancement of energeticlaser pulses by filtered self-phase-modulation broadened spectra
Authors:
Joachim Buldt,
Michael Mueller,
Robert Klas,
Tino Eidam,
Jens Limpert,
Andreas Tuennermann
Abstract:
We present a novel approach for temporal contrast enhancement of energetic laserpulses by filtered SPM broadened spectra. A measured temporal contrast enhancement by at least 7 orders of magnitude in a simple setup has been achieved. This technique is applicable to a wide range of laser parameters and poses a highly efficient alternative to existing contrast-enhancement methods.
We present a novel approach for temporal contrast enhancement of energetic laserpulses by filtered SPM broadened spectra. A measured temporal contrast enhancement by at least 7 orders of magnitude in a simple setup has been achieved. This technique is applicable to a wide range of laser parameters and poses a highly efficient alternative to existing contrast-enhancement methods.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
High-average-power femtosecond laser at 258 nm
Authors:
Michael Müller,
Arno Klenke,
Thomas Gottschall,
Robert Klas,
Carolin Rothhardt,
Stefan Demmler,
Jan Rothhardt,
Jens Limpert,
Andreas Tünnermann
Abstract:
We present an ultrafast fiber laser system delivering 4.6 W average power at 258 nm based on two-stage fourth-harmonic generation in beta barium borate (BBO). The beam quality is close to diffraction limited with an M2- value of 1.3 x 1.6. The pulse duration is 150 fs, which potentially is compressible down to 40 fs. A plain BBO and a Sapphire-BBO compound are compared with respect to the achievab…
▽ More
We present an ultrafast fiber laser system delivering 4.6 W average power at 258 nm based on two-stage fourth-harmonic generation in beta barium borate (BBO). The beam quality is close to diffraction limited with an M2- value of 1.3 x 1.6. The pulse duration is 150 fs, which potentially is compressible down to 40 fs. A plain BBO and a Sapphire-BBO compound are compared with respect to the achievable beam quality in the conversion process. This laser is applicable in scientific and industrial fields. Further scaling to higher average power is discussed
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Energetic sub-2-cycle laser with 220 W average power
Authors:
Steffen Hädrich,
Marco Kienel,
Michael Müller,
Arno Klenke,
Jan Rothhardt,
Robert Klas,
Thomas Gottschall,
Tino Eidam,
András Drozdy,
Péter Jójárt,
Zoltán Várallyay,
Eric Cormier,
Károly Osvay,
Andreas Tünnermann,
Jens Limpert
Abstract:
Few-cycle lasers are essential for many research areas such as attosecond physics that promises to address fundamental questions in science and technology. Therefore, further advancements are connected to significant progress in the underlying laser technology. Here, two-stage nonlinear compression of a 660 W femtosecond fiber laser system is utilized to achieve unprecedented average power levels…
▽ More
Few-cycle lasers are essential for many research areas such as attosecond physics that promises to address fundamental questions in science and technology. Therefore, further advancements are connected to significant progress in the underlying laser technology. Here, two-stage nonlinear compression of a 660 W femtosecond fiber laser system is utilized to achieve unprecedented average power levels of energetic ultrashort or even few-cycle laser pulses. In a first compression step 408 W, 320 uJ, 30fs pulses are achieved, which can be further compressed to 216 W, 170 uJ, 6.3 fs pulses in a second compression stage. This is the highest average power few-cycle laser system presented so far. It is expected to significantly advance the fields of high harmonic generation and attosecond science.
△ Less
Submitted 20 January, 2021;
originally announced January 2021.
-
Agile spectral tuning of high order harmonics by inteference of two driving pulses
Authors:
Vittoria Schuster,
Vinzenz Hilbert,
Robert Klas,
Jan Rothhardt,
Jens Limpert
Abstract:
In this work the experimental realization of a tunable high photon flux extreme ultraviolet light source is presented. This is enabled by high harmonic generation of two temporally delayed driving pulses, resulting in a tuning range of 0.8 eV at the 19th harmonic at 22.8 eV. The implemented approach allows for fast tuning of the spectrum, is highly flexible and is scalable towards full spectral co…
▽ More
In this work the experimental realization of a tunable high photon flux extreme ultraviolet light source is presented. This is enabled by high harmonic generation of two temporally delayed driving pulses, resulting in a tuning range of 0.8 eV at the 19th harmonic at 22.8 eV. The implemented approach allows for fast tuning of the spectrum, is highly flexible and is scalable towards full spectral coverage at higher photon energies.
△ Less
Submitted 11 January, 2021;
originally announced January 2021.
