-
The REgolith X-Ray Imaging Spectrometer (REXIS) for OSIRIS-REx: Identifying Regional Elemental Enrichment on Asteroids
Authors:
Branden Allen,
Jonathan Grindlay,
Jaesub Hong,
Richard P. Binzel,
Rebecca Masterson,
Niraj K. Inamdar,
Mark Chodas,
Matthew W. Smith,
Marshall W. Bautz,
Steven E. Kissel,
Joel Villasenor,
Miruna Oprescu,
Nicholas Induni
Abstract:
The OSIRIS-REx Mission was selected under the NASA New Frontiers program and is scheduled for launch in September of 2016 for a rendezvous with, and collection of a sample from the surface of asteroid Bennu in 2019. 101955 Bennu (previously 1999 RQ36) is an Apollo (near-Earth) asteroid originally discovered by the LINEAR project in 1999 which has since been classified as a potentially hazardous ne…
▽ More
The OSIRIS-REx Mission was selected under the NASA New Frontiers program and is scheduled for launch in September of 2016 for a rendezvous with, and collection of a sample from the surface of asteroid Bennu in 2019. 101955 Bennu (previously 1999 RQ36) is an Apollo (near-Earth) asteroid originally discovered by the LINEAR project in 1999 which has since been classified as a potentially hazardous near-Earth object. The REgolith X-Ray Imaging Spectrometer (REXIS) was proposed jointly by MIT and Harvard and was subsequently accepted as a student led instrument for the determination of the elemental composition of the asteroid's surface as well as the surface distribution of select elements through solar induced X-ray fluorescence. REXIS consists of a detector plane that contains 4 X-ray CCDs integrated into a wide field coded aperture telescope with a focal length of 20 cm for the detection of regions with enhanced abundance in key elements at 50 m scales. Elemental surface distributions of approximately 50-200 m scales can be detected using the instrument as a simple collimator. An overview of the observation strategy of the REXIS instrument and expected performance are presented here.
△ Less
Submitted 25 September, 2013;
originally announced September 2013.
-
Physics of reverse annealing in high-resistivity Chandra ACIS CCDs
Authors:
C. E. Grant,
B. LaMarr,
G. Y. Prigozhin,
S. E. Kissel,
S. K. Brown,
M. W. Bautz
Abstract:
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane wa…
▽ More
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane was warmed from the operating temperature of -100C to +30C which unexpectedly further increased the CTI. We report results of ACIS CCD irradiation experiments in the lab aimed at better understanding this reverse annealing process. Six CCDs were irradiated cold by protons ranging in energy from 100 keV to 400 keV, and then subjected to simulated bakeouts in one of three annealing cycles. We present results of these lab experiments, compare them to our previous experiences on the ground and in flight, and derive limits on the annealing time constants.
△ Less
Submitted 10 July, 2008;
originally announced July 2008.
-
Performance of the Charge Injection Capability of Suzaku XIS
Authors:
H. Nakajima,
H. Yamaguchi,
H. Matsumoto,
T. G. Tsuru,
K. Koyama,
H. Tsunemi,
K. Hayashida,
K. Torii,
M. Namiki,
S. Katsuda,
M. Shoji,
D. Matsuura,
T. Miyauchi,
T. Dotani,
M. Ozaki,
H. Murakami,
M. W. Bautz,
S. E. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments…
▽ More
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments using a radiation damaged device, and in-orbit measurements of the XIS. The ground experiments show that charges are stably injected with the dispersion of 91eV in FWHM in a specific column for the charges equivalent to the X-ray energy of 5.1keV. This dispersion width is significantly smaller than that of the X-ray events of 113eV (FWHM) at approximately the same energy. The amount of charge loss during transfer in a specific column, which is measured with the charge injection capability, is consistent with that measured with the calibration source. These results indicate that the charge injection technique can accurately measure column-dependent charge losses rather than the calibration sources. The column-to-column CTI correction to the calibration source spectra significantly reduces the line widths compared to those with a column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at the time of one year after the launch). In addition, this method significantly reduces the low energy tail in the line profile of the calibration source spectrum.
△ Less
Submitted 12 May, 2007;
originally announced May 2007.
-
Discoveries of Diffuse Iron Line Sources from the Sgr B Region
Authors:
Katsuji Koyama,
Tatsuya Inui,
Yoshiaki Hyodo,
Hironori Matsumoto,
Takeshi Go Tsuru,
Yoshitomo Maeda,
Hiroshi Murakami,
Shigeo Yamauchi,
Steven E. Kissel,
Kai-Wing,
Chan Yang Soong
Abstract:
The radio complex Sgr B region is observed with the X-Ray Imaging Spectrometers (XIS) on board Suzaku. This region exhibits diffuse iron lines at 6.4, 6.7 and 6.9 keV, which are K$α$ lines of Fe \emissiontype{I} (neutral iron), Fe\emissiontype{XXV} (He-like iron) and Fe\emissiontype{XXVI} (H-like iron), respectively. The high energy resolving power of the XIS provides the separate maps of the K-…
▽ More
The radio complex Sgr B region is observed with the X-Ray Imaging Spectrometers (XIS) on board Suzaku. This region exhibits diffuse iron lines at 6.4, 6.7 and 6.9 keV, which are K$α$ lines of Fe \emissiontype{I} (neutral iron), Fe\emissiontype{XXV} (He-like iron) and Fe\emissiontype{XXVI} (H-like iron), respectively. The high energy resolving power of the XIS provides the separate maps of the K-shell transition lines from Fe\emissiontype{I} (6.4 keV) and Fe\emissiontype{XXV} (6.7 keV). Although the 6.7 keV line is smoothly distributed over the Sgr B region, a local excess is found near at $(l, b) = (\timeform {0D.61}, \timeform{0D.01})$, possibly a new SNR. The plasma temperature is \textit{kT} $\sim$3 keV and the age is estimated to be around several$\times10^{3}$ years. The 6.4 keV image is clumpy with local excesses nearby Sgr B2 and at $(l, b) = (\timeform{0D.74}, -\timeform{0D.09})$. Like Sgr B2, this excess may be another candidate of an X-ray reflection nebula (XRN).
△ Less
Submitted 12 September, 2006;
originally announced September 2006.
-
Temperature dependence of charge transfer inefficiency in Chandra X-ray CCDs
Authors:
C. E. Grant,
M. W. Bautz,
S. E. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magn…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on develo** techniques to mitigate CTI and spectral resolution degradation. We present the initial temperature dependence of ACIS CTI from -120 to -60 degrees Celsius and the current temperature dependence after more than six years of continuing slow radiation damage. We use the change of shape of the temperature dependence to speculate on the nature of the damaging particles.
△ Less
Submitted 7 June, 2006;
originally announced June 2006.