-
Precision tests of Quantum Mechanics and CPT symmetry with entangled neutral kaons at KLOE
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
R. D'Amico,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
E. Diociaiuti,
D. Domenici,
A. D'Uffizi,
A. Fantini,
G. Fantini
, et al. (33 additional authors not shown)
Abstract:
The quantum interference between the decays of entangled neutral kaons is studied in the process $φ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon…
▽ More
The quantum interference between the decays of entangled neutral kaons is studied in the process $φ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and CPT violation effects, which may be justified in a quantum gravity framework. The analysed data sample was collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, and corresponds to an integrated luminosity of about 1.7 fb$^{-1}$, i.e. to about $1.7 \times 10^9$ $φ\rightarrow K_S K_L$ decays produced. From the fit of the observed $Δt$ distribution, being $Δt$ the difference of the kaon decay times, the decoherence and CPT violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses. The results are consistent with no deviation from quantum mechanics and CPT symmetry, while for some parameters the precision reaches the interesting level at which -- in the most optimistic scenarios -- quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.
△ Less
Submitted 6 April, 2022; v1 submitted 8 November, 2021;
originally announced November 2021.
-
Upper limit on the $η\toπ^{+}π^{-}$ branching fraction with the KLOE experiment
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini,
P. Fermani,
S. Fiore,
A. Gajos
, et al. (31 additional authors not shown)
Abstract:
Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $φ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching f…
▽ More
Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $φ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching fraction at 90\% confidence level is determined to be ${\mathcal B}(η\toπ^{+}π^{-})<4.9\times10^{-6}$, which is approximately three times smaller than the previous KLOE result. From the combination of these two measurements we get ${\mathcal B}(η\toπ^{+}π^{-}) < 4.4\times10^{-6}$ at 90\% confidence level.
△ Less
Submitted 28 February, 2021; v1 submitted 25 June, 2020;
originally announced June 2020.
-
Combined limit on the production of a light gauge boson decaying into $μ^+μ^-$ and $π^+π^-$
Authors:
KLOE-2 Collaboration,
:,
A. Anastasi,
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostinio,
E. Dané,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini
, et al. (35 additional authors not shown)
Abstract:
We searched for the $μ^+μ^-$ decay of a light vector gauge boson, also known as dark photon, in the $e^+ e^- \to μ^+ μ^- γ_{\rm ISR}$ process by means of the Initial State Radiation (ISR) method. We used 1.93~fb$^{-1}$ of data collected by the KLOE experiment at the DA$Φ$NE $φ$-factory. No structures have been observed over the irreducible $μ^+ μ^-$ background. A 90\% CL limit on the ratio…
▽ More
We searched for the $μ^+μ^-$ decay of a light vector gauge boson, also known as dark photon, in the $e^+ e^- \to μ^+ μ^- γ_{\rm ISR}$ process by means of the Initial State Radiation (ISR) method. We used 1.93~fb$^{-1}$ of data collected by the KLOE experiment at the DA$Φ$NE $φ$-factory. No structures have been observed over the irreducible $μ^+ μ^-$ background. A 90\% CL limit on the ratio $\varepsilon^2=α^{\prime}/α$ between the dark coupling constant and the fine structure constant of $ 3\times 10^{-6}-2\times 10^{-7}$ has been set in the dark photon mass region between 519 MeV and 973 MeV. This new limit has been combined with the published result obtained investigating the hypothesis of the dark photon decaying into hadrons in $e^+ e^- \to π^+ π^- γ_{\rm ISR}$ events. The combined 90\% CL limit increases the sensitivity especially in the $ρ-ω$ interference region and excludes $\varepsilon^2$ greater than $(13-2)\times 10^{-7}$. For dark photon masses greater than 600 MeV the combined limit is lower than 8~$\times\, 10^{-7}$ resulting more stringent than present constraints from other experiments.
△ Less
Submitted 9 August, 2018; v1 submitted 7 July, 2018;
originally announced July 2018.
