-
Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast
Authors:
James A. Pollock,
Kaye Morgan,
Linda C. P. Croton,
Emily J. Pryor,
Kelly J. Crossley,
Christopher J. Hall,
Daniel Hausermann,
Anton Maksimenko,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in imag…
▽ More
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in image resolution at equal or lower radiation levels than current clinical imaging. Propagation-based phase-contrast imaging requires minimal adaption of existing medical systems, and is well suited to lung imaging due to the strong phase gradients introduced by the lung-air material interface. Herein, propagation-based phase contrast CT is demonstrated for large animals, namely lambs, as a model for paediatric patients, using monochromatic radiation and a photon-counting detector at the Imaging and Medical Beamline of the Australian Synchrotron. Image quality, normalised against radiation dose, was optimised as a function of the beam energy and propagation distance, with the optimal conditions used to test the available image quality at very low radiation dose. Noise-limited spatial resolution was measured using Fourier ring correlation, and dosimetry was performed through Monte Carlo simulation calibrated against air kerma. The resulting CT images demonstrate superior resolution to existing high-resolution CT systems, pushing dose to the quantum limit to comply with current Australian guidelines for infant chest CT exposure (<2.5 mSv effective dose). Constituent raw projections are shown to have significant proportions of pixels with zero photon counts that would create severe information loss in conventional CT, which was prevented through phase retrieval.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
X-ray dark-field via spectral propagation-based imaging
Authors:
Jannis N. Ahlers,
Konstantin M. Pavlov,
Marcus J. Kitchen,
Kaye S. Morgan
Abstract:
Dark-field X-ray imaging is a novel modality which visualises scattering from unresolved microstructure. Most dark-field imaging techniques rely on crystals or structured illumination, but recent work has shown that dark-field effects are observable in straightforward propagation-based imaging (PBI). Based on the single-material X-ray Fokker--Planck equation with an a priori dark-field energy depe…
▽ More
Dark-field X-ray imaging is a novel modality which visualises scattering from unresolved microstructure. Most dark-field imaging techniques rely on crystals or structured illumination, but recent work has shown that dark-field effects are observable in straightforward propagation-based imaging (PBI). Based on the single-material X-ray Fokker--Planck equation with an a priori dark-field energy dependence, we propose an algorithm to extract phase and dark-field effects from dual-energy PBI images. We successfully apply the dark-field retrieval algorithm to simulated and experimental dual-energy data, and show that by accounting for dark-field effects, projected thickness reconstruction is improved compared to the classic Paganin algorithm. With the emergence of spectral detectors, the method could enable single-exposure dark-field imaging of dynamic and living samples.
△ Less
Submitted 8 July, 2024; v1 submitted 27 September, 2023;
originally announced September 2023.
-
Robust propagation-based phase retrieval for CT in proximity to highly attenuating objects
Authors:
J. A. Pollock,
L. C. P. Croton,
K. S. Morgan,
K. J. Crossley,
M. J. Wallace,
G. A. Buckley,
S. B. Hooper,
M. J. Kitchen
Abstract:
X-ray imaging is a fast, precise and non-invasive method of imaging which, combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via material-specific phase retrieval filters, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-mate…
▽ More
X-ray imaging is a fast, precise and non-invasive method of imaging which, combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via material-specific phase retrieval filters, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-material phantoms complicates analysis by requiring a choice of which material boundary to tune the phase retrieval. Filtering for the boundary with strongest phase contrast increases noise suppression, but with the detriment of over-blurring other interfaces, potentially obscuring small or neighbouring features and removing quantitative sample information. Additionally, regions bounded by more than one material type inherently cannot be conventionally filtered to reconstruct the whole boundary. As remedy, we present a computationally-efficient, non-iterative nor AI-mediated method for applying strong phase retrieval, whilst preserving sharp boundaries for all materials within the sample. This technique was tested on phase contrast images of a rabbit kitten brain encased by the surrounding dense skull. Using 24 keV synchrotron radiation with a 5 m propagation distance, our technique provided a 6.9-fold improvement in the signal-to-noise ratio (SNR) of brain tissue compared to the standard phase retrieval procedure, without over-smoothing the images. Simultaneous quantification of edge resolution and SNR gain was performed with an aluminium-water phantom imaged using a microfocus X-ray tube at mean energy 19.58 keV and 0.576 m effective propagation distance. Our method provided a 4.2-fold SNR boost whilst preserving the boundary resolution at 54 $\pm$ 1 $μ$m, compared to 108 $\pm$ 2 $μ$m in conventional phase retrieval.