-
Ultra-short-pulse high-average-power Megahertz-repetition-rate coherent extreme-ultraviolet light source
Authors:
R. Klas,
A. Kirsche,
M. Gebhardt,
J. Buldt,
H. Stark,
S. Hädrich,
J. Rothhardt,
J. Limpert
Abstract:
High harmonic generation (HHG) enables coherent extreme-ultraviolet (XUV) radiation with ultra-short pulse duration in a table-top setup. This has already enabled a plethora of applications. Nearly all of these applications would benefit from a high photon flux to increase the signal-to-noise ratio and decrease measurement times. In addition, shortest pulses are desired to investigate fastest dyna…
▽ More
High harmonic generation (HHG) enables coherent extreme-ultraviolet (XUV) radiation with ultra-short pulse duration in a table-top setup. This has already enabled a plethora of applications. Nearly all of these applications would benefit from a high photon flux to increase the signal-to-noise ratio and decrease measurement times. In addition, shortest pulses are desired to investigate fastest dynamics in fields as diverse as physics, biology, chemistry and material sciences. In this work, the up-to-date most powerful table-top XUV source with 12.9 mW in a single harmonic line at 26.5 eV is demonstrated via HHG of a frequency-doubled and post-compressed fibre laser. At the same time sub-6 fs XUV pulse duration allows accessing ultrafast dynamics with an order of magnitude higher photon flux than previously demonstrated. This concept will greatly advance and facilitate applications of XUV radiation in science and technology and enable photon-hungry ultrafast studies.
△ Less
Submitted 21 December, 2020;
originally announced December 2020.
-
Bright, high-repetition-rate water window soft X-ray source enabled by nonlinear pulse self-compression in an antiresonant hollow-core fibre
Authors:
M. Gebhardt,
T. Heuermann,
R. Klas,
C. Liu,
A. Kirsche,
M. Lenski,
Z. Wang,
C. Gaida,
J. E. Antonio-Lopez,
A. Schülzgen,
R. Amezcua-Correa,
J. Rothhardt,
J. Limpert
Abstract:
Bright, coherent soft X-ray (SXR) radiation is essential to a variety of applications in fundamental research and life sciences. So far, high photon flux in this spectral region can only be delivered by synchrotrons, free electron lasers or high-order harmonic generation (HHG) sources, which are driven by kHz-class repetition rate lasers with very high peak powers. Here, we establish a novel route…
▽ More
Bright, coherent soft X-ray (SXR) radiation is essential to a variety of applications in fundamental research and life sciences. So far, high photon flux in this spectral region can only be delivered by synchrotrons, free electron lasers or high-order harmonic generation (HHG) sources, which are driven by kHz-class repetition rate lasers with very high peak powers. Here, we establish a novel route toward powerful and easy-to-use SXR sources by presenting a compact experiment, in which nonlinear pulse self-compression to the few-cycle regime is combined with phase-matched HHG in a single, helium-filled antiresonant hollow-core fibre (ARHCF). This enables the first 100 kHz-class repetition rate, table-top SXR source, that delivers an application-relevant flux of 2.8*10^6 Photons/s/eV around 300 eV. The fibre-integration of temporal pulse self-compression (leading to the formation of the necessary strong-field waveforms) and pressure controlled phase-matching will allow compact, high repetition rate laser technology, including commercially available systems, to drive simple and cost-effective, coherent high-flux SXR sources.
△ Less
Submitted 16 February, 2021; v1 submitted 23 September, 2020;
originally announced September 2020.
-
Ultraviolet Dual Comb Spectroscopy: A Roadmap
Authors:
Vittoria Schuster,
Chang Liu,
Robert Klas,
Pablo Dominguez,
Jan Rothhardt,
Jens Limpert,
Birgitta Bernhardt
Abstract:
Dual Comb Spectroscopy proved its versatile capabilities in molecular fingerprinting in different spectral regions, but not yet in the ultraviolet (UV). Unlocking this spectral window would expand fingerprinting to the electronic energy structure of matter.This will access the prime triggers of photo-chemical reactions with unprecedented spectral resolution. In this research article, we discuss th…
▽ More
Dual Comb Spectroscopy proved its versatile capabilities in molecular fingerprinting in different spectral regions, but not yet in the ultraviolet (UV). Unlocking this spectral window would expand fingerprinting to the electronic energy structure of matter.This will access the prime triggers of photo-chemical reactions with unprecedented spectral resolution. In this research article, we discuss the milestones marking the way to the first UV dual comb spectrometer. We present experimental and simulated studies towards UV dual comb spectroscopy, directly applied to planned absorption measurements of formaldehyde (centered at 343 nm, 3.6 eV) and argon (80 nm, 16 eV). This will enable an unparalleled relative resolution of up to $10^{-9}$ - with a table-top UV source surpassing any synchrotron linked spectrometer by at least two and any grating-based UV spectrometer by up to six orders of magnitude.