-
Measurement of the charge asymmetry for the $K_S \rightarrow πe ν$ decay and test of CPT symmetry with the KLOE detector
Authors:
A. Anastasi,
D. Babusci,
M. Berłowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
G. Capon,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini,
G. Fantini
, et al. (35 additional authors not shown)
Abstract:
Using 1.63 fb$^{-1}$ of integrated luminosity collected by the KLOE experiment about $7\times 10^4$ $K_S \rightarrow π^{\pm}e^{\mp}ν$ decays have been reconstructed. The measured value of the charge asymmetry for this decay is $A_S = (-4.9 \pm 5.7_{stat} \pm 2.6_{syst}) \times 10^{-3}$, which is almost twice more precise than the previous KLOE result. The combination of these two measurements give…
▽ More
Using 1.63 fb$^{-1}$ of integrated luminosity collected by the KLOE experiment about $7\times 10^4$ $K_S \rightarrow π^{\pm}e^{\mp}ν$ decays have been reconstructed. The measured value of the charge asymmetry for this decay is $A_S = (-4.9 \pm 5.7_{stat} \pm 2.6_{syst}) \times 10^{-3}$, which is almost twice more precise than the previous KLOE result. The combination of these two measurements gives $A_S = (-3.8 \pm 5.0_{stat} \pm 2.6_{syst}) \times 10^{-3}$ and, together with the asymmetry of the $K_L$ semileptonic decay, provides significant tests of the CPT symmetry. The obtained results are in agreement with CPT invariance.
△ Less
Submitted 11 August, 2018; v1 submitted 22 June, 2018;
originally announced June 2018.
-
Combination of KLOE $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ measurements and determination of $a_μ^{π^+π^-}$ in the energy range $0.10 < s < 0.95$ GeV$^2$
Authors:
The KLOE-2 Collaboration,
:,
A. Anastasi,
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
L. Caldeira Balkeståhl,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi
, et al. (41 additional authors not shown)
Abstract:
The three precision measurements of the cross section $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of thes…
▽ More
The three precision measurements of the cross section $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of these measurements requires covariance matrices that fully describe the correlations. We present the construction of these covariance matrices and use them to determine a combined KLOE measurement for $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$. We find, from this combination, a two-pion contribution to the muon magnetic anomaly in the energy range $0.10 < s < 0.95$ GeV$^2$ of $a_μ^{π^+π^-} = (489.8 \pm 1.7_{\rm stat} \pm 4.8_{\rm sys} ) \times 10^{-10}$.
△ Less
Submitted 8 June, 2018; v1 submitted 8 November, 2017;
originally announced November 2017.
-
Introduction of total variation regularization into filtered backprojection algorithm
Authors:
L. Raczyński,
W. Wiślicki,
K. Klimaszewski,
W. Krzemień,
P. Kowalski,
R. Shopa,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska-Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image…
▽ More
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.
△ Less
Submitted 31 October, 2017;
originally announced November 2017.
-
J-PET: a new technology for the whole-body PET imaging
Authors:
S. Niedźwiecki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
Ł. Kapłon,
D. Kisielewska-Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
M. Pałka,
L. Raczyński,
Z. Rudy,
N. G. Sharma,
S. Sharma
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.
△ Less
Submitted 31 October, 2017;
originally announced October 2017.
-
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
Authors:
R. Y. Shopa,
K. Klimaszewski,
P. Kowalski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska-Kamińska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were…
▽ More
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.
-
Analysis procedure of the positronium lifetime spectra for the J-PET detector
Authors:
K. Dulski,
B. Zgardzinska,
P. Bialas,
C. Curceanu E. Czerwinski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
D. Kisielewska-Kaminska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemiez,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedzwiecka,
S. Niedzwiecki,
M. Palka,
L. Raczynski,
J. Raj,
Z. Rudy,
N. G. Sharma,
S. Sharma
, et al. (8 additional authors not shown)
Abstract:
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics…
▽ More
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the J-PET software. We compare its performance with the standard program LT 9.0 by using PALS data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
△ Less
Submitted 16 October, 2017;
originally announced October 2017.
-
Time calibration of the J-PET detector
Authors:
M. Skurzok,
M. Silarski,
D. Alfs,
P. Bialas,
Shivani,
C. Curceanu,
E. Czerwinski,
K. Dulski,
A. Gajos,
B. Glowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
D. Kisielewska-Kaminska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedzwiecka,
S. Niedzwiecki,
M. Palka,
L. Raczynski
, et al. (10 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cy…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a 22Na source and a small detector providing common reference time for synchronization of all the modules.
△ Less
Submitted 16 October, 2017;
originally announced October 2017.