△ Less
Submitted 29 January, 2023;
originally announced January 2023.
-
Accurate measures of regional lung air volumes from chest X-rays of small animals
Authors:
D. W. O'Connell,
K. S. Morgan,
G. Ruben,
L. C. P. Croton,
J. A. Pollock,
M. K. Croughan,
E. V. McGillick,
M. J. Wallace,
K. J. Crossley,
E. J. Pryor,
R. A. Lewis,
S. B. Hooper,
M. J. Kitchen
Abstract:
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes sho…
▽ More
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes showed a strong correlation ($R^2$=0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from X-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. This method is suitable for biomedical research studies and shows potential for clinical application.
△ Less
Submitted 7 April, 2022; v1 submitted 16 February, 2022;
originally announced February 2022.
-
Precise phase retrieval for propagation-based images using discrete mathematics
Authors:
J. A. Pollock,
K. S. Morgan,
L. C. P. Croton,
M. K. Croughan,
G. Ruben,
N. Yagi,
H. Sekiguchi,
M. J. Kitchen
Abstract:
The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous…
▽ More
The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous mathematics, which can result in a loss in spatial resolution in the reconstructed images. Herein we investigate how phase retrieval algorithms for propagation-based phase-contrast X-ray imaging can be rederived using discrete mathematics and result in more precise retrieval for single- and multi-material objects and for spectral image decomposition. We validate this theory through experimental measurements of spatial resolution using computed tomography (CT) reconstructions of plastic phantoms and biological tissue, using detectors with a range of imaging system point spread functions (PSFs). We demonstrate that if the PSF substantially suppresses high spatial frequencies, the potential improvement from utilising the discrete derivation is limited. However, with detectors characterised by a single pixel PSF (e.g. direct, photon-counting X-ray detectors), a significant improvement in spatial resolution can be obtained, demonstrated here at up to 17%.
△ Less
Submitted 20 September, 2022; v1 submitted 14 June, 2021;
originally announced June 2021.
-
LAGraph: Linear Algebra, Network Analysis Libraries, and the Study of Graph Algorithms
Authors:
Gábor Szárnyas,
David A. Bader,
Timothy A. Davis,
James Kitchen,
Timothy G. Mattson,
Scott McMillan,
Erik Welch
Abstract:
Graph algorithms can be expressed in terms of linear algebra. GraphBLAS is a library of low-level building blocks for such algorithms that targets algorithm developers. LAGraph builds on top of the GraphBLAS to target users of graph algorithms with high-level algorithms common in network analysis. In this paper, we describe the first release of the LAGraph library, the design decisions behind the…
▽ More
Graph algorithms can be expressed in terms of linear algebra. GraphBLAS is a library of low-level building blocks for such algorithms that targets algorithm developers. LAGraph builds on top of the GraphBLAS to target users of graph algorithms with high-level algorithms common in network analysis. In this paper, we describe the first release of the LAGraph library, the design decisions behind the library, and performance using the GAP benchmark suite. LAGraph, however, is much more than a library. It is also a project to document and analyze the full range of algorithms enabled by the GraphBLAS. To that end, we have developed a compact and intuitive notation for describing these algorithms. In this paper, we present that notation with examples from the GAP benchmark suite.
△ Less
Submitted 4 April, 2021;
originally announced April 2021.