△ Less
Submitted 1 July, 2021; v1 submitted 5 June, 2020;
originally announced June 2020.
-
Wavelength-scale ptychographic coherent diffractive imaging using a high-order harmonic source
Authors:
Getnet K. Tadesse,
Wilhelm Eschen,
Robert Klas,
Maxim Tschernajew,
Frederik Tuitje,
Michael Steinert,
Matthias Zilk,
Vittoria Schuster,
Thomas Pertsch,
Christian Spielmann,
Jens Limpert,
Jan Rothhardt
Abstract:
Ptychography enables coherent diffractive imaging (CDI) of extended samples by raster scanning across the illuminating XUV/X-ray beam thereby generalizing the unique advantages of CDI techniques. Table-top realizations of this method are urgently needed for many applications in sciences and industry. Previously, it was only possible to image features much larger than the illuminating wavelength wi…
▽ More
Ptychography enables coherent diffractive imaging (CDI) of extended samples by raster scanning across the illuminating XUV/X-ray beam thereby generalizing the unique advantages of CDI techniques. Table-top realizations of this method are urgently needed for many applications in sciences and industry. Previously, it was only possible to image features much larger than the illuminating wavelength with table-top ptychography although knife-edge tests suggested sub-wavelength resolution. However, most real-world imaging applications require resolving of the smallest and closely-spaced features of a sample in an extended field of view. In this work, we resolve features as small as 2.5 λ(45 nm) by using a table-top ptychography setup and a high-order harmonic XUV source. For the first time, a Rayleigh-type criterion is used as a direct and unambiguous resolution metric for high-resolution table-top setup. This reliably qualifies this imaging system for real-world applications e.g. in biological sciences, material sciences, imaging integrated circuits and semiconductor mask inspection.
△ Less
Submitted 24 May, 2018;
originally announced May 2018.
-
Table-Top Milliwatt-Class Extreme Ultraviolet High Harmonic Light Source
Authors:
Robert Klas,
Stefan Demmler,
Maxim Tschernajew,
Steffen Hädrich,
Yariv Shamir,
Andreas Tünnermann,
Jan Rothhardt,
Jens Limpert
Abstract:
Extreme ultraviolet (XUV) lasers are essential for the investigation of fundamental physics. Especially high repetition rate, high photon flux sources are of major interest for reducing acquisition times and improving signal to noise ratios in a plethora of applications. Here, an XUV source based on cascaded frequency conversion is presented, which delivers due to the drastic better single atom re…
▽ More
Extreme ultraviolet (XUV) lasers are essential for the investigation of fundamental physics. Especially high repetition rate, high photon flux sources are of major interest for reducing acquisition times and improving signal to noise ratios in a plethora of applications. Here, an XUV source based on cascaded frequency conversion is presented, which delivers due to the drastic better single atom response for short wavelength drivers, an average output power of (832 +- 204) μW at 21.7 eV. This is the highest average power produced by any HHG source in this spectral range surpassing precious demonstrations by more than a factor of four. Furthermore, a narrow-band harmonic at 26.6 eV with a relative energy bandwidth of only ΔE/E= 1.8 x 10E-3 has been generated, which is of high interest for high precision spectroscopy experiments.
△ Less
Submitted 11 July, 2016;
originally announced July 2016.
-
High Speed and High Resolution Table-Top Nanoscale Imaging
Authors:
G. K. Tadesse,
R. Klas,
S. Demmler,
S. HÄdrich,
I. Wahyutama,
M. Steinert,
C. Spielmann,
M. ZÜrch,
A. TÜnnermann,
J. Limpert,
J. Rothhardt
Abstract:
We present a table-top coherent diffraction imaging (CDI) experiment based on high-order harmonics generated at 18 nm by a high average power femtosecond fiber laser system. The high photon flux, narrow spectral bandwidth and high degree of spatial coherence allow for ultra-high sub-wavelength resolution imaging at a high numerical aperture. Our experiments demonstrate a half-pitch resolution of 1…
▽ More
We present a table-top coherent diffraction imaging (CDI) experiment based on high-order harmonics generated at 18 nm by a high average power femtosecond fiber laser system. The high photon flux, narrow spectral bandwidth and high degree of spatial coherence allow for ultra-high sub-wavelength resolution imaging at a high numerical aperture. Our experiments demonstrate a half-pitch resolution of 13.6 nm, very close to the actual Abbe-limit of 12.4 nm, which is the highest resolution achieved from any table-top XUV or X-ray microscope. In addition, 20.5 nm resolution was achieved with only 3 sec of integration time bringing live diffraction imaging and 3D tomography on the nanoscale one step closer to reality. The current resolution is solely limited by the wavelength and the detector size. Thus, table-top nanoscopes with only a few-nm resolutions are in reach and will find applications in many areas of science and technology.