-
Full field X-ray Scatter Tomography
Authors:
Gary Ruben,
Isaac Pinar,
Jeremy M. C. Brown,
Florian Schaff,
James A. Pollock,
Kelly J. Crossley,
Anton Maksimenko,
Chris Hall,
Daniel Hausermann,
Kentaro Uesugi,
Marcus J. Kitchen
Abstract:
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat.…
▽ More
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45${}^\circ$ to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lung and major airways in the rat. The image contrast in scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.
△ Less
Submitted 10 March, 2022; v1 submitted 16 December, 2020;
originally announced December 2020.
-
Tomographic Reconstruction using Tilted Laue Analyser Based X-ray Phase-Contrast Imaging
Authors:
M. C. Chalmers,
M. J. Kitchen,
K. Uesugi,
G. Falzon,
P. Quin,
K. M. Pavlov
Abstract:
Analyser-Based Phase-Contrast imaging (ABPCI) is a phase-contrast imaging method that produces high contrast images of weakly absorbing materials. However, it is only sensitive to phase variations lying in the diffraction plane of the analyser crystal (i.e in one dimension; 1-D), as it is highly sensitive to phase variations lying in the diffraction plane of the analyser crystal. In order to accur…
▽ More
Analyser-Based Phase-Contrast imaging (ABPCI) is a phase-contrast imaging method that produces high contrast images of weakly absorbing materials. However, it is only sensitive to phase variations lying in the diffraction plane of the analyser crystal (i.e in one dimension; 1-D), as it is highly sensitive to phase variations lying in the diffraction plane of the analyser crystal. In order to accurately account for and measure phase effects produced by the wavefield-sample interaction, ABPCI and other 1-D phase sensitive methods must achieve 2-D phase sensitivity. We applied an inclined geometry method to a Laue geometry setup for X-ray ABPCI through rotation of the detector and object about the optical axis. This allowed this traditionally 1-D phase sensitive phase contrast method to possess 2-D phase sensitivity. We acquired tomographic datasets over 360 degrees of a multi-material phantom with the detector and sample tilted by 8 degrees. The real and imaginary parts of the refractive index were reconstructed for the phantom.
△ Less
Submitted 9 February, 2021; v1 submitted 20 July, 2020;
originally announced July 2020.
-
Material decomposition from a single x-ray projection via single-grid phase contrast imaging
Authors:
Celebrity F. Groenendijk,
Florian Schaff,
Linda C. P. Croton,
Marcus J. Kitchen,
Kaye S. Morgan
Abstract:
This study describes a new approach for material decomposition in x-ray imaging, utilising phase contrast to both increase sensitivity to weakly-attenuating samples and to act as a complementary measurement to attenuation, therefore allowing two overlaid materials to be separated. The measurements are captured using the single-exposure, single-grid x-ray phase contrast imaging technique, with a no…
▽ More
This study describes a new approach for material decomposition in x-ray imaging, utilising phase contrast to both increase sensitivity to weakly-attenuating samples and to act as a complementary measurement to attenuation, therefore allowing two overlaid materials to be separated. The measurements are captured using the single-exposure, single-grid x-ray phase contrast imaging technique, with a novel correction that aims to remove propagation-based phase effects seen at sharp edges in the attenuation image. The use of a single-exposure technique means that images could be collected in a high-speed sequence. Results are shown for both a known two-material sample and for a biological specimen.
△ Less
Submitted 8 February, 2020;
originally announced February 2020.
-
Material Decomposition using Spectral Propagation-based Phase Contrast X-ray Imaging
Authors:
Florian Schaff,
Kaye S. Morgan,
James A. Pollock,
Linda C. P. Croton,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly atten…
▽ More
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly attenuating features and separate them from overlying objects in radiography. We derive an algorithm that performs both tasks simultaneously and verify it against numerical simulations and experimental measurements of ideal two-component samples composed of pure aluminium and poly(methyl methacrylate). Additionally, we showcase first imaging results of a rabbit kitten's lung. The attenuation signal of a thorax, in particular, is dominated by the strongly attenuating bones of the ribcage, which combined with the weak soft tissue signal make it difficult to visualise the fine anatomical structures across the whole lung. In all cases, clean material decomposition was achieved, without residual phase contrast effects, from which we generate an un-obstructed image of the lung, free of bones. Spectral propagation-based phase contrast imaging has the potential to be a valuable tool, not only in future lung research, but also in other systems for which phase contrast imaging in combination with material decomposition proves to be advantageous.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
A simple, pixel-wise response correction for ring artifact removal in both absorption and phase contrast X-ray computed tomography
Authors:
Linda C. P. Croton,
Gary Ruben,
Kaye S. Morgan,
David M. Paganin,
Marcus J. Kitchen
Abstract:
We present a pixel-specific, measurement-driven correction that effectively minimizes errors in detector response that give rise to the ring artifacts commonly seen in X-ray computed tomography (CT) scans. This correction is easy to implement, suppresses CT artifacts significantly, and is effective enough for use with both absorption and phase contrast imaging. It can be used as a standalone corre…
▽ More
We present a pixel-specific, measurement-driven correction that effectively minimizes errors in detector response that give rise to the ring artifacts commonly seen in X-ray computed tomography (CT) scans. This correction is easy to implement, suppresses CT artifacts significantly, and is effective enough for use with both absorption and phase contrast imaging. It can be used as a standalone correction or in conjunction with existing ring artifact removal algorithms to further improve image quality. We validate this method using two X-ray CT data sets, showing post-correction signal-to-noise increases of up to 55%, and we define an image quality metric to use specifically for the assessment of ring artifact suppression.
△ Less
Submitted 22 November, 2018;
originally announced November 2018.
-
In situ phase contrast X-ray brain CT
Authors:
Linda C. P. Croton,
Kaye S. Morgan,
David M. Paganin,
Lauren T. Kerr,
Megan J. Wallace,
Kelly J. Crossley,
Suzanne L. Miller,
Naoto Yagi,
Kentaro Uesugi,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Phase contrast X-ray imaging (PCXI) is an emerging imaging modality that has the potential to greatly improve radiography for medical imaging and materials analysis. PCXI makes it possible to visualise soft-tissue structures that are otherwise unresolved with conventional CT by rendering phase gradients in the X-ray wavefield visible. This can improve the contrast resolution of soft tissues struct…
▽ More
Phase contrast X-ray imaging (PCXI) is an emerging imaging modality that has the potential to greatly improve radiography for medical imaging and materials analysis. PCXI makes it possible to visualise soft-tissue structures that are otherwise unresolved with conventional CT by rendering phase gradients in the X-ray wavefield visible. This can improve the contrast resolution of soft tissues structures, like the lungs and brain, by orders of magnitude. Phase retrieval suppresses noise, revealing weakly-attenuating soft tissue structures, however it does not remove the artefacts from the highly attenuating bone of the skull and from imperfections in the imaging system that can obscure those structures. The primary causes of these artefacts are investigated and a simple method to visualise the features they obstruct is proposed, which can easily be implemented for preclinical animal studies. We show that phase contrast X-ray CT (PCXI-CT) can resolve the soft tissues of the brain in situ without a need for contrast agents at a dose $\sim$400 times lower than would be required by standard absorption contrast CT. We generalise a well-known phase retrieval algorithm for multiple-material samples specifically for CT, validate its use for brain CT, and demonstrate its high stability in the presence of noise.
△ Less
Submitted 24 January, 2018;
originally announced January 2018.
-
CT dose reduction factors in the thousands using X-ray phase contrast
Authors:
Marcus J. Kitchen,
Genevieve A. Buckley,
Timur E. Gureyev,
Megan J. Wallace,
Nico Andres-Thio,
Kentaro Uesugi,
Naoto Yagi,
Stuart B. Hooper,
.