△ Less
Submitted 10 May, 2016;
originally announced May 2016.
-
High-repetition-rate and high-photon-flux 70 eV high-harmonic source for coincidence ion imaging of gas-phase molecules
Authors:
Jan Rothhardt,
Steffen Hädrich,
Yariv Shamir,
Maxim Tschnernajew,
Robert Klas,
Armin Hoffmann,
Getnet K. Tadesse,
Arno Klenke,
Thomas Gottschall,
Tino Eidam,
Jens Limpert,
Andreas Tünnermann,
Rebecca Boll,
Cedric Bomme,
Hatem Dachraoui,
Benjamin Erk,
Michele Di Fraia,
Daniel A. Horke,
Thomas Kierspel,
Terence Mullins,
Andreas Przystawik,
Evgeny Savelyev,
Joss Wiese,
Tim Laarmann,
Jochen Küpper
, et al. (1 additional authors not shown)
Abstract:
Unraveling and controlling chemical dynamics requires techniques to image structural changes of molecules with femtosecond temporal and picometer spatial resolution. Ultrashort-pulse x-ray free-electron lasers have significantly advanced the field by enabling advanced pump-probe schemes. There is an increasing interest in using table-top photon sources enabled by high-harmonic generation of ultras…
▽ More
Unraveling and controlling chemical dynamics requires techniques to image structural changes of molecules with femtosecond temporal and picometer spatial resolution. Ultrashort-pulse x-ray free-electron lasers have significantly advanced the field by enabling advanced pump-probe schemes. There is an increasing interest in using table-top photon sources enabled by high-harmonic generation of ultrashort-pulse lasers for such studies. We present a novel high-harmonic source driven by a 100 kHz fiber laser system, which delivers 10$^{11}$ photons/s in a single 1.3 eV bandwidth harmonic at 68.6 eV. The combination of record-high photon flux and high repetition rate paves the way for time-resolved studies of the dissociation dynamics of inner-shell ionized molecules in a coincidence detection scheme. First coincidence measurements on CH$_3$I are shown and it is outlined how the anticipated advancement of fiber laser technology and improved sample delivery will, in the next step, allow pump-probe studies of ultrafast molecular dynamics with table-top XUV-photon sources. These table-top sources can provide significantly higher repetition rates than the currently operating free-electron lasers and they offer very high temporal resolution due to the intrinsically small timing jitter between pump and probe pulses.
△ Less
Submitted 28 April, 2016; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Exceptional H_2 emission in the Antennae galaxies: Pre-starburst shocks from the galaxy collision
Authors:
Martin Haas Rolf Chini Ulrich Klaas
Abstract:
The collision of gas-rich galaxies is believed to produce strong shocks between their gas clouds which cause the onset of the observed bursts of extended star formation. However, the so far observed shock signatures in colliding galaxies can be explained essentially by winds from already existing massive stars and supernovae and thus do not give any evidence for an outstanding pre-starburst phas…
▽ More
The collision of gas-rich galaxies is believed to produce strong shocks between their gas clouds which cause the onset of the observed bursts of extended star formation. However, the so far observed shock signatures in colliding galaxies can be explained essentially by winds from already existing massive stars and supernovae and thus do not give any evidence for an outstanding pre-starburst phase. Either pre-starburst gas shocks are too short-lived to be detected or one has to modify our perception of colliding galaxies. A dedicated analysis of ISOCAM-CVF mid-infrared spectral maps led us to the discovery of exceptional H_2 v=0-0 S(3) lambda = 9.66 um line emission from the "Antennae" galaxy pair, which is at an early stage of galaxy collision. Its H_2 line luminosity, normalized by the far-infrared luminosity, exceeds that of all other known galaxies and the strongest H_2 emission is spatially displaced from the known starbursts regions. This implies that most of the excited H_2 gas in the Antennae must be shocked due to the collision of the two galaxies. These observations indicate that the outstanding phase of pre-starburst shocks exists, and that they might be a key to our understanding of the formation of the first proto-galaxies.
△ Less
Submitted 22 February, 2005;
originally announced February 2005.