Abstract:
Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without…
▽ More
Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without loss of image quality. Our experiments reveal that as radiation dose decreases, the relative improvement in SNR increases. We discovered this enhancement can be traded for a reduction in dose greater than the square of the gain in SNR. Upon reducing the dose 300 fold, the phase-retrieved SNR was still almost 10 times larger than the absorption contrast data. This reveals the potential for dose reduction factors in the tens of thousands without loss in image quality, which would have a profound impact on medical and industrial imaging applications.
△ Less
Submitted 11 April, 2017;
originally announced April 2017.
-
Extraction of depth moments by exploiting the partial coherence of radiation
Authors:
M. A. Beltran,
T. C. Petersen,
M. J. Kitchen,
D. M. Paganin
Abstract:
We retrieve depth information (moments) of an object using partially coherent fields and defocus induced holographic contrast. Our analysis leads to a form of tomography that does not require sample or source rotation. The tomography method presented here is performed with only two in-line images.
We retrieve depth information (moments) of an object using partially coherent fields and defocus induced holographic contrast. Our analysis leads to a form of tomography that does not require sample or source rotation. The tomography method presented here is performed with only two in-line images.
△ Less
Submitted 11 April, 2016; v1 submitted 20 December, 2015;
originally announced December 2015.
-
Aberrations in shift-invariant linear optical imaging systems using partially coherent fields
Authors:
Mario A. Beltran,
Marcus J. Kitchen,
T. Petersen,
David M. Paganin
Abstract:
Here the role and influence of aberrations in optical imaging systems employing partially coherent complex scalar fields is studied. Imaging systems require aberrations to yield contrast in the output image. For linear shift-invariant optical systems, we develop an expression for the output cross-spectral density under the space-frequency formulation of statistically stationary partially coherentf…
▽ More
Here the role and influence of aberrations in optical imaging systems employing partially coherent complex scalar fields is studied. Imaging systems require aberrations to yield contrast in the output image. For linear shift-invariant optical systems, we develop an expression for the output cross-spectral density under the space-frequency formulation of statistically stationary partially coherentfields. We also develop expressions for the output cross{spectral density and associated spectral density for weak-phase, weak-phase-amplitude, and single-material objects in one transverse spatial dimension.
△ Less
Submitted 28 June, 2015; v1 submitted 3 August, 2014;
originally announced August 2014.
-
The limits of selection under plant domestication
Authors:
Robin G. Allaby,
Dorian Q. Fuller,
James L. Kitchen
Abstract:
Plant domestication involved a process of selection through human agency of a series of traits collectively termed the domestication syndrome. Current debate concerns the pace at which domesticated plants emerged from cultivated wild populations and how many genes were involved. Here we present simulations that test how many genes could have been involved by considering the cost of selection. We d…
▽ More
Plant domestication involved a process of selection through human agency of a series of traits collectively termed the domestication syndrome. Current debate concerns the pace at which domesticated plants emerged from cultivated wild populations and how many genes were involved. Here we present simulations that test how many genes could have been involved by considering the cost of selection. We demonstrate the selection load that can be endured by populations increases with decreasing selection coefficients and greater numbers of loci down to values of about s = 0.005, causing a driving force that increases the number of loci under selection. As the number of loci under selection increases, an effect of co-selection increases resulting in individual unlinked loci being fixed more rapidly in out-crossing populations, representing a second driving force to increase the number of loci under selection. In inbreeding systems co-selection results in interference and reduced rates of fixation but does not reduce the size of the selection load that can be endured. These driving forces result in an optimum pace of genome evolution in which 50-100 loci are the most that could be under selection in a cultivation regime. Furthermore, the simulations do not preclude the existence of selective sweeps but demonstrate that they come at a cost of the selection load that can be endured and consequently a reduction of the capacity of plants to adapt to new environments, which may contribute to the explanation of why selective sweeps have been so rarely detected in genome studies.
△ Less
Submitted 5 March, 2014;
originally announced March 2014.